Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

Battery Energy Storage System (BESS) Installation

Open
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract involves the installation and integration of battery energy storage systems for prime contractors working on California Energy Commission projects. The scope of work focuses on the deployment of lithium-ion battery modules, power conversion systems, and thermal management systems, with a final delivery goal of an operational 1,200 MWh battery storage system. All installations must strictly adhere to UL Solutions, NFPA, and NESC standards to ensure safety and regulatory compliance. The project is categorized under NAICS code 238210 and will be performed in California, specifically within the 92309 zip code area.

General Info

Subcontract for installing a 1,200 MWh battery energy storage system in California.

Documents

This scope was carved out of 24-OPT-03.

The full solicitation package (11 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Soda Mountain Solar Project

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Energy Commission
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs and integrates battery energy storage systems for prime contractors on California Energy Commission projects. Installs lithium-ion battery modules, power conversion systems, and thermal management systems per UL Solutions, NFPA, and NESC standards. Delivers an operational 1,200 MWh battery storage system.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
Inland Empire Job Corps-Request for Quote Electrical Repairs
Solicitation # inland-empire-job-corps-request-quote-electrical-repairs
Management & Training Corporation (MTC) is seeking bids for a fee-for-service subcontract to perform electrical and fire alarm repairs at the Inland Empire Job Corps Center in San Bernardino, California. The scope of work includes installing GFCI protection for multiple receptacles in the cafeteria, culinary arts kitchen, and academic education building, as well as repairing open-ground conditions in the dormitory and medical areas. Additionally, the contractor must install filler plates in panelboards, correct deficiencies for specific panelboards, update circuit directories, and provide permanent labeling for feeder conductors and distribution equipment. All work must comply with National Electrical Code (NEC), NFPA, and applicable federal, state, and local requirements. Bids are due by 3:00 PM PT on November 12, 2026, and must include a lump sum bid sheet, a completed supplier packet with Form W-9, three references for similar projects, and proof of insurance. Required insurance includes general liability with a minimum of $1,000,000 per occurrence and worker's compensation with employer's liability limits of at least $500,000. This opportunity is open to various small business categories, including VOSB, SDVOSB, WOSB, and HUBZone, with SBA certification required for the latter three. The contract is subject to Service Contract Labor Standards wage determinations and various FAR clauses regarding security, whistleblower rights, and the Buy American Act. Invoicing is to be submitted weekly or bi-weekly, and MTC will award the contract based on the best value.
Inland Empire Job Corps

POSTED

about 4 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
26-140 Installation of Emergency Shut Off Switches
Solicitation # 26-140
Solicitation 26-140 is a subcontracting opportunity for the installation of emergency shut-off switches on power tools at the Atterbury Job Corps Center in Edinburgh, Indiana, operated by Adams and Associates for the U.S. Department of Labor. The scope of work requires the installation of two mushroom-head push-button emergency shut-off switches and a new 60A, 208/120V, 3-phase, 4-wire, 6-circuit branch circuit panel with a 60A shunt-trip main circuit breaker in the Facility Engineering Storage/Maintenance Shop. All work must comply with OSHA, EPA, and FNC guidelines, as well as state and local building codes, with Indiana regulations prevailing if they are more stringent than federal requirements. The contractor must provide a one-year guarantee on workmanship and all necessary training and maintenance manuals upon completion. This is a small business set-aside solicitation requiring a single lump sum bid, though the lowest price does not guarantee an award. Evaluation is based on best value, weighted by price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). A mandatory site visit was scheduled for November 10, 2026, with a proposal deadline of November 20, 2026. Qualified offerors must provide a valid Indiana Contractor's License, proof of specific automobile, general liability, and workers compensation insurance, and certify compliance with Davis-Bacon Act wage rates. Payment terms are Net 30. Proposals must be submitted on company letterhead and include a detailed cost breakdown, a construction timeline, and a completed SF 1413.
Atterbury Job Corps. – Adams & Associates

POSTED

about 4 hours ago

DEADLINE

in 13 days
View Details
NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for transformer oil testing services to improve the efficiency, safety, and consistency of its transformer maintenance. The project focuses on three primary objectives: conducting condition assessments through visual and infrared thermographic inspections of energized transformers, installing standardized external oil sampling devices to enhance technician safety, and performing detailed oil testing analysis. All work must adhere to NETA MTS, IEEE, NFPA 70E, and ASTM D923 standards, with infrared inspections performed by ASNT Level 1 certified technicians or equivalent. Key deliverables include annotated inspection results, written condition reports for each asset, comprehensive standard operating procedures, and on-site training for up to 20 agency staff members. This is a fixed-pricing contract with a not-to-exceed total price, intended as a single award to the most capable and cost-effective offeror. Proposals are due by December 23, 2026, via PlanetBids and must include a detailed project approach, company profile, and three references from similar projects completed within the last five years. Evaluation criteria emphasize personnel experience, staffing plans, and the ability to meet the project timeline. The contract requires contractors to be registered with the Department of Industrial Relations for prevailing wage compliance and to provide certificates of insurance. Payments are made electronically via ACH, with an expedited payment protocol available for consultants who accept specific invoice reductions.
Inland Empire Utilities Agency

POSTED

about 4 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 238210
New
Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility
Solicitation # purified-water-replenishment-san-jacinto-valley-advanced-water-purification-facility-2
Axia Electric LLC is soliciting bids from SBE/DBE certified firms for the Eastern Municipal Water District's Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility Project in California. The scope of work is divided into two major components, the San Jacinto Valley Advanced Water Purification Facility and Brine Ponds, with specific needs for low voltage systems, fiber optics, and electrical materials and supplies. Bids must be submitted by 2:00 PM on November 18th to be considered responsive, with a final deadline of November 19th. Qualified bidders must be registered to perform public work pursuant to Labor Code Section 1725.5 and must adhere to the AGC Master Labor Agreements and the terms of the prime contract. Minimum insurance requirements include 1 million dollars for General Liability per occurrence, 2 million dollars for Aggregate and Completed Operations, 5 million dollars for Excess Liability, 1 million dollars for Auto Liability, and 1 million dollars for Workers Compensation and Employer Liability. Submission of a bid constitutes acceptance of Axia's Standard Long Form Subcontract or Purchase Order. Non-SBE/DBE firms are encouraged to provide information regarding lower-tier SBE/DBE participation for evaluation.
Axia Electric

POSTED

about 4 hours ago

DEADLINE

in 12 days
View Details
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management & Training Corporation is soliciting bids for a fixed-price, single lump sum subcontract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project, with an estimated value between $25,000 and $100,000, requires a qualified electrical contractor to inventory, inspect, test, repair, and certify all emergency lighting systems in accordance with NFPA 101 (2024 Edition), NFPA 70, and OSHA regulations. Key deliverables include the restoration of systems to full operation, the application of durable tracking labels to fixtures, integration of maintenance requirements into the facility's Computerized Maintenance Management System, and the provision of hazardous material disposal certificates. Bids are due by December 1, 2026, and will be awarded based on overall best value. Mandatory requirements for submission include a physical site visit, a signed bid form, a detailed cost breakout on company letterhead, and a completed supplier onboarding packet. For bids equal to or exceeding $25,000, contractors must provide a bid bond guarantee of 20% of the base bid, and the awarded contractor will be required to furnish performance and payment bonds from a surety with at least an A- rating. The contract is subject to the Davis-Bacon Act, Federal Contractor Minimum Wage requirements under Executive Order 14026, and various FAR clauses regarding small business utilization, security, and whistleblower rights.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 25 days
View Details

More opportunities from California → Energy Commission

Same awarding agency

NAICS: 237130
SLED
Corby Battery Energy Storage System Project
Solicitation # 24-OPT-05
North Bay Interconnect, LLC and Corby Energy Storage, LLC are proposing the construction and operation of the Corby Battery Energy Storage System (BESS) Project in Solano County, California. The facility will feature a 300-megawatt, 1,200-megawatt-hour system utilizing LG Energy Solution lithium-ion batteries. The project site encompasses approximately 40.3 acres and includes a project substation, inverters, and ancillary infrastructure such as sound barriers, stormwater retention basins, and a SCADA system. Interconnection to the Pacific Gas and Electric Company Vaca-Dixon Substation will be achieved via a 1.1-mile, 230-kilovolt generation tie line consisting of both overhead and underground segments. The initial installation will include 303 BESS enclosures, with planned augmentations every three years starting around year six to maintain output, eventually reaching up to 341 enclosures. The project is overseen by the California Energy Commission and is subject to rigorous environmental and regulatory compliance, including the California Environmental Quality Act and Assembly Bill 205 regarding prevailing wages and a skilled workforce. Construction is estimated to take 14 to 15 months. Technical standards for the build follow a comprehensive list of codes including NFPA, ANSI, and ASME, with oversight provided by a Delegate Chief Building Official and a Safety Monitor to ensure Cal OSHA compliance. Hazardous materials transportation must adhere to DOT and PHMSA regulations. The project involves a minimum investment of 100 million dollars in California and has undergone extensive review by agencies such as the California Department of Fish and Wildlife and the Native American Heritage Commission to mitigate impacts on special-status species and tribal cultural resources.
Power and Communication Line and Related Structures Construction

POSTED

4 months ago

DEADLINE

N/A
View Details
NAICS: 237130
SLED
Potentia-Viridi Battery Energy Storage System
Solicitation # 24-OPT-04
The Potentia-Viridi Battery Energy Storage System (BESS) project, identified by solicitation number 24-OPT-04, involves the construction and operation of a large-scale lithium-ion battery storage facility located on approximately 102 acres of retired agricultural land in eastern Alameda County, California. The facility is designed to provide 400 megawatts of power with an energy storage capacity of up to 3,200 megawatt-hours. Key infrastructure components include modular and containerized BESS enclosures, an operations and maintenance building, a project substation, and a 500 kilovolt overhead generation tie-in line that will connect to the PG&E Tesla Substation. The project is being overseen by the California Energy Commission (CEC) under its Opt-In Certification Program and requires compliance with the California Environmental Quality Act (CEQA). The project development process has involved extensive regulatory review and consultation with various state agencies to address environmental, cultural, and resource impacts. The California Department of Fish and Wildlife and the Central Valley Regional Water Quality Control Board have provided oversight regarding biological resources, habitat assessments for special-status species, and water quality protection. Additionally, the Native American Heritage Commission has emphasized the need for tribal cultural resource protection and compliance with AB 52 and SB 18. The project must adhere to strict safety and environmental standards, including Department of Transportation regulations for hazardous materials transportation, EPA methods for air quality testing, and specific mitigation measures for agricultural land preservation and wildlife habitat. Construction of the facility is expected to create prevailing wage jobs and requires specialized biological monitoring for species such as the burrowing owl and Crotch's bumble bee.
Power and Communication Line and Related Structures Construction

POSTED

5 months ago

DEADLINE

N/A
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS