Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on January 18, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C--A/E DESIGN PROJECT: 667-18-106 Replace Cooling Towers Shreveport, LA

Awarded
36C25618R0366Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Yucca Trail Widening Project – Palomar Avenue To La Contenta Road
Solicitation # 7074
The Town of Yucca Valley is soliciting professional civil engineering design services for the Yucca Trail Widening Project, located between Palomar/Avalon Avenue and La Contenta Road in Yucca Valley, California. The selected contractor will be responsible for creating a comprehensive Plans, Specifications, and Engineer's Estimates package, which includes street improvement, signing, striping, and streetlight plans, as well as final cost estimates and record drawings. The scope requires the consultant to evaluate the project for safety, constructability, utility conflicts, right-of-way constraints, and ADA compliance, utilizing the latest version of AutoCAD and adhering to the Standard Specifications for Public Works Construction and Town driveway standards. The agreement is for an initial term of two years, with a possible two-year extension upon mutual consent. Proposals must be submitted in two separate sealed envelopes by December 3, 2026, with the technical proposal limited to ten pages. Evaluation criteria include the service approach, company qualifications, past performance, proximity of the contractor's office, and the ability to commence work immediately. Compensation will be negotiated after the contractor is selected, and the Town aims to process undisputed monthly invoices within forty-five days. While the contractor must provide worker's compensation and indemnity insurance, it is noted that California prevailing wage laws do not apply to this specific agreement.
Town of Yucca Valley

POSTED

about 6 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

Contract 36C25619C0030 is an award notice issued by the Department of Veterans Affairs, specifically through the Network Contract Office 16. The agreement was granted to Lachin Architects, A Professional Corporation, for the architectural and engineering design project 667-18-106, which involves the replacement of cooling towers in Shreveport, Louisiana. The total value of the award is 595,468.93 dollars. The project falls under NAICS code 541330 and was officially posted on January 18, 2019. The contracting office responsible for the project is located in Ridgeland, Mississippi.

General Info

VA awarded Lachin Architects $595,468.93 for cooling tower replacement in Shreveport, Louisiana.

Contract Value

$27,725

NAICS

541330 - Engineering Services

Place of Performance

MS, USA

Set-Aside

NONE

Award Issued Date

Documents

1

Award Notice - 36C25619C0030 (A/E Design Project: 667-18-106 Replace Cooling Towers)

DOCX, Low priorityaward
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
ContactsNo contacts available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA
ContactsNo contact information available

Full Description

Show more
3C25618R0366 CONTRACT INFORMATION: General. A-E Services are being procured in accordance with the Selection of Architects and Engineers Statute (Public Law 92-582), formerly known as the Brooks Act, and implemented in Federal Acquisition Regulation (FAR) 36.6. All submissions will be evaluated in accordance with the evaluation criteria. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Firms will be selected based on demonstrated competence and qualifications for the required work. The NAICS Code for this acquisition is 541330 Engineering Services and the applicable Small Business Size Standard is $15.0M. The area of consideration is RESTRICTED to a 500 mile radius of the Overton Brooks VA Medical Center, 510 E. Stoner Avenue, Shreveport, LA 71101-4295 in which either the A/E firm s Primary or established Auxiliary/Satellite office must be located. Note: The 500 mile radius will be measured by one or more of the nationally recognized commercial free on-line mapping services from the Primary or established Auxiliary/Satellite Office Address to the above VA address (shortest driving distance option). Contract Award Procedure: The proposed A/E services will be obtained by a Negotiated Firm-Fixed Price Contract. Interested parties shall ensure current Licensing and have a current registration in the System for Award Management (SAM) database at https://www.sam.gov and the Vendor Information Pages database at http://www.va.gov/osdbu well as have submitted the current cycle VETS-4212 Report http://www.dol.gov/vets/programs/fcp/main.htm (for contracts in the amount of $150,000.00 or more) Failure of a proposed SDVOSB to be certified by the CVE at the time the SF 330 is submitted shall result in elimination from consideration as a proposed contractor. SDVOSB Requirements: In accordance with VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside, a service disabled veteran-owned small business concern agrees that, in the performance of the contract, at least 50 percent of the cost of personnel for contract performance will be spent for employees of the concern or employees of other service-disabled veteran-owned small business concerns. c. Design Costs: All offerors are advised that in accordance with VAAR 836.606-73(a) the total cost of the architect or engineer services contracted for must not exceed 6 percent of the estimated cost of the construction project plus any fees for related services and activities. Additionally, FAR 52.236-22 Design Within Funding Limitations, will be applicable to this procurement action. Design limitation costs will be provided to the most highly rated AE firm selected to complete the design. The magnitude for construction (not design) of this project is between $5,000,000 and $10,000,000. SELECTION CRITERIA: The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and VAAR 836.602-1 and are listed below in descending order of importance. The completed SF 330 will be evaluated by the Overton Brooks VA Medical Center Evaluation Board in accordance with FAR 36.602-1 and VAAR 836.602-1. (1) Professional qualifications necessary for satisfactory performance of required services; (2) Specialized experience and technical competence in the type of work required; (3) Capacity to accomplish the work in the required time; (4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; (5) Location in the general geographical area of the project and knowledge of the locality of the project (500 miles); (6) Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. (7) Record of significant claims against the firm because of improper or incomplete architectural and engineering services. (8) Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. SUBMITTAL REQUIREMENT: This project is a 100% set-aside for Service-Disabled Veteran Owned Small Business (SDVOSB) concerns under VAAR 852.219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (Dec 2009). All original Standard Form (SF) 330 packages shall be submitted to: Alexandria Veterans Health Care System Network Contracting Office 16 (NCO 16) ATTN: Gina Roach Bldg 5 Rm 212A 2495 Shreveport Hwy, 71 N Pineville, LA 71360 (a) All SF 330 submissions shall be clearly marked with the subject line displaying the Solicitation Number 36C25618R0366. The SF 330 form may be downloaded from http://www.gsa.gov/portal/forms/type/SF. Completed SF 330 s shall include the primary firms, subcontractor firms, and any consultants expected to be used on the project. (b) Firms that meet the requirements listed in this announcement are invited to submit three (3) copies of the completed SF 330 including Parts I and II as described herein, to the above address no later than 2:00 P.M. (CST) on FRIDAY - MAY 18, 2018. FAX AND/OR E-MAIL SUBMISSIONS WILL NOT BE ACCEPTED. Late proposal rules found in FAR 15.208 will be followed for late submittals. (c) Interested firms shall address each of the Eight (8) Selection Criteria in their SF 330 s and additional documents/submittals. THIS IS NOT A REQUEST FOR PROPOSAL. THERE ARE NO SOLICITATION DOCUMENTS AVAILABLE. This is a request for SF 330 s Architect/Engineer Qualifications packages only. Any requests for a solicitation will not receive a response. This requirement is subject to Availability of Funds. PROJECT INFORMATION: Request for Proposal To Design Replace Cooling Towers Project No. 667-18-106 Overton Brooks VA Medical Center, Shreveport, LA A. General Information A 1.0 Project Background, Description and Scope of Work Provide Architect/Engineer professional services to include site investigation, design development, construction documents, specifications, cost estimates, construction period services and construction site visits. Overton Brooks VAMC has a requirement to design a project to replace the existing condensing water system that supports our existing and future chillers located in building 2. The design shall also include adding backup electrical power to support the existing and future chiller/condensing water plant. The future capacity to design for is upgrading to current capacity and N+1. The design shall include providing HVAC load calculation of the facility to determine the size of the new condenser water system and N+1. The design shall include providing 3 proposed new locations for the new cooling tower system, as 3D renderings. One of the locations shall be on the roof of the chiller or boiler plant. The design shall include providing a complete replacement of the condensing water system including but not limited to the cooling towers, pumps, filtration system & building, valves, strainers, piping, drainage, supporting structure, controls, access to all components, electrical hoist for appropriate component replacement, asbestos removal, electrical, architectural, all associated components necessary to provide a fully functioning system. The new system shall be installed independently with the existing system in full operation. Phasing shall be provided to minimize change over time to the new system. Design shall be provided to demolish the existing system and repair the site, after the new system is fully operational. The design shall also provide modifications to the existing and adding new electrical back up power to support the new cooling towers and existing chiller plant. Provide the design of a backup power system including but not limited to enclosed generators, ATS, MCC, power study, fuel supply piping & system, and any required Arch & MEP upgrade to location selected. The design shall include proper electrical outlets, supporting structure, security, protection, drainage, etc. to support the new system and components. The designer shall perform and provide their own asbestos survey of all areas of impact and include abatement in the design package. The design shall be in accordance with (IAW) the latest version of all applicable VA Design Guidelines and Space Planning Criteria. The completed design shall include, but not limited to, the following systems: Life Safety, Architectural, Mechanical, Electrical, Plumbing, Structural, Controls, Communications, Specialty Work, Asbestos Abatement and Fire Alarms/Protection. Utilities or systems supporting the space shall be evaluated and any discrepancies addressed/corrected in the design. The heating ventilation and air conditioning (HVAC) systems supporting the space shall be tested by the designer and any air balancing adjustments required to meet the VA s HVAC Design Guide shall be incorporated into the design documents. All asbestos containing material within the space shall be abated. Any systems (conduit, wiring, piping, ductwork, appurtenances, etc.), particularly above ceiling, shall be documented (as-built) and any items determined to be abandoned or no longer required shall be identified to be removed and capped or terminated. The Architectural Barriers Act Accessibility Standards (ABAAS-2015) requirements shall be incorporated into the design and where structurally feasible, the VA Barrier Free Design Standard PG 18-13, supplement to the ABAAS shall be incorporated to the greatest extend possible. The design shall also incorporate proper construction phasing of work with time limitations. Access and continued function/operation of adjacent occupied spaces (above, below and beside) shall be considered within the construction phasing plan to minimize the overall impact and disruptions generated by the construction activities. This contract will provide for complete site investigation, design (construction documents), construction period services (CPS) and construction site visits. PERIOD OF PERFORMANCE The delivery date for this contract shall be 350 calendar days from Notice to Proceed broken down into the following phases: Floor Plan/ Schematic Design, 45 calendar days from the NTP, 35% submittal (Conceptual Design) including cost estimate, 60 calendar days from VA approval of the Schematic Design, 65% submittal (Design Development) including Technical Specifications and cost estimate, 80 calendar days from VA approval of Conceptual Design, 95% submittal (Final Design) including Technical Specifications and cost estimate, 80 calendar days from VA approval of Design Development, 100% (Construction Plans) including Technical Specifications and cost estimate, 14 calendar days from the VA approval of the Final Design Plans. VA reviews will be completed within 16 calendar days of the receipt of a complete submittal package. LOCATION Overton Brooks Veterans Affairs Medical Center 510 E. Stoner Ave. Shreveport, LA 71101 TERMS OF THE SOLICITATION The term responsibility, used in the instructions that follow, includes architectural and engineering design, cost, schedule and construction responsibility for completion of this project in accordance with the documents of this RFP for OBVAMC project no. 667-18-106. It is the responsibility of the Design Offeror or A/E to provide complete Design Documents (drawings and specifications) for a fully functional facility. Omissions in this RFP and Technical Requirements do not relieve the Design Offeror from providing a complete and fully functioning design package and service. The terms Design Team , Design Offeror , AE or A/E refers to the successful design team. The design team shall consist of a Service Connected (Disabled) Veteran Owned Small Business architectural/engineering firm and all associated consultants and subcontractors. The term Design Team or engineer refers to registered/licensed Architects and Engineering professionals. The terms the work and project refers to the all site investigation, site survey, calculations, testing and design for documents to perform the renovation at OBVAMC. The term VA and the term VAMC refers to the Overton Brooks Veterans Affairs Medical Center in Shreveport, LA. The VAMC Coordinator and COR (Contracting Officer s Representative) for this project is Kevin James at +1 (555) 000-0000, contact@example.gov The CO (Contracting Officer) for this project is to be determined (TBD). QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) The Design Offeror or A/E shall develop, execute and demonstrate that the project plans and specifications have gone through a rigorous review and coordination effort. The A/E shall provide a copy of the Quality Assurance/ Quality Control Program that will be followed for this project for review and approval by the VA. COST ESTIMATE A detailed estimate of construction cost (using RS Means, Cost Works) and Market Study/Survey shall be provided with each design submission. Design Offeror or A/E shall incorporate into the cost estimates any impact from the requirement that the construction be performed by a Service Disable Veteran Owned Small Business. DRAWINGS This project will utilize AutoCad, version 2015. All VA design guides and requirements can be found online at: http://www.cfm.va.gov/TIL/. Where conflicts occur between VA standards and applicable codes, the most stringent requirement shall govern. All drawings must be bundled using the e-transmit function. SITE AND TOPOGRAPHY SURVEY During the design phase, the A/E will perform a site survey and a topographic survey to facilitate the design. GEOTECHNICAL SURVEY During the design phase, the A/E will perform a site survey and a geotechnical survey to facilitate the design. UTILITY SURVEY During the design phase, the A/E will coordinate with VAMC Staff to obtain utility information to facilitate the design. Otherwise, what is not obtained shall be surveyed to extent necessary by the A/E. A/E shall procure any services (to include, but not limited to electrical, HVAC air and hydronic pre-testing and evaluation) required to adequately test and determine the capacity of the existing utility system. Any information including plans provided to the Design Offeror or A/E is for informational purposes only. Design Offeror or A/E shall confirm in the field any information provided by the VA. ASBESTOS ABATEMENT SURVEY During the design phase, the A/E will perform an asbestos abatement survey to facilitate the design. The AE shall survey the areas of conflict in question to incorporate into the design documents accordingly. FIRE PROTECTION ENGINEER REVIEW & CERTIFICATION The A/E shall have the design plans and specifications reviewed by a registered Fire Protection Engineer (FPE) to ensure the design proceeds in accordance with Life Safety Code (LSC) and applicable National Fire Protection Association (NFPA) codes. The FPE s review comments shall be provided along with each design submittal starting with the 65% Design Development drawings. With the Final 100% Construction Documents submittal, provide a FINAL certification letter from a registered FPE stating that the FINAL plans and specifications are in compliance with the current LSC and NFPA codes. SEISMIC DESIGN In accordance with the VA s manual for Seismic Design Requirements (H-18-8), OBVAMC Shreveport, LA seismicity is identified as being Low (per Table 4: Spectral Response Accelerations at VA Facilities, pg. 23); therefore, seismic design is NOT required. PHYSICAL SECURITY & BLAST DESIGN The design shall be in accordance with the latest edition of the Physical Security Design Manual for VA Facilities, Life-Safety Protected/Mission Critical Facilities as applicable. HANDICAP ACCESSIBILITY The design will be required to comply with the Uniform Federal Accessibility Standards (UFAS), ABAAS (Architectural Barriers Act Accessibility Standards) and PG-18-13 (Barrier Free Design Guide) in all areas. COMMISSIONING The construction and intended use does require commissioning. The A/E shall incorporate the VA s commissioning technical specifications into the design and complete set of construction documents as applicable. The Construction contractor shall procure the independent 3rd party Commissioning Agent to oversee and execute the contract required commissioning activities during Construction. The proposed Commissioning Agent s credentials will be provided to the VA for the VA s approval of the Commissioning Agent. The Design Offeror or A/E shall support and review the commissioning reports as part of construction period services. GOVERNMENT FURNISHED INFORMATION The following is a list of government furnished information found on the VA s Technical Information Library website (http://www.cfm.va.gov/TIL/) to be used for this project, as applicable: PG-18-1 Master Construction Specifications PG-18-3 Design and Construction Procedures PG-18-4 Standard Details and CAD Standards PG-18-10 Design Manuals (by discipline) PG-18-12 Design Guides (graphical, by function) PG-18-13 Barrier Free Design Guides Uniform Federal Accessibility Standards (UFAS) ABAAS (Architectural Barriers Act Accessibility Standards) Physical Security Design Manual for VA Facilities, Life-Safety Protected NOTE: Utilize the latest version of guidance at time of design award. A 2.0 Design Deliverables OBVAMC Design Submissions Statement of Task: Submit Floor Plan/Schematic Design 35% Conceptual Design 65% Design Development 95% Final Development 100% Construction Documents NOTE 1: Additional detailed design submission requirements can be found in VA Guide PG-18-15. NOTE 2: The VA staff shall have 16 calendar days to review and coordinate each complete AE design submission. Floor Plan/Schematic Design: Investigate and survey project site. Verify any VA provided data. AE is responsible for collecting all data required for the design. The A/E is responsible for measuring and collecting actual field data that may be required. The A/E shall collaborate with VA staff/end user (VA Safety Staff) and propose renovation options for review and approval. The A/E shall develop schematic drawings for review. This schematic design phase is an iterative process and requires close coordination with the VA staff. The preliminary schematic design/layout will most likely require changes until a final plan/layout is officially approved by the hospital. AE shall work with the VA staff until acceptable correction plan has been developed and approved in writing by the VA. The AE final deliverables for this phase are (hard and electronic copies): OBVAMC Approved Floor Plan/Location of New Cooling Towers and Generator(s). Provide 3D Renderings Preliminary Cost Estimate (RS Means, Cost Works) List of probable Specification Sections for this project Asbestos Survey HVAC design load calculations for total chiller capacity Electrical Study of existing chilled water and condensing water system 35% Conceptual Design: These drawings shall be at the largest scale possible. Drawings & Specifications: Provide one 22 x34 size set, five 17 x22 size sets, two 11 x17 size sets and one unbound 11 x17 size set of preliminary construction drawings. Provide one set of preliminary specifications indicating all the AE proposed edits double-sided and in a 3-hole punch binder. Drawings and specifications to indicate potential deductive bid alternates and any phasing requirements. Also, provide electronic copies on a CD (Drawings in both AutoCAD (2015) binded and scanned individual PDF files format, Specifications in Word format). Cost Estimate & Design Analysis: Provide a detailed cost estimate indicating labor, material and equipment cost in RS Means CostWorks format. Estimate shall include Prime Contractors (SDVOSB) Overhead, Profit, Bond, and Labor Burden (typically 32%). Estimate shall indicate feasible deductive bid alternates to bring the construction cost within the allotted construction budget. The cost estimate and design analysis shall be submitted in hard copy (double-sided and in a 3-hole punch binder) and an electronic copy on a CD. FPE Certification: Provide an initial review by the Fire Protection Engineer and indicate their comments. 65% Design Development: This submission of drawings, specifications and cost estimate shall be very close to complete. This review by the VA shall be to validate that 35% comments were incorporated into the project. The construction documents should be sufficiently developed to cover all work items to be addressed by the project. No major items missing from this submission. The VAMC review of these documents should result in very minor comments to allow for the next 95% submission. AE shall provide a list of questions by discipline on anything that s needed from the VA to continue and fully develop the next 95% design submission. Additionally, the AE shall provide minutes from the last design review meeting and shall provide responses to all VA comments noted or identified during the last review submission. Drawings & Specifications: Submit in the same manner as the 35% Conceptual Design submittal. Cost Estimate & Design Analysis: Submit in the same manner as the 35% Conceptual Design submittal, except provide two complete sets of specifications and design analysis. FPE Certification: Provide review by the Fire Protection Engineer and indicate their comments. 95% Final Design: This submission of drawings, specifications and cost estimate shall be complete. This review by the VA shall be to validate that 65% comments were incorporated into the project. There shall be nothing missing from the construction documents. The VAMC review of these documents should result in very minor comments to allow for the next submission to be final. AE shall provide a list of questions (which should be very minimal at this point) by discipline on anything that s needed from the VA to finalize and completed the design documents. Additionally, the AE shall provide minutes from the last design review meeting and shall provide responses to all VA comments noted or identified during the last review submission. NOTE: If the VA s review of this set of documents (95%) results in numerous comments, then a 99% review or a check set of certain elements of the design will be required before the AE shall proceed to the 100% Final Construction Documents. Drawings & Specifications: Submit in the same manner as the 65% Design Development submittal. Cost Estimate & Design Analysis: Submit in the same manner as the 65% Design Development submittal. FPE Certification: Provide review by the Fire Protection Engineer and indicate their comments. 100% Construction Documents: This submission shall incorporate all project requirements and previous comments. These documents shall be marked FINAL ready for bidding. Drawings & Specifications: Submit in the same manner as the 95% Final Design submittal. ALL ENGINEERS AND ARCHITECTS PROFESSIONAL STAMPS SHALL BE ON THIS SET OF DOUMENTS. Cost Estimate & Design Analysis: Submit in the same manner as the 95% Final Design submittal and marked FINAL. FPE Certification: Provide a FINAL certification letter from a registered Fire Protection Engineer stating that the FINAL plans (annotate date on Final set of plan) and specifications are in compliance with the current Life Safety Code (LSC) and applicable National Fire Protection Association (NFPA) codes. Electronic Copies: Provide two CD electronic copies of the entire package (Construction Drawings and Specifications). The drawings shall be as both AutoCAD (2015) binded and scanned individual PDF files (coordinate naming of the files with the COR). The specifications shall be in separate WORD format and separate PDF files for each spec section (coordinate naming of the files with the COR). Construction Period Services (CPS): AE shall provide full post design services construction period service IAW the Special Provisions of this contract. PRE-AWARD: CPS s to include assistance with questions, request for information (RFI s), meeting conference calls, clarifications and addendums during the construction solicitation phase. Physical attendance at the Pre-Bid meeting is required. POST-AWARD: CPS s also include full support through the construction phase to include but not limited to, assisting with questions, clarifications, inspections, reviewing and responding to RFI s and review/coordination of contract modifications/change orders. Designing and estimating of design errors or omissions will be performed at no cost to the VA. The Designer shall support and review the commissioning reports. POST-AWARD SITE VISITS: CPS s shall also include a minimum of 15 Site Visits during the construction phase of the project. Type and discipline of site visit shall be determined at the time of need by the COR. ASBUILTS: AE shall also incorporate contractor s asbuilt/redline drawings on AutoCAD (2015) binded and pdf, and provide both electronic (two CD s clearly labeled) and hard copy sets. Hard copy sets of asbuilt drawings shall consist of four 22 x34 size set, five 17 x22 size sets, two 11 x17 size sets and one full size set on mylars.

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 339112
New
Federal
W065--Questions and Responses-Notice of Intent (NOI)-Sole Source-Olympus America, Inc Gastrointestinal Endoscope Medical Equipment Lease Equipment
Solicitation # 36C25627Q0071
The Department of Veterans Affairs Network Contracting Office 16 intends to award a sole-source, firm-fixed-price lease agreement to Olympus America, Inc. for gastrointestinal endoscope medical equipment and accessories to support the Central Arkansas Veterans Healthcare System in Little Rock, Arkansas. This procurement is conducted under FAR Part 8 and FAR Subpart 8.4 via the Federal Supply Schedule, utilizing Olympus Contract 36F79721D0168. The agreement is structured with a base year and four one-year option periods to ensure predictable pricing, reduce administrative burdens, and maintain clinical capability through OEM-authorized maintenance and warranty support. The scope of the lease includes a comprehensive array of proprietary equipment, such as CV-1500 and CV-190 video system centers, UHD 4K monitors, and various specialized endoscopes and cables. To ensure compatibility with existing government-owned scopes, the requirement specifically includes both CV-190/CLV-190 and CV-1500 systems, though consumables are explicitly excluded from the lease. The contractor must be an OEM-authorized dealer, distributor, or reseller with certified technicians to prevent the delivery of gray market items, which would constitute a breach of contract. The anticipated award date is December 31, 2026, under NAICS code 339112.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 4 days
View Details
NAICS: 532490
New
Federal
Mobile CT Scanner for Longview TX VA Medical CBOC
Solicitation # 36C256-27-AP-0375
The Department of Veterans Affairs, through Network Contracting Office 16, is seeking sources for a mobile Computed Tomography (CT) scanner and operating technicians to serve the Longview Community Based Outpatient Clinic in Longview, Texas. The requirement involves providing a fully equipped mobile unit featuring at least a 64-slice CT scanner, with maximum dimensions of 12 feet wide and 50 feet long. The contractor must provide qualified staffing, including a technologist licensed per VA regulations, and is responsible for all maintenance, repairs, and connectivity support. Performance is expected to begin on January 1, 2027, with a contract structure consisting of a 12-month base period and four optional 12-month extension years. The mobile unit must adhere to ADA compliance, including ADA-sized entry doors and dressing rooms, and must be equipped with a patient lift and double-sided handrails. Operations are scheduled Monday through Friday from 8:00 AM to 5:00 PM, following The Joint Commission and VHA directives for radiation protection and privacy. The contractor is required to maintain professional liability, worker's compensation, and property insurance, while ensuring zero breaches of HIPAA and privacy standards. Security requirements include tamper-evident packaging for hardware delivery and mandatory cybersecurity training for personnel. This current effort is a sources-sought notice under NAICS code 532490, and interested firms should contact the Contracting Officer to participate in future requests for quotes.
Other Commercial and Industrial Machinery and Equipment Rental and Leasing

POSTED

2 days ago

DEADLINE

in 4 days
View Details
NAICS: 238210
New
Federal
J061--TRIENNIAL ELECTRICAL MAINTENANCE - AMENDMENT 4 POP: 12/01/2026 - 11/30/2027 PLUS 4 OPTION YEARS
Solicitation # 36C25626Q1011
Solicitation 36C25626Q1011 is a Request for Quotation issued by the Department of Veterans Affairs for triennial electrical distribution system testing and maintenance for the Southeast Louisiana Veterans Healthcare System. The scope of work includes general condition assessments, electrical system analysis, and maintenance of transformers, metal-enclosed busways, and emergency systems, including engine generators and automatic transfer switches. Services will be performed at the New Orleans VA Medical Center and the St. John VA Clinic in Reserve, Louisiana. The contract is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238210. The base period of performance is from December 1, 2026, to November 30, 2027, with four additional option years. This is a Best Value Tradeoff procurement where non-price factors, including technical capability, past performance, and personnel qualifications, are significantly more important than price. Technical evaluations focus on the ability to meet NETA, NFPA, and VA Directive 1028 standards, as well as the capacity to perform night and weekend testing to avoid patient care disruptions. Proposals must be submitted in two separate volumes, technical and price, by November 9, 2026, at 13:00 CST. The contractor is required to maintain professional liability insurance, adhere to Davis-Bacon Act wage standards, and certify at least 51 percent self-performance of the contract.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

2 days ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS