Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

C1DA--589A5-25-150 REPLACE BOILERS FLS| MC FY27 NRM VISN Base DE

Open
36C25527R0017Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

541330 - Engineering Services

Place of Performance

Colmery O'Neil VA Medical Center 2200 Gage Blvd, Topeka, KS, 66622

Set-Aside

VSA

Documents

1
DOCX

Read the document

Due in 16 days

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Due in 16 days

Everything you need to bid on this one

Open the full contract in your free workspace.

  • 1 solicitation documentRead every page
  • Buyer contactEmail and phone
Open the full contract

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhasePresolicitation
Posted

Presolicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA

Full Description

Show more
Presolicitation Notice
Page 1 of
Presolicitation Notice
Presolicitation Notice *=Required Field Presolicitation Notice
Pre-Solicitation Notice: Request for Engineering Services Solicitation: 36C25527R0017, Fire Protection and Life Safety Code Review This acquisition pertains to the engineering services to review the design, construction documents and construction period services per supplement B for project 589A5-25-150 Replace Boilers Fire Life Safety (FLS). The Architect and Engineering contract has been awarded for this project and is currently at the 90% design submission stage.
CONTRACT and TASK ORDER INFORMATION
a. This A/E Services requirement is being procured in accordance with the Brooks Act (Public Law (PL0582) and implemented in accordance with the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected based on demonstrated competence and qualifications for the required work. b. This procurement is restricted to Service-Disabled Veteran Owned Small Business (SDVOSB) firms. This requirement is being procured in accordance with the VAAR Subpart 836.6 as implemented in FAR Subpart 36.6.
c. This is not a Request for Proposal, and an award will not be made with this announcement. This announcement is a request for SF 330s from qualified contractors that meet the professional requirements. d. The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and are listed below in descending order of importance. The completed SF 330 will be evaluated by the Colmery-O Niel VA Medical Center VAMC, Topeka, Ks Evaluation Board in accordance with FAR 36.602-3 and the selection report shall serve as the final selection list, which will be provided directly to the Contracting Officer. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement.
e. Award of any resultant contract is contingent upon the availability of funds.
f. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted via email only to james.petrikva.gov. Personal visits to discuss this announcement will not be allowed.
g. The NAICS Code for this procurement is 541330 Engineering Services and small business size standard of $25.5M. Award of a Firm Fixed Price contract is anticipated. The anticipated time for completion of design is approximately 180 calendar days including time for VA reviews. It is not anticipated that this assessment will be tied to a design project. Construction period services are not required for this procurement.
The NAICS Code for this procurement is 541330, Engineering Services and the small business size standard of 25.5 Million. Award of a Stand Alone Firm Fixed Price contract.
h. DATABASE REGISTRATION INFORMATION: Apparent successful offeror as service-disabled veteran owned small business must be incompliance with VAAR 852.219-73 and must be certified in the SBA certification database at https://veterans.certify.sba.gov.
i. SYSTEM FOR AWARD MANAGEMENT (SAM.GOV): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM.GOV) database at https://sam.gov/content/ and enter all mandatory information into the system. Offerors are encouraged to ensure that they are registered in SAM.GOV prior to submitting their qualifications package.
j. THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at https://sam.gov/content/ for each person providing services under this contract/task order. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities.
k. E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54)
l. A/E firms are required to respond if interested by submitting one (1) completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: https://www.gsa.gov/system/files/SF330-21_Part_1.pdf and SF330-21_Part_2.pdf (gsa.gov)). Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions shall be made electronically. m. Completed package shall be delivered electronically on or before 12/04/2026 at 2:00PM Central Standard Time to the NCO 15 Contracting Office, to the Contracting Officer at Sign up to see this detail.
The SF330s of interested firms will be reviewed. Any additional or supplemental information to be submitted must be in pdf format, not to exceed 10 MB and emailed. Email subject line shall clearly identify Solicitation number: 36C25527R0017 and project name, REPLACE BOILERS FLS, Project No.657A5-25-150.
PROJECT INFORMATION
FIRE PROTECTION ENGINEERING AND LIFE SAFETY CODE REVIEW SERVICES
I. SCOPE OF WORK:
The Department of Veterans Affairs is seeking an independent third-party fire protection and life safety code review for a delegated construction project as required by Veteran Health Administration (VHA) Directive 7712 Fire Protection Code Reviews of Delegated Construction Projects. The review must be performed by qualified Fire Protection Engineers (FPEs) who meet the qualifications and experience requirements outlined in Section IV, Qualifications of this PWS. The contractor shall provide all personnel, equipment, supplies, facilities, tools, materials, supervision, and other items necessary to meet the requirements.
II. DESCRIPTION OF TASKS:
A. General Requirements 1. All written deliverables shall be phrased in layperson s language. Statistical and other technical terminology shall not be used without providing a glossary of terms. 2. The COR and/or CO may require the contractor to meet virtually with the CO, contract administrator, and other government personnel as deemed necessary. The contractor may request a virtual meeting with the COR and/or CO when deemed necessary.
3. The contractor shall provide, via email, minutes of all government-contractor meetings. The contractor shall provide these draft minutes within two business days after completion of the meeting. The government representative will review draft minutes; make edits as appropriate and return to the contractor. Contractor shall have one business day after receipt to finalize minutes and return to the government.
4. The contractor shall ensure contract employees maintain open and professional communication with the staff at the VA facilities. Complaints validated by the COR or VA staff will be reported in writing to the CO for action. If the contractor fails to correct validated complaints raised by the COR and CO to the satisfaction of the COR, it will be considered a failure in performance.
B. The Platform 1. The vendor shall provide a Microsoft compatible web-based collaborative platform accessible to VA staff. The purpose is to provide a platform where the design documents can be uploaded by the VA for contractor review. The platform must be compatible with VA Microsoft Office programs and allow for the transfer of large files from behind the VA Intranet fire wall to the platform. The VA email system will not support this function. The construction project documents to be reviewed include drawings, specifications and other documents.
C. Project Fire Protection and Life Safety (FLS) Review 1. Fire protection and life safety review[s] are to be provided at the 90% design submission level. The VA COR or designated representative will submit a fire protection and life safety (FLS) review request and a set of associated project documents for contractor review when design documents are available.
2. Design review documents could include narratives, specifications, drawings, Requests for Information (RFIs), or other documents. The documents will be provided in electronic format to the vendor via email. See VA Program Guide PG-18-15 for typical A/E Submittal requirements that would be reviewed.
3. The written project review report, referred to as the FLS Review Report, must be developed and submitted by the contractor in editable Microsoft Excel format. Both an Excel file and PDF of the review must be submitted to the VA for each review request. A sample FLS Review Report form must be submitted by the contractor and approved by the COR prior to being used for reviews.
4. The written FLS Review Report must provide both suggested mandatory comments (based on code, standard, or VA requirements) and advisory comments (recommendations) regarding fire protection and life safety. All comments must include a specific section reference to the corresponding NFPA code, standard, VA Fire Protection Design Manual reference, and/or other relevant VA reference material. Any comments that are advisory (recommendations, not mandatory) must be identified as such in the FLS Review Report.
6. The contractor shall ensure that the written project FLS Review Report is reviewed by a secondary qualified Fire Protection Engineer to ensure accuracy; the report must include the names of both the primary and secondary reviewers.
7. The contractor must return the completed report via email to the COR or representative who submitted the request within 10 business days of the contractor s receipt of the submittal package.
8. Where the contractor has performed a previous review of a project and the project is submitted again for review at a later stage of design, the VA COR or facility representative will document the resolutions to the previous comments made by the contractor and will submit that documentation back to the contractor prior to the contractor s subsequent review of the new design submission.
9. Design reviews must include a review of the following items, at minimum: a. Classification of Occupancy (this must be determined before a review can be started) b. Minimum Construction Requirements (and separation) c. Means of Egress i. Components (stairs, ramps, doors, door hardware, etc.) ii. Capacity (Clear Widths) iii. Number of Means of Egress iv. Arrangement v. Travel Distance (including but not limited to exits, within suites, to smoke barriers, etc.) vi. Discharge from Exit vii. Illumination viii. Emergency Lighting ix. Marking Exit Signs x. Suites d. Protection i. Vertical Openings ii. Hazardous Areas iii. Detection/Alarm Systems iv. Suppression / Extinguishment (Sprinklers, extinguishers, clean agent, kitchen, etc.) v. Corridors (Separation, etc.) vi. Subdivision of Building Spaces (Smoke barriers, occupancy separations, etc.) e. Building Services i. Utilities ii. Heating, Ventilation, and Air Conditioning iii. Elevators iv. Chutes f. Design Specifications, if provided g. Narrative, if provided h. Confirmation that a fire protection engineer on the A/E s design team has performed fire alarm, fire suppression, and life safety design for the project.
10. Follow-up technical support shall be provided by the contractor as needed to all facilities to respond to questions regarding the project design review comments.
11. The contractor must inform the VA submitter of potential problems that could interfere with successful completion of the project review within a maximum of three business days after receiving the FLS review request and associated design documents.
III. ACCEPTANCE OR REJECTION OF DELIVERABLES Reports / documents will be accepted by the VA when all discrepancies, errors or other deficiencies identified in writing by the COR, designee or government representative have been corrected. Electronic copies shall be delivered via email to the VA submitter. The contractor shall use best commercial practice for formatting reports and documents. If the government representative finds that the report/document contains spelling errors, grammatical errors, improper format, or otherwise does not conform to the requirements stated in this SOW, the document may be immediately rejected without further review and returned to the contractor for correction and resubmission. IV. QUALIFICATIONS - FIRE PROTECTION ENGINEER
1. The Fire Protection Engineer (FPE) who performs the plan review and authors the FLS Review Report must have the following qualifications: a) Must have obtained an ABET-accredited bachelor s degree in fire protection engineering or a master s degree or other advanced degree in fire protection engineering ( fire safety or similar degrees are not acceptable) b) Must have passed the principles and practices (PE) examination in fire protection engineering c) Must maintain a current United States-based professional engineering license in fire protection engineering. It is understood that some states do not issue dedicated PE licenses in Fire Protection Engineering; in such cases, an individual s state licensure must be predicated upon passing the PE examination in fire protection engineering.
2. Five years of experience in application and interpretation of National Fire Protection Association (NFPA) Codes and Standards and the model building codes.
3. Five years of experience in the design and review of fire suppression and fire alarm systems, including all the following: a. Automatic sprinkler and fire alarm system shop drawings. b. Automatic sprinkler system hydraulic calculations. c. Fire alarm system voltage drops and battery calculations. d. Clean agent systems. e. Standpipe systems.
4. Five years of experience in the application and interpretation of NFPA codes and standards, including, but not limited to, NFPA 1, 3, 4, 10, 13, 14, 17A, 20, 24, 25, 30, 45, 72, 75, 80, 82, 90A, 96, 99, 101, 110, 220, 241 and 2001.
5. Five years of experience in the design of health care facilities on projects of similar relevance and complexity.
6. Five years of experience in acceptance testing fire protection systems.
7. Five years of experience providing fire protection and life safety plan review services for complex health care occupancies (occupancies containing NFPA 101 suites, high-rise buildings, horizontal exits, separated and mixed occupancies, etc.).
Substitution of Personnel All FPEs working on this contract must have their resumes reviewed and approved by the COR and the Contracting Officer. New personnel shall not commence work until all necessary security requirements have been fulfilled, and resumes provided and accepted. The COR or designee will evaluate such requests and promptly notify the contractor of approval or disapproval in writing.
VI. GOVERNMENT AND CONTRACTOR RESPONSIBILITIES The VA COR or government designee will provide the contractor with copies of documents that the VA is legally required to provide. The contractor shall request other VA documentation deemed pertinent to the work directly from the COR, government designee or facility representative. The contractor is expected to use common knowledge and resourcefulness in securing all other reference materials, standard industry publications, and related materials that are pertinent to the work without violating any applicable copyright laws. The most current versions of such documents will be used for all referenced documents. If a version cited in this SOW is updated during the period of performance of this contract, then the most recent / updated version will be applied.
The contractor shall maintain communications with the VA COR, government designee or facility representative as needed to complete the scope of this task. The government will be available for communication (calls, email, etc.) as reasonably needed to complete the scope of this task, subject to COR availability.
The contractor is not required to perform services on the following federal holidays set by law (USC Title 5 Section 6103): New Year's Day Martin Luther King's Birthday Washington's Birthday Memorial Day Juneteenth Independence Day Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day
EVALUATION FACTORS:
Selection criteria are in accordance with Federal Acquisition Regulation (FAR) Part 36.202-4. Additional/supplemental information can be submitted to address all selection criteria provided in this pre-solicitation notice.
Qualifications (SF330) of each interested firm for Project No. 589A5-25-150, will be reviewed and evaluated based on the evaluation criteria listed at section IV of the Statement of Work above.

Similar Contracts

Same NAICS industry code

NAICS: 541330
New
SLED
CR 667 (Cohawkin Road) and CR 673 (Cedar Road) Intersection Improvements in Gloucester County
Solicitation # 27-62-100
The Delaware Valley Regional Planning Commission (DVRPC) is soliciting proposals for a Local Concept Development (LCD) study to implement intersection improvements at CR 667 (Cohawkin Road) and CR 673 (Cedar Road) within the Townships of Mantua and East Greenwich, Gloucester County. The scope of work requires the consultant to evaluate the existing Y-intersection configuration, roadway geometry, line of sight, and traffic operations to improve safety and address vehicle conflicts, while also resolving drainage deficiencies along Cohawkin Road near Heritage Road. The project must adhere to the latest NJDOT Roadway Design Manual and the Controlling Substandard Design Element list. Key deliverables include a final Concept Development Report, with all technical memoranda and reports requiring five color hard copies and electronic versions in PDF and editable formats. GIS data must be projected in NAD83 New Jersey State Plane Feet and NADV 88, and CAD drawings must be submitted in AutoCAD DWG format. The contract is structured as a cost-reimbursable type with a fixed fee, not to exceed. Proposals must be submitted in two separate PDF volumes—a Technical Proposal and an Administrative Cost Proposal—via the OpenGov portal by December 10, 2026. Evaluation is based on professional qualifications, ability to meet the schedule, and technical approach, with the latter weighted at 40% of the total score. The contract will be awarded to the top-ranked firm following a review by an evaluation committee. Bidders must provide a detailed project team description, including qualifications and an organizational chart. While DVRPC complies with Title VI of the Civil Rights Act of 1964 to ensure fair opportunity for disadvantaged business enterprises, there is currently no specific DBE subcontracting goal for this contract.
Transportation Planning

POSTED

about 8 hours ago

DEADLINE

in 22 days
View Details
NAICS: 541330
New
SLED
Planning Study, Contract Documents, And Engineering Support During Construction For The Condition Assessments Of The Downtown Recycled Water Transmission Main And The Camp Pendleton Outfall
Solicitation # 908170821712
The City of Oceanside is soliciting proposals for professional engineering services to conduct a planning study, develop contract documents, and provide optional construction support for condition assessments of the Downtown Recycled Water Transmission Main and the Camp Pendleton Outfall. The primary objective is to evaluate and recommend cost-effective internal and external assessment methods to document pipeline conditions, estimate remaining useful life, and identify necessary repairs. Key deliverables include technical memoranda, a biological and cultural resources constraints study, optional CEQA documentation, and final plans and specifications stamped by a California Registered Professional Civil Engineer. All work must comply with the City of Oceanside Water Utilities Department and Engineers Design and Processing Manuals. Proposals are due by December 16, 2026, and must be limited to thirty one-sided pages, with a separate fee proposal submitted as a distinct document. The contract will be awarded to the responsible and responsive consultant determined to be most advantageous to the agency, with the fee proposal serving only to ensure project understanding rather than as the basis for selection. Selection is based on the entire proposed team, and no changes to key personnel or subconsultants are permitted without prior written approval. Proposers must meet the City's insurance and indemnity requirements to be considered. This solicitation is not set aside for any specific category of business.
City of Oceanside

POSTED

about 10 hours ago

DEADLINE

in 27 days
View Details
NAICS: 541330
New
SLED
Geotechnical Services Consultant Pool
Solicitation # 20261117048
The Irvine Unified School District is seeking to establish a consultant pool of 8 to 15 experienced firms to provide geotechnical services for its PK-12 school facilities across more than 40 sites in Irvine, California. The scope of work includes site analysis, pavement and subgrade recommendations, and construction support for new construction, modernizations, renovations, and expansions. Key deliverables include geotechnical reports signed by a California registered geotechnical engineer or certified engineering geologist, as well as the verification of foundation excavations and controlled fill material. All services must comply with Division of the State Architect (DSA) review and approval requirements. Recommendations for the consultant pool will be based on conformance with the RFQ, firm qualifications and experience specifically related to California PK-12 school facilities, references from California PK-12 districts, past litigation history, and the proposed project team. Interested firms must submit their qualifications by December 16, 2026, at 2:00 pm. Selected contractors must maintain comprehensive general liability, sexual abuse and molestation, and umbrella liability insurance, and must comply with Education Code section 45125.1 regarding criminal records summaries and fingerprinting for personnel interacting with students. Payment for services will be made within 30 days of receipt of a detailed invoice.
Irvine Unified School District

POSTED

about 11 hours ago

DEADLINE

in 28 days
View Details
NAICS: 541330
New
SLED
Commissioning Services Consultant Pool
Solicitation # 20261117046
The Irvine Unified School District is soliciting qualifications to establish a consultant pool of 8 to 15 experienced firms to provide commissioning services for PK-12 school facility projects in Irvine, California. This two-stage selection process first identifies a pool of qualified firms based on their experience with California PK-12 school districts and the Division of the State Architect. Once the pool is established, the District will issue specific Requests for Proposals to a shortlist of typically three to four firms for individual project awards. All services must be performed in accordance with ASHRAE Guideline 0-2005 and the Division of the State Architect High Performance Schools and Collaborative High Performance programs. Qualified firms must submit their responses by 2:00 PM on December 16, 2026. Submittals must include a letter of interest, detailed qualifications, experience, a project team organizational chart, and resumes for all proposed personnel. Key requirements include providing at least three California PK-12 school district references and ensuring team members are certified, licensed, or registered professional engineers in California where required. Additionally, contractors must comply with Education Code section 45125.1 regarding criminal records checks and fingerprinting for any personnel interacting with students. The selected contractors must maintain comprehensive insurance coverage from a California licensed insurer, including a $2,000,000 general aggregate limit, $3,000,000 in umbrella liability, and specific coverage for sexual abuse and molestation. Payment for services will be rendered within 30 days of receipt of a detailed invoice. This solicitation is open to all qualified firms as no specific set-aside status is designated.
Irvine Unified School District

POSTED

about 11 hours ago

DEADLINE

in 28 days
View Details

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 811210
New
Federal
36C25527Q0048 - CT Contrast Injector Maintenance Services
Solicitation # 36C25527Q0048
Solicitation 36C25527Q0048 is a Firm-Fixed-Price contract set aside 100% for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 811210. The Department of Veterans Affairs Network Contracting Office 15 is seeking a contractor to provide full Original Equipment Manufacturer (OEM) maintenance services for Bayer Medrad Stellant FLEX CT contrast injector systems and Certegra workstation platform components. The services will support three devices located at the Marion VAMC and Evansville VA Health Care Center. The scope of work includes annual preventive maintenance, corrective repairs, software updates, system recertification, and cybersecurity hardening consistent with VA directives. The contractor must provide OEM-trained and certified personnel, approved tools, and loaner equipment when clinically necessary. The contract structure consists of a base period from December 7, 2026, to December 6, 2027, with four subsequent one-year option periods extending through December 6, 2031. Performance requirements include a 30-minute window for telephone triage and a four-hour on-site arrival time for urgent clinical outages. Award will be based on the most advantageous offer, considering price, technical capability, and past performance. Technical evaluation focuses on the contractor's experience with the specific Bayer systems, certification of personnel, and a detailed execution plan. Quotes must be submitted as three separate PDF documents covering solicitation and amendments, technical capability, and pricing by the deadline of November 20, 2026.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 12 hours ago

DEADLINE

in 13 days
View Details
NAICS: 541350
New
Federal
H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH
Solicitation # 36C25526Q0617
Solicitation 36C25526Q0617 is a Request for Quotation issued by the Department of Veterans Affairs, Network Contracting Office 15, for an Indefinite-Delivery, Indefinite-Quantity (IDIQ) firm-fixed-price contract. The project requires comprehensive inspection, preventive maintenance, and repair services for approximately 124 manual fire and smoke door assemblies and 57 automatic door systems at the Dwight D. Eisenhower VA Medical Center in Leavenworth, Kansas. The scope of work includes semiannual or annual inspections, functional testing, and on-call repair services in compliance with NFPA 80, NFPA 101, and NFPA 105 standards. The contract is structured with five ordering periods, with an initial period estimated from November 1, 2026, through October 31, 2027, and a final performance deadline of April 30, 2032. This procurement is a total small business set-aside under NAICS 541350. Award will be based on the most advantageous offer, evaluating technical capability, past performance, veterans involvement, and price. Key technical requirements include the use of AAADM-certified personnel for automatic doors and strict adherence to emergency response times, requiring a technician on-site within four hours for life-safety emergencies. Amendment 0004 has extended the quote submission deadline to November 20, 2026, at 3:00 PM CST. Offerors must submit their quotes via email to the contracting officer and acknowledge all amendments using the SF30 form.
Building Inspection Services

POSTED

about 12 hours ago

DEADLINE

in 9 days
View Details
NAICS: 238210
New
Federal
657A5-26-111, Triennial Electrical Testing
Solicitation # 36C25526R0186
The Department of Veterans Affairs Network Contracting Office 15 is soliciting a Service-Disabled Veteran Owned Small Business (SDVOSB) set-aside contract for triennial electrical testing at the Marion VA Medical Center in Marion, Illinois. The project, identified as 657A5-26-111, involves the maintenance, inspection, adjustment, and testing of the facility's electrical power distribution system. The scope of work includes testing approximately 325 electrical panels, 15 medium voltage transformers (10 oil-type and 5 dry-type), 120 low voltage dry-type transformers, 220 fused or non-fused switches, 6 generators, and 25 automatic transfer switches. All work must adhere to the 2019 NETA Maintenance and Testing Specifications and the latest National Electrical Code. The contract is estimated to have a value between $500,000 and $1,000,000 with a performance period of 150 days. Award will be based on the Lowest Price Technically Acceptable (LPTA) process, evaluating factors such as the prime contractor's past performance and technical experience, the electrical subcontractor's experience, staffing qualifications, and a safety plan. Technical requirements mandate that field work be supervised by a Certified Electrical Testing Technologist with at least five years of experience. The contract is subject to Construction Wage Rate Requirements and the Buy American Requirement for construction materials. Proposals must be submitted in three volumes covering technical specifications, pricing, and a bid bond.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in about 21 hours
View Details
NAICS: 562910
New
Federal
J091--Aboveground Fuel Tank Inspection Services - Kansas City VAMC
Solicitation # 36C25527Q0047
The Department of Veterans Affairs is soliciting a five-year Indefinite-Delivery, Indefinite-Quantity (IDIQ) contract for aboveground fuel tank inspection and maintenance services at the Kansas City VA Medical Center. This total SDVOSB set-aside procurement, under NAICS 562910, requires a qualified contractor to provide annual inspection, repair, certification, and fuel oil filtering for sixteen aboveground storage tanks with capacities of 55 gallons or greater. The period of performance runs from January 19, 2027, to January 18, 2032, with the requirement that annual inspections be completed every February. The scope of work includes STI SP001 certification for all tanks, fuel oil filtration to a specification of 4–10 ppm, and the annual application of stabilizer and biocide to maintain a minimum diesel cetane rating of 40. The contractor is responsible for all labor, materials, and the legal disposal of fuel, water, and filtration waste, including the provision of manifests and chain of custody documentation. All work must comply with API 653, EPA 40 CFR Part 112, NFPA 110 Chapter 8, and OSHA 29 CFR 1910 standards. Award will be based on a best-value comparative analysis of price, technical capability, and past performance, with a firm-fixed-price structure. Eligible offerors must provide a certified inspector with STI SP001 or API 653 certification and maintain general liability and pollution liability insurance. Proposals must be submitted by December 11, 2026, and must include a detailed price response and a non-price response covering technical eligibility, waste handling procedures, and socio-economic status.
Remediation Services

POSTED

1 day ago

DEADLINE

in 23 days
View Details
NAICS: 541330
New
Federal
C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)
Solicitation # 36C25527Q0057_1
The Department of Veterans Affairs Network Contracting Office 15 is conducting a market survey for a Service-Disabled Veteran Owned Small Business (SDVOSB) to provide professional design services to correct electrical deficiencies in Building 26 at the Kansas City VA Medical Center. The scope of work involves addressing deficiencies in electrical closets, secondary distribution, uninterruptible power, and emergency power. The selected Architect/Engineer will be responsible for site visits, field investigations, and the preparation of narratives, studies, and design documents. Deliverables include design drawings, specifications, and Independent Government Cost Estimates (IGCE) submitted at 35 percent Schematic Design, 65 percent Design Development, 95 percent Construction Documents, and Final Bid Documents. All work must comply with Infection Control and Interim Life Safety Measures, and the period of performance for design work is 150 calendar days. This opportunity is a Sources Sought notice for market research purposes under NAICS code 541330, Engineering Services, with a size standard of 25.5 million dollars. Interested SDVOSB firms must be registered in SAM.gov and the SBA registry. To be considered, firms must submit a capability statement of no more than 10 pages by December 1, 2026, at 2:00 PM Central Time. This statement must include company contact information, Unique Entity ID, CVE certification, and evidence of comparable work performed within the last five years. In accordance with VAAR 852.219-75, the prime contractor must certify that no more than 50 percent of the government payment will be paid to firms that are not certified SDVOSBs.
Engineering Services

POSTED

1 day ago

DEADLINE

in 13 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Get AI-powered intelligence on this solicitation and the ones like it

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS