Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 14 at 2:00 PM EDT

Register Free →

Columbia Pool Exhaust Fan

Active
CP 25-056State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Columbia Pool Exhaust Fan project (Project No. CP 25-056) is a public construction solicitation issued by the City of Turlock, California, with an engineer's estimate of $67,500. The scope of work requires a contractor to provide all labor, materials, and equipment to install an inline exhaust fan system, perform gas line updates, and complete electrical updates. Key technical requirements include providing electrical connections for equipment exceeding 50V, installing low voltage control raceways, and performing necessary site excavation and restoration. All work must comply with the California Building Code, California Electrical Code, and CALTRANS standard specifications for concrete. Proposals are due by 3:00 pm on October 21, 2026, via the OpenGov Procurement Portal. Bidders must submit a bid bond of at least 10% of the total bid, and the successful contractor will be required to provide performance and payment bonds equal to 100% of the contract price. The project mandates compliance with Stanislaus County prevailing wage rates and CAL/OSHA safety regulations. Additionally, contractors must submit a quality-control plan within 10 days of the Notice to Proceed and provide detailed documentation regarding Disadvantaged Business Enterprise (DBE) utilization and good faith efforts.

Documents

(14)

City of Turlock Public Improvement Agreement - Columbia Pool Exhaust Fan

PDF•contract-document

Columbia Pool Exhaust Fan Notice to Contractors and Proposal

PDF•ifb

Columbia Pool Exhaust Fan Project Plans

PDF•sow

Exhibit 12-B Bidder’s List of Subcontractors

PDF•sow

Exhibit 15-H Proposer/Contractor Good Faith Efforts

PDF•sow

Licensees Responsible for Specifications

PDF•specifications

Subcontractors Listing Form for California Public Contract

PDF•1 page•subcontractors-listing

Technical Specifications - Columbia Pool Exhaust Fan

PDF•sow

Affidavit of Non-Collusion for Bid Submission

PDF•1 page•affidavit

Bidder's Bond for City of Turlock Project

PDF•bond

Disadvantaged Business Enterprises (DBE) Certification Status Change Instructions

PDF•2 pages•other

Disclosure of Lobbying Activities SF-LLL

PDF•2 pages•disclosure-of-lobbying-activities

Exhibit 15-G Construction Contract DBE Commitment

PDF•form

Exhibit 17-F Final DBE Utilization Report

PDF•form

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Municipal Services-Engineering
Contacts2 people available
OfficeTurlock, CA, 95380, USA
Office AddressTurlock, CA, 95380, USA
Contacts
Julian AvilaAssociate Civil Engineer
Gloria AguileraStaff Services Assistant

Interested Companies (2)

Show more

Full Description

Show more
The Engineer's Estimate is $67,500.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
CBP: Replacement Fiber Line
Solicitation # CBP: Replacement Fiber Line
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to replace existing multi-mode fiber optic cabling with 12 strand single mode fiber optic cabling at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The project involves removing retired aerial fiber lines and splice boxes from utility poles and building 2436, and installing new Belden FS3L0024NS 12 strand OS2 OSP fiber or an equivalent brand to provide network connectivity between the building 2436 network closet and the building 2443 maintenance office. The contractor is responsible for providing all labor, equipment, and materials, including fiber supports, ends, a rack-mounted enclosure, an adapter panel, and lift rentals. Bids are due by October 5, 2026, and must include a signed bid form and a detailed cost breakout on company letterhead. A physical site visit and signature on the attendance roster are mandatory prerequisites for bid submission. Awards will be based on overall best value, and bidders must provide a bid bond guarantee, cashier's check, or money order to be considered. Performance and payment bonds from a surety with at least an A- rating are required for contracts valued at $25,000 or more. This opportunity is set aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB. Contractors must provide a Unique Entity ID and comply with FAR regulations regarding business size certification and debarment disclosure. The project is subject to Davis-Bacon Act prevailing wage rates for building construction in Kentucky and requires adherence to strict government security and confidentiality standards for protecting sensitive information. Final acceptance of work is contingent upon satisfactory workmanship and the completion of all punch list items as approved by center and government representatives.
Earle C. Clements Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in 5 days
View Details
NAICS: 238210
New
SLED
W Magnolia S PF Lighting Replacements
Solicitation # PW#2025-077
Solicitation PW#2025-077 is a public works project for the City of Seattle to replace lighting at the Magnolia Playfield located at 2518 34th Ave W, Seattle, WA. The scope of work involves the demolition and hauling of existing wooden flood light poles and fixtures, with a specific requirement for the contractor to test for and appropriately dispose of potentially contaminated materials such as Pentachlorophenol or Chromated Copper Arsenate. The project includes the installation of new shielded LED floodlights, poles, conduit, wiring, junction boxes, and receptacles, as well as the replacement of electrical panels, circuit breakers, and the lighting control panel. Additionally, the contractor is responsible for necessary tree pruning to ensure proper lighting operation and installation. The engineer's estimate for the project is $1,219,433.60. The contract will be awarded to the apparent low bidder who meets all mandatory responsibility criteria. Bids must be submitted electronically via OpenGov and include a bid guaranty of five percent of the total bid, an inclusion plan, and a bidder/subcontractor list. Performance is subject to coordination with active game and event schedules at the playfield, with a maximum of two one-week shutdowns permitted upon approval. The contractor must comply with Washington State prevailing wage requirements, provide a critical path method schedule via Procore, and adhere to strict material handling and quality standards. Key administrative requirements include the submission of a Social Equity Plan by the apparent low bidder and electronic invoicing submitted to the Department of Finance and Administrative Services.
Public Works

POSTED

about 15 hours ago

DEADLINE

in 21 days
View Details
NAICS: 238210
New
Federal
Air Compressor Relocation
Solicitation # N0017326Q1905
Solicitation N0017326Q1905 is a firm-fixed-price requirement issued by the Naval Research Laboratory for the relocation of two SULAIR Model 3709B AC air compressors from mechanical room 026B to a new exterior location at Building 65 in Washington, DC. The scope of work includes the construction of a 10 by 21 foot metal shed featuring a 4000 PSI concrete slab, LED lighting, and a 13,300 CFM exhaust fan. The contractor is responsible for extending 3 inch copper compressed air piping, installing a new 208V-120V panel board, and extending Siemens BAS wiring using rigid galvanized conduit. All work must adhere to NEC, NFPA 72, and UFC standards, with strict compliance to EM 385-1-1 and OSHA safety regulations. A critical requirement is the submission of a construction-phasing plan to ensure at least one compressor remains operational throughout the process. This procurement is a total small business set-aside and will be awarded based on the Lowest Price Technically Acceptable process. To be considered acceptable, offerors must complete a mandatory site visit and provide a technical quote and past performance record. The period of performance is scheduled from September 30, 2026, to December 4, 2026. Proposals must be submitted electronically in three separate volumes, with a total page limit of 45 pages. Final acceptance is contingent upon a walkthrough and the resolution of any punch list deficiencies within 30 days. Invoicing and payments will be processed electronically through the Wide Area WorkFlow system.
Naval Research Laboratory

POSTED

about 17 hours ago

DEADLINE

in 16 days
View Details
NAICS: 238210
New
Federal
J061--TRIENNIAL ELECTRICAL MAINTENANCE FY26 AMENDMENT #3 Q&A RESPONSE, SCOPE UPDATE, DRAWINGS AND PANEL LISTS NEW DEADLINE: 10/27/26 POP START DATE: 12/01/2026
Solicitation # 36C25626Q1011
Solicitation 36C25626Q1011 is a Request for Quotation issued by the Department of Veterans Affairs for triennial system testing and electrical maintenance of the entire electrical distribution system for the Southeast Louisiana Veterans Healthcare System. The scope of work covers three locations: the New Orleans VA Medical Center, the St. John VA Clinic in Reserve, and the Hammond VA Clinic. Requirements include testing of medium and low voltage systems, electrical studies, infrared scans, and maintenance of operating room LIM panels. The project is 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238210. The base period of performance is from November 1, 2026, through October 31, 2027, with four additional option years. The procurement follows a Lowest Priced Technically Acceptable process, evaluating offers based on technical capability and price. Technical requirements include providing qualified personnel, such as a Supervising Field Service Engineer accredited as a Certified Electrical Test Technologist by NICET, and demonstrating sufficient capacity and quality control policies. Proposals must be submitted in two separate volumes, technical and price, via email to the contracting specialist by October 2, 2026, at 13:00 CST. Contractors must comply with the Davis-Bacon Act and specific VAAR professional liability insurance requirements. Award will be made to the lowest evaluated price among proposals that meet the minimum technical acceptability standards.
256-NETWORK Contract Office 16 (36C256)

POSTED

about 17 hours ago

DEADLINE

in 27 days
View Details
NAICS: 238210
New
Federal
REQUEST FOR QUOTES - RENTAL OF UPS FOR PHONE ROOM
Solicitation # 36C24526Q0840
Solicitation 36C24526Q0840 is a firm-fixed-price request for quotes issued by the Department of Veterans Affairs for the Louis A Johnson VA Medical Center in Clarksburg, West Virginia. The project requires the delivery, installation, and start-up of a new 80 kVA UPS system, including the demolition and removal of the existing Liebert UPS. To ensure continuous power during the transition, the contractor must provide a temporary UPS rental for up to six months or until the permanent system is fully operational. The contract includes a minimum 12-month warranty on all materials and workmanship and requires strict adherence to NFPA 70E and IEEE 1584 standards for electrical labeling and hazard analysis. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with a response deadline of October 2, 2026. Award decisions will be based on a combination of price, technical ability, and past performance. Qualified offerors must demonstrate at least five continuous years of experience in UPS rental and installation, hold a valid electrical license, and possess certifications for Liebert/Vertiv or similar systems. Additional requirements include OSHA 10/30 and NFPA 70E certifications, as well as compliance with Service Contract Act wage determinations for West Virginia. All work must be performed in accordance with VHA Directive 1028 regarding facility electrical power systems and VHA Directive 7701 for occupational safety.
245-NETWORK Contract Office 5 (36C245)

POSTED

1 day ago

DEADLINE

in 1 day
View Details
NAICS: 238210
New
Federal
J059--Albany Transformer Testing & Service
Solicitation # 36C24226Q0928
Solicitation 36C24226Q0928 is a request for quotation issued by the Department of Veterans Affairs Network Contracting Office 2 for the onsite inspection and testing of medium voltage electrical transformers at the Samuel S. Stratton VA Medical Center in Albany, New York. The scope of work includes infrared scanning, oil sampling, and general testing and reconditioning of components to ensure equipment reliability and minimal downtime. All work must be performed in accordance with NFPA 70B and VHA directive 1028 under the supervision of a Qualified Registered Professional Engineer. The period of performance for these annual services is scheduled from November 1, 2026, to December 31, 2026. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238210. To be eligible for award, the contractor must be a NETA certified Electrical Test Technologist, and the supervising Field Service Engineer must hold accreditation from NICET or NETA with at least five years of experience on similar projects. Offers will be evaluated based on technical proficiency, firm experience, certifications, a management plan, past performance, and total price. Additionally, awardees must comply with strict subcontracting limitations, certifying that no more than 50 percent of the contract value is paid to firms that are not certified SDVOSBs or VOSBs.
242-NETWORK Contract Office 02 (36C242)

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 238210
New
Federal
Fire Alarm and Mass Notification System Upgrades for DDJC, Tracy, CA
Solicitation # W9123826RA002
Solicitation W9123826RA002 is a construction procurement issued by the USACE-SPK Contracting Division for the upgrade of Fire Alarm and Mass Notification Systems at DDJC in Tracy, California. The contractor is required to provide all labor, materials, equipment, and supervision to design, supply, and integrate existing Gamewell fire alarm controls, Federal Signal mass notification/voice evacuation, and King Fisher radio transceivers into a single panel for approximately 49 buildings and warehouses. Additionally, the scope includes replacing the central receiving system in Building 235 and establishing a backup receiving system in Building 100. The project is structured with firm-fixed-price line items covering design, cybersecurity, and construction. The project mandates a high level of technical and administrative compliance, including CMMC Level 1 certification for cybersecurity and adherence to the Buy American Act. Key personnel requirements include on-site roles for a Project Superintendent, CQC System Manager, Safety Manager, and Site Security Manager. The government utilizes a three-phase inspection process, and full compensation is contingent upon successful system integration, acceptance testing, commissioning, and operator training. Contractors must use the Resident Management System for invoicing and adhere to Davis-Bacon wage requirements and EM 385-1-1 safety standards. Submission of the offer requires a bid guarantee and the provision of performance and payment bonds.
W075 Endist Sacramento

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 238210
New
Federal
Z1DA--CON-NRM-663A4-24-209 Replace Fire Suppression Systems BLDG 61
Solicitation # 36C26027Q0051
The Department of Veterans Affairs, VISN 20, is conducting market research through a Sources Sought Notice to identify viable construction sources for Project 663A4-24-209 at the Puget Sound Health Care Systems, American Lake Campus in Lakewood, Washington. The project involves the comprehensive replacement of fire suppression and fire alarm systems in Building 61, including the installation of a new fire alarm control panel in Building 62. The scope of work encompasses the removal and disposal of existing equipment, replacement of the dry-pipe sprinkler system in the attic, installation of a new nitrogen generator, and the replacement of sprinkler heads across three floors. All new installations must integrate seamlessly with existing campus monitoring and BACnet communications protocol controls. The estimated magnitude of this project is between $1,000,000 and $5,000,000, with an intended period of performance of 365 calendar days from the notice to proceed. This effort is categorized under NAICS code 238210 with a size standard of $19 million and is intended as a Service-Disabled Veteran-Owned Small Business set-aside. Interested parties must submit a capability statement, including bonding capacity and socio-economic status, by October 8, 2026. The contractor will be required to adhere to strict VA infection control and safety policies, manage all hazardous material abatement, and provide a Construction Quality Control Manager to oversee performance and government inspections.
260-NETWORK Contract Office 20 (36C260)

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown