Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

Electrical System Maintenance in IDF Rooms

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Alabama → Capitol Maintenance & Repair _ ABRFAView Agency

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

AL, USA

Set-Aside

NONE

Documents

This scope was carved out of SRC0000035594.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

SERV26*375253 Fire Alarm Battery Replacement LBW

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyAlabama → Capitol Maintenance & Repair _ ABRFA
ContactsNo contacts available
OfficeN/A
Organization / Agency
Alabama → Capitol Maintenance & Repair _ ABRFA
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Inspection, maintenance, and potential replacement of electrical components in IDF rooms across all building floors, including integration of battery systems.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
ASO-1286-00 Site renovations at the Air Traffic Control Beacon Interrogator (ATCBI) tower at QRB, Samberg, TN
Solicitation # aso-1286-00-site-renovations-air-traffic-control-beacon-interrogator-atcbi-tower-qrb-samberg-tn
This solicitation, managed by PTSI Managed Services, Inc., involves comprehensive site renovations at the Air Traffic Control Beacon Interrogator tower located in Samberg, Tennessee. The scope of work includes extensive electrical upgrades, such as replacing interior, stair, and exterior lighting with LED fixtures, as well as replacing a restroom exhaust fan. Structural and facility improvements consist of installing a new shelter roof, replacing a small awning, sealing foundation cracks to prevent water intrusion, and repairing or replacing rusted tower components. Additionally, the project requires the replacement of a 10x16 storage shed, repairs to the asphalt parking area, partial replacement of approximately 750 feet of fencing and barbed wire, and the relocation of the entrance gate by six feet. The contract is categorized under NAICS code 238210 and is set aside for Small Businesses and Small Disadvantaged Businesses. Interested parties must submit their responses by the deadline of September 25, 2026. The project is being coordinated through PTSI Managed Services, Inc., with specific inquiries directed to the designated point of contact. This renovation project aims to modernize the facility's lighting, enhance structural integrity, and improve overall site security and utility.
PTSI Managed Services, Inc

POSTED

about 4 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 238210
New
MAIN GROUNDING ELECTRODE
Solicitation # WL-26-006
This solicitation, identified as WL-26-006, is for a single lump sum contract to provide licensed electrical contracting services at the Woodland Job Corps Center in Laurel, Maryland. Operated by Adams and Associates, Inc. for the U.S. Department of Labor, the project requires the inspection and correction of grounding systems across multiple campus buildings, including the Aspen, Holly, Maple, and Oak Dorms, the Vocational Building, Willow Hall, and the Administration Building. The scope of work involves specific technical requirements such as installing #2/0 awg conductors, ground bars, and ground rods, as well as routing conductors in EMT conduit to ensure full compliance with NEC 2023, 250 standards, EPA regulations, OSHA safety requirements, and Maryland state codes. The contract is set aside for various small business categories, including Women-Owned, HUBZone, and Service-Disabled Veteran-Owned Small Businesses. Proposals must be submitted by September 3, 2026, and will be evaluated based on a best-value determination using weighted factors: Price (60%), Quality (20%), Past Performance (10%), and Schedule (10%). Bidders must provide a detailed cost breakdown of labor, materials, and equipment, along with a 90-day bid guarantee and proof of Maryland contractor licensure. Required documentation includes insurance certificates meeting specific liability limits, a completed vendor questionnaire, W9, and small business certifications. Successful contractors must adhere to strict security protocols, comply with latest wage rate decisions, and provide a one-year guarantee on all workmanship.
Adams & Associates\ Woodland Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 10 days
View Details
NAICS: 238210
New
PANELBOARDS
Solicitation # WL – 26 -0004
This solicitation, identified as WL-26-0004, is a subcontracting opportunity for electrical panelboard repairs and labeling at the Woodland Job Corps Center in Laurel, Maryland. Operated by Adams and Associates, Inc. for the U.S. Department of Labor, the project requires electrical work across multiple campus buildings, including Elm Hall, Birch Hall, the Vocational building, Willow, and Mahogany. Key technical tasks include providing non-handwritten circuit directories, updating panel schedules, reinstalling panelboard covers in the welcome center mechanical room, and performing specific UL-listed red mark labeling on the fire alarm control panel breaker at the Oak Dormitory. All work must comply with NEC 2023 standards, as well as OSHA, EPA, and applicable Maryland state and local regulations. The contract is a single lump sum agreement with a performance period spanning from May 11, 2026, through December 31, 2026. This is a set-aside for various small business categories, including Women-Owned, HUBZone, and Service-Disabled Veteran-Owned businesses. Proposals must be submitted by September 3, 2026, and must include a detailed cost breakdown, proof of Maryland contractor licensing, insurance certificates meeting specific liability limits, and certification of compliance with local wage rate decisions. Evaluation will be based on a best-value determination, weighing technical quality, management capabilities, and personnel qualifications against price. Mandatory attendance at a bid conference is required for eligibility, and the contractor must provide a one-year workmanship guarantee. Final payment is contingent upon the submission of certified payroll records, lien releases, and other specific administrative documentation.
Adams & Associates\ Woodland Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 10 days
View Details
NAICS: 238210
New
Wind River Job Corps: LAWN EQUIPMENT STORAGE ROOM VENTILATION
Solicitation # wind-river-job-corps-lawn-equipment-storage-room-ventilation
Arbor E & T, LLC, doing business as Equus Workforce Solutions, has issued a subcontracting solicitation for the Wind River Job Corps Center in Riverton, Wyoming, to address a life safety deficiency. The project involves installing a mechanical ventilation system in a lawn equipment storage room to mitigate the accumulation of dangerous fuel vapors. The scope of work includes creating an 18-inch by 18-inch opening in an exterior concrete block wall, installing a wall-mounted, explosion-proof exhaust fan capable of 600 CFM, and installing two 18-inch by 24-inch door-mounted ventilation louvers. Additionally, the contractor must provide electrical power, conduit, and wiring for a 208-volt motor, ensuring all work adheres to the National Electrical Code and includes operational start-up testing and the provision of manufacturer warranties. This is a fee-for-service opportunity set aside for various small business categories, including Small Disadvantaged, Women-Owned, HUBZone, Veteran-Owned, and Service-Disabled Veteran-Owned small businesses. Bidders must operate under NAICS code 238210 and comply with the Service Contract Act, specifically adhering to Wage Determination No. 2015-5407 for the Wyoming region. Required submission documents include a completed bid sheet, a W-9, a vendor self-certification form, and signed terms and conditions. Proposals must be submitted electronically to the designated contracting officer no later than 2:00 PM MST on September 2, 2026. The award will be based on best value, and subcontractors are responsible for maintaining required insurance, complying with federal labor standards, and fulfilling reporting requirements under the Federal Funding Accountability and Transparency Act.
EQUUS Workforce Solutions operator of the Wind River Job Corps

POSTED

about 4 hours ago

DEADLINE

in 9 days
View Details
NAICS: 238210
New
Electrical Repair Services
Solicitation # Electrical Services 8-2026
The Centennial Job Corps Center, operated by Management and Training Corporation on behalf of the U.S. Department of Labor, has issued a solicitation for electrical repair services in Nampa, Idaho. This fixed-price, single lump sum contract is estimated to be valued between $25,000 and $100,000. The project is subject to various small business set-asides, including Small Disadvantaged, Women-Owned, HUBZone, and Veteran-Owned businesses. A pre-bid meeting is scheduled for August 21, 2026, and all formal bids must be submitted via email to the designated point of contact no later than August 31, 2026, at 3:00 PM MST. Contractors are required to adhere to strict labor and administrative standards, including compliance with the Construction Wage Rate Requirements (formerly the Davis-Bacon Act) using the provided wage determination for Canyon and Gem Counties. For bids of $25,000 or more, bidders must provide a 20% bid bond guarantee, and the awarded contractor must provide performance and payment bonds from an A-rated surety company. The scope of work includes all necessary incidental work and the acquisition of required building permits, with a mandatory one-year written guarantee of workmanship upon completion. Successful bidders must also provide detailed operation and maintenance manuals and manufacturer warranties during the closeout process. Payment will be made through progress payments based on submitted pay applications and certified weekly payrolls.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 7 days
View Details

More opportunities from Alabama → Capitol Maintenance & Repair _ ABRFA

Same awarding agency

New
SLED
SERV27*375323Gate Arms & Roll Up Doors Maintenance Agreement
Solicitation # SRC0000035604
The State of Alabama, through Capitol Maintenance and Repair, is soliciting bids for a 12-month contract to provide preventative maintenance and miscellaneous repairs for roll-up doors, security grills, and gate arm operators. The service period runs from October 1, 2026, through September 30, 2027, covering five specific facilities in downtown Montgomery: the Administrative Building, Annex Building, Alabama Archives and History Building, Folsom Administration Building, and Gordon Persons Building. The contract has a total value ceiling of 25,000 dollars and may be renewed annually for up to five years. Bidders must possess at least five years of relevant experience, provide three professional references, and attend a mandatory site visit on August 28, 2026. Proposals must include quarterly maintenance pricing per facility, hourly labor rates for repairs, and a percentage discount for materials. The selected contractor must provide all labor, equipment, and supervision, strictly adhering to OSHA regulations and professional conduct standards. Notably, the use of subcontractors is prohibited, and the contractor must respond to emergency repair notifications within 24 hours if facility security or ingress/egress is compromised. Compliance with the Beason-Hammon Act via E-Verify and registration in the Alabama Buys portal are mandatory requirements for award.

POSTED

about 4 hours ago

DEADLINE

in 9 days
View Details
New
SLED
SERV26*375271 Fire Alarm Battery Replacement FB
Solicitation # SRC0000035596
This solicitation, identified as SERV26*375271, outlines requirements for fire alarm maintenance and repairs at the Folsom Building located at 64 North Union Street in Montgomery, Alabama. The primary scope of work involves replacing batteries for six different fire alarm panels located throughout the facility, including the penthouse, basement, and various floors. Additionally, the project requires the removal of an old smoke detector on the 6th floor, the installation of a wall strobe in the 1st-floor men's restroom, and the replacement of several ceiling-mounted speakers and strobes in specific suites using customer-provided parts. Technical troubleshooting is also required for a door holder in the 1st-floor Ripley Street Wing lobby and the 4th-floor lobby interface, which may necessitate coordination with handicap door and access control companies as well as JCI programming. Bidders are required to provide unit pricing for twelve specific batteries of varying voltages and capacities, along with a quoted labor rate and a trip charge. The solicitation was posted by the Alabama Capitol Maintenance and Repair agency, with a response deadline of August 27, 2026. Interested parties must submit their quotes according to the specified line items to ensure compliance with the procurement process. For technical inquiries regarding the scope of work, contact is directed to Johnny Willis.

POSTED

about 4 hours ago

DEADLINE

in 3 days
View Details
New
SLED
SERV26*375253 Fire Alarm Battery Replacement LBW
Solicitation # SRC0000035594
Solicitation SRC0000035594, issued by the Alabama Capitol Maintenance and Repair agency, seeks a contractor to replace fire alarm panel batteries at the Lurleen B. Wallace Building located at 501 Dexter Avenue in Montgomery, Alabama. The scope of work includes replacing batteries across all floors from the 1st through the 9th, specifically requiring sixteen 12V 25Ah batteries and two 12V 75Ah batteries. The contractor must also address specific facility issues, including verifying smoke detector requirements for IDF Room 4.2 on the 4th floor, noting the absence of fire fighter phones in elevators 1-4, and addressing a non-functional air handler shutdown function in the 9th floor North Mechanical Room. Bidders are required to provide unit pricing for the batteries, as well as labor rates and trip charges. The contract is governed by Alabama state law and includes a not-to-exceed ceiling of 25,000 dollars, with a potential term of up to five years through annual renewals. Award is implied to be based on the lowest price technically acceptable criteria. Mandatory compliance requirements include E-Verify enrollment, Alabama sales tax registration, and certification that the entity is not debarred or suspended. All proposals must be submitted electronically via the Alabama Buys portal by the deadline of August 27, 2026. Inspection and final acceptance of the work will be conducted by the State of Alabama at the place of performance upon satisfactory completion of the battery replacements and system verification.

POSTED

about 5 hours ago

DEADLINE

in 3 days
View Details