This contract, issued by the FDA Office of Acquisitions and Grant Services, seeks the procurement of a fully functional endoscopy system to support scientific research and the development of bench testing methods for evaluating endoscopy devices. The required system must include an interoperable video processor, colonoscope, medical display, and cart. Key technical specifications include an FDA-cleared 510(k) video processor with integrated LED light sources, narrow-band imaging, and digital color enhancement, as well as a 4K medical display of at least 32 inches. The colonoscope must feature a forward view, a field of view of 170 degrees or wider, and specific angulation and diameter requirements. The successful contractor must deliver the system to the FDA facility in Silver Spring, Maryland, within six weeks of the contract award. The total purchase price must include all shipping costs. Additionally, the system must be supported by a comprehensive one-year warranty covering all parts, labor, travel, and shipping to maintain original equipment manufacturer standards. All components must be compatible with standard U.S. power specifications of 120 volts and 60 Hertz.
General Info
Agency
NAICS
Place of Performance
Silver Spring, MD, 20993, USASet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
Under FDA guidance, this OSEL-DIDSR collaboration requires an endoscope to maximize scientific research capacity throughout the center and agency. An endoscope allows OSEL researchers to develop bench testing methods for evaluating the safety and effectiveness of endoscopy devices.
The Government requires an endoscope system (Endoscope) with the following minimum requirements:
- The Endoscope shall be shipped to the following address:
Attention to: TBD
10903 New Hampshire Ave WO62-3133, US FDA
Silver Spring, MD 20993-
- Shipping cost is included in the total purchase price.
- The Endoscope shall include the video processor, colonoscope, medical display, and cart that are interoperable with each other. Once assembled, these components shall operate as a fully functional endoscopy system that can acquire and display live image.
- The video processor shall satisfy the following requirements:
- The video processor shall be an FDA-cleared 510(k) medical device. The database is publicly available at 510(k) Premarket Notification.
- The light source shall be integrated within the video processor.
- The light source shall use three (3) or more LEDs to synthesize different spectra.
- The video processor shall have the white light mode.
- The video processor shall have two (2) or more narrow-band imaging (NBI) modes that utilize different optical spectra generated by the LED-based light source. The NBI modes shall be FDA-cleared for visualizing biological features such as blood vessels or mucosal surfaces.
- The video processor shall have two (2) or more digital color enhancement modes that utilize different digital image processing techniques. These color enhancement modes shall be FDA-cleared under the FDA product code “PEA”.
- The video processor shall have the following video output ports and video formats:
- 12G-SDI (3840x2160x60p)
- 3G-SDI (1920x1080x60p)
- HD-SDI (1900x1080x60i)
-
- The video processor shall have the capability of saving still images in a standard image file format such as TIFF or JPEG.
- The video processor shall have the capability of saving video clips in a standard video file format.
- The colonoscope shall satisfy the following requirements:
- The colonoscope shall be an FDA-cleared 510(k) colonoscope device.
- The direction of view shall be forward viewing.
- The field of view shall be 170 ° or wider.
- The depth of field shall cover the range of 5-100 mm or wider.
- The angulation (up/down/right/left) shall be 180°/180°/160°/160° or larger.
- The colonoscope shall have a water nozzle.
- The insertion tube diameter shall be 12.8 mm or smaller.
- The colonoscope shall have an instrument channel with diameter of 3.7 mm or larger.
- The medical display shall satisfy the following requirements:
- The signal input ports shall include:
- 12G-SDI
- 3G-SDI
- Display Port
- HDMI
- DVI
- The pixel count shall be equal to or greater than 3840x2160 pixels (4K).
- The display size (diagonal) shall be equal to or greater than 32 inches.
- The signal input ports shall include:
- All components in the system shall be powered by the standard 120 volts, 60 Hertz alternating current power in the U.S.
The Endoscope shall include a total system warranty for at least one (1) year, inclusive of any parts, labor, travel, and shipping cost to return the system to the original equipment manufacturer (OEM) standards.The Contractor shall deliver the endoscope within six (6) weeks of contract award. The Contractor shall provide a one (1)-year warranty period following system acceptance.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Health And Human Services → FDA Office Of Acq Grant Svcs
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS