Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

Energy Efficiency Phase 2 at various sites in San Bernardino County.

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California → San Bernardino County

NAICS

238220 - Plumbing, Heating, and Air-Conditioning ContractorsView NAICS

Place of Performance

CA

Set-Aside

NONE

Documents

(1)

Notice of Exemption - Energy Efficiency Phase 2 at Various Sites in San Bernardino County

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → San Bernardino County
Contacts1 person available
OfficeN/A
Organization / Agency
California → San Bernardino County
Office AddressN/A
Contacts
Sarah RileyChief of Project Management

Full Description

Show more
1. Bob Burke Government Center Project Description: Lighting upgrades Location: 63665 Palms Highway, Joshua Tree APN: 060413133 ATTACHMENT A Reasons why Exempt Consists of interior alterations to an existing facility, limited to replacement of existing light fixtures and related electrical components with high-efficiency LED fixtures. The work will occur entirely within the existing building, will not increase the building footprint, capacity, or intensity of use, and will result in equal or reduced electrical demand. The project qualifies for a Class 1 Categorical Exemption (Existing Facilities, 14 CCR Section 15301(a)). 2. Coroner Project Description: Lighting and mechanical upgrades, ground mounted solar system Location: 175 S. Lena Road, San Bernardino APN: 027926117 Reasons why Exempt: Includes interior and exterior energy-efficiency improvements at existing County facilities, including replacement of lighting and mechanical systems, and installation of a ground-mounted solar photovoltaic system. The lighting and mechanical work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures and equipment with no expansion of building footprint or intensity of use and is therefore exempt under the Class 1 Existing Facilities categorical exemption (14 CCR Section 15301 (a)&(d)) and the Class 2 (Replacement or Reconstruction) exemption 14 CCR Section 15302. The ground-mounted solar photovoltaic system involves minor alterations to land with limited grading and trenching, no removalof healthy, mature, or scenic trees, and no change in use or intensity, and is therefore exempt under the Class 4 Minor Alterations to Land categorical exemption (14 CCR Section 15304). N B 25 AR D C E O L 3. County Office Building C ER Project Description: Lighting and electrical upgrades 2 K Location: 412 W. Hospitality Lane, San Bernardino OF APN: 014137221 Reasons why Exempt: Consists of interior alterations to an existing facility, limited to replacement of existing light fixtures and related electrical components with high-efficiency LED fixtures. The work will occur entirely within the existing building, will not increase the building footprint, capacity, or intensity of use, and will result in equal or reduced electrical demand. The project therefore qualifies for a Class 1 Categorical Exemptio'ii (Existing Facilities, 14 CCR §15301(a)), and no exceptions apply. 4. County Office Building Project Description: Lighting, mechanical and control system upgrades, carport solar system Location: 8575 Haven Avenue, Rancho Cucamonga APN: 020949101 Reasons why Exempt Consists of interior and exterior energy-efficiency improvements to existing County facilities, including replacement of lighting, mechanical, and control systems, and installation of solar photovoltaic carport systems at existing parking lots. The lighting, mechanical, and controls work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures and mechanical equipment with no expansion of building footprint, capacity, or intensity of use, and is therefore exempt under the Class 1 Existing Facilities categorical exemption (14 CCR Section 15301(a)&(d)) and the Class 2 (Replacement or Reconstruction) exemption 14 CCR Section 15302. The solar carports and associated equipment at existing parking lots qualify for the statutory exemption under Public Resources Code section 21080.35. 5. Department of Public Health Project Description: Lighting, electrical, and mechanical upgrades Location: 451 E. Vanderbilt Way, San Bernardino APN: 028137205 Reasons why Exempt Consists of interior and exterior energy-efficiency improvements to existing County facilities, including replacement of lighting, mechanical, and electrical systems. The work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures, facilities, and mechanical equipment with no expansion of building footprint, capacity, or intensity of use. The Project is therefore exempt under the Class 1 (Existing Facilities) exemption 14 CCR Section 15301 (a)&(d) and the Class 2 (Replacement or Reconstruction) exemption 14 CCR Section 15302. 6. Hall of Records Project Description: Lighting and electrical upgrades, 5 EV chargers, rooftop and carport solar system Location: 222 W. Hospitality Lane, San Bernardino APN: 014136315 Reasons why Exempt: Consists of interior and exterior energy-efficiency improvements to existing County facilities, including replacement of lighting and electrical systems, and installation of rooftop solar photovoltaic on existing buildings and solar photovoltaic carport systems at existing parking lots. The work is limited to operation, repair, maintenance, and minor alteration of existing structures and mechanical equipment with no expansion of use, consistent with Class 1, Existing Facilities (14 CCR Section 15301) and Class 3, Small Structures, 14 CCR 15303 .. The rooftop solar photovoltaic, solar carports and associated equipment at existing parking lots qualify for the statutory exemption under Public Resources Code Section 21080.35. 7. High Desert Detention Center Project Description: Rooftop and carport solar system q Location: 9438 Commerce Way, Adelanto APN: 312926134, 312926133, 312926132, 312926156 Reasons why Exempt: Consists of installing solar photovoltaic systems on the roofs of existing buildings and on carport structures located within existing paved parking lots. The roofs and parking lots have been in continuous use for their current purposes for at least the previous two years, all associated equipment is located on re immediately adjacent to the buildings and parking areas, and no required or native trees will be removed. The Project therefore qualifies for the statutory exemption for solar energy systems under Public Resources Code Section 21080.35, and no exceptions to this exemption apply. 8. High Desert Government Center Project Description: Lighting and mechanical upgrades, 5 EV chargers, rooftop and carport solar system Location: 15900 Smoke Tree Street, Hesperia APN: 040722402 Reasons why Exempt: Consists of energy-efficiency and renewable energy improvements at existing County facilities, including interior and exterior lighting and mechanical system upgrades, installation of five electric vehicle (EV) charging stations, and installation of solar photovoltaic systems on the roofs of existing buildings and on carport structures within existing paved parking lots. All work is limited to the operation, repair, maintenance, replacement, and minor alteration of existing public facilities and mechanical equipment, with no expansion of building footprint, parking capacity, or intensity of use, and the Project is therefore exempt under the Class 1 Existing Facilities categorical exemption (14 CCR Section 15301(a)&(d)) and the Class 2 (Replacement or Reconstruction) exemption 14 CCR Section 15302; the rooftop and parking-lot solar facilities also qualify for the statutory exemption for solar energy systems under Public Resources Code Section 21080.35, and no exceptions to the use of these exemptions apply. 9. New Crime Lab Project Description: Lighting upgrades Location: 711 E. Rialto Avenue, San Bernardino APN: 027926121 Reasons why Exempt: Retrofit of existing lighting within the facility to more modern, energy efficient LED upgrades with no expanse to existing services. This would fall under Existing Facilities Section 15301 (a) exemptions. 10. Old Crime Lab Project Description: Lighting, mechanical and control system upgrades, rooftop and carport solar system Location: 200 S. Lena Road, San Bernardino APN: 027926121 Reasons why Exempt: Consists of interior and exterior energy-efficiency improvements to existing County facilities, including replacement of lighting, mechanical, and control systems, and installation of solar photovoltaic carport systems at existing parking lots and on rooftops at existing buildings. The lighting, mechanical, and controls work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures and mechanical equipment with no expansion of building footprint, capacity, or intensity of use, and is therefore exempt under the Class 1 Existing Facilities categorical exemption (CEQA Section 15301 (a)&( d)) and the Class 2 (Replacement or Reconstruction) exemption 14 CCR Section 15302. The rooftop solar, solar carports and associated equipment at existing parking lots/roofs qualify for the statutory exemption under Public Resources Code Section 21080.35 11. Sheriff Facility Project Description: Electrical System Upgrades Location: 1020 and 1060 Cooley Drive, Colton APN:027650143 25 Reasons why Exempt: Consists of interior energy-efficiency improvements to existing Counw facti1ties, including the replacement of lighting. The lighting is limited to operation, replacement and minor alteration of existing structures with no expansion of building footprint, capacity, or intensity of use, and is therefore e>relnpt under Class 1 Existing Facilities categorical exemptions (15 CCR Section 15301(a)). 12. Sheriff Headquarters Project Description: Lighting, mechanical, control system and electrical upgrades Location: 655 E. Third Street, San Bernardino APN: 013532113 !?i Sc - Reasons why Exempt: Consists of interior and exterior energy-efficiency improvements to existing County facilities, including replacement of lighting, mechanical, and control systems, and electrical upgrades. The work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures, facilities, and mechanical equipment with no expansion of building footprint, capacity, or intensity of use. The Project is therefore exempt under the Class 1 (Existing Facilities) exemption 14 CCR Section 15301(a)&(d) and the Class 2 (Replacement or Reconstruction) exemption 14 CCR Section 15302. 13. Sheriff's Training Center Project Description: Lighting, mechanical and control systems upgrades, rooftop and carport solar system Location: 18900 Institution Road, Devore APN: 026203115 Reasons why Exempt: Consists of interior and exterior energy-efficiency improvements to existing County facilities, including replacement of lighting, mechanical, and control systems, and installation of solar photovoltaic carport systems at existing parking lots and on existing rooftops. The lighting, mechanical, and controls work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures and mechanical equipment with no expansion of building footprint, capacity, or intensity of use, and is therefore exempt under the Class 1 Existing Facilities categorical exemption (15 CCR Section 15301(a)&(d)) and the Class 2 (Replacement or,Reconstruction) exemption 14 CCR Section 15302. The solar carports, rooftop solar and associated equipment at existing parking lots/roofs qualify for the statutory exemption under Public Resources Code Section 21080.35. 14. West Valley Adult Detention Center Project Description: Lighting upgrades, rooftop, carport and ground mounted solar system Location: 9500 Etiwanda, Rancho Cucamonga APN: 022928396 Reasons why Exempt: Consists of interior and exterior energy-efficiency improvements at existing County facilities, including replacement of lighting I systems, installation of a rooftop and ground-mounted solar photovoltaic system, and solar carport systems at existing parking lots. The lighting work is limited to operation, repair, maintenance, replacement, and minor alteration of existing structures and equipment with no expansion of building footprint or intensity of use, and is therefore exempt under the Class 1 Existing Facilities categorical exemption (Section 15301 (a)). The ground-mounted solar photovoltaic system involves minor alterations to land with limited grading and trenching, no removal of healthy, mature, or scenic trees, and no change in use or intensity, and is therefore exempt under the Class 4 Minor Alterations to Land categorical exemption (14 CCR Section 15304). The rooftop and solar carports and associated equipment at existing parking lots/rooftops qualify for the statutory exemption under Public Resources Code Section 21080.35.

Similar Contracts

Same NAICS industry code

NAICS: 238220
New
SLED
PIDC Project 3 - Dorm RTU Replacement and SCADA
Solicitation # 70CMSW26D00000004
Solicitation 70CMSW26D00000004 is a firm-fixed-price construction task order issued by U.S. Immigration and Customs Enforcement (ICE) for the Port Isabel Detention Center in Los Fresnos, Texas. The project focuses on replacing and upgrading obsolete, corroded rooftop HVAC units (RTUs) for the Alpha, Bravo, Charlie, and Delta dorms, as well as upgrading the SCADA software and installing two chemical feed pumps. The objective is to implement high-quality, energy-efficient, and coastal weather-resistant systems that exceed commercial standards and comply with Texas Commission of Environmental Quality (TCEQ) regulations. The estimated magnitude of the project is between 1.2 million and 1.5 million dollars, with a period of performance of 365 days from the date of award. This is an 8(a) set-aside solicitation under NAICS code 238220. Award will be based solely on the lowest total evaluated price, provided the offeror meets technical requirements, including a sound technical approach and a comprehensive quality control and safety plan. Key requirements include a one-year contractor warranty for installation and craftsmanship, manufacturer certification for all installers, and strict adherence to facility security protocols, including E-Verify and criminal background checks for all personnel. The contractor must provide a Project Manager with at least five years of federal contracting experience. Payment will be processed electronically via the Invoice Processing Platform (IPP) and must be accompanied by certified payroll in accordance with Davis-Bacon wage determinations for Cameron County, Texas.
Bristol Alliance of Companies

POSTED

about 14 hours ago

DEADLINE

in 2 days
View Details
NAICS: 238220
New
Joliet JCC Dorm Bathroom Renovations
Solicitation # joliet-jcc-dorm-bathroom-renovations
Management and Training Corporation (MTC) has issued a subcontracting solicitation for the renovation of thirty-two female dorm bathrooms at the Joliet Job Corps Center in Joliet, Illinois. This fixed-price, lump-sum opportunity, categorized under NAICS 238220, has an estimated value between $100,000 and $250,000 and is set aside for small businesses. The scope of work includes clearing sanitary drain lines for 64 vanity drains, 32 toilets, and 32 shower drains, as well as replacing shower units, faucets, and toilets with specific approved models or comparable equivalents. Bidders are required to perform a physical site visit and sign an attendance roster prior to submitting their proposals. Proposals must be submitted via email by September 23, 2026, at 3:00 PM CT. Submissions must include a detailed cost breakout on company letterhead covering materials, labor, equipment, fees, bonds, and overhead, along with manufacturer cut sheets and warranty information. For bids of $25,000 or more, a bid bond guarantee of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A- rating. Compliance with prevailing wage rates via weekly certified payroll reports is mandatory. Additionally, contractors must adhere to strict security protocols, including individual sign-in/sign-out procedures, and must comply with federal regulations regarding privacy breach notifications and records management. Award decisions will be based on the overall best value.
Joliet Job Corps

POSTED

about 14 hours ago

DEADLINE

in about 6 hours
View Details
NAICS: 238220
New
CBP7664 Wellness HVAC Compressor Replacement
Solicitation # CBP7664
Management & Training Corporation (MTC) is seeking bids for a subcontracting opportunity to replace a failed HVAC/refrigeration compressor at the Wellness facility of the Sierra Nevada Job Corps Center in Reno, Nevada. The project requires the contractor to provide all labor, materials, equipment, and supervision to execute a four-phase process: preparation and environmental safety, demolition and removal, installation of an OEM-specified compressor, and final system testing and commissioning. All work must be completed within 30 consecutive business days following a written Notice to Proceed. Bids will be evaluated based on overall best value, considering price, quality, and delivery schedule. The solicitation is open to various small business categories, including SDB, WOSB, HUBZone, VOSB, and SDVOSB, under NAICS code 238220. Bidders must provide a lump sum bid and a detailed bid breakout. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety company. Compliance with the Davis-Bacon Act and Executive Orders 14026 and 13658 regarding prevailing wage rates for Washoe County is mandatory. Additionally, contractors must adhere to EPA Section 608 regulations for refrigerant recovery and submit a completed SF 1413 and first-tier subcontractor information if the award exceeds 40,000 dollars. A physical site visit and signature on the attendance roster are required prior to bid submission.
Sierra Nevada Job Corps Center

POSTED

about 14 hours ago

DEADLINE

in 1 day
View Details
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) 1091 – Glazing/Welding/Heavy Mechanics Bldg
Solicitation # 26-140
Adams & Associates, Inc. is soliciting a single lump sum contract to replace a failing 10-ton gas-fired packaged HVAC unit at the Atterbury Job Corps Center in Edinburgh, Indiana, specifically within Building 1091. The project requires the installation of a new 12.5 SEER packaged unit utilizing non-R22 refrigerants, such as R-410A or R-454B, while reusing existing ductwork, electrical disconnects, and thermostat wiring. The contractor must leave the old unit at the maintenance building for parts and provide labeled recovered refrigerant to the facility. Work must commence within 14 days of the Notice to Proceed, and a sequenced construction schedule is due within 10 days of that notice. Award will be based on best value, evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Mandatory requirements for bidders include attendance at the site visit on September 23, 2026, a valid Indiana Contractor's License, and active registration in SAM.gov with a Unique Entity ID. Proposals must be submitted by October 5, 2026, and include a detailed cost breakdown, a 90-day bid guarantee, and proof of specific automobile and workers' compensation insurance. The contract mandates compliance with EPA, OSHA, and Davis-Bacon Act wage determinations, and includes a one-year workmanship guarantee. Final payment is contingent upon the submission of certified payroll records, release of liens, and a completed SF 1413.
Adams & Associates, Inc.

POSTED

about 14 hours ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) ABL Dormitory
Solicitation # 26-141
Adams & Associates, Inc. is soliciting a single lump sum subcontract for the replacement of HVAC systems at the Atterbury Job Corps Center ABL Dormitory in Edinburgh, Indiana. The project requires replacing eight vertical up-flow gas-fired furnaces with DX-coils and matched air-cooled condensing units. The new installations must be 12.5 SEER packaged units utilizing non-R22 refrigerants, such as R-410A or R-454B, while reusing existing ductwork, thermostat wiring, and electrical disconnects. All recovered refrigerant must be labeled and left on-site. The contractor is responsible for all material storage and must adhere to EPA, OSHA, and Indiana state and local building codes. Eligible bidders must be registered in SAM.gov with a valid Unique Entity ID and provide a valid Indiana Contractor's License, W9, and specific insurance certificates naming Adams and Associates, Inc. as an additional insured. Proposals are due by October 5, 2026, and must include a detailed cost breakdown, a timeline for substantial completion, and a 90-day bid guarantee. Award will be based on best value, evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). The contract includes a one-year workmanship guarantee and requires compliance with Davis Bacon Act wage determinations. Payment terms are Net 30, contingent upon the submission of certified payroll and lien releases.
Adams & Associates, Inc.

POSTED

about 14 hours ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) ABL Dormitory
Solicitation # 26-141
Adams and Associates, Inc., operating for the U.S. Department of Labor, is soliciting a single lump sum contract to replace HVAC systems at the Atterbury Job Corps Center ABL Dormitory in Edinburgh, Indiana. The project involves replacing existing R-22 Bryant air cooled condensing units, including an 8.5-ton unit for common areas and various 3.5 to 4-ton units for dormitory wings A, B, C, and D, with new 12.5 SEER packaged units utilizing non-R22 refrigerants such as R-410A or R-454B. The contractor is required to reuse existing electrical disconnects, ductwork, and thermostat wiring, and must label and leave all recovered refrigerant on-site. The award will be based on best value, evaluating price, quality, past performance, and schedule. Mandatory requirements for bidders include attending a site visit on September 23, 2026, maintaining an active SAM.gov registration with a Unique Entity ID, and providing a valid Indiana Contractor's License. Proposals must be submitted by October 5, 2026, and include a detailed cost breakdown, W9, and certification of compliance with Davis Bacon Act wage rates. Performance must begin within 14 days of the Notice to Proceed, with a sequenced construction schedule due within 10 days. Final payment is subject to net 30 terms and is contingent upon the submission of certified payroll, a completed SF 1413, and the release of all subcontractor liens.
Adams & Associates, Inc.

POSTED

about 14 hours ago

DEADLINE

in 12 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS