Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of The Treasury was posted on April 17, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fire Control System Replacement in NOC

Awarded
20341225Q00024Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and materials to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The contractor must verify proper clutch engagement and test the PTO system under load to ensure the unit is restored to safe and reliable operating condition according to manufacturer specifications. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified firms. Bidders must submit a written proposal by November 3, 2026, including a bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Proposals must provide an itemized breakdown of costs, warranty information, and a detailed description of the proposed services. Award will be based on best value, and the contractor must comply with various federal regulations, including Service Contract Labor Standards under Wage Determination 2015-4687 Revision 31 and FAR clauses regarding small business utilization and combating trafficking in persons. Final acceptance is contingent upon inspection by the Facility Maintenance Department.
Earle C. Clements Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in 6 days
NAICS: 811310
New
SLED
IFB 26C091005 - Hangar Door Hydraulic System Upgrade Services - CHP Academy Special Weapons and Tactics (SWAT)
Solicitation # 26C091005
The Department of the California Highway Patrol (CHP) is soliciting bids for Invitation for Bids (IFB) 26C091005 to perform a complete hydraulic system upgrade for two hangar doors at the CHP Academy SWAT facility in West Sacramento, California. The scope of work requires the contractor to provide all labor, materials, and equipment, including the installation of hydraulic power units, heavy-duty cylinders, rebuild kits, high-pressure hoses, and climate-appropriate fluid. The anticipated period of performance is from January 1, 2027, to June 30, 2027. A mandatory site walk-through was scheduled for November 9, 2026, and the final response deadline is November 23, 2026. The contract will be awarded to the lowest responsive and responsible bidder. A critical requirement is a minimum of 5% Disabled Veteran Business Enterprise (DVBE) participation, though incentives are available for higher participation levels. Bidders must comply with California prevailing wage laws, the Americans with Disabilities Act, and various safety and building codes. Depending on the final contract value, performance and payment bonds may be required for amounts exceeding 10,000 and 25,000 dollars, respectively. Submission requires a physical bid package containing specific certifications, including the Bidder Declaration, Non-Collusion Affidavit, and California Civil Rights Certification.
Department of the California Highway Patrol

POSTED

about 5 hours ago

DEADLINE

in 26 days

AI Contract Overview

Show more

Fiscal Service, on behalf of the Financial Crimes Enforcement Network, is soliciting quotes for the replacement of the fire control system in the Network Operations Center located in Vienna, Virginia. This 100% small business set-aside project involves replacing a 20-year-old Simplex Grinnell system and upgrading smaller FCI systems to addressable FCI S-3 systems. The scope of work includes equipment installation, programming, testing, and a one-year warranty, followed by a three-year preventive maintenance agreement. A critical requirement is a response time of no more than four hours for emergency repairs to support the emergency fire watch for the NOC and building fire alarm system. The contract structure consists of a base year from April 16, 2025, to April 15, 2026, with three subsequent one-year option periods. Award will be granted to the lowest price technically acceptable offeror. Key technical details specify that the system includes underfloor and ceiling smoke detection, is connected to a pre-action sprinkler system, and requires technicians to be US citizens. While the primary NAICS code is 811310, the government will consider proposals under NAICS 238210. Following amendments, the final deadline for the submission of offers is Tuesday, April 22, 2025, at 2:00 pm EST.

General Info

Contract Value

$2,000

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Vienna, VA, 22182, USA

Set-Aside

SBA

Awardee

DAJANI LLC

Award Issued Date

Documents

3

20341225Q00024 Fire Control System Replacement in NOC

PDF, High priority: read this first39 pages · rfq
High

Attachment A - Products and Pricing List (20341225Q00024)

XLSX, High priority: read this first1 page · rfq
High

SOW Fire Alarm System NOC (RFQ 20341225Q00024/Amendment 2)

PDF, High priority: read this firstsow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseAwarded
Posted

Combined Synopsis

Notice updated

Response deadline changed from Apr 1, 2025 to Apr 4, 2025. The notice description changed.

Notice updated

Response deadline changed from Apr 4, 2025 to Apr 22, 2025. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of The Treasury → Arc Division Proc Svcs - Fincen
Contacts2 people available
OfficePARKERSBURG, WV, 26101, USA
Office AddressPARKERSBURG, WV, 26101, USA

Full Description

Show more
The purposes of this amendment 2 for RFQ 20341225Q00024 are as follows: 1) Add the following to page 2 in the Statement of Work (SOW): - A response time of no more than 4 hours for Emergency repairs due to the emergency fire watch for the NOC and the building fire alarm system. A revised SOW is attached to this SAM.gov RFQ posting. 2) Re-open the solicitation to accept offers until Tuesday, April 22, 2025, at 2:00 pm EST. _________________________________________ The purpose of this amendment #1 for RFQ 20341225Q00024 is as follows: 1) Provide answers to the following questions that were posed by prospective vendors 2) To extend the offer due date from Tuesday, April 1, 2025 at 2:00 pm EST, to Friday, April 4, 2025, at 2:00 pm EST. Questions & Answers: 1. There is not a requirement for the Fire Alarm Plans to be designed, reviewed, and approved by a minimum NICET IV Fire Detection Engineering Technician prior to submission to FinCEN. Please confirm if a NICET IV will be added as a requirement to ensure code compliance. Answer: No 2. Additional information is required in order to design a complete replacement fire alarm system that is in accordance with the statement of objectives and all applicable codes, industry standards, and regulations. a) Please provide as-built drawings of the existing fire alarm system/building layout. Answer: Unavailable. The system is 20 years old. b) If you can, please provide device counts Answer: 2 Graphic Annunciator Panels, 35 Addressable smoke detectors, 5 Addressable relay modules 3. There is not a requirement for the Fire Alarm system cabling installation, termination, and testing to be overseen by an RCDD (Registered Communications Distribution Designer) prior to submission to the Contracting Officer. An RCDD ensures compliance with codes and industry standards and optimizes system performance of cabling and communications systems. a) Please confirm if an RCDD will be added as a requirement to ensure standards, compliance, and allow a detailed review by the ISO (Information Security Officer) prior to deployment and installation. Answer: No 4. In the Statement of Work under Preventative Maintenance, fire extinguisher inspections are requested. Please confirm if these are part of solicitation and if so, please provide the type of extinguishers required for inspection, the quantities per type, when inspections are to be completed, and an updated price/cost schedule with this line item included. Answer: The Fire Extinguishers will be dealt with at a later date. 5. Would the government consider updating the NAICS Code from 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance to 238210 Electrical Contractors and Other Wiring Installation Contractors? We believe that 238210 better aligns with the scope of services per census.gov for - Fire Alarm Install. https://www.census.gov/naics/?input=23&chart=2022&details=238210 Answer: Will consider contractor proposed NAICS Code including 238210. 6. In the Statement of Work under Preventative Maintenance, Emergency Repairs are requested. Please clarify how this is to be priced. Typically for emergency repairs we provide our hourly rate, and the government assigns either a fixed number of hours, or a fixed NTE dollar amount. Answer: Provide fixed hourly rate, response time for emergency repairs. 7. Will the new Computer Room Panel be networked with the Base Building Panel? If so, how far is the existing panel? Answer: Yes, the main building panel is on the Ground Level in the Fire Control Room. 8. Is the Computer Room panel connected to a Pre Action System or a Clean Agent System? Answer: The system is a pre-action system 9. Does the Computer Room have a Vesda Detector? Answer: No 10. Does the new system have underfloor Smoke Detection? Answer: Yes, below the ceiling and under the floor. 11. Does the new system need Manual Pull-stations? Answer: The system has 2 abort buttons and 2 Power Off Buttons. No manual pull stations. 12. Is the Sprinkler System being monitored by this new Fire Alarm Panel? If so, how many Tamper and Flow switches, and other monitored equipment? Answer: Yes 13. Can work be done during the day or night? Answer: Day 14. Is existing System and branch circuits installed in Conduit? Answer: Yes 15. Is the existing Simplex Panel recessed in the wall or is it surface mounted? Answer: Both are surface mounted 16. What are the building Construction Requirements? a) Do the building requirements restrict noise during certain hours? Answer: Yes, Between 8:00 am and 5:00pm. 17. Are the Panels located in the Computer Rooms or a separate closet Answer: In the computer room 18. What are the sizes of the 3 Annunciators? Answer: Small is approximately 18'X18'X4 2 larger are 36'X24'X6. The panels showing the devise locations are 11'X9'X4 19. What type of ceiling is in the computer rooms. Answer: Suspended ceiling with 2 Hour fire rated ceiling tiles. 20. What type of notification devices are in the computer room? How many? Answer: SIMPLEX 4100/4020 FIRE ALARM, Main Fire Alarm Panel, Fire Alarm Battery (Each), Digital Alarm Communicator Transmitter (DACT) Annuciator, Smoke Detector Conventional 21. What is the Model number of the Base Building Fire Alarm System? Answer: Unknown 22. Are Technicians required to be US Citizens? Answer: Yes 23. Is it possible to schedule a site walk? Who would coordinate this? Answer: No site visit planned at this time. 24. Who can be contacted at the facility to schedule a site visit? Answer: No site visit planned at this time. 25. Also, do you have drawing plans for the system that will be upgraded? Answer: No 26. Is this a brand-new contract? Answer: Yes, except for the conduit, wiring for the smoke heads will remain and new smoke heads replace existing. a) If not a brand-new contract, who was the incumbent performing these services? Answer: Johnson Controls b) If not a brand-new contract, could you please provide the current / previous contract number? Answer: No ________________________________________________________________________ Fiscal Service Procurement on behalf of the Financial Crimes Enforcement Network (FinCEN) has a Request for Quote (RFQ) for the purchase of Fire Control System Replacement in NOC in accordance with the attached Statement of Work (SOW). Period of Performance: Base Year: 04/16/2025 - 04/15/2026 Option Year 1: 04/16/2026 - 04/15/2027 Option Year 2: 04/16/2027 - 04/15/2028 Option Year 3: 04/16/2028 - 04/15/2029 REFER TO ATTACHMENT A for a list of products and pricing This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a SAM.Gov 100% Small Business set aside under NAICS 811310. Award will be made to the offeror with the lowest price technically acceptable quote. Technical acceptability will be determined by comparing quotations and technical criteria with the requirements of this solicitation in accordance with the SOW. An all-inclusive fixed price award (to include installation and delivery cost) will be made to the contractor whose quote represents the lowest price, technically acceptable offer. The Government intends to make one award from responses received. Submit your questions and quotes to Attn: 20341225Q00024 Fire Control System Replacement in NOC - JRS/MH to contact@example.gov. Questions will be due no later than 03/26/25 @ 2:00 PM ET. Proposal will be due no later than 04/01/25 @ 2:00 PM ET. Delivery Location: 2070 Chain Bridge Rd, Suite G-99 Vienna, VA 22182

More opportunities from Department Of The Treasury → Arc Division Proc Svcs - Fincen

Same awarding agency

NAICS: 541611
Federal
Federal Financial Policy & Process Advisory ServicesThe contract requires advisory services to ensure DPAS operations are fully aligned with federal financial management policies, specifically adhering to standards established by the Office of Management and Budget and the Department of the Treasury. The work involves evaluating current processes, identifying gaps in compliance, and recommending actionable strategies to enhance efficiency, accountability, and regulatory adherence across financial operations. The contractor will be expected to provide expert guidance on modernizing workflows and implementing improvements that support consistent application of federal financial controls. Performance of this subcontract is localized to the 78701 ZIP code area, with execution under the oversight of the Arc Division Proc Svcs - Fincen within the Department of the Treasury. The NAICS code 541611 indicates the nature of the services as management consulting, emphasizing strategic process optimization rather than direct financial execution. The contract was posted in April 2026 and is structured as a subcontract, suggesting it supports a larger federal financial management initiative. There is no designated set-aside classification, and all efforts must center on achieving full compliance with federal financial governance frameworks while delivering measurable process enhancements.
Administrative Management and General Management Consulting Services

POSTED

6 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS