Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on July 19, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fire Supression Repair

Awarded
FA441717R0006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The project requires the contractor to bypass internal lock mechanisms and install Grade I panic bars, exterior trim, rim cylinders, strikes, and door closers at five specific locations: the B-Cafeteria, CM-Men's Dorm, CW-Women's Dorm, D-Recreation, and F-Vocational. All work must comply with NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and the Americans with Disabilities Act. Performance requirements include a site survey to verify door dimensions and fire ratings, followed by a minimum of 10 consecutive cycle tests to ensure fail-safe operation. This is a fee-for-service subcontracting opportunity set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bidders must submit a lump sum price and individual pricing per deficiency by December 1, 2026. Required submission documents include a bid sheet, a completed supplier packet with a W-9 and self-certification form, and three references for projects of similar scope. The contract is subject to various federal regulations, including FAR 52.222-4 for work hours and safety, and prevailing wage rates for building construction in Canyon and Gem Counties, Idaho, as specified in General Decision Number ID20250106. Final acceptance is contingent upon inspection by MTC at the designated point of delivery.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
Pauma Security Gate
Solicitation # 2026-27-06
Solicitation 2026-27-06 for the Valley Center Pauma Unified School District involves the fabrication and installation of automated, keypad-entry hinging steel security swing gates at entry and egress driveways in Valley Center, California. The project requires two powder-coated steel double swing gates, each 18 feet wide by 5 feet tall, and explicitly prohibits the use of chain link options. Key technical components include a mounted Knox switch with Fire Department filing, two entry remotes, gate hold timers, a mounted strobe detector for emergency vehicles, and a keypad similar to the Door King 1506-086. The contract value is capped at 1,000,000 dollars, and the award will be granted to the lowest responsive and responsible bidder. Eligible bidders must hold a California contractor's license C13 or C-61/D28 and comply with prevailing wage requirements and Department of Industrial Relations registration. The project mandates a payment bond for 100 percent of the total bid price and a DVBE participation goal of at least 3 percent. Required submissions include a comprehensive bid packet featuring non-collusion affidavits, Iran Contracting Act certification, and fingerprinting certifications. Performance must be coordinated with the Director of Maintenance and Operations, with work hours restricted to 7:00 am to 5:00 pm, Monday through Friday. Additionally, contractors must adhere to strict hazardous material standards and California Air Resources Board compliance, with the district maintaining the right to terminate the agreement upon 30 calendar days written notice.
Valley Center Pauma USD

POSTED

about 20 hours ago

DEADLINE

in 5 days
NAICS: 238290
New
SLED
Districtwide Elevator And Wheelchair Lift Service, Preventive Maintenance, And Repairs Maintenance Services
Solicitation # 27.004
The Hayward Unified School District is soliciting bids under solicitation number 27.004 for districtwide elevator and wheelchair lift service, preventive maintenance, and repairs. The selected contractor will be responsible for the systematic examination, maintenance, and repair of all owned or leased systems, including hydraulic, electrical, and mechanical components, to ensure they remain in safe and usable condition. This contract requires the provider to hold an active C-11 Elevator Contractor license from the State of California and comply with all local and state codes, including Title 24 of the California Code of Regulations. The award will be granted to the lowest responsive and responsible bidder based on the rates provided in the bid form. Performance of regular services typically occurs Monday through Friday during standard business hours, while emergency repairs must be available 24 hours a day, seven days a week. The contractor must provide a bid bond of at least 10 percent of the bid amount and subsequently provide payment and performance bonds upon award. Invoicing is conducted monthly, with a requirement that authorized materials be invoiced at no more than 15 percent above the vendor's cost. Key compliance requirements include paying prevailing wages per the California Labor Code, submitting to fingerprinting and felony conviction certifications, and maintaining a minimum one-year warranty on work. All contracts are governed by the laws of the State of California.
Hayward Unified School District

POSTED

about 21 hours ago

DEADLINE

in 19 days

AI Contract Overview

Show more

Solicitation FA441717R0006, issued by the Department of Defense for Hurlburt Field, Florida, is a HUBZone Small Business set-aside project to upgrade the fire suppression system in Hangar 90032. The scope of work includes relocating a foam concentrate tank from Building 90036 to Hangar 90032, filling it with new concentrate, and modifying associated stainless and carbon steel piping to the foam risers. The contractor is required to perform a complete system test to ensure modifications meet specifications. Technical requirements involve the installation of flame detectors, wet pipe high-expansion foam systems, and compliance with NFPA, UFC, and ETL standards. Additional facility modifications include moving a 400 Hertz generator from Hangar 90032 to Building 90036, performing necessary electrical upgrades for its operation, and installing an intake louver, wall prop fan, and unit heater in the generator's new location. The project also requires adding a ductless mini-split air conditioner to Electrical Room 113 in Hangar 90032 and modifying fire pump test header piping in Building 90036. This negotiated RFP requires performance and payment bonds, with a performance period of 240 calendar days.

General Info

Contract Value

$717,951

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

Hurlburt Field, HURLBURT FIELD, FL, 32544, USA

Set-Aside

NONE

Award Issued Date

Documents

15

15107FP-3-Layout1 - Foam Piping Layout

PDF, High priority: read this firstspecifications
High

15107FP-5-Layout1 - Flame Detector Installation Layout

PDF, High priority: read this firstspecifications
High

15107FP-7-Layout1 - Fire Suppression System Layout

PDF, High priority: read this firstspecifications
High

Amendment 0001 - FA441717R0006

PDF, High priority: read this firstamendment
High

Amendment 0002 - Project FTEV 15-1016

PDF, High priority: read this firstamendment
High

Amendment 0003 - FA441717R006

PDF, High priority: read this firstamendment
High

Amendment 0004 to Solicitation FA441717R006

PDF, High priority: read this firstamendment
High

New Work Plans - Request No. PF-4

PDF, High priority: read this firstspecifications
High

Project FTEV_15–1016 Layout 1 - Personnel Engineering Inc.

PDF, High priority: read this firstspecifications
High

Repair Fire Suppression Bldg 90032 - RFP Addendum #1

PDF, High priority: read this firstamendment
High

Section 21 13 39: Low-Level High Expansion Foam Fire Extinguishing Systems for Aircraft Hangars

PDF, High priority: read this firstspecifications
High

Solicitation FA441717R0006 - Repair Fire Suppression Bldg 90032

PDF, High priority: read this firstrfp
High

FA4417-17-R-0006 Questions and Answers

PDF, Low priorityq-and-a
Low

Site Visit Memo - FA4417-17-R-0006 Repair/Replace Fire Suppression

PDF, Low priorityspecial-notice
Low

Synopsis: Repair Fire Suppression System, Hangar 90032, Hurlburt Field

PDF, Low prioritypresolicitation
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

11 updates
PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Sources Sought

Notice updated

The notice description changed.

Type Changed

Sources Sought → Presolicitation

Notice updated

The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Deadline changed

Response deadline changed from Apr 17, 2017 to Apr 25, 2017.

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Response deadline time changed from 10:00 PM UTC to 8:00 PM UTC on Apr 25, 2017. The notice description changed.

Notice updated

Response deadline changed from Apr 25, 2017 to May 2, 2017. The notice description changed.

Notice updated

Response deadline changed from May 2, 2017 to May 9, 2017. The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4417 1 Socons
Contacts2 people available
OfficeHURLBURT FIELD, FL, 32544-5810, USA
Office AddressHURLBURT FIELD, FL, 32544-5810, USA
Contacts

Full Description

Show more
This project is being solicited under AFFARS MP5332.7. Notice to Offeror(s)/Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs. This synopsis is for the Upgrade Hangar Fire Suppression System project in Hangar 90032 located on Hurlburt Field, FL. The contractor shall furnish all labor, materials, tools, supervision, and equipment to perform all operations necessary to accomplish all work as shown on project drawings and specifications: FTEV 15-1016, to repair the fire suppression system at Hangar 90032. Remove an existing foam concentrate tank from Bldg 90036, transport it across the street, and then install it in Hangar 90032. Fill the tank with new foam concentrate. Install/Modify the associated stainless steel and carbon steel piping from the new tank location to the foam risers. Perform a complete foam system test at the hangar to demonstrate that the modifications are acceptable. Move a 400 Hertz generator out of the Electrical room 113 in Hangar 90032 and move it to Bldg 90036. Make all electrical upgrades required to make the generator operational in its new location. Add a ductless mini-split air conditioner to the Electrical room 113 in Hangar 90032. Add an intake louver, wall prop fan and unit heater to the utility room in Bldg 90036 that will house the 400 Hz generator. Modify the fire pump test header piping in Bldg 90036 to route the pipe above the door. This acquisition will be set aside for HUB Zone Small Business offerors only. The North American Industry Classification System (NAICS) code for this project is 238290 with a size standard of $15M. This contract will be awarded in accordance with FAR Part 15, Negotiated Procedures. The Government reserves the right to award a contract to other than the low proposed price. Performance period is 90 calendar days. The contract will be a single award, Firm-Fixed-Price type contract. Estimated magnitude for the total project is between $250,000 and $500,000. Bid bonds will be required with the proposal. Payment and performance bonds will be required within ten (10) days of contract award. The work is required in support of the 1st Special Operations Civil Engineer Squadron. The issuance date for this solicitation is projected to be on/about 15 Jan 2017. Prospective contractors must be registered in the System for Award Management (SAM) Database prior to award of a government contract. Offerors are further advised that failure to register in the SAM Database will render your firm ineligible for award. Registration requires applicants to have a DUNS number. Recommend registering immediately in order to be eligible for timely award. This solicitation will be available ONLY via the Internet at the following address: http://www.fbo.gov. For information on how to register your company on FBO, to view or receive updates and notifications to the solicitation, please reference the FBO Vendor Guide located on the FBO web site home page. NO paper copies of the solicitation will be furnished and electronic submission of proposals will be used for this requirement. Upgrade Hangar Fire Suppression System project in Hangar 90032 located on Hurlburt Field, FL. The contractor shall furnish all labor, materials, tools, supervision, and equipment to perform all operations necessary to accomplish all work as shown on project drawings and specifications: FTEV 15-1016, to repair the fire suppression system at Hangar 90032. Remove an existing foam concentrate tank from Bldg 90036, transport it across the street, and then install it in Hangar 90032. Fill the tank with new foam concentrate. Install/Modify the associated stainless steel and carbon steel piping from the new tank location to the foam risers. Perform a complete foam system test at the hangar to demonstrate that the modifications are acceptable. Move a 400 Hertz generator out of the Electrical room 113 in Hangar 90032 and move it to Bldg 90036. Make all electrical upgrades required to make the generator operational in its new location. Add a ductless mini-split air conditioner to the Electrical room 113 in Hangar 90032. Add an intake louver, wall prop fan and unit heater to the utility room in Bldg 90036 that will house the 400 Hz generator. Modify the fire pump test header piping in Bldg 90036 to route the pipe above the door.

More opportunities from Department Of Defense → FA4417 1 Socons

Same awarding agency

NAICS: 238210
Federal
Utility Disconnection and CappingThe contract requires the safe disconnection and capping of all utility lines—including electrical, water, gas, and sewer—that serve the building prior to its demolition. This work must be performed in strict compliance with safety standards to prevent hazards during and after the disconnection process, ensuring no residual pressure, power, or flow remains in any system. All procedures must follow industry best practices and regulatory requirements to protect workers, the environment, and surrounding infrastructure. The work is classified under NAICS code 238210, which pertains to plumbing, heating, and air-conditioning contractors, indicating the specialized nature of the tasks involved. This is a total small business set-aside subcontract, meaning only entities certified as small businesses under the SBA’s guidelines are eligible to bid. The contract was posted on May 5, 2026, and the place of performance is located in the zip code 32544 under the oversight of the Department of Defense, specifically the FA4417 1 Socons office. The nature of the work requires precision and expertise in utility system shutdown protocols, and all activities must be completed within a timeframe that aligns with the broader demolition schedule. Though no point of contact is listed, potential bidders can access further details through the provided SAM.gov link.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

6 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS