H312--Fire Alarm and Testing Inspection FY 2027 Services Procurement - 541 Engineering - VAMC CLEVELAND

Active
36C25027Q0066Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs is conducting market research through a Sources Sought notice to determine an acquisition strategy for fire alarm testing and inspection services at the Louis Stokes VA Medical Center in Cleveland, Ohio. The objective is to secure a qualified contractor to provide all labor, materials, equipment, and supervision for the preventative maintenance, inspection, and testing of government-owned Notifier fire alarm and fire suppression components. The scope includes annual, semi-annual, and quarterly testing, as well as specialized inspections for elevator devices and kitchen hoods, all of which must comply with NFPA 72 (2022 edition), NFPA 25, OSHA, TJC, and original equipment manufacturer standards. The anticipated contract will be a firm-fixed-price service agreement consisting of a one-year base period with four option years. To be considered capable, contractors must demonstrate a minimum of five years of experience within the last seven years maintaining Notifier systems of similar size and complexity. Requirements include proof of Notifier Dealer status, programming capabilities, and access to parts and technical support. The contractor will be responsible for providing a site-specific safety plan and detailed electronic reports in Excel and PDF formats. This notice is for informational purposes only and is not a solicitation; the government is not seeking pricing or offers at this time. Interested sources must submit their capabilities and references via email to the designated contract specialist by October 30, 2026. The procurement falls under NAICS code 56121 with a small business size standard of 25 million dollars.

General Info

Market research for fire alarm testing and inspection services at Cleveland VA Medical Center.

NAICS

561621 - Security Systems Services (except Locksmiths)

Place of Performance

Department of Veteran Affairs Cleveland VA Medical Center, Cleveland, OH, 44106, USA

Set-Aside

NONE

Documents

1

Sources Sought: Fire Alarm and Testing Inspection FY 2027 - VAMC Cleveland

DOCX, High priority: read this first12 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
Contacts
Lakeisha JacksonContract Specialist

Full Description

Show more
This is a Sources Sought (SS) Notice only, not a solicitation announcement and should not be considered as such. There is no solicitation available at this time. The Government will not pay for any information received in response to this SS, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This SS does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purposes only and will not be released. Vendor participation is not a promise of future business with the Government. The purpose of this Sources Sought is to conduct Market Research to determine an acquisition strategy for the acquisition of Fire Alarm Testing and Inspection, where the Contractor will provide on-site testing and inspection of government-owned Notifier fire alarm and fire suppression components required by NFPA, OSHA, TJC, and original equipment manufacturer standards and specifications necessary to maintain the current fire alarm system at top performance. The NAICS code for this procurement is 56121 - Security system services except locksmiths, PSC H312 Inspection fire control equipment. and the small business size standard is $25,000,000.00.
Responses to this notice shall be e-mailed to Lakeisha Jackson at Lakeisha.Jackson@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than Friday, October 30, 2026 at 12:00 p.m., EDT. This notice is to assist the VA in determining sources only. A solicitation is not currently available.
THE VA IS NOT SEEKING PRICING OR OFFERS OF ANY KIND. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government.
The Cleveland Veterans Affairs Medical Center, in Cleveland, OH is seeking sources capable of complete the services described in the Performance Work Statement below: STATEMENT OF WORK (SOW) Fire Alarm Testing and Inspection 1. Contracting Officer s Representative (COR): TBD 2. Contract Title. Fire Alarm Testing and Inspection 3. Background. The Louis Stokes VA Medical Center, Cleveland, Ohio located at 10701 East Boulevard, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide on-site testing and inspection of government-owned Notifier fire alarm and fire suppression components required by NFPA, OSHA, TJC, and original equipment manufacturer standards and specifications necessary to maintain the current fire alarm system at top performance. 4. Scope. Contractor shall provide all labor, materials, equipment, transportation, and supervision necessary to provide on-site Annual, Semi-Annual, and Quarterly preventative maintenance testing (PMI s), inspection and maintenance on facility Notifier Fire Alarm System and associated equipment at the Wade Park facility of the Cleveland VA Medical Center, located at 10701 East Blvd., Cleveland, Ohio 44106. Fire alarm testing and inspection shall meet the requirements outlined NFPA 72, 2022 edition. Testing shall include all Joint Commission requirements. Some testing requirements will be met during off-hours or weekends. 5. Specific Tasks. 5.1. Task 1 Annual Testing Provide COR with testing schedule indicating dates of required testing. All Annual testing requirements (except elevator associated devices) will be started and completed in the month of January. Inspection reports shall consist of the following: Fire System Generated report identifying First page of report shall contain a summary of any device or system that did not pass and requires corrective follow-up. Pass or Fail for each device Date and time of each device tested
Microsoft Excel report Duplicating fire system generated report in well-organized divided sheets Report divided into tabs by device type Tab contents organized by device address First tab shall contain a summary of any device or system that did not pass and requires corrective action follow-up 5.2. Subtask 2 Semi-Annual Testing Provide COR with testing schedule indicating dates of required testing. All Semi-annual testing requirements will be started and completed in the month of July. Inspection reports shall consist of the following: Fire System Generated report identifying First page of report shall contain a summary of any device or system that did not pass and requires corrective follow-up. Pass or Fail for each device Date and time of each device tested Microsoft Excel report Duplicating fire system generated report in well-organized divided sheets Report divided into tabs by device type Tab contents organized by device address First tab shall contain a summary of any device or system that did not pass and requires corrective action follow-up 5.3. Subtask 3 Quarterly Testing Provide COR with testing schedule indicating dates of required testing. All Quarterly testing requirements will be started and completed in the months of January, April, July, and October. Inspection reports shall consist of the following: Fire System Generated report identifying First page of report shall contain a summary of any device or system that did not pass and requires corrective follow-up. Pass or Fail for each device Date and time of each device tested Microsoft Excel report Duplicating fire system generated report in well-organized divided sheets Report divided into tabs by device type Tab contents organized by device address First tab shall contain a summary of any device or system that did not pass and requires corrective action follow-up 5.4 Subtask 4 Elevator Device Testing All testing requirements for elevator associated devices will be started and completed in the month of February. Inspection reports shall consist of the following: Fire System Generated report identifying First page of report shall contain a summary of any device or system that did not pass and requires corrective follow-up. Pass or Fail for each device Date and time of each device tested Microsoft Excel report Duplicating fire system generated report in well-organized divided sheets Report divided into tabs by device type Tab contents organized by device address First tab shall contain a summary of any device or system that did not pass and requires corrective action follow-up 5.5 Subtask 5 Kitchen Hood Testing Provide COR with testing schedule indicating dates of required testing. Kitchen Hood Testing: Completed two times per year after 7pm M-F, June and December Report on company letterhead contains Company name Date of test Items tested and inspected Pass Fail for each item tested Pass Fail for each exhaust hood Itemized requiring corrective action follow-up 6. Deliverables: Fire Alarm contractor shall submit a site-specific safety plan outlining how inspections and testing will safely be conducted. This safety plan will be submitted to VA safety department for approval. SOW Task# Deliverable Title Format Number Calendar Days After Start 1 Site Specific Safety Plan Word - PDF
>30 days 2 Annual Testing Schedule Email Word - Excel
>30 days 3 Semi-Annual Testing Schedule Email Word Excel
>30 days 4 Quarterly Testing Schedule Email Word Excel
>30 days 5 Live Testing Schedule Email Word Excel
>30 days 6 HVAC Testing Schedule Email Word - Excel
>30 days 7 Atrium Smoke Detector Testing Schedule Email Word Excel
>30 days 8 Annual Test Report Email PDF - Excel
14 Days 9 Semi-Annual Test Report Email PDF Excel
14 Days 10 Quarterly Test Report Email PDF Excel
14 Days 11 Elevator Device Test Report Email PDF Excel
14 Days 12 Kitchen Hood Test Report Email PDF - Excel
14 Days
7. Contractor Responsibility:
Prior to bidding, it shall be the responsibility of the bidder to visit Cleveland VAMC and inspect the fire alarm system and facility to establish to their satisfaction the condition of the fire alarm equipment to be maintained and any other conditions affecting the work to be performed. This equipment is offered in an "as-is" condition. No claim shall be allowed for correction of deficiencies claimed to exist prior to award of contract.
This contract is a firm-fixed-price service contract, under which the contractor assumes the risk and full responsibility for the costs of performance and any resulting profit or loss, except to the limited extent that a valid contract change or other contractual remedy applies. Under the contract s Statement of Work (SOW), the contractor is required to provide all parts, materials, labor, supervision, test equipment, technical manuals, and transportation necessary to perform required preventive maintenance on the Government-owned Notifier fire alarm and fire suppression components at the Cleveland VAMC.
The SOW further requires the contractor to perform inspection and testing of the fire alarm system in accordance with NFPA 72-2022 and Joint Commission (TJC) standards, and to submit detailed test reports and field service documentation that meet those standards. Test reports shall be delivered in both Microsoft Excel, with device type separated by tab and report generated from Fire Alarm System.
The existing fire system is currently being upgraded, and this contract will incorporate the maintenance and inspection of all new system equipment and devices as they are put into service to include unlisted ancillary equipment and devices, and any devices or equipment added because of new construction or renovation during the performance period.
Quarterly meetings will be conducted with CO, COR, and contractor leadership. Quarterly meetings may be in-person or virtual. Contractor shall be currently engaged in maintenance, repair, inspection, and testing of Notifier Fire Alarm equipment. At bid submission, contractor shall provide proof of a minimum of five (5) years within the last seven (7) years of successful experience testing and maintaining Notifier Fire Alarm Systems identical to or similar to the size and complexity of facilities and system covered under this SOW. Offerors shall submit references for the five (5) years of experience including names, addresses, and telephone numbers of specific companies and key personnel to contact. The awarded contractor shall provide a Contract Manager who shall be responsible for the performance of the work. Contractor shall provide onsite Project Manager throughout the Annual and Semi-Annual testing period. The name of the Contract manager, alternate contract manager and onsite project manager shall be designated in writing to the CO/COR prior to the Contract start date. Changes to personnel shall be submitted to the Government within five (5) workdays of the changes. The Contract Manager or alternate shall have full authority to act on all Contract matters relating to the daily operation of the Contract. The Contract Manager or alternate shall be available to speak/meet with the CO or COR within 24 hours of request during normal operating hours, and or within the next business day after Friday or a Federal holiday. COR will reference the Quality Assurance Surveillance Plan to ensure contractor meets the deliverable requirements outlined in section 6 of this SOW. COR will ensure inspection reports are completed timely and uploaded into the VA maintenance records.
8. Check In Requirements: The Contractor Service Personnel and/or representative must report to the Electric Shop Supervisor within the engineering department or designated point of contact (POC) to sign in with department staff before work begins. Upon completion of work, the Contractor Service Personnel and/or representative must report to the appropriate department to sign out.
9. Security Requirements: The C&A requirements do not apply, and a Security Accreditation Package is not required.
9.1. Dedicated personnel will be assigned solely to observe, interact, assist, and assure protection of VA sensitive information.
9.2. Contractor employees providing services at VA facilities may undergo a security clearance in the form of a basic background investigation. 
10. General Security: Contractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.
11. VA Information Custodial Language:
11.1. Information made available to the contractor or subcontractor by VA for the performance or administration of this contract or information developed by the contractor/subcontractor in performance or administration of the contract shall be used only for those purposes and shall not be used in any other way without the prior written agreement of the VA. This clause expressly limits the contractor/subcontractor's rights to use data as described in Rights in Data - General, FAR 52.227-14(d) (1).
11.2. The contractor/subcontractor must store, transport, or transmit VA sensitive information in an encrypted form, using VA-approved encryption tools that are, at a minimum, FIPS 140-2 validated.
12. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI).
No government furnished equipment will be issued to complete the requirements of this contract.
13. Other Pertinent Information or Special Considerations.
Louis Stokes VAMC facility covers approximately 2 million square feet distributed between the following areas: Cares Tower Main Facility Atrium Women s Health Annex Learning Exchange Parking Garage The fire alarm system at Louis Stokes VAMC is currently being upgraded to a new Notifier system. Upgrade project will not be completed within the next 12 months Fire Alarm Reports will come from both systems to be complete. Coordination with fire alarm project will be required to schedule testing. Proof of testing and inspection on Notifier systems of similar size in five (5) of the last seven (7) years. All Annual testing requirements (except elevator associated devices) will be started and completed in the month of January. All testing requirements for elevator associated devices will be started and completed in the month of February. All Semi-annual testing requirements will be started and completed in the month of July. All Quarterly testing requirements will be started and completed in the months of January, April, July, and October. Kitchen Hood Testing: Completed two times per year after 7pm M-F June and December Weekly Fire Pump testing will be completed and documented by VA personnel Testing will require the following to complete: Climbing, bending, crawling Ladder use Vertical Scissor Lift. Lift not supplied by government. Magnet Notifier Keys Canned Smoke Laptop or Tablet to access CLSS Gateway network Any other tools/equipment contractor determines necessary to complete testing
VA personnel will assist contactor as needed to complete the following: Gain access to secure areas Locate difficult to find areas.
Efforts to minimize disruption to patients and patient care must be considered during scheduling and completing testing. May require after hours or weekend testing to support patient care. Federal holidays may be utilized with proper coordination with COR, approval from engineering management, and adequate VA staff to support contractor testing.
Elevator shaft and mechanical testing to be conducted over an identified weekend each February in coordination with the elevator contractor and VA electronics shop. Testing requires 1 fire alarm contractor technician for 10 hours over two weekend days (Saturday and Sunday)
Live Testing: Contractor shall provide requested schedule for required live testing no less than 30 days before required testing month. Live testing will be completed during an identified weekend during the annual testing period. Sundays are preferred testing day for live testing.
Pull station testing will be completed separately from other testing to minimize fire door activation and disruption to the facility. Pull station testing schedule will be provided by contractor and routed to VA for approval no less than 30 days before required testing month. Pull station testing can be coordinated to be completed over an approved weekend.
HVAC duct detector testing: Will be conducted in conjunction with the HVAC shop Testing schedule will be generated in advance and approved by all necessary parties Test results must verify and document the following: Fire damper activates HVAC unit shuts down HVAC unit able to be reset to normal after testing: Yes-No
Atrium Smoke Detectors Tested will be conducted on a scheduled Saturday (8 hours) Requires use of scissor lift Contractor will provide lift and lift operator. Ceiling height to atrium smoke detectors is 40 feet.
Tamper and Water Flow Testing Under TJC.02.03.05 and NFPA 25 Water Flow devices require quarterly testing (4 times per year January, April, July, October) NFPA 25 requirements include requirements for water to flow during this testing. Must operate flow valve and flow water to activate signal Tamper switches require semiannual testing (2 times per year January and July)
At bid submission, contractor must provide proof of ability to access and source necessary repair parts and programming for all Notifier Fire Alarm equipment installed within Louis Stokes VAMC. Contractor must demonstrate access to the following fire alarm system, vendor support and parts procurement: Notifier Dealer Notifier programming capability Notifier parts Notifier technical support Gateway / CLSS Testing reports generated through CLSS gateway at no additional cost to the government
Parking: Onsite parking is not available, and all contractor personnel will be required to obtain street side parking. a. Identification of Possible Follow-on Work.
Any additional repair or replacement work required outside this contract will require contractor to submit a quote to COR and receive an approved PO before beginning work.
b. Identification of Potential Conflicts of Interest (COI). None
c. Identification of Non-Disclosure Requirements. Not Applicable
d. Packaging, Packing and Shipping Instructions. None
e. Inspection and Acceptance Criteria. Contractor will be responsible for meeting all inspection and timelines listed in this SOW. 14. Risk Control Work performed within the medical center may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility. 15. Place of Performance.
Louis Stokes VA Medical Center 10701 East Blvd Cleveland, Ohio 44106 16. Period of Performance. Base Year: A date of award for duration of. 365 calendar days & 4 Option Years

Similar Contracts

Same NAICS industry code

NAICS: 561621
New
Centennial Fire Alarm & CO Detection Upgrade and Maintenance Services
Solicitation # centennial-fire-alarm-co-detection-upgrade-maintenance-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide fire alarm and carbon monoxide (CO) detection upgrade and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The primary objective is to restore the central Simplex 4020 Fire Alarm Control Center Panel and connected systems across nine campus facilities to full operational status. The scope of work includes diagnosing and clearing active trouble statuses, upgrading the panel motherboard or firmware if necessary, and integrating CO detection into the men's and women's dormitories by installing intelligent multi-criteria detectors and sounder bases. All work must adhere to NFPA 101 (2024), NFPA 72 (2025), IFC (2024), and local building and fire codes. Bids are due by December 1, 2026, and must be submitted to Sandra Clore. A mandatory physical site visit is required prior to bid submission. Proposals must include a detailed cost breakout, proof of insurance, and a signed bid form. For bids equal to or exceeding $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety company. This project is subject to the Davis-Bacon Act and Construction Wage Rate Requirements, necessitating the submission of weekly certified payroll reports for payment processing. The solicitation is open to small businesses, including certified VOSB, SDVOSB, WOSB, and HUBZone entities. Award decisions will be based on overall best value. Required deliverables include field service reports, a signed NFPA 72 inspection and maintenance form, and structured digital asset data for integration into the facility's Computerized Maintenance Management System. Compliance with various FAR clauses is required, including first-tier subcontractor reporting for awards over $40,000 and debarment disclosures for subcontracts exceeding $45,000.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 12 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 561621
New
SLED
FY27 DC OIG Fire Protection Systems Maintenance
Solicitation # Doc852355
The Government of the District of Columbia Office of the Inspector General (OIG) is soliciting a qualified contractor under solicitation Doc852355 to provide comprehensive inspection, testing, maintenance, and repair services for fire protection infrastructure located on the 10th, 11th, and 12th floors. The scope of work specifically covers Victaulic Series 769N pre-action fire sprinkler systems and Janus clean agent fire extinguishing systems. A critical requirement of this contract is the provision of expert advisory and management services to transition the Janus systems from 3M Novec 1230 to an approved alternative suppression agent, with the changeover required to be completed before the end of 2025. The contractor must assign technicians specifically trained in the maintenance of Janus and I-769N systems and must adhere to NFPA 25 and NFPA 72 standards, as well as FM Datasheets and LPCB/EN guidelines. Key deliverables include signed electronic maintenance reports submitted to the OIG Facilities Manager within 24 hours of each service and the maintenance of signed PM checklists on-site. The contractor is also responsible for providing formal training to the Facilities Manager on system operations and emergency response. Administrative requirements include coordinating all schedules with the Facilities Manager, providing Material Safety Data Sheets for hazardous materials, and submitting invoices through the designated e-invoicing system.
Inspector General (OIG)

POSTED

1 day ago

DEADLINE

in 5 days
View Details
NAICS: 561621
New
SLED
Request for Information - OpenEye – CCTV Recording and Analytics
Solicitation # TCH2133148F1
Broward County has issued a Request for Information (RFI) under solicitation number TCH2133148F1 to determine if the OpenEye CCTV recording and analytics solution is available from multiple providers or if an alternative commodity can meet the County's specific needs. This process serves as a Notice of Intent to Designate Sole Source/Sole Brand and is not a request for pricing or a purchase commitment. The County is seeking a turnkey appliance featuring a hybrid architecture that integrates cloud management with on-premise video storage. The required solution must demonstrate advanced capabilities in architecture and system integration, including vendor-agnosticism and Genea access control integration. Key technical requirements include real-time person-of-interest identification, license plate recognition, and the ability to run simultaneous analytics across both legacy and new cameras. From a security and management standpoint, the system must utilize hardened Linux-based recorders, support Role-Based Access Control, and be proven secure via Nessus vulnerability scans with zero critical, high, or medium-level vulnerabilities. Additionally, all hardware must be backed by a full manufacturer's warranty and dedicated factory technical services. Interested vendors must submit responses via the electronic bidding system by November 16, 2026.
Broward County

POSTED

1 day ago

DEADLINE

in 23 days
View Details
NAICS: 561621
New
International
Video Management System Migration: Genetec
Solicitation # VA/CON/F26/40
The Victoria and Albert Museum is seeking a Genetec partner under solicitation VA/CON/F26/40 to supply, install, and implement a video storage solution. The project involves migrating all video surveillance cameras to a Genetec recording and storage platform across four locations: the V&A South Kensington site and three remote sites at Young V&A, Park Royal, and Dean Hill Park. The scope of work includes the provision of hardware such as Streamvault recording servers and Cloudlink devices, Genetec software licenses and support for a 12-month period, and professional services for configuration, installation, and integration. All deliverables must adhere to the museum's specific surveillance and retention standards, with a focus on ensuring seamless connectivity and management through the Genetec platform. The contract has an estimated total value of 443,000 GBP excluding VAT and is open to small and medium-sized enterprises. Award decisions will be based on the most advantageous tender, weighted 60 percent on quality and 40 percent on whole life cost. The procurement process follows a two-stage competitive flexible procedure, beginning with a pre-qualification questionnaire and followed by a formal tender for a shortlist of four to six suppliers, including mid-tender dialogue workshops. The estimated award decision date is December 3, 2026. The museum retains the right to vary the volume of services, make additional purchases, and extend the warranty period for an additional year.
Victoria and Albert Museum

POSTED

1 day ago

DEADLINE

N/A
View Details

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 811210
New
Federal
J066--Sakura Service Agreement | Base 4OY | Start: 1/21/27 | Columbus VAACC
Solicitation # 36C25027Q0049
The Department of Veterans Affairs Network Contracting Office 10 is soliciting a full-service maintenance agreement for Sakura instruments located at the Chalmers P. Wylie Ambulatory Care Center in Columbus, Ohio. The scope of work includes planned and corrective maintenance, emergency services, labor, parts, technical support, and travel for Sakura Tissue-Tek processors, Tissue Tek Film CoverSlipper systems, and Tissue Tek Prisma Plus equipment. All services must be performed by qualified field service engineers in accordance with Original Equipment Manufacturer (OEM) specifications. The contract period consists of a base year starting January 21, 2027, with four optional one-year extensions. Award will be based on the Lowest Price Technically Acceptable (LPTA) evaluation method. To be eligible, offerors must provide proof of OEM authorization to perform the required maintenance and repair services at the time quotes are due. Technical submissions must include a detailed maintenance plan, evidence of competency and proficiency with the specified equipment, and a narrative response. The contractor is required to provide field service reports upon completion of work and maintain calibration certifications for all test equipment traceable to OEM standards. Performance hours are designated as Monday through Friday, 7:00 am to 5:00 pm, excluding federal holidays.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 238210
New
Federal
J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland
Solicitation # 36C25027Q0014
The Department of Veterans Affairs is seeking a small business contractor to provide on-site electrical power distribution equipment testing, inspection, and maintenance for the Louis Stokes Cleveland VA Medical Center. This firm-fixed-price contract includes a base year starting November 1, 2026, with four optional one-year extensions through October 31, 2031. The scope of work encompasses annual preventative maintenance inspections, tri-annual testing of power distribution equipment, and the maintenance of substations and transformers. Specific technical requirements include the testing of 33 medium-voltage switches, 37 Schweitzer Engineering Laboratories protective relays, and one medium-voltage switchgear battery backup system, all operating at 11 kV. The contractor is also responsible for annual infrared inspections and the replacement or refilling of transformer cooling liquid as needed. To be eligible, the prime contractor must specialize in electrical testing and maintenance and possess at least five years of relevant experience. Personnel must be NETA-certified or hold an equivalent NICET Level III certification or higher. While subcontractors may be used, the prime contractor must perform a substantial portion of the technical work and cannot act solely in an administrative or oversight capacity. Work requiring power interruptions will be scheduled for Sundays during daylight hours, while non-disruptive tasks may occur during normal weekday hours. Award will be based on a comparative evaluation where technical capability and past performance are weighted more heavily than price.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

3 days ago

DEADLINE

in 6 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS