Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 28, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J041--Replace/Upgrade 10 Kitchen and Canteen Cooler and Freezer Condensers

Closed
36C24925Q0204Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
ANNUAL ROTATING EQUIPMENT INSPECTION, TESTING, REPAIR, RECONDITIONING AND STORAGE SERVICES
Solicitation # 2026-RFP-130
Solicitation 2026-RFP-130, issued by the City of Lakeland, seeks qualified contractors to provide annual inspection, testing, repair, reconditioning, and storage services for critical rotating equipment at the McIntosh and Larsen Power Plants. The scope of work covers a wide range of industrial machinery, including low- and medium-voltage AC and DC electric motors, as well as circulating water and condensate pumps. Required services include clean inspect test (CIT) procedures, troubleshooting, motor rewinding, machining, welding, and dynamic field balancing. The contractor is also responsible for the pickup, transportation, and secure indoor storage of equipment, ensuring strict preservation measures such as periodic shaft rotation and moisture control to prevent corrosion and damage. The selection process is based on a points-based criteria to identify the vendor most responsive to the city's needs. Proposers must submit their responses via the OpenGov portal by October 30, 2026, and provide essential documentation including a signed W-9, Sunbiz registration, a notarized indemnification agreement, and a human trafficking affidavit. Contractors must adhere to strict safety standards, including OSHA compliance and specific certification for crane operations and critical lifts. Furthermore, vendors are required to maintain insurance policies with AM Best ratings of no less than A and must undergo a safety audit covering EMR and employee training records to ensure compliance with city risk management standards.
LE - Production - MPP

POSTED

about 6 hours ago

DEADLINE

in 8 days

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Department of Veterans Affairs Lt. Col. Luke J. Weathers VA Medical Center 116 N Pauline St, Memphis, TN, 38105, USA

Set-Aside

NONE

Documents

2

Amendment 0001 - Solicitation 36C24925Q0204 (Refrigeration Service)

DOCX, High priority: read this first1 page · amendment
High

36C24925Q0204 - Replace/Upgrade 10 Kitchen and Canteen Cooler and Freezer Condensers

DOCX, Low priority9 pages · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Notice updated

Notice details unchanged. Attachments may have changed.

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)
Contacts1 person available
OfficeMURFREESBORO, TN, 37129, USA
Office AddressMURFREESBORO, TN, 37129, USA
Contacts
Kristie CollinsContract Specialist

Full Description

Show more
On behalf of the Memphis VA Medical Center, Network Contracting Office (NCO) 9 is issuing this Sources Sought Notice (SSN) as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for a firm-fixed-priced purchase order for replacement and upgrade of ten (10) kitchen and canteen cooler and freezer condensers in locations CW232, CW233, CW235A, CW240, CW241, CW242, CW248, CW250, CW254A, CW254-B due to malfunctioning equipment and refrigerant leaks at the Lt. Col. Luke Weathers, Jr. Campus at 116 N Pauline St, Memphis, TN 38105. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. 1. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for bids, proposals, or quotes; submission of any information in response to this market survey is purely voluntary; and the government assumes no financial responsibility for any costs incurred. 2. If your organization has the potential capacity to perform these services, please provide the following information: a. Organization name, address, point of contact, email address, web site address, and telephone number. b. Business size: small, small disadvantaged, woman-owned, Hub Zone, serviced-disabled veteran-owned small business (SDVOSB), veteran owned small business (VOSB), large business, etc. c. Business type under NAICS 811310, which contains a size standard of $12.5 million, Commercial and Government Entity (CAGE) Code and System for Award Management (SAM) Unique Entity ID (UEI) number. d. Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational, and staff capability. e. Responses to this SSN shall not exceed 4 pages and should include all the foremost mentioned information. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe Portable Document Format (PDF). f. The government will evaluate market information to ascertain potential market capacity to: i. Provide services consistent in scope and scale with those described in this notice and otherwise anticipated. ii. Implement a successful plan that includes contractor compliance with program standards, quality control, and performance. iii. Provide services under a firm-fixed-price contract. 3. NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and verified in Veteran Small Business Certification (VetCert) https://veterans.certify.sba.gov. 4. Based on the responses to this SSN/market research, this requirement may be set-aside for SDVOSBs, VOSBs, small businesses, procured through full and open competition, or sole sourced. 5. Submission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this SSN by 12:00 PM EST, March 27, 2025. All responses under this SSN must be emailed to contact@example.gov . Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. 6. SAM: Interested parties shall be register in the System for Award Management (SAM) as prescribed in Federal Acquisition Regulation Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling +1 (555) 000-0000. 7. Disclaimer and Important Notes. This notice does not obligate the government to award a contract or otherwise pay for the information provided in response to this SSN. The government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the government to determine the organization s qualifications to perform the work. Respondents are advised that the government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation or combined solicitation may be published in Contract Opportunities (formerly Federal Business Opportunities or FBO). However, responses to this notice shall not be considered adequate responses to a solicitation. 8. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The government reserves the right to use any non-proprietary technical information in any resultant solicitation(s). 9. See CLIN structure on the following page. 10. See Statement of Work (SOW) on the following page. CLIN: ITEM # DESCRIPTION QTY UOM UNIT PRICE Extended Price 0001 Refrigerant Recovery Tanks 10 EA - 0002 3/4 - Hp Cooler Refrigeration Condenser Systems CW232, CW233, CW250 and CW254B 4 EA - 0003 3/4 - Hp Cooler Evaporator Fan Coil System CW232, CW233, CW250 and CW254B 4 EA - 0004 1 - Hp Cooler Refrigeration Condenser System CW248 1 EA - 0005 1 - Hp Cooler Evaporator Fan Coil System CW248 2 EA - 0006 1.5 - Hp Cooler Refrigeration Condenser System CW242 1 EA - 0007 1.5 - Hp Cooler Evaporator Fan Coil System CW242 2 EA - 0008 5.5 - Hp Cooler Refrigeration Condenser System CW241 1 EA - 0009 5.5 - Hp Cooler Evaporator Fan Coil System CW241 2 EA - 0010 6 - Hp Cooler Refrigeration Condenser System CW240 1 EA - 0011 6 - Hp Cooler Evaporator Fan Coil System CW240 2 EA - 0012 3.5 - Hp Cooler Refrigeration Condenser System CW235A 1 EA - 0013 3.5 - Hp Cooler Evaporator Fan Coil System CW235A 1 EA - 0014 2 - Hp Cooler Refrigeration Condenser System CW254A 1 EA - 0015 2 - Hp Cooler Evaporator Fan Coil System CW254A 1 EA - 0016 Steel Frames for condensing Unit Mounting 3 EA - 0017 Lot Refrigeration 1 EA - 0018 # R-410 Refrigerant 175 LB - 0019 Lot Refrigerant Piping 1 BD - 0020 Lot Refrigerant Piping Insulation 1 RO - 0021 Lot Refrigerant Piping Hangers and Supports 1 BX - 0022 Lot Drain Piping 1 BD - 0023 Equipment Rails Units CW254A & CW352B 1 BD - 0024 Pipe Penetration Curb Units CW254A & CW254B 1 BD - 0025 System warranties 10 EA - 0026 Electrical Connections 1 BD - 0027 Roofing 1 EA - 0028 Labor to include: Disconnect, removal and disposal of 14 in total existing fan coli units and condensing units, System Start-up, Crance Services installation of new systems. 1 JB - KITCHEN COOLER / FREEZER UPGRADE STATEMENT OF WORK Upgrade and Replace All Line Sets, Condensers, Evaporators, & Electrical Lt. Col Luke Weathers Jr. Memphis VA Medical Center, Memphis, TN 38105 GENERAL: Lt. Col. Luke J. Weathers VAMC needs an upgrade of its Kitchen & Canteen Cooler/Freezer Condensers, Evaporators units and Electrical components that are due for replacement. The purpose of the Ten (10) kitchen cooler and freezer upgrade is due to malfunctioning equipment and refrigerant leaks. The major leaks are an EPA violation. SCOPE OF WORK: The contractor shall provide upgrade services, including all labor, supplies, tools and/or equipment required to replace and upgrade all condensers and evaporators in the kitchen. Contractor is to remove all equipment from all locations in the kitchen. Upon completion of replacement parts and upgrade services, the contractor shall perform an operational test of the equipment to ensure operations and functionality of upgraded equipment. The operations test should be performed in the presence of the COR, graphic, or a/c shop representative. The normal hours of work for this service will be 8:00am until 4:30pm, Monday through Friday. The work shall be completed within 10 working days from the date the contractor arrives on site. Once the contractor receives the PO, the contractor needs to reach out to the COR to set a time and date of equipment and technician to arrive at the Lt. Col. Luke Weathers Jr. Memphis, VA Medical Center for upgraded parts and services. Contractor is expected to be on site to perform services within 60 days of receiving the PO and excepting the contract. The Maintenance and Operations Supervisor/COR will issue necessary keys/cards to the contractor. The keys/cards issued are to remain government property. The contractor or his representative will be required to sign for receipt of any keys/cards issued. The keys/cards must be returned to the Maintenance and Operations Supervisor/COR upon completion of work. The contractor s and/or staff will check in with the COR, graphic, or a/c shop representative to receive a VA work authorization badge. The badge must be worn facing forward and above the waistline. The contractor and/or staff are required to wear the VA always issued badge while on the VA premises. Upon completion of repairs services, the contractor shall remove debris, old parts and other items not installed as part of the repair service from the elevator machine room. Contractor and/or their staff are not permitted to take any pictures or videos of any type. Taking of photographs/videos are prohibited while on VA premises. LOCATION: The locations are CW232, CW233, CW235A, CW240, CW241, CW242, CW248, CW250, CW254A, CW254-B. SALIENT CHARACTERISTICS: We shall include the following: Refrigerant Recovery per EPA regulations for (10) existing Refrigeration Systems Disconnect, removal and disposal of existing Fan Coil Units (4) ¾-hp Cooler refrigeration systems w/ single Fan Coil; Systems 232,233,250, 254B (1) 1-hp Cooler refrigeration system w/ dual Fan Coils; System 248 (1) 1-1/2 hp Cooler refrigeration system w/ dual Fan Coils; System 242 (1) 5-1/2 hp Freezer refrigeration system w/ dual Fan Coils; System 241 6 hp Freezer refrigeration system w/ dual Fan Coils; System 240 3.5hp Freezer refrigeration system w/ single Fan Coil; System 235A 2hp Freezer refrigeration system w/ single Fan Coil; System 254A All system Condensing Units equipped with Liquid and Suction Line Filter Driers, Sight Glass, Service Valves, Compressor Crank Case Heater, Headmaster Low Ambient Control, Time Clock, and Factory Housing. All Fan Coil Units equipped with factory mounted TXV, Solenoid Valve and Temperature Control All Cooler Units to be Air Defrost (no defrost heaters), Freezers Units equipped with Electric Defrost All units operate with R-404a Refrigerant. Kitchen Condensing Units to be mounted on existing roof runners with steel frames for additional support. New Refrigerant Piping w/ Hard Drawn ACR Copper sized by Equipment Manufacturer Unistrut Cushion Clamps for Liquid line piping Unistrut Closure Clamps for Suction lines Suction line insulation: Cooler ½ wall thickness, Freezer ¾ wall thickness. Suction line insulation to be slid over pipe and taped at butt end joints. Reconnection of existing line voltage wiring, and new electrical circuit breakers as needed by Licensed Electrical Contractor Equipment Rails and Pipe Penetration Curb with Roofing Included, Units 254A & 254B. System Evacuation, Start-up, and Test by qualified Technician Year Parts & Labor Warranty, (5) year Compressor Warranty Qualifications and Exclusions: All work in open floor area of Kitchen to be after hours. All work at immediate perimeter and inside of refrigerated compartment to be performed during regular hours. All work on roof to be during regular hours. Ceiling Tiles removed for installation of piping will be reinstalled at the end of each shift. Work area to be cleaned up at end of each shift, all materials and equipment shall be stored in a location and manner so as not to interfere with Kitchen operations. VA Personnel to deactivate / reactivate fire alarm for inside work as needed. Compressor Room demo Excluded. Existing above ceiling refrigerant piping Demo Excluded No Roofing Work other than specified above PLACE OF PERFORMANCE: Lt. Col Luke Weathers, Jr. VA Medical Center 116 N. Pauline Street Memphis, Tennessee 38105 PERFORMANCE PERIOD: N/A U.S. LEGAL HOLIDAYS: The following is a list of U.S. Government holidays. If the holiday falls on a Saturday, the proceeding Friday is observed as the holiday, if the holiday falls on a Sunday, the following Monday is observed as the holiday. New Year s Day Martin Luther King s Birthday Washington s Birthday Memorial Day Juneteenth National Independence Day Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day

More opportunities from Department Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)

Same awarding agency

NAICS: 621111
New
Federal
Q501--Locum - Anesthesiology Physician Services - 621 5-YR w/Orders 4/1/27-3/31/32
Solicitation # 36C24927Q0035
The Department of Veterans Affairs, Veterans Health Administration, is conducting market research through a Sources Sought Notice to identify qualified sources for locum tenens anesthesiology services at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The requirement involves providing board-certified anesthesiologists to support surgical and procedural operations, including pre-operative evaluations, anesthesia administration, post-anesthesia care, and emergency services. The anticipated period of performance is five years, projected from April 1, 2027, to March 31, 2032. On-call coverage is required for weekdays from 5:30pm to 7:00am and 24-hour coverage on weekends, with strict response times of 15 minutes by phone and 30 minutes for on-site arrival. The potential contract falls under NAICS code 621111 with a small business size standard of 16 million dollars. Interested respondents must maintain active registration in the System for Award Management and those claiming SDVOSB or VOSB status must be verified through the Small Business Administration. Performance will be monitored via a Quality Assurance Surveillance Plan using Focused and Ongoing Provider Practice Evaluations, with a 100 percent acceptable quality level for patient access and safety reporting. All personnel must hold full and unrestricted licenses, possess National Provider Identifiers, and complete mandatory VA training in HIPAA, infection control, patient safety, and cybersecurity.
Offices of Physicians (except Mental Health Specialists)

POSTED

about 7 hours ago

DEADLINE

in 18 days
View Details
NAICS: 561320
New
Federal
R425--Temporary Operations and Maintenance Staffing Services for Skilled Trades Louisville VA Medical Center, Kentucky
Solicitation # 36C24927Q0030
The Department of Veterans Affairs is conducting market research to identify qualified businesses for temporary operations and maintenance staffing services at the Louisville VA Medical Center, including the New Louisville and Robley Rex facilities and other catchment area locations. This requirement focuses on supporting facility activation, commissioning, and ongoing operations for mission-essential healthcare infrastructure and life-safety systems. The anticipated contract structure includes a 12-month base period with two one-year option periods and is designated as a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS code 561320. The scope involves recruiting and supervising skilled trades personnel, with estimated staffing needs for eight Utility Systems Repairer-Operators, four HVAC Mechanics, four Maintenance Mechanics (Multi-Trade), and three Pipefitters/Plumbers. Contractors must provide all necessary tools, PPE, and uniforms, while ensuring personnel meet strict qualifications, such as three years of relevant experience and specific certifications like EPA Section 608 for HVAC roles. Key performance requirements include providing routine staffing within 10 business days, filling critical vacancies within five business days, and maintaining 24/7 coverage for USRO personnel. All staff must pass VA background investigations, obtain PIV badges, and comply with OSHA, NFPA, and infection-control standards.
Temporary Help Services

POSTED

1 day ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS