Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on December 19, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J061--Annual Automatic Transfer Switch Testing and Imaging

Closed
36C24123Q0188Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 7 hours ago

DEADLINE

in about 2 months
NAICS: 811310
New
SLED
Roseville Electric Utility – Gas Compressor Maintenance
Solicitation # 07-137
The City of Roseville is soliciting proposals for Gas Compressor Maintenance Services to support the Roseville Energy Park and the Roseville Energy Center and RPEAK. The selected contractor will provide all labor, supervision, technical expertise, specialized tooling, equipment, and materials necessary for both scheduled preventive and corrective maintenance on natural gas compressors, specifically Gas Packagers and Ariel models, and their associated auxiliary systems. The contract is intended to run for an initial term of five years, with services estimated to commence in April or May. This is a prevailing wage project requiring adherence to all fair employment laws, with certified payroll required for contracts exceeding 25,000 dollars. The successful proposer must provide a 100 percent Faithful Performance Bond and a 100 percent Labor and Materials Bond. Proposals are due by December 17, 2026, and must include a Proposer’s Certification, a Non-collusion Declaration, a Levine Act Disclosure Statement, and proof of active registration with the California Secretary of State. Award will be made to the responsible proposer determined to be the most advantageous to the City through a formal evaluation panel process. Invoicing is to be submitted monthly, delineated by task and personnel, with payment terms set at 30 days following receipt of satisfactory services.
City of Roseville

POSTED

about 7 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

1400 VFW Parkway, West Roxbury, ME, 02132, USA

Set-Aside

NONE

Documents

1

36C24123Q0188.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Timothy FelixContract Specialist

Full Description

Show more
THIS SOURCES SOUGHT/REQUEST FOR INFORMATION IS ISSUED FOR INFORMATION AND PLANNING PURPSOES ONLY AND IS NOT CONSIDERED A SOLICITATION. The purpose of this sources sought/RFI is to gain knowledge of businesses that are capable of satisfying the following work requirement: STATEMENT OF WORK ATS Testing and Imaging 1.0 Scope of Work The contractor will perform annual Automatic Transfer Switch testing and imaging at the Boston Healthcare System, West Roxbury Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work. All Transfer Switch Testing shall occur during off hours (10:00 PM 7:00 AM) Place of Performance: 1400 VFW Parkway, West Roxbury, MA, 02132 Period of Performance: one base year plus four option years. Exercising an option is up to the discretion of the contracting officer. 2.0 Performance Requirements INFRARED THERMAL IMAGING Thermal infrared imaging of both the normal and emergency power poles shall be done during annual testing. The transfer/bypass switch shall be in the emergency position for 30 minutes, prior to the imaging pictures taken to allow for any temperature rise. Reports of anomalies shall include a color photograph of the switch being tested & a color thermal imaging print. The report information shall be similar to test report a attached and made part of this standard. Both the transfer switch & bypass contacts shall be scanned. The following standards, as applicable, shall be part of the testing requirements: NFPA-70 (national electric code) NFPA-70B (electrical equipment maintenance) nfpa-70e (electrical safety in the workplace) nfpa-99 (health care facilities) NFPA-101 (life safety code) NFPA-110 (emergency and standby power systems) nfpa-20 (stationary pumps for fire protection) ansi/neta-mts (maintenance testing specifications) ma elevator regulations (524 cmr) TESTING REQUIREMENTS In-phase monitors (sync check relays) In-phase monitors shall be checked for calibration and shall be set for + or 7 degrees maximum. Relay output contacts shall be tested, Dead bus relay outputs shall be confirmed and maximum slip rate shall be noted on the test reports. VOLTAGE & FREQUENCY SENSORS All voltage and frequency sensors for both normal and emergency shall be calibrated with a three-phase test set, using calibrated meters for all pickup & dropout values. All results, including as found and as left settings shall be noted on the test reports. AUXILIARY CONTACTS & SPECIAL TIMED CONTACTS All auxiliary position contacts shall be tested in both positions and so noted in the test reports. All auxiliary contact functions such as Normal Power Available , Emergency Power Available , ETC. Shall be verified and noted in the test reports. TIMER CALIBRATION AND OPERATION CHECKS The following timers shall be checked for accuracy and so noted in the test reports: Time delay, engine start. Time Delay, transfer to Emergency. UMD Timer for Pre, Post, or Both. . T3/W3 elevator presignal time delay w/ bypass. Time delay, retransfer to normal. (set at 30 minutes) Time delay, engine cool down. (set at 300 seconds) Time delay neutral position on Delayed transition switches. LOAD SHED, BLOCK TRANSFER & RE-ADD CRKTS. Special custom Load shed, Block Transfer & Re-add circuits shall be verified to be operational and be noted on the test reports. (If applicable) VERIFY TOTAL POWER FAILURE TO RESTORATION OF LOAD FROM EMERGENCY GENERATOR Time delay, engine start = 1 or 3 seconds (Engineering Dept to specify actual time) Time delay, transfer to emergency = .1-15 seconds (Engineering Dept to specify actual time) Time delay, presignal = 10-20 seconds (Elevator contractor to specify actual required time) Time delay, load shed = 1-30 seconds (Engineering Dept to specify actual required time delay) Engine up to speed time = typical 4.5-6 seconds Retransfer to normal position = 5 minutes Ensure total transfer time on Critical or Life Safety switches do not exceed 10 seconds. Ensure that Elevator transfer switches transfer within 10 seconds, or as allowed by Mass Elevator Regulations (524 CMR) which is typically 25 seconds. BYPASS/ISOLATION SWITCH TESTS Provide bypass to normal and bypass to emergency operations with Isolation option for each. Ensure no load-break condition exists. (Switch must be a make-before-break arrangement) If switches are of the Load-break design, Engineering will establish the time & date for these tests. Verify Manual Transfer switch function of Bypass switch. (Manual Transfer Switch Operation) Ensure engine start contacts stay closed with ATS module out in Isolate position After switch is isolated, rack ATS module back into the TEST position and cycle the switch through a complete sequence. Follow manufacturer s instructions for returning switch to normal operating position Verify B/I module relays are properly energized and that all blocking interlocks are operating correctly. Verify all auxiliary and B/I engine start contacts. QUALIFICATIONS FOR BIDDERS: Qualified Bidders Shall be NETA certified Company and either Factory Trained & Authorized or Factory Trained on the Equipment to be tested. (General Electric, Zenith Controls, Russelectric, Pace, Asco, Westinghouse, Kohler, and Generac) and have a minimum of 20 years of experience, as many of the VA sites have older gear operating on site in excess of 15 years. The Field Engineer/Technician shall also be a Certified Level 2 or greater Thermographer. TEST REPORT REQUIREMENTS: Test Reports are required to document results of each switch. PREMIUM TIME WORK: Bidders are reminded that all work must be done on premium time as designated by the contract. PLEASE NOTE: TESTING OF BYPASS/ISOLATION SWITCHES REQUIRES ADDITIONAL TESTING CRITERIA DIFFERENT AND IN ADDITION TO A STANDARD ATS. Bid prices shall be per unit and Campus may add or delete units from their BOM. All services & inspections shall be scheduled thru COR. No additional work can be performed under this contract, and no changes to this Scope of Work can be made without the authority and prior approval of the Contracting Officer. Equipment to be serviced: ATS Inventory - Designation Make Model Serial Controller Location EE# 1 B1-1 Russelectric RTBD-4004CEF 30535-1 A/8 2000 B1 82503 2 B1-2 Russelectric RTBD-4004CEF 30535-2 C/D 2000 B1 82502 3 B1-3 Russelectric RTBD-6004CEF 30535-2 A/8 2000 B1 82495 4 B1-4 Russelectric RTBD-6004CEF 30535-2 C/D 2000 B1 82498 5 B1-5 Russelectric RTBD-4004CEF 30535-1 E/F 2000 MCC431-01-WR 82501 6 B1-6 (Fire pump) Zenith - - GD130-01-WR 56611 7 B1-7 Russelectric RTBD-6004CEF 30535-2 E/F 2000 A3E-06 (B1) 82497 8 B1-8 Russelectric RTBD-6004CEF 30535-2G/H 2000 A3 061 (B1) 82504 9 B1-10 Russelectric RTBDLBCT-8004CEF 35621-2A/B 2000 B1 136551 10 B1-11 Russelectric RTS03-ABLB6004AMF1 36512-1A/B RPTCS B1 147444 11 Emg Light Relays - - Auditorium - 12 A3C-1 (ATS-2) Russelectric RTB-4004CEF 24509-3A/B 2000 B2 62947 13 A3C-2 (ATS-1) Russelectric RTB-2604CEF 24509-1A/B 2000 B2 62948 14 A3C-3 (ATS-8) Russelectric RTB-4004CEF 35621-1A/B 2000 B2 136550 15 A3C-4 (ATS-11) Russelectric RTS03-ABLB4004AMF1 39016 -1A/B RPTCS - 16 A3S-1 (ATS 5) Russelectric RTB-2604CEF 24509-1C/D 2000 B2 62945 17 A4E-1 (ATS 4) Russelectric RTB-4004CEF 24509-2A/B - B2 62946 18 A4E-2 (ATS 6) Russelectric RTB-4004CEF 29772-1A/B 2000 B2 73136 19 A4E-3 (ATS 10) (Fire pump) Zenith - - B2 72469 20 A4E-4 (ATS-3) Russelectric RTB-4004CEF 31010-1 A/B - B2 83279 21 A4E-5 (ATS-9) Russelectric RTBDLB-6004CEF 35145-1 A/B 2000 B2 136549 22 A4E-7 (ATS-7) Russelectric RTS03-ABLB8004AMF1 36466-1A/B RPTCS B2 168928 23 ATS- (Mobile OR) GE - - B2 73137 25 B8-Boiler Russelectric RTS03-ABLA4004AMF1 36608-1A/B RPTCS B8 140803 26 B20-Research Russelectric RTS03-ABLB8004AMF1 38472-1A/B RPTCS B20 - 27 B21-Research Russelectric RTBDNB-6004CEF 35273-1A/B 2000 B21 136548 28 B3-1 Russelectric RTBD-1004CEF 29772-2A/B 2000 B3 71293 29 B3-2 Russelectric RTBDLB-4004CEF 33859-2C/D 2000 B3 104155 30 B3-3 Russelectric RTBDLB-4004CEF 33859-2A/B 2000 B3 104153 31 B3-4 Russelectric RTBDLB-6004CEF 33859-1A/B 2000 B3 104154 32 B3-5 Russelectric RTBDLB-4004CEF 37890-1A/B RPTCS B3 167460 33 Garage Russelectric - RPTCS Garage - 34 Garage Russelectric - RPTCS Garage - Responses to this sources sought will be used by the government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement. Responses to this sources sought/RFI are due by 12PM EST time on December 23, 2022. Responses to this notice shall be submitted via email to contact@example.gov. telephone responses shall not be accepted. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The NAICS code for this requirement is 811310 and a small size standard of $11,000,000.00.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 532490
New
Federal
W038--Rental & Support Services for Wheeled Loaders w/3yard bucket
Solicitation # 36C24126Q0815
The VA Maine Healthcare System Togus is seeking a qualified vendor under a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to provide month-to-month rental and support services for two wheeled loaders and snow removal attachments. The equipment, specified as CAT 926 or CAT 930 models weighing between 27,972 and 31,124 lbs, will be used for snow removal at the Togus VAMC campus in Augusta, Maine. Requirements include a 3-yard bucket with a Fusion coupler, 160 to 170 hp Tier 4 Final engines, ROPS/FOPS certified cabs, and liquid-filled tires. The contractor must provide 24/7 service and support, with repairs initiated within 24 hours of notification or the provision of a replacement loader at no additional cost. All preventive maintenance, repairs, and delivery/pickup charges must be included in the firm fixed price quote. The procurement is governed by NAICS code 532490 and follows FAR subpart 12.6 streamlined procedures. Award will be based on a comparative evaluation of technical capability, past performance, and price, with the contract awarded to the responsible vendor who is technically acceptable and offers the lowest evaluated price. Vendors must submit a firm fixed price quote, a technical capability statement, and a signed Limitation of Subcontracting certificate. Strict security and health protocols apply, including mandatory security badging, adherence to VA non-smoking policies, and proof of vaccinations for influenza, COVID-19, and tuberculosis testing for all personnel accessing the station. All quotes must be submitted to the designated contact by November 2, 2026, at 5:00 PM EST.
Other Commercial and Industrial Machinery and Equipment Rental and Leasing

POSTED

about 12 hours ago

DEADLINE

in 5 days
View Details
NAICS: 238990
New
Federal
Amendment 0001- Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting a contract for a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The objective is to return the damaged sections to their original alignment, configuration, appearance, structural stability, and security function. The benchmark product is the Ameristar Impasse Trident system, and while genuine components are preferred, equal alternatives may be proposed if they meet all salient characteristics, including the use of corrosion-resistant tamper-resistant hardware and the maintenance of a continuous security boundary. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238990. The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award decisions will be based on the most advantageous offer, considering price, technical capability, and past performance, with a requirement for three relevant references. Proposals must be submitted in three separate PDF volumes (Technical, Past Performance, and Price) to the contract specialist by November 5, 2026. Final acceptance is contingent upon a satisfactory installation inspection, which may include a review by VA Police to ensure operational security.
All Other Specialty Trade Contractors

POSTED

about 12 hours ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS