Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on September 23, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J061--Generator Maintenance, Testing & Inspection

Closed
36C25025Q0973Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include the replacement of friction discs, bearings, oil seals, and O-rings, as well as resurfacing the flywheel and replacing hydraulic pipes and filters as necessary. All work must adhere to manufacturer specifications, and the final acceptance is contingent upon the Facility Maintenance Department verifying proper clutch engagement and PTO operation under load. This is a fee-for-service solicitation with a lump sum award based on best value. Interested offerors must submit a bid sheet, a completed supplier packet including a W-9 and self-certification form, and proof of insurance by November 3, 2026. The contract is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone concerns, and requires compliance with various Federal Acquisition Regulations, including Service Contract Labor Standards and Buy American provisions. Proposals must include an itemized breakdown of costs and warranty information for parts and labor.
Earle C. Clements Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in 6 days

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Ann Arbor VA Medical Center 2215 Fuller Road Ann Arbor, MI 48105, OH, USA

Set-Aside

NONE

Documents

1

36C25025Q0973 - Generator Maintenance, Testing & Inspection

DOCX, Low priority6 pages · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
Contacts
Jeannie OrtizContracting Officer

Full Description

Show more
This is a Sources Sought Notice for Generator Maintenance, Testing & Inspection services as identified in the Statement of Work (SOW) for the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below. A DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice. Please respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response: SAM UEI NUMBER provide this in the email text GSA Contract Number provide this in the email text Capabilities Statement Confirmation of actual intent to submit an offer should an RFQ be posted in future Company name and address Point of contact information (name, phone, email) Socioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.) provide this in the email text This Sources Sought Notice is intended to locate any business capable of performance. The anticipated NAICS Code for this requirement is 811310. This is not a Request for Quotation and quotes shall not be reviewed at this time. The Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. Responses shall be submitted to Jeanne Ortiz at contact@example.gov by Wednesday, October 8, 2025, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25025Q0973 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE. DRAFT STATEMENT OF WORK GENERAL Contractor shall provide all parts, tools, materials, labor, supervision, test equipment, technical manuals and transportation necessary to perform annual maintenance on government-owned automatic transfer switches (ATS) and two separate, semi-annual (every six months) generator preventive maintenance/load bank tests and inspections at Ann Arbor VA Medical Center, 2215 Fuller Road, Ann Arbor, MI 48105 and its Community-Based Outpatient Clinics (CBOCs) under a firm, fixed-price contract. SCOPE OF WORK Work performance visits: A coordinated first visit shall perform annual ATS inspections and maintenance A second visit for load bank testing and generator pm inspections A third visit to perform generator pm inspections and preventative maintenance procedures (oil, oil filter, air filter, fuel filter, belt replacement, and/or cooling flush/replace) Preventive maintenance procedures shall be in accordance with the published preventive maintenance manuals for the equipment listed in the schedule. Contractor shall utilize the Original Equipment Manufacturer s (OEM) established procedures and checklists, (or Contractor-supplied equivalent with approval from the Service POC/Contracting Officer s Representative (COR). A Field Service Report shall be supplied to the COR within 14 working days upon completion of each preventive maintenance visit/procedure. Preventive maintenance procedures shall include, but are not limited to: Cleaning of equipment (not housekeeping). Area must be left in a clean state after completion of work. All debris is the contractor s responsibility to discard. Completing OEM field service updates for operational and reliability engineering change notices. Perform annual testing in conformance with Manufactures, JCAHO, NFPA, and OSHA requirements. (load bank testing excluding 1500KW). Performing remedial maintenance of non-emergent nature. Provide test report on oil for each unit. Replace oil, replace oil filters, replace fuel filters, replace air filters, replace belts on fan units and radiators. Check for faulty and worn parts. Inspecting electrical wiring and cables for wear and fraying. Inspecting all mechanical components including but not limited to: cables and mounting hardware, pumps, seals, belts, interlocks, sensors, controls, bearings, hoses, heaters, radiators, and motors for operational integrity, safety and performance to OEM specifications. Returning the equipment to operating condition defined in OEM specifications. Contractor must ensure generators are returned to running order when work is completed (caps, valves, on/off switches, emergency stop buttons). Replacing any OEM labels, decals, or warning tags that are not legible. ATS: Inspect the visually accessible portions of the ATS for evidence of heat, water, and mechanical damage. After de-energizing upstream switchgear or placing the ATS in bypass mode, inspect the interior to verify that transfer switch mechanisms are intact together with their control circuit wiring, relays, and contacts. Inspect insulating parts, mechanism covers, and arc chutes for evidence of heat, discoloration and/or mechanical damage, and replace any that are excessively worn or damaged. Check the alignment, deflection, gap, and wiping action of the main and arcing contacts. Inspect main and arcing contacts for wear, pitting, erosion, and discoloration, which indicate arcing or heat-related deterioration. Inspect the transfer mechanisms, coils, and contacts for evidence of damage or malfunction. Check the tightness of all de-energized cable, wire, and bus connections, and re-secure any loose connections that are found. Record and verify all settings for voltage and frequency sensing, pickup, and dropout para-meters for both normal and emergency power, and settings for all timing functions. If the settings are inadvertently changed, then the recorded information will facilitate the recovery of normal operation. Replace eroded arcing contacts, if necessary. Adjust main and arcing contacts for simultaneous breaking in accordance with the OEM s procedure. Remove old lubricant residues, then lubricate the transfer switch mechanisms and their associated devices and linkages. Operate the ATS manually to verify proper function. Check for the proper settings for voltage and frequency sensing, pickup, and dropout features for both normal and emergency power, as well as settings for all timing functions. Clean the top, bottom, and doors of the ATS enclosure. If authorized and coordinated by the facility manager, test the re-energized ATS by switching from the normal source to the emergency source and back to verify proper function under load. Contractor shall notify the Contracting Officer of the existence or development of any defects in, or repairs to the equipment covered under this contract which the contractor considers he/she is not responsible for under the terms of the contract (such as operator misuse). All exceptions to the Preventive Maintenance Inspection schedule shall be arranged and approved in advance with the Contracting Officer. Emergency Repair Service: Service shall consist of maintaining the equipment in accordance with the Conformance Standards. Repair service shall consist of replacing parts, calibrating, cleaning, oiling, adjusting and maintaining the equipment except for services required due to accident, fire or abuse. The Service POC/COR shall have the authority to approve/request a service call from the Contractor. Service POC/COR name and contact details will be provided in the contract award email. Response Time: The Contractor s Field Service Engineer must respond with a phone call to the Contracting Officer Technical Representative within two (2) hours after receipt of notification in an effort to correct the problem by phone. If the problem cannot be corrected by phone, the Field Service Engineer shall commence work (on-site physical response) within four (4) hours after receipt of notification and shall proceed progressively to completion without undue delay. CBOCs Canton CBOC: 5900 N. Lotz Road, Canton, Michigan 48187 Jackson CBOC: 4328 Page Avenue, Jackson, Michigan 49254 LIST OF GENERATORS 750KW, Caterpillar, Mod#: 3508 Ser#: 9EN00523 (unit 1) 750KW, Caterpillar, Mod#: 3508 Ser#: 9EN00524 (unit 2) 750KW, Caterpillar, Mod#: 3508 Ser#: 9EN00526 (unit 3) 750KW, Caterpillar, Mod#: 3508 Ser#: 9EN00525 (unit 4) 750KW, Caterpillar, Mod#: 3508 Ser#: 9EN00528 (unit 5) 900KW, Detroit Diesel, Mod#: 900DS60 Ser#: 359177 500KW, Detroit Diesel, Mod#: 500DS6 Ser#: 360164 315KW, Caterpillar, Mod#: 3406 Ser#: 68A00792 1500KW, Caterpillar, Mod#:3512C Ser#: OSBG00962/G6T00105 (Unit 6) Canton, VD350-1 S/N: 126483-1-1 Jackson, Kohler 20KW, Mod#: 20RESD Ser#: SGV324W6K Boiler Plant, Kohler Mod#: KD2500 Ser#: N/A (New Install) LIST OF NON-GENERATOR EQUIPMENT Equipment List Service contract equipment to be covered by the Contractor. Equipment Designation Catalog Number Serial Number: E962340097XC 85650034 J7ATBA3600C5XC 640627 E7ATSC3260C5 240602 31ATS-1 E962380097XC 693531001 31ATS-2 E962380097XC 693531002 31ATS-3 E962315097XC 829499001 31ATS-4 F962380097XC 112341 32-ATS-1 E962340097XC 693531010 ATS E962326047XC 846919002-3 ATS 1-1 F962360097XC 856150011 ATS 1-2 F962360097XC 856150012 ATS 1-3 F962360097XC 856150013 ATS 3-1 E962340097XC 856150032 ATS 3-2 E962340097XC 856150035 ATS 3-3 E962340097XC 856150020 ATS 3-4 F962360097XC 119417-1 ATS 4- C2 E7ATBC3260N5XC 149785 ATS 4-A1 E7ATBC3260N5XC 149753 ATS 4-A2 E7ATBC3260N5XC 149756 ATS 4-B1 E7ATBC3260N5XC 149760 ATS 4-B2 E7ATBC3260N5XC 149763 ATS 4-B3 E7ATBC3400N5XC 149814 ATS 4-C1 E7ATBC3260N5XC 149765 ATS 4-C3 E7ATBC3400N5XC 149816 ATS 4-C4 E7ATBC3260N5XC 149789 ATS 4-C5 E7ATBC3260N5XC 149792 ATS 4-D1 E7ATBC3260N5XC 149794 ATS 4-D2 E7ATBC3260N5XC 149796 ATS 4-NEW 2 J7ATBA3260N5XC 514304 WE ATS 5-1 E962340097XC 856150027 ATS 5-2 E962326097XC 856150009 ATS 5-3 E962340097XC 856150033 ATS 5-4 E962340097XC 119415-2 ATS 5-5 F962360097XC 119417-2 ATS 5-6 E962326097XC 119418 ATS 5B/6B/7B/8B B940310097XC 919088001-1 ATS 7-1 E962340097XC 856150028 ATS 7-2 F962360097XC 856150021 ATS 7-3 E962340097XC 856150031 ATS 7-4 E962340097XC 856150034 ATS 7-5 F962360097XC 856150022 ATS B-1 E962340097XC 856150025 ATS B-2 E962340097XC 856150026 ATS B-3 E962340097XC 856150017 ATS B-4 E962340097XC 856150029 ATS B-5 E962340097XC 856150030 ATS B-6 E962340097XC 856150018 ATS B-7 E962340097XC 856150003 ATS B-8 E962340097XC 119415-1 ATS B-A1 E7ATBC3260N5XC 149801 ATS B-B1 E7ATBC3260N5XC 149806 ATS B-C1 E7ATBC3260N5XC 149812 ATS B-D1 E7ATBC3260N5XC 149813 ATS BI-1 E962340097XC 856150004 ATS-1E B940310097XC 919088001-2 ATS-3 E940326047C FP63767 ATS-B D7ATSC370C5 240601-001 RE ATS-C D7ATSC370C5 240601-003 RE ATS-D D7ATSC370C5 240601-002 RE ATS-LAB 94024033C 28857Y ATSM-1 E962340097XC 856150024 ATSM-6 E962360097XC 856150023 ATS-NEW 1 J7ATBA3400N5XC 514305 WE ATS-RB/RS/RP B940310097XC 919088001-3 ATS-SWBD#1 B940326049XC 883419 FIRE PUMP C940315091X FP94958-10 NURSING HOME J7ATBA3260N5XC 399336WE NURSING HOME J7ATBA3150C5XC 399335WE CONFORMANCE STANDARDS All services provided under this contract must be performed in conformance with OEM standards and specifications, the National Fire Protection Agency (NFPA) 70E, the Standard for Electrical Safety in the Workplace and IEEE 1584 - Guide for Performing Arc-Flash Hazard Calculations, as well as in the Occupational Safety and Health Administration (OSHA) CFR 1910 and 1926 workplace and construction safety regulations. These standards and regulations specify equipment and procedures for minimizing safety risks associated with accessing, testing, maintaining, and repairing transfer switches and power equipment. PARTS Contractor shall furnish all parts as necessary to maintain the equipment covered by this contract, in accordance with the Conformance Standards. Contractor stipulates that they have ready access to new OEM standard parts, or equal thereto. All parts supplied shall be of current manufacture and have full compatibility with existing equipment. Documentation of intended parts source(s) shall be provided to the Service POC/COR upon request. All materials related to maintenance will be covered under this service contract. Parts requiring repair outside of maintenance shall be priced separately, under a quote provided to the Service POC/COR and may not be replaced without approval (via contract modification) from the Contracting Officer. DOCUMENTATION/REPORTS The Contractor shall submit a legible field service report, test reports, which shall include detailed descriptions of the preventive maintenance, test inspection or emergency repair services performed, including replaced parts and estimated prices required for the service call. NOTE: There shall be no additional charges claimed for items and services that have not received approval, via an awarded contract modification from the Contracting Officer, prior to the item being supplied or the service being performed. CALIBRATION OF TESTING EQUIPMENT At Service POC/COR s request, Contractor shall provide a copy of the current Calibration Certification of all test equipment, which is to be used by the Contractor to perform services. Equipment calibration shall be traceable and in conformance with test equipment OEM standards. SAFETY REQUIREMENTS Contractor shall take all safety precautions as the Service POC/COR deems reasonably necessary to protect the lives and health of building occupants. The Service POC/COR shall notify the Contractor of any safety issues and the action necessary to correct them. Such notice, when served on Contractor or its staff at the work site, shall be deemed sufficient for the corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default. DAYS & HOURS OF OPERATION Normal business hours are defined as Monday through Friday, 7:00 am to 4:00 pm, excluding federal holidays or as otherwise arranged with the Service POC/COR. Work of an emergent nature, outside of normal working hours, at the request of the Contracting Officer or Service POC/COR shall be billed separately. Work outside of normal working hours, requested by the contractor, shall be included in the firm, fixed-prices already under contract. Federal holidays, and any days declared by the President of the United States to be a national holiday, can be found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/ CONTRACTOR STAFF COMPETENCY Contractor's staff shall include a "fully qualified" Field Service Representative assigned and a "fully qualified" Field Service Representative to serve as backup. Fully qualified" is based upon training and experience in the field. For training, the Field Service Representatives must have successfully completed a formalized training program for the types of equipment covered under this contract. For field experience, the Field Service Engineers must have a minimum of one (1) year of experience providing preventive maintenance and emergency repair services on the same types of equipment listed in this contract. The contractor shall provide written assurance of the staff competency by detailing a list of Field Service Representatives, applicable training, and number of years of service experience on the specific devices included in this SOW. This information shall be included in RFQ offer. CONTRACT STAFF REPORTING REQUIREMENTS Contractor is required to report to the Electric Shop to log in to work and log out of work during normal working hours. At service completion, the Contractor shall legibly document services rendered on a field service report. The field service report must be submitted the Service POC/COR for signature, during normal business hours. After hours, Contractor shall leave the field service report with the Boiler Plant operator.

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 562111
New
Federal
S205--General Waste & Recycling Removal Services - Detroit PoP 04/01/2032
Solicitation # 36C25027Q0022
The Department of Veterans Affairs Network Contracting Office 10 is soliciting quotes for a firm-fixed-price contract to provide general waste and recycling removal services for the John D. Dingell VA Medical Center and Fisher House 99 in Detroit, Michigan. This HUBZone Small Business set-aside procurement, under NAICS code 562111, covers the collection and disposal of non-hazardous municipal solid waste, corrugated cardboard, and construction or bulk waste. The scope specifically excludes regulated medical, hazardous, radioactive, pharmaceutical, and universal waste. The contractor is responsible for providing all labor, vehicles, and equipment, including 34-yard compactor containers and cardboard compactor systems, while responding to Real Time Continuous Monitoring System alerts. The contract features a base period from April 1, 2027, to March 31, 2028, with four subsequent option years extending the performance period through March 31, 2032. Award will be based on the best overall value to the government, with an evaluation focus on past performance. Successful offerors must be registered in the System for Award Management and maintain specific insurance coverages, including 500,000 dollars per occurrence for general liability and 200,000 dollars per person for automobile liability. Invoices must be submitted electronically via the Tungsten Network, and the contractor must adhere to strict quality control and weight verification standards using certified weighing systems.
Solid Waste Collection

POSTED

about 9 hours ago

DEADLINE

in 6 days
View Details
NAICS: 541380
New
Federal
J065--RO Equipment Maintenance
Solicitation # 36C25027Q0051
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed-price contract to provide preventive and non-routine emergency maintenance services for Reverse Osmosis (RO) equipment systems at the Ann Arbor VA Medical Center. The scope of work covers systems serving the Laboratory Department and Sterile Processing Service, requiring all labor, parts, and supervision to ensure uninterrupted process water operation in accordance with OEM, ST108, and AAMI standards. The anticipated period of performance begins January 8, 2027, and runs through January 7, 2032, consisting of a one-year base period and four one-year option periods. While originally designated as a small business set-aside, Amendment 0001 corrected the requirement to be 100% open market and unrestricted. Award will be based on the most advantageous offer, evaluating technical capability, past performance from the last three years, and total price including all options. Offerors must submit their quotes by November 16, 2026, including a signed SF 1449, a strict adherence to the price schedule, and a technical volume not exceeding ten pages. Contractor personnel are required to complete VA Privacy and Information Security Awareness training and provide all necessary licenses and certifications within three business days of award.
Testing Laboratories and Services

POSTED

about 9 hours ago

DEADLINE

in 19 days
View Details
NAICS: 541620
New
Federal
H941--Chemical Hoods & HEPA PM
Solicitation # 36C25027Q0065
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for the preventive maintenance, inspection, testing, and certification of chemical hoods and HEPA filters at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. This is a combined service contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), requiring that no more than 50 percent of the contract value be paid to firms not listed as SDVOSBs or VOSBs. The scope of work includes recurring semiannual and annual certifications, environmental monitoring, and optional condition-based HEPA filter replacements across pharmacy, research, and engineering systems. Performance is scheduled for normal business hours, though off-hours work may be required to avoid disrupting patient care. The contract utilizes a firm-fixed-price structure for both recurring services and optional line items, such as BSC decontamination and ASHRAE 110 tracer-gas testing. A mandatory site visit was scheduled for November 3, 2026, and quotes were due by November 10, 2026. Award evaluation is based on technical rating, price, and past performance. Successful contractors must submit a Quality Control Plan within 10 business days of award and a reconciled electronic inventory within 30 calendar days. All work must adhere to strict regulatory standards, including VHA Directive 1108.12 and USP 797 and 800, with detailed reporting required for acceptance, including raw measurements and unambiguous certification status.
Environmental Consulting Services

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 334510
New
Federal
Q403--WatchPat One Direct Program Roudebush VA Medical Center Indianapolis, IN
Solicitation # 36C25027Q0071
The Department of Veterans Affairs, specifically the Richard L. Roudebush Veterans Administration Medical Center in Indianapolis, Indiana, has issued a Notice of Intent to Sole Source for the continuation of the WatchPat One Direct Program. Under solicitation number 36C25027Q0071 and NAICS code 334510, the government intends to negotiate a firm fixed price contract with Veterans Healthcare Supply Solutions (VHSS) based in Jacksonville, Florida. This requirement is being pursued under Simplified Acquisition Procedures and the authority of FAR Part 6.103-1, as the government believes VHSS is the only source capable of meeting the specific needs of the Sleep Lab Department. The scope of work involves providing WatchPat devices that are delivered directly to Veterans' homes for sleep monitoring, with the resulting sleep study reports delivered to clinicians via cloud access. This notice is not a formal solicitation or request for proposals; however, interested parties may submit responses until 3:00 pm on October 29, 2026. To challenge the sole source intent, responses must provide clear and convincing evidence that competition would be advantageous to the government. The primary point of contact for this action is Contract Specialist Ghazal Jones.
Electromedical and Electrotherapeutic Apparatus Manufacturing

POSTED

2 days ago

DEADLINE

in about 22 hours
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS