Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 20, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J063--MVAHCS Fire Alarm Maintenance Sources Sought

Closed
36C26326Q1047Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561621
New
Centennial Fire Alarm & CO Detection Upgrade and Maintenance Services
Solicitation # centennial-fire-alarm-co-detection-upgrade-maintenance-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide fire alarm and carbon monoxide (CO) detection upgrade and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The primary objective is to restore the central Simplex 4020 Fire Alarm Control Center Panel and connected systems across nine campus facilities to full operational status. The scope of work includes diagnosing and clearing system troubles, upgrading the panel motherboard or firmware if necessary, and integrating CO detection into the men's and women's dormitories by installing intelligent multi-criteria detectors and sounder bases. All work must adhere to NFPA 101 (2024), NFPA 72 (2025), IFC (2024), and local building and fire codes. Bids are due by December 1, 2026, and must be submitted via email to Sandra Clore. A mandatory physical site visit is required prior to bid submission. Proposals must include a detailed cost breakout of materials, labor, equipment, and fees, as well as proof of insurance and warranty information. For bids equal to or exceeding $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety company. This project is subject to the Davis-Bacon Act and Construction Wage Rate Requirements, necessitating the submission of weekly certified payroll reports for payment processing. The solicitation is open to small businesses, including certified VOSB, SDVOSB, WOSB, and HUBZone entities. Award decisions will be based on overall best value. Required documentation for award and final payment includes a Unique Entity ID (UEI), a completed W-9, and various certifications such as the SF 1413 Statement and Acknowledgement. Final acceptance is contingent upon a successful on-site inspection, the delivery of operation and maintenance manuals, and the submission of a digital asset report for integration into the facility's Computerized Maintenance Management System.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 8 hours ago

DEADLINE

in 19 days
NAICS: 561621
New
International
Conwy County Leisure Facilities CCTV Supply and Install
Solicitation # CCTV-LS-2026-01
Conwy County Borough Council is seeking a qualified contractor for the supply, installation, commissioning, configuration, and three-year maintenance of CCTV systems across seven leisure facilities. This project, identified by solicitation number CCTV-LS-2026-01, aims to enhance security, safeguarding, and operational resilience. The successful provider must deliver a modern, integrated solution featuring high-quality surveillance and evidential recording capabilities, with full integration into the Conwy Alarm Receiving Centre. The estimated contract value is 100,000 GBP excluding VAT, with a performance period running from January 1, 2027, to March 31, 2030. The procurement process is an open competition particularly suited for small and medium-sized enterprises, with award criteria split equally between price and quality. Bidders must submit their proposals via the sell2wales portal by November 26, 2026. A critical component of the evaluation is a financial due diligence assessment where applicants must achieve a low or medium risk score to pass. This assessment evaluates profitability over the last two financial years, positive net assets, and a current ratio of 0.8 or higher. Failure to meet these financial thresholds without a compelling reason or a refusal to provide a requested guarantee may result in disqualification.
Conwy County Borough Council

POSTED

about 14 hours ago

DEADLINE

in 13 days
NAICS: 561621
New
Federal
H312--Fire Alarm Maintenance Service Contract FY27 - NEW Base + Four - 583
Solicitation # 36C25027Q0009
Solicitation 36C25027Q0009 is a request for proposals from the Department of Veterans Affairs Network Contracting Office 10 for a fire alarm maintenance service contract at the Richard L. Roudebush VAMC in Indianapolis, Indiana, including the main hospital, campus out-buildings, and the Cold Springs Road remote site. This contract is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The scope of work requires the contractor to provide inspection, testing, maintenance, and minor repairs for both electrical and mechanical components of fire alarm and suppression systems. The contract structure consists of a base year and four option years, with award based on price alone. Technical requirements mandate compliance with NFPA 72-2025, NFPA 25-2026, and Joint Commission standards. Key tasks include quarterly flow tests for the electric fire pump, while monthly no-flow tests are performed in-house by VA personnel. Personnel qualifications include a preference for NICET 3 certification, though NICET Level II may be accepted for certain inspections. Offerors must provide a mandatory Certificate of Compliance regarding limitations on subcontracting, ensuring no more than 50 percent of the work is performed by non-SDVOSB firms. All work must be conducted in accordance with strict VA cybersecurity and personnel vetting protocols, particularly given the critical nature of operating within an occupied healthcare facility.
250-NETWORK Contract Office 10 (36C250)

POSTED

about 19 hours ago

DEADLINE

in 3 days
NAICS: 561621
New
Federal
USCG Station Wachapreague Alarm Monitoring Service
Solicitation # 3030127RFQ000001
The Department of Homeland Security, through Base Portsmouth, is soliciting quotes for a firm-fixed price contract to provide continuous 24/7 security alarm monitoring services for the Armory at Coast Guard Station Wachapreague in Virginia. This procurement is a total small business set-aside under NAICS code 561621. The contractor is responsible for providing all labor, materials, and equipment to monitor a DMP IDS solution or approved equivalent via secure cellular or IP transmission to a UL-listed central monitoring station. Key requirements include immediate notification of designated points of contact for alarms or system faults, coordination with Accomack Police when necessary, and the provision of monthly activity and health reports. The contract is structured with a base year starting December 14, 2026, and four subsequent annual option years, not to exceed a total duration of five years. Award will be made to the responsible offeror with the lowest price technically acceptable quote, based on a technical approach that demonstrates the ability to meet all Statement of Work requirements. Quotes must be submitted via SF-18 by 5:00 PM Eastern Time on November 30, 2026. Interested parties are encouraged to attend a site visit on November 23, 2026. Compliance with the Service Contract Act, OSHA safety regulations, and specific insurance requirements for worker's compensation, general liability, and automobile liability is mandatory.
Base Portsmouth

POSTED

about 19 hours ago

DEADLINE

in 18 days
NAICS: 561621
New
Federal
W9124G26CBARRACKS
Solicitation # 052917
The Department of Defense, through the Mission and Installation Contracting Command at Fort Rucker, Alabama, is soliciting quotes for a firm-fixed price contract to integrate, configure, and maintain closed-circuit television surveillance systems across four barracks facilities, specifically Buildings 8350, 8354, 8355, and 8356. The scope of work requires the contractor to centralize video streams from three buildings into a monitoring station in Building 8350 during the base year, providing all necessary cabling and network hardware. Following integration, the contractor will perform semi-annual preventative maintenance inspections based on a 12-point checklist. The contract is structured with a 12-month base year and four subsequent one-year option years, with a total performance period of five years. This procurement is a 100 percent total small business set-aside under NAICS code 561621. Award will be based on the Lowest Price Technically Acceptable (LPTA) method, evaluating technical capability on a pass/fail basis across four sub-factors: system integration approach, maintenance planning, response time capabilities, and administrative compliance. Key requirements include a one-year warranty on new parts and labor, a 3,000 dollar not-to-exceed limit for replacement parts per period of performance, and strict emergency response times, including a one-hour telephone response and four-hour on-site arrival for critical failures. All quotes must be submitted electronically to the contracting office by the revised deadline of December 18, 2026, at 12:00 PM CST.
W6QM Micc-Ft Rucker

POSTED

about 19 hours ago

DEADLINE

in about 1 month
NAICS: 561621
New
Federal
Lenel OnGuard system with LenelS2 physical security solutions
Solicitation # 1301398064-1
The Naval Surface Warfare Center Carderock Division (NSWCCD) is soliciting a brand name, firm fixed price purchase order for a Lenel OnGuard system with LenelS2 physical security solutions. This acquisition is conducted under Simplified Acquisition Procedures and is restricted to authorized Lenel distributors or resellers. The scope of work is limited to software and programming, specifically upgrading the existing system from OnGuard 32ES (v7.6.382.52) to OnGuard Enterprise 8.3 Update 1 or the latest supported version. Key deliverables include providing and programming database segmentation licensing for a specific area at the Acoustic Research Detachment (ARD), ensuring administration for that room is accessible only through a designated computer. The contract is designated as FOB destination and is unclassified, though it carries strict personnel requirements. All contractors must be US citizens and pass a background check to gain base access, which prohibits individuals with felony convictions less than ten years old, registered sex offenders, or those on terrorist watch lists. Evaluation will be based on a pass/fail technical review of the Performance Work Statement, followed by an assessment of past performance and price reasonableness. The most advantageous offer from a technically acceptable and responsible quoter will be selected. Quote packages, including the company name, point of contact, authorized reseller certification, lead time, manufacturer specifications, and Cage Code, must be submitted to the primary point of contact by November 20, 2026.
Navsea Warfare Center

POSTED

about 19 hours ago

DEADLINE

in 7 days
NAICS: 561621
New
Federal
CTX Life Safety Assessment and Fire Damper Inspection
Solicitation # 36C25727Q0050
The Department of Veterans Affairs, Network Contracting Office 17, is soliciting quotes for a firm-fixed-price contract to provide life safety assessment services and fire damper inspection, testing, repair, and reporting for the Central Texas Veterans Health Care System. The scope of work covers both the Temple and Waco campuses and requires a certified Fire Protection Engineer to conduct assessments and provide Statement of Condition documentation. Specific tasks include the testing, labeling, and repair of fire dampers across numerous identified buildings at both locations, with a requirement that repairs at the Temple and Waco campuses be performed simultaneously. All work must adhere to NFPA codes, Joint Commission standards, and VA Infection Control Risk Assessment requirements. This acquisition is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 561621. The period of performance is 180 days from the notice to proceed. Award will be based on a competitive best value selection using comparative analysis, evaluating factors such as engineer qualifications, technical approach, compliance plans, staffing, project management, price, and past performance. Key deliverables include CAD drawings, hard-copy drawing sets, and weekly deficiency reports. Invoicing must be submitted electronically via the Tungsten Network in arrears upon government acceptance. No bid, performance, or payment bonds are required for this solicitation.
257-NETWORK Contract Office 17 (36C257)

POSTED

about 19 hours ago

DEADLINE

in 10 days

AI Contract Overview

Show more

The Minneapolis VA Healthcare System has issued a sources sought notice for market research regarding fire alarm system inspection, maintenance, and repair services. This requirement involves providing comprehensive services to ensure the facility's fire alarm systems remain in compliance with NFPA 72 standards. Key responsibilities include annual inspections of the entire system, semi-annual testing of smoke detectors and battery chargers in the Community Living Center, 24/7 system monitoring, and emergency callback services with a four-hour response time for emergencies. The contractor will be responsible for all labor, tools, materials, and software/firmware updates, as well as the maintenance of wiring and circuitry. The scope of work covers multiple buildings within the Minneapolis VA campus, including complex systems such as the Gamewell/FCI E3 addressable fire alarm system and various emergency voice communication systems. Qualified vendors must provide technicians with specific NICET certifications, including Level II and Level III, with at least one technician trained specifically for Gamewell/FCI E3 systems. Interested vendors must submit their organization's socio-economic category, information regarding existing government contract capabilities, and subcontracting plans via email to the designated point of contact by August 26, 2026. This notice is for market research purposes only, and no contract awards will be made through this specific announcement.

General Info

Minneapolis VA seeks fire alarm inspection, maintenance, monitoring, and emergency repair services.

NAICS

561621 - Security Systems Services (except Locksmiths)

Place of Performance

Minneapolis VA Health Care System, Minneapolis, MN, 55417, USA

Set-Aside

NONE

Documents

1
DOCX, Low priority10 pages · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts1 person available
OfficeSaint Paul, MN, 55101, USA

Full Description

Show more
The Minneapolis VA Healthcare System requires fire alarm system inspection, maintenance and repair services in accordance with the draft Statement of Work (SOW) below. This is a sources sought looking for vendors to perform the services per the SOW for market research purposes. No awards of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your contact and organization information with a descriptive proof of capability to: Sign up to see this detail on or before August 26th, 2026. Only emailed responses will be considered. Additionally, please provide answers as appropriate to the following questions in the table below with your response to this sources sought. Failure to respond to the following questions may affect the acquisition strategy. Question # Questions Vendor Responses 1. Identify your organization's socio-economic category.   2. State whether any of the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.).   3. State if subcontracting is contemplated for this requirement, what percentage of the work will be subcontracted and for what tasks.     *If applicable, VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses or Service Disabled Veteran Owned Small-Businesses.* *If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses.* Draft Statement of Work Minneapolis VA Health Care System Fire Alarm Testing, Inspection, Maintenance, and Repairs
I. SCHEDULE OF SUPPLIES: A. Fire Alarm System Maintenance Services Contracted fire alarm services shall perform all inspections, testing, maintenance, and repairs of the facility fire alarm necessary to keep the Minneapolis VAHCS fire alarm system in compliance with the most current edition of NFPA 72: National Fire Alarm and Signaling Code. The Contractor shall provide tools, materials and labor necessary to properly perform services on this contract. Contractor shall inspect the entire fire alarm system annually. All battery chargers and the smoke detectors located in the Community Living Center will be inspected and tested on a semi-annually basis. Contractor shall include Emergency Callback Services for normal and off-hours repair of the fire alarm system and/or components. Contractor shall respond to emergencies within 4 hours and 8 hours for non-emergency calls. Contracted fire alarm services shall provide twenty-four hours per day, seven days per week monitoring of the Minneapolis VAHCS alarm system. The Contractor shall provide all parts and materials necessary to effect maintenance and repairs of the fire alarm system. During the term of the contract, the VA may replace, renovate, or improve systems and equipment by means not associated with this contract. All replaced, improved, updated, modernized, or renovated systems and equipment shall be maintained and/or repaired by the Contractor at no additional cost to the VA unless there is a resulting increase or decrease in contract requirements. Buildings are protected by a Gamewell/FCI (Fire Control Instruments) E3 addressable fire alarm system with a Network Graphic Annunciator (NGA) LCD touch screen that serves as the primary interface with the control panel in room 1T-108. Remote NGAs are located near the Employee Entrance and in the VA Police Office. The Contractor shall be responsible for providing inspection, maintenance and repair of the fire alarm systems wiring and circuitry during the inspection, maintenance and repair of the fire alarm systems themselves. The cost of this work shall be included in the cost of the servicing of the individual systems. The Contractor shall ensure that all software/firmware of the fire alarm systems are up to date to the most current version during inspection and testing and complete all software/firmware updates as necessary to bring them up to date. Inspection, testing, maintenance and repairs of the fire alarm system shall be performed between September 1st and December 31st, to be consistent with the completion of previous year testing timeframes. The CLC fire alarm system shall also be inspected, tested, maintained and repaired between April 1st and April 30th. Contractor is responsible for scheduling and associated costs for elevator technicians to assist with the servicing of the fire alarm system(s) associated with elevators.
II. GENERAL INFORMATION: A. Safety Procedures The contractor shall comply with all VA and OSHA safety code requirements. B. Hazardous Conditions If the inspector encounters equipment that is in a condition that may endanger the life or property, the inspector shall immediately notify the Engineering Department POC of the condition requiring immediate action. Within 24 hours the inspector shall provide a written report to the COR or Site Safety Officer of the hazardous condition and recommended corrective action. D. Employee Number and Qualifications - The Contractor shall provide a minimum of 2 Certification in Engineering Technologies (NICET) Level II (minimum) certified technicians and one service manager with NICET level III to perform services under this contract. At least one of the technicians will be trained and certified to service/program Gamewell/FCI E3 fire alarm systems. Contractor employee certifications shall be provided upon request to VA officials. E. The Contractor shall not interrupt or interfere with the operation of any existing activity on the premises or at the location of the work. F. The Contractor shall clean up, all refuse, rubbish, scrap materials and debris caused by its operation, to the extent that at all times the site of the work shall present a neat, orderly and workmanlike appearance. G. Contractor employees shall present a professional appearance at all times and their conduct shall not reflect discredit upon the United States and or the VA/VHA. H. Employees shall not disturb desks or any administrative spaces. Employee will not use VA/VHA telephones, copiers, or any other office equipment intended for official Medical Center use. Employees will not disturb drawers, cabinets, or other storage areas. III. DESCRIPTION/SPECIFICATIONS: A. Notification 1. Contractor shall provide a minimum of two weeks-notice to the Site Safety Officer before proceeding with services and then a notice at two days prior and after the testing. B. Inspection and Testing Requirements 1. Inspection and Testing frequencies from the most current edition of NFPA 72: National Fire Alarm and Signaling Code. 2. Contractor shall provide an implementation plan that details how all the Inspections and Testing of equipment will be conducted. 3. During the inspection and testing process, conduct a review of the software and firmware being used by the MVAHCS. Contractor shall provide recommendations to the VA regarding the costs vs. benefits of upgrading software and firmware to newer versions. 5. Identify potentially detrimental site conditions that could compromise the performance of mechanical and/or electronic components of the fire alarm system. 6. Inquire about any changes or modifications of the fire alarm system. 7. Inquire about changes in the general occupancy environment, operations and conditions relating to the fire alarm system. 10. Compile a complete report of the Inspection and Testing, explaining any deficiencies and corrective action taken in accordance with recognized codes for care and maintenance. 12. Contractor shall work with the VA on periodic programming of messages into the Voice Alarm Channels. D. Maintenance and Repair of Fire Detection and Alarm System Contractor shall provide preventative maintenance services on the fire alarm systems at the MVAHCS. The contractor shall provide Emergency Callback Services (ECS): ECS consists of responding to a service call and beginning to take corrective action within four (4) hours. ECS shall be provided twenty-four (24) hours a day, seven (7) days a week. Service Tickets: Contractor shall have service ticket on each service call signed by the MVAHCS designated representative. Service ticket shall describe the work performed and provide the date and time of service. Contractor personnel shall check in and out with an MVAHCS representative when arriving and leaving the site check via email or phone call. Any incomplete work shall be reported to an MVAHCS representative prior to leaving MVAHCS property. Equipment malfunctions shall be corrected within at least two days, or longer upon MVAHCS approval. F. Inspection, Testing, Maintenance, and Repair Records After completing regular inspection, testing, and maintenance, the Contractor shall furnish written list of deficiencies in the fire alarm system to the COR or Site Safety Officer within two (2) business days. Within 14 calendar days of the inspection, testing, and maintenance, the Contractor shall provide a formal written report to the COR and Site Safety Officer that includes the following (1 hard copy and 1 electronic copy): Contractor s Inspection and Testing Form that includes all the information required by the most current edition of NFPA 72, Chapter 7: National Fire Alarm and Signaling Code. A record of the completed inspection, maintenance and/or repair items. The record shall include any problems noted with the system, including inoperable or unsupervised devices or equipment, or devices that cannot be calibrated, tested, serviced in accordance with the manufacturer s recommendations. Reports shall include the software and firmware version, system address, physical location, device description, operational status and condition of the device. Reports shall include all fire alarm system deficiencies found and suggested corrective action. Maintenance log report summarizing preventive and non-preventive maintenance performed on equipment covered by this contract. The Contractor must be able to properly troubleshoot and diagnose all aspects of fire alarm system failures. When fire alarm systems fail completely (i.e. irreparable system failure), the technician s Supervisor shall provide the MVAHCS with a written statement and itemized quote assessing the fire alarm system failure and that they have verified the fire alarm system has been properly diagnosed and concur with the technician s assessment. The VA reserves the right to enlist a third-party expert to provide a 2nd opinion. It is the responsibility of the Contractor to reassess their proposed repairs and either reaffirm or correct their proposal based on the expert s notes. The reassessment shall include at a minimum, a substantive analysis of the third-party expert s points that contradict the Contractor s original conclusion. This reassessment shall be submitted within 5 business days of receipt of the third-party expert s opinion. The Contractor shall furnish testing to the following auxiliary Fire Alarm devices and systems which communicates/signals the main Fire Alarm System in Bldg. 70: Data Center Suppression System 2B105. Fire Alarm Roll Down Doors in Outpatient Pharmacy (1R-101), SCI Pharmacy (SC, & Uniform Issue (1N-104). Dust collector V. QUALITY CONTROL: The contractor shall develop and maintain an effective quality control program to ensure services are performed in accordance with this SOW. The quality control program plan shall be supplied to an MVAHCS representative upon request. IX. RECOGNIZED HOLIDAYS: A. Unless contacted for an ESC, the contractor is not required to perform services on the following holidays: 1. New Year s Day 2. Martin Luther King Jr. s Birthday 3. President s Day 4. Memorial Day 5. Juneteenth 6. Independence Day 7. Labor Day 8. Columbus Day 9. Veteran s Day 10. Thanksgiving Day 11. Christmas Day X. HOURS OF OPERATION: A. The contractor shall coordinate with the COR, ATS Shop and Site Safety Officer to determine when inspection, testing, maintenance or repair can be performed. E. Normal business hours, when regular Contractor service shall be available to the government, are Monday through Friday, from 7:30 am to 4:00 pm, federal holidays excluded. C. When inspection, testing, maintenance, or repair will interfere with building operations; it shall be performed after normal business hours.
XII. SECURITY REQUIREMENTS: Contractor staff are required to conform to MVAHCS s security and privacy requirements as described below. The following security language is applicable to Contractor staff who will enter MVAHCS facilities. Contractor staff will utilize a temporary vendor s security badge until a permanent security PIV badge can be issued. Temporary badge use will not exceed 30 calendar days. The Contractor shall comply with MVAHCS security, access, and badging requirements. Employees must provide fingerprints and be able to pass a background check so they can obtain a security access badge. All Contractor staff will need a valid individual personal or professional email account that can be easily checked. Notifications regarding fingerprint scheduling/appointments, background investigation tasks, and Training Management System (TMS) required classes will be sent to their email address throughout the badging process. Appropriate vendor staff (as determined by the VA) performing the duties of the Statement of Work shall complete the computer-based training course TMS 10176 Infosec/Rules of Behavior . Contractor staff shall be escorted while on VHA property. The Contractor will submit all required security badging documents for each employee within five (5) business days from the award date of contract. All documents must be legible. The following documents will be sent to the Contractor via email after contract is awarded.   OF 306 Must be Typed. Submission of handwritten forms will not be acceptable. Self-Certification VA 10-2417 Employee Fingerprint Resource Form XV. BUILDING DESCRIPTIONS: Building 9: Approximately 30,000 ft2, multistory building. Building is fully sprinkled (dry sprinkler system) and has a single elevator. Fire alarm system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 10: Approximately 25,000 ft2, multistory building. Building is fully sprinkled (dry sprinkler system) and has a single elevator. Fire alarm system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 47: Approximately 3,600 ft2, multistory building. Building is fully sprinkled. Fire alarm system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 49/49A: Approximately 75,000 ft2, multistory building. Building is fully sprinkled and has 2 elevator banks. Fire alarm system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 68: Approximately 30,000 ft2, multistory building. Building is fully sprinkled and has a single elevator. Fire alarm system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 69: Approximately 30,000 ft2, multistory building. Building is fully sprinkled. Fire alarm system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 70: Approximately 1,200,000 ft2, multistory building is fully sprinkled, has smoke control zones, multi-elevator banks, door controllers, kitchen interconnections, and dry pipe systems. Fire alarm system is networked with the Fire Alarm Network System located within the building, but has a separate DACT for standalone operation. Building 72: Approximately 10,000 ft2, single story building. Building is fully sprinkled and has a gas detection system. The new system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 73: Approximately 5,000 ft2, single story building. Building is fully sprinkled. The new system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 74: Approximately 5,000 ft2, single story building. Building is fully sprinkled. The new system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 75: Fisher House II is approximately 14,606 ft2, two-story building. Building is fully sprinkled. The new system has its own DACT for standalone operation with dial-up operation to St. Paul Fire. Building 76: Spinal Cord Injury/Disorder Center is approximately 62,000 ft2, two-story building (including basement). Building is fully sprinkled. The new system has its own DACT for standalone operation with dial-up operation to St. Paul Fire. Building 78: Parking ramp elevator areas only. Fire alarm system is networked with the Fire Alarm Network System located in Building 70. Building 79: Approximately 13,550 ft2. Building 80: Approximately 15,550 ft2. Building 89: Business office space. Fire alarm system is networked with the Fire Alarm Network System located in Building 70. Building 222: Approximately 62,000 ft2, multi-story building. Building is fully sprinkled. The new system shall be networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Building 224: Approximately 13,500 ft2, single story building. Building is not sprinkled. The new system is networked with the Fire Alarm Network System located in Building 70, but has its own DACT for standalone operation. Appendix A Description of Existing System A. Fire-alarm signal initiation occurs by one or more of the following devices and systems: 1. Manual stations. 2 Heat detectors. 3. Smoke detectors. 4. Duct smoke detectors. 5. Verified automatic alarm operation of smoke detectors. 6. Automatic sprinkler system water flow. 7. Heat detectors in elevator shaft and pit. 8. Fire-extinguishing system operation. 9. Fire standpipe system. 10. Line loss. 11. Generator start-up. 12. FACP circuit trouble. 13. 1 degree and 2 degree power loss. 14. Dry Air System B. Fire-alarm signal initiates the following actions: 1. Activates voice/alarm communication system. 2. Identifies alarm at fire-alarm control unit and remote annunciators. 3. Transmits an alarm signal to the remote alarm receiving station. 4. Unlocks electric door locks in designated egress paths. 5. Releases fire and smoke doors held open by magnetic door holders. 6. Recalls elevators to primary or alternate recall floors. Activates elevator bank shunt trip. 7. Records events in the system memory. 8. Records events by the system printer. C. Supervisory signal initiation is caused by one or more of the following devices: 1. Valve supervisory switches (Sprinkler, Standpipe Control, PIV, Main Gate). Operation of valve shall sound a supervisory signal at the Main Control Unit until silenced by manual off switch. 2. Low-air-pressure switch of a dry-pipe sprinkler system. 3. Elevator shunt-trip supervision. D. System trouble signal initiation is caused by one or more of the following devices and actions: 1. Open circuits, shorts, and grounds in designated circuits. 2. Opening, tampering with, or removing alarm-initiating and supervisory signal-initiating devices. 3. Loss of primary power at fire-alarm control unit. 4. Ground or a single break in fire-alarm control unit internal circuits. 5. Abnormal ac voltage at fire-alarm control unit. 6. Break in standby battery circuitry. 7. Failure of battery charging. 8. Abnormal position of any switch at fire-alarm control unit or annunciator. 9. Fire-pump power failure, including a dead-phase or phase-reversal condition. 10. Low-air-pressure switch operation on a dry-pipe or pre-action sprinkler system. E. System Trouble and Supervisory Signal Actions: 1. Annunciates at fire-alarm control unit and remote annunciators. 2. Records the event on system printer. 3. Arranges trouble signals for automatic reset (non-latching). 4. Alarm signals from smoke detectors at pressurization air supplies have a higher priority than other alarm signals that start the system. F. Smoke-Alarm Verification: 1. Initiates audible and visible indication of an "alarm-verification" signal at fire-alarm control unit. 2. Activates an NRTL-listed and -approved "alarm-verification" sequence at fire-alarm control unit and detector. 3. Records events by the system printer. 4. Sounds general alarm if the alarm is verified. 5. Cancels fire-alarm control unit indication and system reset if the alarm is not verified. G. Elevator Recall: 1. Smoke detectors at the following locations initiate automatic elevator recall. a. Elevator lobby detectors except the lobby detector on the designated floor. b. Smoke/Heat detector(s) in elevator machine room. 2. Elevator lobby detectors located on the designated recall floors are programmed to move the cars to the alternate recall floor. 3. Water-flow alarm connected to sprinkler in an elevator shaft and elevator machine room shut down elevators associated with the location without time delay. 4. Water-flow switch associated with the sprinkler in the elevator pit may have a delay to allow elevators to move to the designated floor. H. Door Controls: Door hold-open devices that are controlled by smoke detectors at doors in smoke barrier walls are connected to fire-alarm system. I. Remote Smoke-Detector Sensitivity Adjustment: Controls select specific addressable smoke detectors for adjustment, displays their current status and sensitivity settings, and changes those settings. Allows controls to be used to program repetitive, time-scheduled, and automated changes in sensitivity of specific detector groups. Records sensitivity adjustments and sensitivity-adjustment schedule changes in system memory and print out the final adjusted values on system printer. J. Remote Control Capability: Each building fire alarm control unit is installed and programmed so that each must be reset locally after an alarm, before the main fire alarm control unit can be reset. After the local building fire alarm control unit has been reset, then the system acknowledge, reset, silence or disabling functions can be operated by the main fire alarm control unit. K. General: 1. An emergency voice communication system is installed throughout Building 49, 49A, 70, 76, 79 and 80. 2. Upon receipt of an alarm signal from the building fire alarm system, the VCS automatically transmits a pre-recorded fire alarm message throughout the floor in alarm, the floor above, and the floor below. 3. A digitized voice module is used to store each prerecorded message. 4. The VCS is arranged as a dual channel system capable of transmitting two different messages simultaneously. 5. The VCS supervises all speaker circuits, control equipment, remote audio control equipment, and amplifiers. L. Speaker Circuit Control Unit: 1. The speaker circuit control unit includes switches to manually activate or deactivate speaker circuits grouped by floor in the system. 2. Speaker circuit control switches provide on, off, and automatic positions and indications. 3. The speaker circuit control unit includes visual indication of active or trouble status for each group of speaker circuits in the system. 4. A trouble indication is provided if a speaker circuit group is disabled. 5. A lamp test switch is provided to test all indicator lamps. 6. A single "all call" switch is provided to activate all speaker circuit groups simultaneously. 7. A push-to-talk microphone is provided for manual voice messages. 8. Remote microphones are provided at the Outpatient Entrance Manned Station (Building 70, near room C1-183) for manual "all call" messages. 9. A voice message disconnect switch is provided to disconnect automatic digitized voice messages from the system. The system is arranged to allow manual voice messages and indicate a system trouble condition when activated. M. Speaker Circuit Arrangement: 1. Speaker circuits are arranged such that there is one speaker circuit per smoke zone. 2. Audio amplifiers and control equipment are electrically supervised for normal and abnormal conditions. 3. Speaker circuits are either 25 VRMS or 70.7 VRMS with a minimum of 50% spare power available. 4. Speaker circuits and control equipment are arranged such that loss of any one speaker circuit will not cause the loss of any other speaker circuit in the system. N. Digitized Voice Module (DVM): 1. The Digitized Voice Module provides prerecorded digitized evacuation and instructional messages. The messages shall be professionally recorded and approved by the COTR prior to programming. 2. The DVM is configured to automatically output to the desired circuits following a 10-second slow whoop alert tone. 3. The DVM is supervised for operational status. 4. Failure of the DVM will result in the transmission of a constant alarm tone. O. Audio Amplifiers 1. Audio Amplifiers provide a minimum of 50 Watts at either 25 or 70.7 VRMS output voltage levels. 2. Amplifiers are continuously supervised for operational status. 3. Amplifiers are configured for either single or dual channel application. P. Tone Generator(s): 1. Tone Generator(s) are capable of providing a distinctive three-pulse temporal pattern fire alarm signal as well as a slow whoop. 2. Tone Generator(s) are continuously supervised for operational status. Q. Notification Appliances: Individually addressed, connected to a signaling line circuit, equipped for mounting as indicated and with screw terminals for system connections. R. Addressable Interface Devices: 1. Microelectronic monitor modules, NRTL listed for use in providing a system address for alarm-initiating devices for wired applications with normally open contacts. 2. Have unique addresses that report directly to the building fire alarm panel. 3. Monitors normally open or normally closed devices for both alarm and trouble conditions. 4. Terminal designations differentiate between the circuit to which they are reporting from and the device that they are monitoring. S. Smoke Barrier Door Control: 1. Door holder control circuits are electrically supervised. 2. Smoke detectors are not an integral part of door holders. Each door holder has two (2) adjacent smoke detectors. T. Digital Alarm Communicator Transmitter 1. Digital alarm communicator transmitter shall be acceptable to the remote central station and shall comply with UL 632 and be listed and labeled by an NRTL. 2. Unit receives an alarm, supervisory, or trouble signal from fire-alarm control unit. It automatically captures two telephone line(s) and dials a preset number for a remote central station. When contact is made with central station(s), signals are transmitted. If service on either line is interrupted for longer than 45 seconds, transmitter initiates a local trouble signal and transmits the signal indicating loss of telephone line to the remote alarm receiving station over the remaining line. Transmitter automatically reports telephone service restoration to the central station. If service is lost on both telephone lines, transmitter initiates the local trouble signal. 3. DACT has an integral rechargeable battery and automatic charger. 4. DACT conducts a self-test automatically every 24 hours with report transmitted to central station.

More opportunities from Department Of Veterans Affairs → Network Contract Office 23 (36C263)

Same awarding agency

NAICS: 236220
New
Federal
PN: 438-21-403, Renovate First Floor Kitchen (SF)
Solicitation # 36C26326B0020
Solicitation 36C26326B0020 is a Firm-Fixed-Price contract issued by the Department of Veterans Affairs, Network Contracting Office 23, for the renovation of the first floor kitchen in Building 5 at the Sioux Falls VA Medical Center in South Dakota. This project, identified as PN 438-21-403, is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. The estimated construction magnitude is between $10 million and $20 million, with a performance period of 550 calendar days from the Notice to Proceed. The scope of work encompasses comprehensive demolition, site work, and architectural, structural, mechanical, and electrical improvements, including the installation of owner-furnished equipment. Key operational requirements include phased construction to ensure the existing second-floor kitchen remains functional for inpatient meals. Contractors must adhere to strict safety and health protocols, including VHA Pre-Construction Risk Assessments (PCRA) and Infection Control Risk Assessments (ICRA), as well as OSHA and ADA standards. The award will be made to the responsible bidder offering the most advantageous price. Bidders must provide a bid guarantee of at least 20 percent of the bid price, capped at $3 million, and submit performance and payment bonds totaling 100 percent of the contract amount within ten days of award. Specialized building automation and security systems are proprietary to Johnson Controls, and the project involves hazardous material abatement for asbestos and other materials in Building 5.
Commercial and Institutional Building Construction

POSTED

about 19 hours ago

DEADLINE

in about 12 hours
View Details
NAICS: 332919
New
Federal
4820--Boiler Blow-Off Valves - STC
Solicitation # 36C26327Q0111
The Department of Veterans Affairs, Network Contracting Office 23, has issued a Sources Sought Notice to conduct market research for the procurement of three Boiler Blow-Off Valves for the St. Cloud VA Health Care System. The required equipment is intended for a 2008 Fire Tube Cleaver Brooks Boiler (S/N: 200-600-200) and must meet ASTM A216/A216M WCB standards. The government is seeking Yarway P/N 2 inch 3488-R Blow-off Valves or a technical equivalent, specifically noting that sliding disc or globe-type valves are prohibited. Delivery is to be made to the St. Cloud VA Health Care System Warehouse in St. Cloud, Minnesota, with shipping costs to be included in the pricing. This notice is released under FAR Part 10 for planning purposes and does not constitute a formal solicitation or a commitment to contract. The government is specifically looking for Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), or other small business sources under NAICS 332919, which has a size standard of 750 employees. Interested parties must submit a capability statement via email to Contracting Specialist Erica Miller by 5:00 PM CST on November 23, 2026. Submissions must include the offeror's name, address, UEI number, point of contact information, SDVOSB/VOSB status, and GSA Federal Supply Schedule contract details if applicable.
Other Metal Valve and Pipe Fitting Manufacturing

POSTED

about 19 hours ago

DEADLINE

in 11 days
View Details
NAICS: 333415
New
Federal
4120--SPECIAL Duplex Strainer - MPLS
Solicitation # 36C26327Q0106
Solicitation 36C26327Q0106 is a total small business set-aside request for quotes issued by the Department of Veterans Affairs Network Contracting Office 23. The procurement seeks a firm fixed price award for one 20-inch duplex strainer and O-ring gasket, brand name or equal to Keckley, for the Minneapolis VA Health Care System. The equipment must adhere to strict physical specifications, including a center-to-center footprint not exceeding 95 inches and overall assembled dimensions of 130 inches in length, 50 inches in width, and 90 inches in height. The performance period is scheduled from November 19, 2026, to March 22, 2027, with a required delivery date of March 15, 2027, shipped FOB Destination. The government will utilize a price technically acceptable process, awarding the contract to the technically acceptable quote with the lowest evaluated price. To be considered, offerors must provide a narrative detailing their ability to complete the statement of work, subcontracting details, and complete pricing for all line items. The award includes a one-year warranty covering defects in materials, workmanship, replacement parts, and freight. Proposals must be submitted electronically to the contract specialist in two separate volumes covering pricing and technical qualifications, ensuring all required certifications, including the Buy American Certificate and SBA registration, are provided.
Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

POSTED

2 days ago

DEADLINE

in 3 days
View Details
NAICS: 621511
New
Federal
NWI Offsite Pathology Services
Solicitation # 36C26326R0063
The Department of Veterans Affairs, Nebraska-Western Iowa Health Care System, is soliciting a Fixed Price, Indefinite Delivery, Indefinite Quantity (IDIQ) contract for offsite medical laboratory, pathology, and testing analysis services. The selected contractor will be responsible for pre-analytic processing, analysis, and reporting of clinical and anatomical pathology specimens, including the provision of all necessary personnel and specialized collection and transportation supplies. While the VA handles most specimen collection and preparation, the contractor is responsible for grossing global surgical pathology cases and must return all slides and blocks to the VA for permanent storage. The contract features a five-year ordering period beginning April 1, 2027, with a total small business set-aside. Award will be based on the Lowest Priced Technically Acceptable (LPTA) quote, with technical acceptability contingent upon CAP, Joint Commission, and CLIA accreditations, as well as a review of past performance from the previous five years. The contractor must adhere to strict quality standards outlined in the Quality Assurance Surveillance Plan, including a 100 percent accuracy rate for specimen labeling and specific turnaround times for cytology and autopsy reports. Key requirements include compliance with HIPAA, the Privacy Act, and hazardous materials regulations for transporting biological substances. The contractor must also maintain specific insurance coverages, including general liability and employer's liability, and ensure all personnel undergo background investigations per VA security standards.
Medical Laboratories

POSTED

3 days ago

DEADLINE

in 11 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS