J065--626-21-4-4193-0050, Air Compressor Bldg 2 (VA-21-00082653)

Active
36C24921Q0517Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs, through the Tennessee Valley Healthcare System’s Murfreesboro Campus, intends to award a sole source, firm fixed price contract to Dunbar Mechanical Contractors, LLC for the replacement and upgrade of the control air air compressor system in Building 2. The scope includes removing an aging 2006 Quincy duplex reciprocating air compressor, eliminating a kitchen reciprocating compressor, and installing a new enclosed, oil-less triplex scroll compressor with supporting equipment including one new air storage tank and two refrigerated air dryers. The new system will improve operational efficiency, reduce maintenance needs, and support environmental controls within the building. The work is to be performed within 45 calendar days during standard working hours, coordinated with VA personnel, and includes all labor, materials, equipment, and disposal of removed equipment in compliance with federal environmental regulations. The new compressor system must meet specific performance criteria including 37.5 SCFM at 100 PSI, operate on 480-volt 3-phase power, and have features like sound insulation, energy-efficient variable pump drive, and a comprehensive control panel with remote monitoring capabilities. Installation involves modifications to airline plumbing between multiple rooms, electrical connections, and the creation of a housekeeping pad for the equipment. Temporary air supply arrangements will be coordinated during installation to avoid service interruptions. The contractor is also responsible for warranty coverage of one year on equipment and workmanship. This sole source award is justified under FAR 6.302-1(a)(2)(ii) based on the unique capabilities of Dunbar Mechanical Contractors, LLC, and responses from other vendors will be considered only if received by a specified deadline, with final purchasing discretion resting with the government.

General Info

Sole source contract to Dunbar Mechanical for 45-day compressor system upgrade, including installation and warranty.

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

TN

Set-Aside

NONE

Documents

1

Notice of Intent to Sole Source 36C249-21-AP-3493 Air Compressor Replacement

DOCX, High priority: read this firstspecial-notice
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)
Contacts1 person available
OfficeMURFREESBORO, TN, 37129, USA
Office AddressMURFREESBORO, TN, 37129, USA
Contacts
John E. McDanielContract Specialist

Full Description

Show more
Page 2 of 2 NOTICE OF INTENT TO SOLE SOURCE 36C249-21-AP-3493 On behalf of the Tennessee Valley Healthcare System, the Murfreesboro Campus of the Veterans Affairs Medical Center has a requirement that the Office of the Network Contracting Office (NCO) 9 is issuing this Intent to Sole Source. THIS IS NOT A REQUEST FOR QUOTE (RFQ) AND NO SOLICITATION IS AVAILABLE. The Department of Veterans Affairs intends to award a Firm Fixed Price award to a single source under the authority of FAR 6.302-1(a)(2)(ii), Only One Responsible Source and No Other Supplies or Services will Satisfy Agency Requirements. This requirement is for a contractor to provide all transportation, labor, tools, parts, equipment and materials necessary to replace the existing control air- air compressor, add 1 air storage tank, add 1 refrigerated air dryer, replace 1 refrigerated dryer and eliminate the kitchen used reciprocating compressor in Bldg. 2 at the Tennessee Valley Healthcare System (TVHS), Alvin C. York Campus, 3400 Lebanon Pike, Murfreesboro, Tennessee, 37129. The Contractor will be required to complete the task within 45 calendar days of award of this contract. Work shall be performed Monday through Friday, excluding any Federal Holidays, during normal working hours of 7am-3:30pm. This work must be coordinated with the VA COR. The existing control air- air compressor is a 2006 model Quincy duplex reciprocating air compressor that is nearing its end of life use. The refrigerated dryer is beyond the expected useful life of the equipment and is too small to properly dry the compressed air. By updating the air compressor, adding an air tank and installing a new air dryer, Engineering will be able to eliminate the reciprocating air compressor utilized by NFS for cleaning food carts, reducing maintenance requirements, assisting with removal of heat in the service room it is contained in and reducing power consumption in the building. The control air is utilized in the building for environmental controls (heating and air conditioning as well as damper controls in the building s air handler units. The new equipment will be installed at a new location and the existing equipment shall be removed after the tie in of the new equipment. The contractor is to provide all transportation, labor, parts, tools, equipment, parts and materials to completely install a new compressor, new air storage tank, 2 new air dryers, perform air line connections between 3 service rooms, the contractor will plumb to and utilize the existing upright air storage tank in Bldg. 2 Rm G25A. The new compressor shall be an enclosed triplex, oil less scroll type compressor set up similar to or matching the Powerex SET1507HP consisting of 3 - 5 horsepower motors operating on 480-volt 3 phase power, performance of the new compressor shall meet or exceed 37.5 standard cubic feet per minute (SCFM) at 100 pounds per square inch (PSI), please see specification below. The new refrigerated air dryer shall be sized to sufficiently dry the air at the same air flow rating of the air compressor and operate on 120 volts. The contractor shall install the new tank, compressor, and dryer in RM. G20. The contractor will install all required airline plumbing, valves and regulators, perform factory required start up on the new air compressor, replace the existing refrigerated air dryer and the existing air compressor in Rm G25A and remove the Ingersoll Rand air compressor in G21. The contractor will take possession of the removed air dryer, Quincy duplex compressor system, the Ingersoll Rand reciprocating compressor and properly dispose of the equipment. The contractor will work with VA Engineering employees to set up a temporary air supply while the compressor and dryer are being replaced. Air Dryers: The refrigerated air dryer to be installed with the compressor and new air tank shall be sized to match or exceed the SCFM of the air compressor, the replacement air dryer shall be sized to meet the needs of the control air system in G25A, the dryers shall have environmentally safe freon, the dryers shall operate on 120 volt 20 amp circuit and have a cord and plug for means of disconnect, the dryers shall be wall mountable, the dryers shall have a power switch and monitor status of the equipment and have an integrated alarm to report any dryer operational failures. Air Compressor: Scroll Enclosed Series system complete with multiple (3) oil less rotary scroll compressors, mounted inside of a rigid steel enclosure. The compressor unit shall operate on 480-volt 3 phase power system. Enclosures to have a powder coated finish and include sound deadening insulation. Noise levels shall not exceed 60 dba with all compressor units in operation. Each compressor pump shall have a 1750-rpm TEFC motor, V-belt drive, and air-cooled aftercooler. System to include the Variable Pump Drive Operating System controller for energy efficiency. OILLESS SCROLL COMPRESSOR PUMP Each compressor shall be belt driven oil-less rotary scroll single stage, air-cooled, oil-less construction with absolutely no oil needed for operation. The rotary design shall not require any inlet or exhaust valves and shall be rated for 100% continuous duty. Tip seals shall be of a composite PTFE material and be rated for 8,000 hours operation. Compressor bearings shall be external to the air compression chamber and shall be able to be re-greased in the field for extended life. Patented re-grease ports shall be located on the front side of the pump allowing service without removing the pump drive pulley. Bearings shall have an MTBF life of no less than 33,000 hours. Compressors with bearings that are not accessible for service have a limited life span and shall not be accepted. Pump crankshaft and main bearing housing shall be constructed of heavy duty Cast Iron for maximum durability. Compressors shall have an integral radial flow fan for cooling and shall not require any additional electric cooling fans. Maximum pressure is 145 PSIG. Each compressor pump shall be provided with a dedicated electric drive motor, discharge check valve, flex connector, air-cooled after-cooler, high temperature shut down switch. AIR-COOLED AFTERCOOLER Aftercoolers shall be provided for each compressor unit to reduce discharge temperatures. Aftercoolers are constructed of extruded aluminum and installed at the discharge of each compressor. CONTROL PANEL The controls shall be factory integrated with the compressor cabinet and UL listed. A lighted on/off switch is provided along with a user friendly, touch screen, HMI type display panel. The controls will operate and continuously monitor the system and provide information and alarms to the user through the HMI display. Features include display of system pressure, pump run status, pump fault conditions (high temperature shutdown, motor overload fault), maintenance counters and warnings, system trends, and pump Hand/Auto control. Password protected system setup mode allows user to adjust system pressure set points, enable auto restart function, reset alarms, and reset maintenance counters. Compressor operation shall include the Variable-Pump-Drive control logic. Each compressor pump is automatically staged on or off individually based on actual system demand. Energy efficiency is maximized at all usage levels. Lead compressor status will rotate every 10 minutes to maintain equal run hours. Dry contacts are provided for remote monitoring of compressor fault conditions. Work Requirements Contractor is to purchase and supply all new equipment, any associated hardware, piping, regulators, and electrical hardware required to perform a complete and professional installation of the purchased devices in this scope of work. The contractor is to coordinate with the COR or Engineering Maintenance and Operations personnel for the installation of the new equipment in the northwest corner of Bldg. 2 Rm G20. Install the new compressor and air tank in Bldg. 2 Rm G20, installation of the compressor to include a properly sized concrete equipment housekeeping pad. Provide manufacturers required start up on the new compressor. The contractor will provide for and perform electrical connection from the VA provided disconnect to the new equipment in Rm G20. The contractor will provide any required flexible hoses to properly isolate the compressor supply airline from vibrations to the main air supply line. The contractor will install 1 new refrigerated air dryer in Rm. G20, ensure of proper size to match the output of the air compressor system. VA to provide electrical circuit/receptacle for the dryer installation. The contractor shall replace the existing air dryer in Rm G25a with a properly sized refrigerated air dryer based on the CFM utilized for the air conditioning controls, confirm with the COR or Engineering Maintenance and Operations personnel. Install copper piping of adequate size from Rm G20 to Rm G25a to connect air supply to the existing air tank, provide isolation valves and a service connection point to connect a portable compressor in the event of an emergent need. Provide new isolation valves and regulator and connect air piping from the new compressor to the existing airline feed to the kitchen use airline. Airline feed to the kitchen is located in room G20. The contractor shall remove and properly dispose of the Ingersoll Rand compressor system in Rm. G21 and all associated piping abandoned after the installation of the new compressor. Contractor will coordinate with VA mechanics to set up a VA supplied temporary air supply prior to or at the time of disconnecting the existing compressor. The contractor will coordinate with the VA mechanics to install 2 means of an emergency air supply quick connect to enable connection of a temporary compressor at each end of the supply line at the air dryer, connectors need to be approved by VA Engineering COR or lead mechanic prior to installation. The contractor will install ball valves and bypass piping around the air dyers, valves to be approved by VA Engineering COR or lead mechanic prior to installation. The contractor shall complete electrical connection from the VA provided disconnect to the new air compressor and piping of air lines associated with the scope of work. Electrical work and piping shall be neat and professional in appearance and meet any NFPA 70, 99 and UPC codes. Contractor will remove and properly dispose of the existing refrigerated air dryers, the Quincy duplex air compressor system the Ingersoll Rand compressor and any associated hardware and piping not to be in-service upon completion of the installation. Disposal of the equipment shall meet any state and federal EPA guidelines for disposal of hazardous wastes (Freon). Contractor shall provide a 1-year equipment and workmanship warranty on all supplied and installed equipment in this scope of work. Responsibility of the contractor stops at the tie in point of the existing equipment/piping to remain in place upon completion of the work. NCO 9 intends to award this requirement as a sole source purchase order under the provision of Federal Acquisition Regulation (FAR) 6.302-1 to Dunbar Mechanical Contractors, LLC. Based on market research, the required equipment and services can only be purchased from Dunbar Mechanical Contractors, LLC. Therefore, the sole source award to Dunbar Mechanical Contractors, LLC is in the best interest of the government. The North American Industry Classification System (NAICS) code for this requirement is 811310 with the size standard of $8 million. This notice of intent is not a request for proposals or quotes. Any vendor who believes it can meet the requirement as stated herein may submit a response, which will be considered only if received by 18 August 2021 at 5:00 pm CT. Responses to this posting must be in writing and submitted to contact@example.gov. A determination not to compete the proposed order based upon the responses to this notice is solely within the discretion of the government. SAM: Interested parties shall be register in the System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling +1 (555) 000-0000.

Similar Contracts

Same NAICS industry code

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 5 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 811310
New
SLED
Roseville Electric Utility – Gas Compressor Maintenance
Solicitation # 07-137
The City of Roseville is soliciting proposals for Gas Compressor Maintenance Services to support the Roseville Energy Park and the Roseville Energy Center and RPEAK. The selected contractor will provide all labor, supervision, technical expertise, specialized tooling, equipment, and materials necessary for both scheduled preventive and corrective maintenance on natural gas compressors, specifically Gas Packagers and Ariel models, and their associated auxiliary systems. The contract is intended to run for an initial term of five years, with services estimated to commence in April or May. This is a prevailing wage project requiring adherence to all fair employment laws, with certified payroll required for contracts exceeding 25,000 dollars. The successful proposer must provide a 100 percent Faithful Performance Bond and a 100 percent Labor and Materials Bond. Proposals are due by December 17, 2026, and must include a Proposer’s Certification, a Non-collusion Declaration, a Levine Act Disclosure Statement, and proof of active registration with the California Secretary of State. Award will be made to the responsible proposer determined to be the most advantageous to the City through a formal evaluation panel process. Invoicing is to be submitted monthly, delineated by task and personnel, with payment terms set at 30 days following receipt of satisfactory services.
City of Roseville

POSTED

about 6 hours ago

DEADLINE

in about 2 months
View Details

More opportunities from Department Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)

Same awarding agency

NAICS: 621111
New
Federal
Q501--Locum - Anesthesiology Physician Services - 621 5-YR w/Orders 4/1/27-3/31/32
Solicitation # 36C24927Q0035
The Department of Veterans Affairs, Veterans Health Administration, is conducting market research through a Sources Sought Notice to identify qualified sources for locum tenens anesthesiology services at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The requirement involves providing board-certified anesthesiologists to support surgical and procedural operations, including pre-operative evaluations, anesthesia administration, post-anesthesia care, and emergency services. The anticipated period of performance is five years, projected from April 1, 2027, to March 31, 2032. On-call coverage is required for weekdays from 5:30pm to 7:00am and 24-hour coverage on weekends, with strict response times of 15 minutes by phone and 30 minutes for on-site arrival. The potential contract falls under NAICS code 621111 with a small business size standard of 16 million dollars. Interested respondents must maintain active registration in the System for Award Management and those claiming SDVOSB or VOSB status must be verified through the Small Business Administration. Performance will be monitored via a Quality Assurance Surveillance Plan using Focused and Ongoing Provider Practice Evaluations, with a 100 percent acceptable quality level for patient access and safety reporting. All personnel must hold full and unrestricted licenses, possess National Provider Identifiers, and complete mandatory VA training in HIPAA, infection control, patient safety, and cybersecurity.
Offices of Physicians (except Mental Health Specialists)

POSTED

about 10 hours ago

DEADLINE

in 18 days
View Details
NAICS: 561320
New
Federal
R425--Temporary Operations and Maintenance Staffing Services for Skilled Trades Louisville VA Medical Center, Kentucky
Solicitation # 36C24927Q0030
The Department of Veterans Affairs is conducting market research to identify qualified businesses for temporary operations and maintenance staffing services at the Louisville VA Medical Center, including the New Louisville and Robley Rex facilities and other catchment area locations. This requirement focuses on supporting facility activation, commissioning, and ongoing operations for mission-essential healthcare infrastructure and life-safety systems. The anticipated contract structure includes a 12-month base period with two one-year option periods and is designated as a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS code 561320. The scope involves recruiting and supervising skilled trades personnel, with estimated staffing needs for eight Utility Systems Repairer-Operators, four HVAC Mechanics, four Maintenance Mechanics (Multi-Trade), and three Pipefitters/Plumbers. Contractors must provide all necessary tools, PPE, and uniforms, while ensuring personnel meet strict qualifications, such as three years of relevant experience and specific certifications like EPA Section 608 for HVAC roles. Key performance requirements include providing routine staffing within 10 business days, filling critical vacancies within five business days, and maintaining 24/7 coverage for USRO personnel. All staff must pass VA background investigations, obtain PIV badges, and comply with OSHA, NFPA, and infection-control standards.
Temporary Help Services

POSTED

1 day ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS