Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on March 28, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP)

Closed
N6449825P510122Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541511 - Custom Computer Programming Services

Place of Performance

Philadelphia, PA, USA

Set-Aside

NONE

Documents

1

NSWCPD RFI - Mircom NRE Services for Machinery Control Systems FACP

DOCX, High priority: read this first3 pages · rfi
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Nswc Philadelphia Division
Contacts1 person available
OfficePHILADELPHIA, PA, 19112-1403, USA
Office AddressPHILADELPHIA, PA, 19112-1403, USA
Contacts
Stefan Kitzinger

Full Description

Show more
RFI THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). NSWCPD has a requirement for Mircom Non-Recurring Engineering Services (NRE) for Machinery Control Systems (MCS) Fire Alarm Control Panel (FACP) The Contractor shall provide Non-Recurring Engineering (NRE) support services to further the development of fire alarm control panel and complete the following objectives: Enhance the FX-4000N platform by incorporating dual temperature trigger points for the System Sensor 5251 Heat Detector when used with the ALCN-4792MISO loop adder in CLIP mode. Introduce two reporting thresholds based on pulse width measurements: 600-1400 - s = Normal 1401-1750 - s = 105'F Alarm Above 1751 - s = 125'F Alarm These thresholds align with the sensitivity specifications provided by System Sensor, allowing a tolerance level of - 50 ?s (pulse width) or approximately - 3-4'F. The system will adhere to the standard alarm temperature settings of 105'F (standard) and 125'F (high temperature) Currently, the configuration tool from Securiplex supports defining alarm points between 35'F and 189'F. This project will ensure compatibility and accurate temperature reporting within this range. Remove lockout feature from MGC-4000 configuration that denies user access to the panel after five (5) failed password attempts The LHD/A MCS Team will take ownership of the completed deliverables and retain the right to use said deliverables through the consideration of a suitable manufacturer. The Contractor shall acknowledge that they retain no right to the completed deliverables. APPLICABLE DOCUMENTS Navy Issuances https://www.secnav.navy.mil/doni/default.aspx DOD Issuances https://www.defense.gov/Resources/Forms-Directives-Instructions/ NAVSEAINST Library https://www.navsea.navy.mil/Resources/Instructions/ The Contractor shall reference and utilize the latest version available when performing tasks within this PWS. REQUIREMENTS Contractor shall enhance the FX-4000N platform by incorporating dual temperature trigger points through the completion of the following phases: Requirement Specification & Feasibility Study Define firmware and configurator change requirements. Conduct an exploratory study and initial testing on 5251 System sensor heat sensors. Firmware & Configurator Development Develop and implement necessary changes in firmware and the configurator. Conduct QA testing to ensure accurate reporting and compliance with specifications. Contractor shall modify the MGC-4000 lockout configuration through the completion of the following phases: Upgrade the MGC-4000 configuration locking mechanism for US Navy panel. Update firmware and configurator accordingly. Perform Internal QA testing for validation of locking mechanism. CDRLS Status Report: (CDRL A001) - Contractor shall provide status reports as needed. SUBMISSION OF RESPONSES: Responses shall include specific details regarding the ability to provide the required items to meet the needs of the Government. Responses shall discuss how your product/service will meet the requirements. Responses are not to exceed two (2) pages. Responses shall be in electronic format. A cover page for the response shall be included. The cover page shall include the company name, address, CAGE Code, Business Size Status for the North American Industry Classification System (NAICS) code of this RFI and points of contract (names, email, and telephone numbers) at a minimum. The cover page is not considered in the total page count. NSWCPD will accept only electronic unclassified submission of responses. Responses shall be sent to Stefan Kitzinger at contact@example.gov with the subject line "RFI N6449825P510122." All responses shall be unclassified and submitted no later than 03:00 PM EST on 12 April 2025. This RFI is for market research purposes only and does NOT constitute a Request for Proposal (RFP). This notice shall not be construed as a contract, a promise to contract, or as a commitment of any kind by the Government. The Government is NOT seeking or accepting unsolicited proposals. This RFI Notice is issued solely for conducting market research in accordance with FAR Part 10 and gathering information for planning purposes. The Government WILL NOT PAY for any information received in response to this RFI, and the Government will not compensate the respondent for any cost incurred in developing the response to this RFI. The Government will not release any information marked with a proprietary legend received in response to this RFI to any firms, agencies or individuals outside the Government without written permission in accordance with the legend. Please be advised that all submissions become Government property and will not be returned. PHONE CALLS WILL NOT BE ACCEPTED.

More opportunities from Department Of Defense → Nswc Philadelphia Division

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS