Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on March 30, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

MSA Rapid Intervention Portable Air Supply

Closed
F2M3CC7012AW02Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333912
New
SLED
Wilcox County Board of Commissioners (SCBA Compressor and fill station RFP)
Solicitation # PE-77234-NONST-2027-000000012
The Wilcox County Board of Commissioners is soliciting proposals for the procurement, delivery, and installation of a complete Self Contained Breathing Apparatus (SCBA) Compressor and Fill Station for the Wilcox County Fire Department. The scope of work requires a four-stage, air-cooled, oil-lubricated compressor from manufacturers such as Arctic, Bauer, or Mako, featuring a minimum operating pressure of 6,000 PSI and a capacity of 10 CFM. The system must include a Grade E breathing air purification system with carbon monoxide monitoring, four ASME/DOT storage cylinders with a priority fill panel, and an enclosed containment fill station meeting current NFPA requirements, including a safety interlock. The selected vendor will be responsible for the full installation, system and leak testing, operational demonstrations, air quality certification, and on-site training for personnel. Proposals must be submitted in a sealed envelope labeled specifically as a sealed bid and delivered to the Commissioner's Office in Abbeville, Georgia, by 2:30 PM on November 19, 2026. Bidders must provide a GSICA Contractor affidavit, drug-free workplace certification, and equal opportunity employer certification, with minority and DBE contractors encouraged to apply. All pricing must be inclusive of shipping and remain valid for four months following the bid opening. Evaluation will be based on technical compliance and product quality, though alternate brands of equal or better quality may be proposed. The award may be issued to a single contractor or split among multiple vendors at the discretion of the Board of Commissioners.
Wilcox County Board of Commissioners

POSTED

about 7 hours ago

DEADLINE

in 30 days

General Info

NAICS

333912 - Air and Gas Compressor Manufacturing

Place of Performance

JBSA Fire Emergency Services Bldg 3830 3201 Schofield Rd, Joint Base San Antonio Fort Sam Houston, TX, 78234, USA

Set-Aside

SBA

Documents

1

RFQ_%28Portable_Air_Supply_RIT%29.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts1 person available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
HEATHER CONSOLAContracting Specialist

Full Description

Show more
This announcement constitutes the only solicitation; proposals are being requested and a separate RFQ will not be issued. The solicitation number is F2M3CC7012AW02 and is issued as a Request for Quotation. This combined synopsis/solicitation incorporates provisions and clauses are those in effect through Federal Acquisition Circular 2005-87, DFARS change notice 20160226 and AFAC 2015-1001. This requirement is set aside for small businesses. The NAICS code is 333912 and the size standard is 1,000 Employees. MSA Rapid Intervention Portable Air Supply System (The quote shall be effective for 60 days after submission of quote) Please respond to this RFQ by emailing response to: TSgt Heather Consola at E-mail: heather.consola@us.af.mil no later than 12:00pm CST, 7 April 2017 - Friday (or sooner if possible) in order to be considered timely. Any quote, modification, revision, or withdrawal of a quote received after the exact time specified above shall be determined as late and will not be considered unless received before award is made, the Contracting Officer determines that accepting the late quote would not unduly delay the acquisition, and it was the only quote received. Please contact TSgt Heather Consola with additional questions at the above noted email address or call (210) 671-6415. Please provide a quote for the line items listed below. Failure to quote on all CLINs may render the quote unacceptable and ineligible for award consideration. ITEM DESCRIPTION QTY Unit 0001 MSA RescuAire II high pressure (4500psi) Rapid Intervention Pack with Responder Regulator. Item #10100097(Brand Name) Delivery to JBSA Fire Departments 4 EA

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS