Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 14 at 2:00 PM ET

Register Free →

Overhead Mounted Vacuum Switched Capacitor Bank Supplier

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Documents

This scope was carved out of MS 08-26-02.

The full solicitation package (5 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Purchase of Pad Mounted and Overhead Power Capacitors

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Engineering and Operations
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supplies and factory tests outdoor, three-phase, 15kV class, overhead type switched power capacitor banks for prime contractors on Alameda Municipal Power projects. Assembles banks with integrated switching equipment, protective devices, and wireless current sensor systems. Performs routine production tests in accordance with IEEE Std 18 and IEEE Std 1036. Delivers two complete overhead mounted capacitor banks.

Similar Contracts

Same NAICS industry code

More opportunities from California → Engineering and Operations

Same awarding agency

New
SLED
Purchase of Pad Mounted and Overhead Power Capacitors
Solicitation # MS 08-26-02
The City of Alameda, through its Engineering and Operations agency, is soliciting bids for the purchase of 15 kV class, three-phase switched power capacitor banks for a 60 Hz medium-voltage distribution system. The scope includes the delivery of five pad-mounted vacuum switched capacitor banks and two overhead mounted vacuum switched capacitor banks, both requiring SEL 734W microprocessor-based controllers. All equipment must be designed and tested according to ANSI, IEEE, NEC, and NEMA 3R standards, featuring corrosion-resistant construction and UV-resistant finishes. The contract requires a guaranteed lead time not exceeding 36 weeks from award to delivery at the AMP Service Yard, with a warranty period of 12 months from installation or 18 months from shipment. The agreement will be awarded to the lowest responsive and responsible bidder based on overall lump sum pricing, though the agency reserves the right to issue separate awards by capacitor type. A five percent preference is available for certified local businesses. Bidders must submit technical data sheets, delivery schedules, and experience references by November 4, 2026. Key administrative terms include NET 30 payment terms, F.O.B. Destination shipping with prepaid charges, and a requirement for the manufacturer to provide 48-hour notice prior to delivery. Final inspection and acceptance will occur at the buyer's plant following mandatory factory testing of insulation resistance, applied voltage, and functional controls.

POSTED

3 days ago

DEADLINE

in 23 days
View Details
NAICS: 541330
SLED
On-Call Pole Loading and Structural Engineering Services
Solicitation # PS 09-26-01
Alameda Municipal Power is soliciting proposals to establish a pool of qualified engineering firms for on-call pole loading and structural engineering services to support its electric distribution system. The scope of work includes pole loading and structural calculations, field investigations, engineering recommendations, and joint-use support, specifically for capital projects, maintenance, and equipment modifications. All services must be performed using O-Calc Pro as the standard analysis platform and must comply with California Public Utilities Commission General Order 95, as well as other applicable codes such as ANSI O5.I and Cal/OSHA requirements. Engineering work requiring professional judgment must be performed under a licensed California Professional Engineer and signed and sealed when required. The agency intends to establish up to three five-year agreements with a not-to-exceed budget per task structure. Work will be authorized on an as-needed basis, with expedited assignments requiring completion within five business days. Compensation is based on established unit prices, hourly rates, or task-specific caps, with progress payments made based on the percentage of project completion. Proposals are due by October 28, 2026, and will be evaluated based on demonstrated competence and professional qualifications, with a 5 percent preference given to local businesses within the City of Alameda. Required submittals include a minimum qualifications questionnaire, a non-collusion declaration, and a detailed proposal organized into eight specific chapters.
Engineering Services

POSTED

10 days ago

DEADLINE

in 16 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown