Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

Pinehurst Road Culvert Repair, Project# WL084A, Drainage Permit# 402-26 (ED26-00402), CP# 26-16

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The project involves replacing a failing 72-inch corrugated metal culvert beneath a private driveway at a residence on Pinehurst Road in Moraga, California, to restore and improve stormwater conveyance. The existing culvert has suffered structural failure due to erosion, which has compromised the upstream bank and the driveway itself. It will be removed and substituted with a 12-foot span, 5-foot rise bottomless arch culvert featuring full-beveled ends and concrete footings to provide greater durability and flow capacity. Rock armoring will be installed to stabilize the adjacent creek slopes and prevent future erosion-related damage. All construction activities will occur on the property owner’s land, with equipment staged only on existing paved areas to minimize environmental disruption. Temporary water diversion and dewatering measures will be employed during installation, and minimal removal of riparian vegetation may be necessary to facilitate access. Best management practices including silt fencing and straw wattles will be implemented to control sediment and protect water quality. Applicable regulatory permits, including a Drainage Permit from Contra Costa County, will be secured prior to beginning work. Construction is scheduled to begin in the summer of 2026 and is expected to take no more than 60 days. The project is identified under Drainage Permit #402-26 and Project #WL084A, with primary contacts being Syd Sotoodeh, Senior Planner, and Sandeep Kajla, Project Manager, both with Contra Costa County.

General Info

Replace failing 72-inch culvert with 12-ft bottomless arch culvert, add rock armoring and sediment controls, permit #402-26, construction summer 2026.

Agency

California → Contra Costa County

NAICS

237990 - Other Heavy and Civil Engineering ConstructionView NAICS

Place of Performance

Brier Lane, Moraga, CA, 94516

Set-Aside

NONE

Documents

(1)

CP#26-16 NOE Pinehurst Rd Culvert Repair

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Contra Costa County
Contacts2 people available
OfficeN/A
Organization / Agency
California → Contra Costa County
Office AddressN/A
Contacts
Syd SotoodehSenior Planner
Sandeep KajlaProject Manager

Full Description

Show more
The purpose of this project is to replace a driveway to a private residence at the location identified above. This driveway provides a single point of access to the permittee’s private residence. Additionally, the existing culvert beneath the driveway has failed and needs to be replaced to maintain stormwater conveyance. The replacement culvert will be required, at a minimum, to maintain existing flow capacity or increase flow capacity compared to the existing structure. The project would replace a failing 72-inch corrugated metal culvert that supports the driveway, where erosion has damaged the upstream bank and driveway. The existing culvert and hardscaped surroundings would be removed and replaced with a bottomless arch culvert (12-foot span, 5-foot rise, full-beveled ends) supported by concrete footings, along with rock armoring to stabilize the creek slopes, thereby reducing the risk of further damage to the driveway. Equipment for the project may include an excavator, backhoe, dump truck, or other similar equipment. All equipment used for the project will be staged on existing paved areas or roadways, on the permittee’s private property. Temporary water diversion and dewatering will be required. Minor removal of riparian vegetation may be necessary for access. Applicable best management practices such as silt fencing and straw wattles will be implemented, and regulatory permits will be obtained before construction. Construction is anticipated to start in the summer of 2026 and is anticipated to take up to 60 days. A Drainage Permit will be issued by the County to the private property owner for this project.

Similar Contracts

Same NAICS industry code

NAICS: 237990
New
Haleiwa Small Boat Harbor Maintenance Dredging and Revetted Mole Repair
Solicitation # haleiwa-small-boat-harbor-maintenance-dredging-revetted-mole-repair
Healy Tibbitts Builders, Inc. is seeking small business subcontractors and suppliers for the Haleiwa Small Boat Harbor Maintenance Dredging and Revetted Mole Repair project in Oahu, Hawaii. The scope of work includes dredging within federal jurisdiction to a depth of -12 feet Mean Lower Low Water with a 1-foot overdepth, involving the removal and ocean disposal of gravel, sand, silt, and clay. Additionally, the project requires revetted mole repairs, which encompass clearing and grubbing, CRM wall repair, tree and vegetation removal, and the reworking or installation of stone to fill voids. The performance period is 200 calendar days from the notice to proceed. The solicitation is an invitation for bid under NAICS code 237990, with a response deadline of September 30, 2026. Bids must be submitted in sealed envelopes, as electronic submissions are not permitted. Evaluation is based on a pass/fail gate for compliance and completeness, with a bid guarantee required at 20 percent of the bid price or 3 million dollars, whichever is less. The contract emphasizes strict quality management, requiring the use of the USACE National Dredging Quality Management Program and a physical on-site presence for the Quality Control Manager. Payment will be processed through the USACE Finance Center, and the project must adhere to EM 385-1-1 safety requirements and specific environmental protections for the Hawaiian hoary bat pupping season.
Healy Tibbitts Builders, Inc.

POSTED

about 14 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 237990
New
SBWRP Reverse Osmosis System
Solicitation # K-26-2469-DBB-3
Garney Pacific, Inc. is acting as the general contractor for the SBWRP Reverse Osmosis System project in San Diego, California, for the City of San Diego. With an estimated bid value of 19.3 million dollars, the project scope involves designing the removal of existing trailer-mounted Electrodialysis Reversal, slab-mounted Membrane Filtration, and Reverse Osmosis units. These will be replaced with new slab-mounted Membrane Filtration and Reverse Osmosis units to create a demineralization facility at the South Bay Water Reclamation Plant aimed at reducing total dissolved solids in reclaimed water. The solicitation, identified by bid number K-26-2469-DBB-3 and NAICS code 237990, seeks quotes for various trades including HVAC, plumbing, electrical, concrete, pumping, crane services, aggregate, landscaping, painting, piping insulation, and demolition. The project emphasizes socioeconomic participation, specifically seeking SLBE and ELBE firms with DBE, MBE, WBE, or SBE certifications, and is open to various small business set-asides. All subcontractors are required to utilize union labor and must be prepared to provide a 100% Payment and Performance Bond from a US Treasury listed Surety Company, though Garney will reimburse the bond premium. Contracting will be based on Garney Standard PO and Subcontract Forms, and any exceptions must be submitted as redlines with the quote. Proposals are due by August 27, 2026, at 2:00 PM PT.
Garney Pacific, Inc.

POSTED

about 14 hours ago

DEADLINE

in 13 days
View Details