Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 19, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Q999--589-21-3-1424-0038 - KC - Two-Channel Audiometer Version 2 w/High Frequency Phones

Closed
36C25521Q0382Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers

Place of Performance

Kansas City VA Medical Center Audiology Clinic 4801 E. Linwood Blvd Kansas City, MO 64128, KS, 64128, USA

Set-Aside

NONE

Documents

1

36C25521Q0382.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Jennifer SotomayorContract Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e). SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 337215 (size standard of 500 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following, Adjustable Workstation Requirements All adjustable workstations will have the following common requirements outlined in addition to the configuration specific requirements noted below: ¾ or thicker high-pressure laminate (or equivalent) desk surface in a dark non-reflective color Rounded or tapered edges at all user contact points 2 Under Desk Mounted CPU holders CPU holders to be mounted under desktop surface and not sitting on floor Preferred mounting locations would place CPUs outside of leg and knee zones that would be occupied by a sitting physician Variable height controlled via electric motors with control unit Controls should have capability to store multiple preset heights Workstations should have two separate adjustable platforms, one for the monitors being utilized and one as the work surface for peripherals and writing as necessary All monitor mounts shall allow monitors to rotate, translate side-to-side, tilt, swivel, and adjust forward-and-backward for focal depth Enclosed cable management/tray for routing of power, video, and other computer cables Flexible cable management available for all cables running outside on the tray or enclosed management channels USB connections accessible on the tabletop surface LED task lighting with dimmable controls All electronics should be powered by standard 120V power Specific Radiology Rectangular Configuration Requirements a rectangular Radiology workstation configuration capable of meeting the above requirements and supporting the below hardware: 1 PC quoted through this contract and 1 VA OI&T provided PC 4 Radiology Diagnostic Monitors quoted through this contract, 1 Administrative Monitor quoted through this contract, and 1 VA-OI&T provided 22 monitor Overall workstation working surface depth shall target approximately 44 inches or less Overall workstation width shall target the range of 60 inches to a maximum of 85 inches Specific Radiology Corner Configuration Requirements a corner or L shaped Radiology workstation configuration capable of meeting the above requirements and supporting the below hardware: 1 PC quoted through this contract and 1 VA OI&T provided PC 4 Radiology Diagnostic Monitors quoted through this contract, 1 Administrative Monitor quoted through this contract, and 1 VA-OI&T provided 22 monitor Overall workstation width in either direction shall target the range of 60 inches to a maximum of 85 inches Workstation should be roughly equal length in either direction as opposed to a rectangular desk with short additional work surface. Specific Mammography Rectangular Configuration Requirements a rectangular Mammography workstation configuration capable of meeting the above requirements and supporting the below hardware: 1 PC quoted through this contract and 1 VA OI&T provided PC 1 Mammography Diagnostic Monitor quoted through this contract, 2 Administrative Monitors quoted through this contract, and 1 VA-OI&T provided 22 monitor Overall workstation working surface depth shall target approximately 44 inches or less Overall workstation width shall target the range of 60 inches to a maximum of 85 inches Specific Mammography Corner Configuration Requirements a rectangular Mammography workstation configuration capable of meeting the above requirements and supporting the below hardware: 1 PC quoted through this contract and 1 VA OI&T provided PC 1 Mammography Diagnostic Monitor quoted through this contract, 2 Administrative Monitors quoted through this contract, and 1 VA-OI&T provided 22 monitor Overall workstation width in either direction shall target the range of 60 inches to a maximum of 85 inches Workstation should be roughly equal length in either direction as opposed to a rectangular desk with short additional work surface. Installation Requirements On-site installation at each location to include inside assembly/installation in designated room within the designated space. Vendor to assemble the tables, install all cables within cable trays, attach monitor mounting hardware, lights, USB hubs and under-table CPU holders, calibrate height adjustments and validate full functionality. All shipping costs are to be included in contract All labor, parts, travel costs are to be included in contract All cables and extensions necessary to connect PCs to monitors and peripherals through the adjustable workstations are to be provided by the vendor as part of the contract. Where allowable cable and extension lengths should be kept to a minimum to avoid latency and communication issues. Vendor is responsible to replace all items damaged or missing as identified during on-site installation activities Installation and Shipping are to be coordinated with identified VA POC at each site Vendor to clean-up and remove all packing material, rubbish, etc. after installation activities Building structure, door frames, floors, etc. are not to be modified by vendor during delivery/installation Vendor will be responsible for any damage that occurs to building during installation Vendor to educate and train on-site staff in operation and typical maintenance/troubleshooting Education will include providing any available user manuals and/or service documentation Warranty and Support Requirements All workstations will include at a minimum a 5-year warranty on parts, defects, and early failures. This includes cables, peripherals, and other items that may be internally run in the adjustable workstations. Documentation will also include part numbers for common replacement items and support lines for vendor technical support on each product. Adjustable workstations will additionally include 5-year coverage for labor necessary to replace parts that fail during this period. The information identified above are intended to be descriptive, not restrictive, and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications, or brand name equal. If you are interested, and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number. Please provide general pricing of your products/solution for market research purposes. Catalog list prices, FSS prices, or any other publicized price lists are acceptable. Please submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW. Please provide your DUNS number. Responses to this notice shall be submitted via email to Philip Bouffard at contact@example.gov. Telephone responses shall not be accepted. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 15 hours ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS