Replace Substation Alpha Relay B11912
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
This solicitation, numbered FA466126R0010, is for the replacement of Substation Alpha Feeder Protection Relays at Building 11912 on Dyess Air Force Base in Texas. The selected contractor will be responsible for installing and wiring two government-provided GE 850 Feeder Protection Relays in compliance with NEC and NETA standards. Key requirements include programming the new relays to match the settings of the previous GE 760 models, performing functionality tests without load, and coordinating with the Electrical shop for primary voltage energization. The project concludes with the commissioning and testing of the relays under full base load, witnessed by representatives from Electrical, Contracting, and R&O. This opportunity is a total small business set-aside under NAICS code 811310. Interested parties must submit their responses by September 15, 2026.
General Info
Agency
NAICS
Place of Performance
Dyess AFB, TX, 79607, USASet-Aside
Documents
(3)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
This is a solicitation for the requirement of properly replacing the Substation Alpha Feeder Protection Relays at Building 11912 on Dyess AFB. The Contractor shall install (2) NEW GE 850 Feeder Protection Relays which are provided by the Government. The contractor shall install and wire in (2) new Feeder Protection Relays in accordance with NEC/ NETA standards. The Contractor shall program the (2) new Feeder protection relays to match programming of the previously installed GE 760 relays, via settings provided by the Electrical shop and test functionality without load. The Contractor shall coordinate with the Electrical shop prior to energizing the primary voltage for testing and commissioning. The Contractor shall commission and test the two new relays with full base load once installed with witnesses from Electrical, Contracting and R&O. The Contractor will coordinate with the Electrical Shop before conducting any power outages for acceptance tests if needed.
Please see attachments for details.