Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

Requesting design and construction effort to expand the capacity of the existing SITE 3 WASTE WATER PIT Near Bldg. CNRSV-1711

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac MarianasView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

HZC

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Marianas
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Marianas
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Requesting design and construction effort to expand the capacity of the existing Site 3 Waste Water Pit by sealing, lining, and converting an old concrete vault and providing connection piping between the two pits. This waste water system is part of the oil water separator system that ensures storm water drainage is not contaminated with oil. Current facility waste water pit only has a capacity of 1k gallons of waste water which is insufficient during a heavy rain event. If not improved, the waste water system is at risk of being overcome by accumulated storm water and would overflow causing flooding, erosion, and violation of SPCC requirements. The scope of work is to provide a liner or appropriate sealant in the existing underground tank convault (tank has already been removed) to ensure water tightness. design and install pump and piping system between the existing waste water pit and the converted convault to allow drainage to and pumping from either pit to the existing pipelines towards Polaris point. Check and repair damaged sections of the piping between lower Sasa Valley and Site 3 at Polaris point along Marine Drive at the bridges.

More opportunities from Department Of The Navy → Navfac Marianas

Same awarding agency