Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

HARDENED 13.8 KV CIRCUITS P2 AT PLAYGROUND, POLARIS POINT, NBG

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac MarianasView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

HZC

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Marianas
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Marianas
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
1. Request engineering service and design to provide RFP package. Complete RFP package and put out for award project FY 27 Q3 (May 2027) 2. 35% RFP SOW/IGE (Design) submittal due date: earlier than 19 September 2026; 65% design submittal due date: earlier than 02 November 2026 100% Design submittal earlier than 28 November 2026 and Final Design submittal 24 January 2027. Design release to ACQ : 04 February 2027 3. Draft DD1391 need to be submitted earlier than 20 July 2026 ; Final DD1391 with SME and signed by PWO/ARE to be completed 16 December 2026. 4. Request NEPA/CATEX/SHPO and SAR to start earlier than 20 September 2026 and complete not later than 19 December 2026; PROJECT DESCRIPTION: This purpose of this project is Harden Circuit P-2 at Polaris Point north of Polaris point Drive and west of Guard Station by installing 13.8KV, 5 way switch and primary a new primary duct bank system and new pad mounted transformer to feed existing structure 4410PP, 4427PP, 4429PP, 4439PP, 4445PP and 4446PP. The project also to includes for the removal of all existing overhead primary and secondary feeders and poles and install a new underground pole mounted street lighting system in the area. Reconnect existing 75KVA pad mount transformer feeding ball field lighting system.