This Solicitation opportunity from Department Of Defense was posted on April 8, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
RESPIROMETER
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The contract details the procurement of a digital respirometer, specifically the Model 295 Digital Respirometer, designed for measuring air or gas volume flow up to 200 liters with a resolution of 0.02 liters. The device features an LCD readout and a flow sensing unit with a single moving part that can be easily detached for sterilization via washing, gas sterilization, or cold sterilization. It includes a 9V battery and an adapter, operates in a flow rate range from 5 to 150 liters per minute, with an accuracy of 5% over the range and 2% at the calibration point, and maintains a resistance to flow of 2 cm water at 100 lpm. Packaging requirements emphasize commercial-grade packaging to protect the unit from damage during shipment, with appropriate sealed unit containers and exterior shipping cartons that meet medical marking standards, specifically Medical Marking Standard No. 1. The unit is marked and shipped to ensure safe delivery to the designated location at Keesler Air Force Base within five days of order. The contract is for one unit identified under the National Stock Number 6515-01-696-5384, with quality and technical standards governed by applicable DLA master lists. Bid submissions must specify source and part number details, aligning with Department of Defense acquisition procedures for medical equipment.
General Info
Agency
Contract Value
$1,400NAICS
Place of Performance
301 FISHER ST STE 101, KEESLER AFB, MS, 39534-2519, USASet-Aside
Awardee
Award Issued Date
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Submission Closed
Organization & Contact Information
Full Description
RESPIROMETER.
Respirometer Digital Complete w/ Sensor Controller Adapter to 200 liters. With LCD readout display on the Model. 295 Digital Respirometer. The flow sensing unit has only one moving part and is detachable from the control unit for ease of sterilization and cleaning. It may be washed, gas sterilized or cold sterilized. Comes complete as shown, ready to use with 9V battery and one (1) 22mm female x 22mm female adapter. Range: 0 200 liters. Measurement Type: Air/Gas volume flow (tidal volume). Resolutions: .02 liter. Flow Rate: 5 lpm minimum/150 lpm maximum. Accuracy: 5% over range, 2% at calibration point. Resistance to flow: 2cm of water at 100 lpm.
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED IN A SUITABLE SEALED UNIT CONTAINER CAPABLE OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT THE LOWEST RATE, TO POINT OF DELIVERY CALLED FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1 (MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
UNIT OF ISSUE: EACH (EA)
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
SPE2DS-26-T-8713
SECTION B
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-696-5384 Quantity: 1 EA Purchase Request: 7015672247QTY: 1 Delivery: 5 days ADO
More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
