SSCBC Pharmacy RTU Supply Exhaust and Control Replacements
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Ohio State University is seeking a Design-Builder for the SSCBC Pharmacy RTU Supply Exhaust and Control Replacements (Project OSU-275082). This project involves the comprehensive modernization of mechanical systems for the oncology compounding pharmacy cleanroom (Suite 4200) and the roof of the Stefanie Spielman Comprehensive Breast Center. The scope includes replacing a failing AAON rooftop air-handling unit, installing N+1 redundant exhaust fans, and retrofitting airflow valves with low-pressure Antec Venturi valves integrated into the Building Automation System. Additional work includes sealing above-ceiling partition walls for pressurization and installing chemical-resistant LED cleanroom luminaires. The project is subject to a strict construction budget not to exceed $2,142,199.00 and requires full-system commissioning, third-party certification, and asset tagging. The selection process is a two-stage Best Value selection. First, a qualifications-based RFQ process will develop a short list of at least three candidates based on firm and team experience. Second, an RFP stage will evaluate short-listed firms based on a combination of qualifications and fee. The selected Design-Builder will provide preconstruction services, including Target Value Design and cost estimating, and construction services using an open-book pricing method for subcontracts. The project requires adherence to University Sustainability Standards, OSHA lead exposure limits, and the EDGE Program, with a participation goal of 5% of total compensation. The project timeline includes a qualifications deadline of December 15, 2026, with the final selection of the Design-Builder expected by February 11, 2027.
General Info
Place of Performance
Set-Aside
Documents
1AI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownEverything you need to bid on this one
Open the full contract in your free workspace.
- 1 solicitation documentRead every page
- AI contract breakdown13 sections, Uniform Contract Format
- Buyer contactEmail
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Solicitation
Submission deadline
Response Deadline
Organization & Contact Information
Full Description
For this project, the Owner will be requesting a Competitive GMP at the time of Request for Proposal as part of the Best Value selection process. This project encompasses the comprehensive modernization of the mechanical systems for the oncology compounding pharmacy cleanroom (Suite 4200) on the fourth floor and roof of the Stefanie Spielman Comprehensive Breast Center (SSCBC). Executed within a strict construction budget not to exceed $2,142,199.00, the renovation ensures continuous regulatory compliance and hazardous drug containment. Key mechanical and controls upgrades include replacing the failing AAON rooftop air-handling unit, installing N+1 redundant exhaust fans, and retrofitting all supply and exhaust airflow valves with low-pressure Antec Venturi valves that are fully integrated into the facility's Building Automation System (BAS). Minimal architectural and electrical enhancements include sealing all above-ceiling partition walls to maintain strict room pressurization and replacing existing lighting with chemical-resistant, sealed LED cleanroom luminaires. The scope concludes with comprehensive asset tagging, full-system commissioning, and third-party certification to validate critical environmental controls and airflow performance. The Program of Requirements (“POR”) will be developed as a part of this project by the Criteria Architect/Engineer (“Criteria A/E”), OSU Wexner Medical Center Facilities Engineers. All aspects of the project and related issues will be implemented and operated consistent with the Contracting Authority and/or Owner’s policies and procedures. This project includes asset tagging. The Primary firm submitting for the project is required to have the expertise capable of meeting this prerequisite and is responsible to support their subcontractors to meet this requirement. The Asset Tagging Process Diagram, Asset Worksheet Template, and LOD Matrix can be accessed via the OSU FOD website (https://fod.osu.edu/resources) under Design Guidelines, Specifications, Standards; Specifications and Standards; Building Information Modeling (BIM).
Scope of Services: The Owner will be requesting a GMP as part of the Best Value selection process; therefore, self-performed work will be approved, subject to the firm submitting an acceptable subcontractor plan. The short-listed firms are treated as approved subcontractors for this purpose. There will be no obligation for the selected firm to solicit bids from subcontractors for the purpose of comparing the price of proposed self-performed work. In addition, the contingency utilization provisions related to the award of a low subcontractor bid are waived. The selected Design-Builder (“DB”), as a portion of its required Scope of Services and prior to submitting its proposal, will discuss and clarify with the Contracting Authority and/or Owner, the breakdown of the Agreement detailed cost components, to address the Owner’s project requirements and refine the project schedule. Participate in the Encouraging Diversity, Growth & Equity (EDGE) Program as required by statute and the Agreement. As required by the Agreement, and as properly authorized, provide the following categories of services: develop and maintain estimates of probable construction cost, Target Value Budget/Target Value Design, project schedules, and construction schedules; lead and manage the Schematic Design, Design Development, Subcontractor Prequalification and Bidding process, Construction Documents, Construction and Closeout stages. The project shall follow the applicable University Sustainability Standards: https://fdc.osu.edu/building-design-standards The selected DB will be required to sign the standard agreement provided at time of Request for Proposal. No modifications to the requirements in the agreement will be accepted. Required Professional Liability Insurance will be per General Conditions Articles 10.3.7, 10.3.8 and 10.3.9. The preconstruction and construction services are generally described below. With the exception of self-performed work, subcontracts including but not limited to Plumbing, Fire Protection, HVAC, and Electrical trades will be awarded by the DB to prequalified vendors using a competitive process. The parties will engage in an "open book" pricing method in which all subcontracted work shall be based upon competitive pricing that will be reviewed by the Contracting Authority/Owner, the Criteria A/E and the DB. The Contracting Authority/Owner shall have access to all books, records, documents and other data in the DB's possession related to itself, its subcontractors and material suppliers pertaining to bidding, pricing or performance of the Agreement. Preconstruction Services: The DB will work cooperatively with the Contracting Authority/Owner, Criteria A/E and Project Team, and will provide, among other services, schedule development, estimate development, program verification, schematic design, design development, subcontractor prequalification and bidding, construction documents preparation, constructability review, permits, budgeting, Target Value Budget/Target Value Design, and preconstruction planning throughout the preconstruction stages. Construction Services: The DB shall construct the Project pursuant to the construction documents and in accordance with the schedule requirements. The DB shall hold all subcontracts and shall be fully responsible for the means and methods of construction, weekly progress meetings, testing and inspections, project safety, project completion within the schedule agreed upon in the preconstruction phase, compliance with all applicable laws and regulations including monitoring compliance with all EDGE, equal employment, and prevailing wage requirements, and submitting monthly reports of these activities to the Contracting Authority. All subcontracts shall be on the subcontract form prescribed by OAC Section 153:1- 03-02. The Contracting Authority reserves the right to approve the DB’s selection of subcontractors and any supplemental terms to the subcontract form. The Ohio State University is dedicated to providing a safe and healthy environment for students, patients, staff, visitors and contractors. While not exclusive, guidelines governing safety expectations for construction/ renovation projects within Ohio State buildings are set forth in the Building Design Standards Appendix V and are summarized here: https://fod.osu.edu/resources under the section titled “Construction Site Safety Requirements.” Closeout Services: The closeout for this project is required to be delivered in an electronic cloud-based format using e- Builder Project Management System and adhere to The Ohio State University Project Closeout Standards. The Ohio State University Project Closeout Standards can be accessed via the OSU FOD vender resource website (https://fod.osu.edu/resources) under Post Construction / Close Out. The DB will comply with applicable OSU Wexner Medical Center policies, including the Identification Badge Policy, which incorporates the Non-discretionary Vaccination Policy/Employee Health Infection Control and Background Check Policies, as identified at https://wexnermedical.osu.edu/utility/footer/vendor-interaction. The DB is responsible for all costs incurred related to compliance with these policies. The Davis Bacon Wage Rate Determination applicable to this project is part of this solicitation. The Wage Rate Determination may be modified prior to award. Obtain the Wage Rate Determination by emailing the University Prevailing Wage Coordinator at •••••@•••••.•••Sign up to see this detail. For purposes of completing the Relevant Project Experience Matrix in Section F of the Statement of Qualifications (Form F110-330), below is a list of relevant scope of work requirements for this RFQ: 1. Project Delivery Method (DB with competitive GMP) 2. Project delivery in alignment with strict project budget 3. Experience designing and installing HVAC in support of a Pharmacy or Laboratory space For the purpose of the selection of 10 Relevant Projects in Section F of the Statement of Qualification (Form F110-330), projects must have been completed by the Design Build Firm.
Similar Contracts
Same NAICS industry code
More opportunities from The Ohio State University
Same awarding agency
Get AI-powered intelligence on this solicitation and the ones like it
Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.
Join 900+ contractors already using CLEATUS