This presolicitation notice, managed by the Department of Veterans Affairs, is for the procurement of brand name Stryker surgical video equipment for the Robert J. Dole VA Medical Center in Wichita, Kansas. The equipment is intended for use across various surgical specialties, including urology, gynecology, and arthroscopy. The requirement focuses on high-resolution 4K imaging capabilities, specifically the ability to visualize fluorescence and lighted ureteral stents simultaneously to assist in identifying critical anatomy and assessing tissue perfusion. The procurement includes a comprehensive suite of hardware, featuring six camera control units with 4K resolution and capacitive touch screens, six light sources with infrared lasers, and eleven 32-inch 4K OLED surgical displays with protective covers. Additionally, the order specifies twelve camera heads, six insufflators with smoke evacuation, and a variety of wireless transmitters and receivers to eliminate cabling hazards in the operating room. The package also includes a portable handheld fluorescence imager and its corresponding video processor for intraoperative perfusion assessment. The response deadline for this solicitation is September 22, 2026, with Tracie Raggs serving as the primary point of contact.

General Info

VA procurement of Stryker 4K surgical video equipment for Wichita medical center.

Agency

Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)View Agency

NAICS

339112 - Surgical and Medical Instrument ManufacturingView NAICS

Place of Performance

Wichita, KS, 67218, USA

Set-Aside

NONE

Documents

(1)

36C25526Q0665 - Stryker Surgical Video System

PDFpresolicitation

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhasePresolicitation
Posted

Presolicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Organization / Agency
Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
View Agency Profile
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts

Full Description

Show more

This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See the following Solicitation for further information.


Camera Control Unit


Quantity: 6 EA


Specification/Salient Characteristics:


  • Minimum resolution: 4K
  • Scalable to accommodate future advancements in peripheral device integration and control
  • The ability to assess perfusion for open surgery
  • Intuitive capacitive touch screen LCD interface for ease of operation
  • Capable of accommodating up to 10 different surgical specialties settings for optimal color resolution and brightness
  • User-friendly and easily understood by nursing staff
  • The ability/compatibility to see lighted ureteral stents that when placed, emits infrared light that can be detected to visualize the ureters (critical anatomy) in real time
  • The ability to see fluorescence in 4K and lighted ureteral stents simultaneously
  • CF Rated
  • Capable of visualizing and highlighting lung and ovarian cancer
  • Can showcase over 1 billion reproducible colors
  • Includes dynamic range enhancements that improve visualization in both the highlights and shadows of the picture to increase clarity and details across the image
  • Has technology been built into the system designed to reduce the effects of RF
  • 5 advanced imaging modes of fluorescence for visualization to accommodate multiple specialties all in 4K


      Light Source


Quantity: 6 EA


Specification/Salient Characteristics:


  • It has technology that is designed to increase patient and operating rooms safety by minimizing the amount of time the light source is on, making patient and drape burns less likely
  • Gives real time adjustments of light output to optimize visualization in every surgical scene
  • 2 infrared lasers for advanced imaging (fluorescence/lighted stents)
  • Gives visualize feedback to showcase when light cable is properly seated


      32” 4K Wireless Transmitter


Quantity: 4 EA


Specification/Salient Characteristics:


  • Wirelessly transmits 4K and 1080p signals
  • Improve safety and workflow efficiencies in the OR
  • Eliminate tripping hazards from cabling on the ground
  • Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options

     32” 4K Wireless Receiver


Quantity: 3 EA


Specification/Salient Characteristics:


  • Wirelessly receives 4K and 1080p signals
  • Improve safety and workflow efficiencies in the OR
  • Eliminate tripping hazards from cabling on the ground
  • Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options

   


      32” 4K OLED Surgical Display & Covers


Quantity: 11 EA


Specification/Salient Characteristics:


  • Resolution: 4096 x 2160
  • Size: 32” corner to corner
  • Ability to represent 1.07 billion different colors
  • Offers crisp contrast ratio of 1,000,000:1
  • OLED technology with self-illuminating pixels, eliminating the need for external backlighting
  • 0.1 ms response time for no detectable image lag
  • 14.0 lbs. for easy installation in both integrated and cart-based rooms
  • 9 preset surgical specialties
  • Includes 32" 4K OLED display covers


      OLED Surgical Display Cover


            Quantity: 11 EA


            Specifications/Salient Characteristics:


  • Intended to protect your displays from scratches/damage prolonging your investment
  • Easily removable for cleaning
  • Quick and seamless “install”
  • Highly durable


      Camera Head


            Quantity: 12 EA


            Specification/Salient Characteristics:


  • CMOS 3-Chip camera technology designed for enhanced light sensitivity and increased patient safety
  • Programmable to control OR equipment from camera head
  • Ergonomic lightweight design for minimally invasive surgery


      Insufflator


            Quantity: 6 EA


            Specifications/Salient Characteristics:


  • Enhances image clarity
  • For laparoscopic and robotic surgery
  • Removes surgical smoke for a safer work environment
  • 6 unique operating modes
  • All-inclusive system with integrated heating, humidification, and smoke evacuation capabilities
  • 4 interchangeable tube set options


      Light Cable


           Quantity: 12 EA


           Specifications/Salient Characteristics:


  • Scope sensing technology that automatically turns the light off when the scope is disconnected from the light cable
  • Fiber optic cable
  • Compatible Advanced Imaging modes
    • Fluorescence
    • Consistent lighting in small cavities
    • Auto light feature
    • Overlay mode to highlight ICG
    • Contrast mode

      Portable Handheld Fluorescence Imager


            Quantity: 1 EA


            Specifications/Salient Characteristics:


  • Intuitive operator controls
  • Comfortable single-handed operation
  • Indicated for fluorescence imaging of blood flow and tissue perfusion before, during, and after vascular, gastrointestinal, organ transplant, and plastic, microsurgical, and reconstructive surgical procedures
  • System is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes
  • 1080p x 60fps
  • Indicated for use in adult and pediatric patients one month of age and older
  • Combine enhanced fluorescence signal information with vivid white light images in real-time
  • 4 fluorescence modes for visualization
  • Software allows the surgeon to further evaluate the intensity of the fluorescence signal in real time through relative percentage values and a color maps mode
  • The ability to visualize lymphatic channels through the skin.


        Portable Handled Fluorescence Imager Video Processor


              Quantity: 1 EA


              Specifications/Salient Characteristics:


  • Features a timer that is automatically activated when fluorescence is detected, and icons indicating ingress and the fluorescence assessment window
  • Involves no ionizing radiation and utilizes a non-nephrotoxic fluorescence imaging agent with a very short half-life thus allowing surgeons to repeat intraoperative perfusion assessment numerous times throughout the procedure
  • The ability to visualize lymphatic channels through the skin.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 561421
New
Federal
Telephone Operator Support Services l KCVA | Base plus four (4) option years
Solicitation # 36C25526Q0654
The Department of Veterans Affairs Network Contracting Office has issued solicitation 36C25526Q0654 for a firm-fixed-price contract to provide 24/7 on-site telephone operator and telecommunications support services for the Kansas City VA Medical Center and its associated sites. This requirement is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561421. The contract structure consists of a base year starting October 1, 2026, with four optional extension years. The contractor is responsible for providing all personnel, management, and resources to handle internal and external call routing, emergency communications, alarm monitoring, and message delivery. Performance is measured against strict service levels, including an average speed of answer of 10 seconds or less, a maximum ring duration of 30 seconds, and an abandonment rate below 5 percent. Award decisions will be based on the most advantageous offer to the government, where non-price factors—specifically staffing and key personnel, the training plan, and quality review processes—are significantly more important than price. The contractor must adhere to rigorous security and privacy standards, including HIPAA compliance, VA cybersecurity directives, and personnel vetting. Invoicing is managed electronically through the Tungsten EIPP system, and performance is monitored via a Quality Assurance Surveillance Plan using a rating scale from Unacceptable to Superior.
Telephone Answering Services

POSTED

about 21 hours ago

DEADLINE

in 1 day
View Details
NAICS: 238210
New
Federal
H244--ME - TRANSFER SWITCH MAINT BASE PLUS 5 - CO (VA-26-00004264) 589-26-3-5329-0002
Solicitation # 36C255-26-AP-0031
The Department of Veterans Affairs, Network Contracting Office 15, has issued a Request for Information and Sources Sought notice to identify qualified small businesses for a full-service support agreement at the Harry S. Truman Memorial Veterans Hospital in Columbia, Missouri. The scope of work involves providing both scheduled preventive and unscheduled emergent maintenance for Automatic Transfer Switches, including ASCO, Zenith, and Metron equipment. All services must be performed by manufacturer-certified technicians in accordance with NFPA 110 standards and manufacturer specifications. The contract is structured as a base year with four option years, with an initial period of performance from September 25, 2026, to September 24, 2027. Key operational requirements include performing services Monday through Friday between 6:00 p.m. and 6:00 a.m. The contractor is responsible for providing all parts, labor, and travel, and must deliver electronic service reports within seven calendar days of completing work. Payment is contingent upon the submission of repair tickets signed by a VA representative. This is currently a planning phase and not a formal solicitation; interested sources must submit their capabilities and pricing information by September 17, 2026, at 10:00 a.m. Central Time.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

about 21 hours ago

DEADLINE

in 1 day
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS