This contract requires a Siemens technical representative to perform a comprehensive inspection, troubleshooting, and repair of the fire alarm control panel and detectors aboard the USCGC Healy at USCG Base Seattle. The primary objective is to resolve persistent trouble alarms, including communication errors and input source malfunctions, and to program newly installed detector heads into the FireFinder XLS system. The scope includes verifying the functionality of the master control panel and various annunciators, conducting functional tests on restored detectors, and providing a detailed inspection report and a comprehensive detector list. The period of performance is three working days within fourteen calendar days of the contract award. While the base scope covers the system groom and programming, a separate line item allows for potential additional repairs up to 2,500 dollars, subject to a Condition Found Report and written authorization from the Contracting Officer. All services must be performed in accordance with specific Coast Guard drawings and existing operation manuals to ensure the system is returned to a normal operating state.

General Info

Siemens will repair and program USCGC Healy fire alarm systems at Base Seattle.

Agency

Department Of Homeland Security → Sflc Procurement Branch 2(00085)View Agency

NAICS

336611 - Ship Building and RepairingView NAICS

Place of Performance

Seattle, WA, 98134, USA

Set-Aside

SBA

Documents

(1)

Healy+Fire+Alarm+Solicitation+SOW+%28002%29.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseCombined Synopsis
Posted

Combined Synopsis

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Sflc Procurement Branch 2(00085)
Contacts2 people available
OfficeALAMEDA, CA, 94501, USA
Organization / Agency
Department Of Homeland Security → Sflc Procurement Branch 2(00085)
View Agency Profile
Office AddressALAMEDA, CA, 94501, USA

Full Description

Show more

Statement of Work SIEMENS Fire Alarm System Troubleshooting USCGC Healy
1. GENERAL
1.1 Background The objective of this project is to perform a comprehensive inspection and repair of the existing fire alarm control panel and detectors onboard CGC HEALY. The contractor must perform a groom of the system to resolve insistent trouble alarms. The contractor must be a Siemens technical representative with ability to program newly installed detector heads into system. 1.2 Period of Performance The period of performance is fourteen (14) calendar days from date of contract award for three (3) working days. All work to be done onboard CGC HEALY at USCG Base Seattle Terminal 46. 1.3 Delivery Location Services to be performed at: USCG Base Seattle 1519 Alaskan Way S Seattle, WA 98123 POC: LT Stephen Bruno 1.4 References
•Coast Guard Drawing 420-WAGB-801-001, Rev K, Booklet of General Drawings•ALARMCO, INC Operation and Maintenance Manual
2. SCOPE OF WORK CLIN 0001:The contractor must provide all labor, materials, tools, and equipment necessary to complete the following tasks: 2.1 Clearing Alarms and Troubleshooting
•Review and document the panel's event log to identify the source of all current and historical faults, troubles, and alarm signals.


•Troubleshoot constant “Input source malfunction”, “Not Responding”, and“Communication Error” alarms that populate on FireFinder XLS Fire AlarmControl Panel.•Clear and reset all active alarms and trouble codes on the panel to return thesystem to a "Normal" operating state.
2.2 Program Detectors
•Restore full capability to all fire alarm units onboard with the exception of thosehoused in Generator Room 2 (1-80-2-E).•Program unidentified detector heads into the system including those recentlyinstalled HFP-11 smoke detectors in the Magazine Compartment (1-9-2-M).•Conduct functional tests on the restored detectors to verify proper activationand comunication with the Fire Alarm Control Panel.
2.3 Fire Alarm Panel Inspection
•Ensure Master Fire Alarm Control Panel in the Engineering Control Center andannunciators in Damage Control Central, and the Port and StarboardQuarterdecks are working with full button functionality. See Coast Guard Drawing420-WAGB-801-001 for guidance about the location of the spaces listed above.
3.DELIVERABLES3.1 Inspection Report A detailed inspection report to the US Coast Guard outlining findings of inspection, what repairs were conducted, which units need further work and the final result of system groom. Shall include documentation stating that the fire alarm panel and associated detectors have been restored to full functionality, or if full functionality has not been restored, include a list of specific repairs necessary to restore full functionality, including parts and necessary labor hours. 4. CLIN 002: Potential Repairs based on CFR not to exceed ($2,500 dollars)4.1 Pricing for any additional travel costs, material, or field service days will be requested and handled by the KO under the terms of the contract. Any repairs beyond the base scope identified because of the troubleshooting shall be documented in a Condition Found Report (CFR) with a technical description of the recommended repairs. The CFR shall be provided to the Technical POCs and the Contracting Officer. 4.2 Any additional work will be authorized only by the KO through a written contract modification. The contractor shall not perform any repairs beyond the base scope until specifically authorized in writing by the KO. If the Government elects to proceed with additional repairs, the KO will issue a written contract modification that identifies the authorized additional work and associated firm fixed price. The 5. Detector List Provide a table of all detectors, including at a minimum: •Detector Name•Network Address•Loop•Compartment location ofAn example table format is provided below. Reference current ALARMCO, INC Operation and Maintenance Manual created during the previous Fire & Smoke Detection Replacement Project under Contract No. HSCG40-12-S-30014.
Detector Name
Network Address
Loop
Compartment
Gen Rm 1 FWD
002:115
2
1-80-1-E
...
...
...
...

Similar Contracts

Same NAICS industry code

NAICS: 336611
New
DIBBS
BLADE SET, WINDSHIEL
Solicitation # SPE7M4-26-T-422S
This solicitation, issued by the DLA Land and Maritime Fluid Handling Division under number SPE7M4-26-T-422S, is a Request for Quotations for 303 windshield blade sets, identified by NSN 2090-01-692-4274. The procurement is categorized under NAICS code 336611, and the required delivery date is July 10, 2027, with a 284-day delivery window. The items are to be delivered to the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. Inspection and acceptance will both occur at the destination, and the contractor is required to use the Wide Area WorkFlow system for electronic invoicing and payment processing. The contract includes stringent technical, quality, and environmental compliance requirements. Specifically, the use of Class I ozone-depleting substances is prohibited, and mercury or mercury-containing compounds must not be intentionally added to any hardware. Packaging must adhere to ASTM D3951, though the DLA Master List of Technical and Quality Requirements takes precedence, and all marking and labeling must comply with MIL-STD-129. Furthermore, the contract incorporates several federal regulations, including the Buy American Act, the Berry Amendment, and cybersecurity safeguarding requirements under DFARS 252.204-7012. Offerors must submit their quotes through the DIBBS portal and are encouraged to provide quantity ranges to facilitate procurement flexibility.
FLUID HANDLING DIVISION

POSTED

about 17 hours ago

DEADLINE

in 10 days
View Details
NAICS: 336611
New
Federal
Maintenance, Repair, and Preservation of YRBM-50
Solicitation # N4523A26R1002
The Puget Sound Naval Shipyard and Intermediate Maintenance Facility intends to award a stand-alone Firm-Fixed-Price contract for the maintenance, repair, and preservation of the YRBM-50. This 100 percent Small Business set-aside under NAICS 336611 requires the contractor to provide a facility located in the Puget Sound, Washington region, specifically between Olympia and Bellingham. The vessel availability is scheduled from March 31, 2027, through March 31, 2028. The contractor is responsible for transporting the vessel from the government facility in Bremerton to their repair site and returning it upon completion. The scope of work includes comprehensive hull and structural repairs, such as ultrasonic plating thickness measurements, zinc anode replacement, and blast and paint preservation of the hull, freeboard, exterior decks, and superstructure. Key modifications involve installing a hot water heater, replacing the awning and A/C plant, and upgrading the switchboard, 1MC, phone, and CCTV systems. Additionally, the contractor must maintain and preserve 24 ballast tanks and voids, disinfect the potable water system, and perform dock trials. Deliverables include redline drawings and extensive quality evidence reports. The contractor must also provide a dedicated government facility for the supervisor and adhere to strict safety and environmental regulations, including 29 CFR standards.
Puget Sound Naval Shipyard IMF

POSTED

about 22 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 336611
New
Federal
Dock-Side (DS): CGC RESOLUTE DS FY27
Solicitation # 70Z08026QMECP0026
The USCGC RESOLUTE FY27 Aviation Availability contract, solicitation number 70Z08026QMECP0026, is a total small business set-aside for dockside repairs to the USCGC RESOLUTE (WMEC 620). The period of performance is scheduled from January 26 to February 24, 2027, with work performed in Portsmouth, Virginia. The scope of work includes eight primary technical items: load testing for 28 VDC and 400 Hz power supplies, removal and reinstallation of the anemometer windspeed transmitter, calibration of the aviation fuel flow meter, inspection and testing of helo talon grids, renewal of electrical stuffing tubes, and preservation of helicopter operating area decks. All preservation work must adhere to SFLC Std Spec 6310 and MIL-PRF standards, with specific requirements for surface profile measurements and soluble salt conductivity testing. The contract is administered by the Sflc Procurement Branch 1 under the Department of Homeland Security. Award evaluation is based on technical capability, corporate experience with DOD or USCG vessels within the last three years, and past performance. Contractors must provide proof of workers compensation insurance and utilize SSPC-QP 1 certified companies or NACE CIP Level 3 representatives for critical preservation. Payment is processed electronically via the Invoice Processing Platform based on the percentage or stage of completion. The pricing structure includes definite item CLINs, travel and per diem, and provisions for over-and-above growth labor and material markups.
Sflc Procurement Branch 1(00080)

POSTED

about 22 hours ago

DEADLINE

in 13 days
View Details
NAICS: 336611
New
Federal
CGC BEAR FUEL TANK CLEANING
Solicitation # 52000QR260028624
Request for Quotation 52000QR260028624 is a total small business set-aside for the cleaning and inspection of fuel oil tanks aboard the USCGC BEAR (WMEC-901) in Portsmouth, Virginia. This procurement is processed under FAR Part 12 and FAR 13 using simplified acquisition procedures on a firm-fixed price basis. Due to unusual and compelling urgency to ensure safety and mission readiness, the solicitation has an abbreviated response period with quotations due by September 18, 2026, at 12:00 P.M. Eastern Standard Time. The required period of performance is from September 21 to September 24, 2026, and shall not exceed four days. The scope of work includes removing tank covers, cleaning interior surfaces of all foreign materials such as sediment, sludge, and rust, and performing post-repair operational testing on tank TLIs and vent check valves. Contractors must provide a detailed cost breakdown, product data sheets, and warranty information on company letterhead. Key technical requirements include the use of AMS-C-6183 conforming gasket material, 100 percent renewal of nuts and washers, and the maintenance of a written plug log. All waste disposal must comply with federal, state, and local laws, and a complete chain of custody record for removed contents must be submitted to the Contracting Officer's Representative. Certain technical data and drawings are marked Distribution Statement D and are export-controlled. To access this restricted information, vendors must possess an active United States/Canada Joint Certification Program (JCP) certification. Award will be made to the responsible contractor offering the best value to the government, considering price, specifications, past performance, and quality. All offerors must be registered in the System for Award Management (SAM.gov) with an active Unique Entity Identifier.
Sflc Procurement Branch 1(00080)

POSTED

about 22 hours ago

DEADLINE

in about 6 hours
View Details
NAICS: 336611
New
Federal
USNS LARAMIE (T-AO 203) MTA
Solicitation # N3220526R6058
The solicitation N3220526R6058 for the USNS LARAMIE (T-AO 203) MTA is a Total Small Business Set-Aside under FAR 19.5, exclusively available to small businesses operating under NAICS code 336611, and is being managed by the Mschq Norfolk office of the Department of Defense located in Norfolk, Virginia. The procurement involves a revised scope of technical work that includes updates to existing work items 1073, 0104, 0105, 0168B, 0173B, 0561A, and 0669, the addition of new work items 1071 and 0025, and the removal of work item 0165, all incorporating RFCs 17-54. Access to sensitive technical data and software related to the vessel is governed by a mandatory Technical Non-Disclosure Agreement (J-14), which requires execution by a corporate principal and imposes strict limitations on use, restricted solely to proposal preparation and contract performance. Technical data must comply with DoDI 5230.24 and, where applicable, DoD-M 5200.01-V4 for controlled unclassified information. Any subcontractor engagement necessitates a flow-down NDA with identified corporate principals and contact information provided. All technical data must be returned or destroyed by shredding upon award to another entity or upon contract completion, with written certification submitted to the Contracting Officer within 30 days. Compliance with organizational controls to prevent unauthorized disclosure and adherence to export regulations are mandatory. The response deadline is May 29, 2026, at 1:00 PM EST, with proposals required to reference the solicitation and amendment numbers. No evaluation factors, pricing details, delivery locations, inspection criteria, or contract administration data are provided in the available materials, and the estimated contract value remains unspecified. Business CAGE codes are required, and submissions must be made via letter or electronic communication to the designated point of contact, with late or unacknowledged offers subject to rejection.
Mschq Norfolk

POSTED

about 22 hours ago

DEADLINE

in 6 days
View Details
NAICS: 336611
New
Federal
Dockside (DS): USCGC MIDGETT FY27 Repair
Solicitation # 70Z08526QLREP0024
Solicitation 70Z08526QLREP0024 is a firm-fixed-price commercial services procurement for the Fiscal Year 2027 second quarter dockside repairs of the USCGC MIDGETT (WMSL 757). The work is to be performed at 400 Sand Island Pkwy in Honolulu, Hawaii, with a primary performance period from February 2 through May 8, 2027. This acquisition is 100% set aside for small business concerns under NAICS code 336611. The scope of work includes 26 specific repair and inspection tasks, such as tank cleaning and preservation, fire prevention, refrigeration plant grooming, and various equipment renewals and installations. The government will award the contract based on a best value trade-off, prioritizing technical capability and past performance significantly over price. Offerors must submit a comprehensive quote including a one-page cover letter, a detailed price schedule in both Excel and PDF formats, a graphical planning document such as a Gantt chart, and past performance questionnaires for up to three relevant contracts. Key administrative requirements include the submission of a Department of Homeland Security Non-Disclosure Agreement and adherence to SFLC standard specifications for preservation and quality control. Following Amendment 0002, the deadline for receipt of quotes was extended to September 29, 2026, at 10:00 am Pacific Time.
Sflc Procurement Branch 2(00085)

POSTED

about 22 hours ago

DEADLINE

in 17 days
View Details

More opportunities from Department Of Homeland Security → Sflc Procurement Branch 2(00085)

Same awarding agency

NAICS: 238220
New
Federal
CGC POLAR STAR PUMP PARTS
Solicitation # POLARSTAR_PUMPPARTS_14501PR260000174
The United States Coast Guard is soliciting proposals for a firm fixed-price contract to procure critical spare parts for the Buffalo Pumps ancillary seawater cooling pumps installed on the CGC Polar Star. These parts, which include items such as wear ring casings, covers, and mechanical seals, are essential for maintaining ship readiness ahead of a scheduled deployment to Antarctica. The requirement specifically targets compatibility with Buffalo pump models AA6CCRE (motor M22H0628RE) and 709CCRE (motor M22H0631RE). Offerors must provide new, unused parts and must submit sufficient documentation, such as OEM part numbers or certifications, to verify compatibility. Additionally, any components that are not domestic end products must be identified with their country of origin, as the procurement is subject to the Buy American Act and other domestic preference requirements. Proposals must be submitted no later than 1200 Pacific Time on 10 October 2026. All required parts must be delivered to USCG Base Seattle no later than 01 November 2026, with the vendor responsible for all delivery costs. Delivery personnel must possess a Real ID to access the facility. Offerors are required to be registered in the System for Award Management (SAM) and must provide verifiable OEM lead times if standard delivery exceeds the required date. This procurement is not a small business set-aside. Payment will be processed via electronic funds transfer through SAM.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 22 hours ago

DEADLINE

in 11 days
View Details
NAICS: 811310
New
Federal
Open, Inspect, Repair Cylinder Assy.
Solicitation # 70Z08526P49025B00
The United States Coast Guard Surface Forces Logistics Center is soliciting quotes for a total small business set-aside contract to open, inspect, and overhaul three cylinder assemblies (NSN 3040-01-422-6785, Part CY5777) manufactured by HIS Corp. This is a competitive Firm Fixed Price purchase order to be awarded on a Best Value trade-off basis. The contractor must perform the overhaul in accordance with OEM procedures and Specification R-580-2037, ensuring the final product is equivalent to a new hydraulic cylinder using only new OEM replacement parts. Key deliverables include a Condition Found Report with a detailed cost estimate submitted within ten days of receipt, comprehensive digital photo documentation, and documented test results for stroke length and leakage. The required delivery date is November 14, 2026, with shipping set as FOB Destination to the Surface Forces Logistics Center in Baltimore, Maryland. Technical evaluation will focus on the vendor's ability to meet the delivery schedule, compliance with strict preservation, packaging, and marking standards (including MIL-STD-129R and MIL-PRF-131K), and documented experience with similar repairs. Vendors must maintain an inspection system conforming to ASQ Q90001-2008 and a NIST-traceable calibration program. All invoicing must be processed through the IPP portal with NET 30 payment terms. To be considered, vendors must have an active SAM.gov registration and provide a summary of previous projects of comparable scope and complexity.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

about 22 hours ago

DEADLINE

in 3 days
View Details
NAICS: 332321
New
Federal
USCGC HEALY Replacement Hangar Doors
Solicitation # 70Z08526SSNHEALYDOORS
The United States Coast Guard issued Request for Information 70Z08526SSNHEALYDOORS to identify capable manufacturers for a pair of replacement hangar doors, tracks, and operators for the USCGC HEALY. The required system must completely fill a 17 foot by 18 foot opening, accommodate the transit of an H-60 helicopter with folding rotor and tail variants, and be capable of operating in Arctic conditions. Technical requirements include compliance with NAVAIR Certification and MIL-DTL-24151 Type 1 Class 1 standards, with specific exceptions noted for sections 3.4.2.5, 3.4.2.6, and 3.4.2.11. Interested respondents must provide details on their engineering and manufacturing capabilities, including a history of similar doors produced within the last five years, proposed materials for slats and tracks, operator specifications, and methods for sealing against light and water. While the supplier is not responsible for the actual installation, they must provide technical representatives capable of traveling within the Continental United States to offer installation assistance. Responses must be submitted in PDF format to the designated points of contact by September 30, 2026. This RFI is for market research and planning purposes under FAR Part 10 and does not constitute a formal request for proposal or a guarantee of future procurement.
Metal Window and Door Manufacturing

POSTED

2 days ago

DEADLINE

in 12 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS