Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on February 19, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4130--Campus Energy Management System Pre-Solicitation Notice

Closed
36C24626B0018Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a subcontracting opportunity to perform multi-building plumbing leak repairs at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Harris Hall dormitory rooms 123 and 213, repairing a cracked drain pipe in the pipe chase of room 216, and replacing heat pipe sections in the Administration Building and King Hall. All work must comply with the Massachusetts State Plumbing Code, International Plumbing Code, OSHA regulations, and NFPA Standard No. 101. Contractors are responsible for all cutting, patching, and debris removal, and must provide a signed punch list and applicable warranties to close the project and receive payment. Interested bidders must submit a detailed quote by October 30, 2026, including a comprehensive cost breakdown of labor and materials, a proposed service schedule, and a quote validity period of at least 60 days. Required administrative documentation includes a SAM.gov UEI number, active registration, W-9, business licenses, Massachusetts professional credentials, and certificates of insurance. Award selection is not based solely on the lowest price; ETR will evaluate cost, qualifications, and administrative compliance. The contract is subject to various federal regulations, including the Davis-Bacon Act, the Service Contract Act, and FAR clauses regarding debarment and system for award management. Depending on the final project value, payment and performance bonds may be required for amounts exceeding 35,000 dollars.
Westover Job Corps Center

POSTED

40 minutes ago

DEADLINE

in 8 days
NAICS: 238220
New
MI 2026-14 Emergency Heating and Air Conditioning Services
Solicitation # MI 2026-14
Adams and Associates, Inc., contracting for the U.S. Department of Labor, is soliciting bids for emergency heating and air conditioning (HVAC) services at the Miami Job Corps Center in Miami, Florida. The period of performance runs from November 1, 2026, to October 31, 2027. This solicitation is set aside for small businesses, including certified Veteran, Service-Disabled Veteran, Women-Owned, and HUBZone small businesses. The selected vendor will be responsible for emergency HVAC repairs, with a requirement to provide separate hourly rates for non-emergency daytime services and emergency or weekend services. Eligible bidders must possess a valid Unique Entity ID (UEI) and maintain active registration in SAM.gov. Required submission documents include a written bid on company letterhead valid for 90 days, a vendor questionnaire, W9, Authority to Commit, a list of references, and all necessary business and employee licenses for the State of Florida. Vendors must also provide proof of Workers Compensation, Automobile Liability, and Comprehensive General Liability insurance of at least $1,000,000 per occurrence, naming Adams and Associates, Inc. as an additional insured. The contract is subject to the Service Contract Act and Davis-Bacon Act, specifically Wage Determination No. 2005-2248, with a minimum wage of $13.65 per hour for covered workers through December 31, 2026. Payroll and time cards must be submitted for any service incident exceeding $2,500. Award decisions will be based on the most responsible bidder, considering cost, licensure, and experience. Payment terms are NET 30 days from the date of invoice. All bids must be submitted to the Purchasing Department by October 23, 2026.
Miami Job Corps Center

POSTED

40 minutes ago

DEADLINE

in 1 day
NAICS: 238220
New
CBP6585 Bldg. 22 HVAC Replacement
Solicitation # CBP6585
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum subcontract to replace the HVAC system in Building 22 at the San Diego Job Corps Center in Imperial Beach, California. The scope of work requires the contractor to provide all labor, materials, and equipment to remove and dispose of existing units and install one new 5-ton condenser, one compatible furnace, and one 5-ton evaporator coil, including all necessary refrigerant. The estimated price range for this project is between 0 and 25,000 dollars. Bids are due by October 28, 2026, and must be submitted via email to Tom Williams. To be considered, bidders must conduct a physical site visit, sign an attendance roster, and provide a detailed cost breakout on company letterhead, proof of insurance, and three references. This opportunity is set aside for small businesses under NAICS code 238220. Award decisions will be based on overall best value. Contractors must comply with the Davis-Bacon Act and applicable prevailing wage rates for San Diego County, as well as OSHA safety standards. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent is required at the time of submission, and performance and payment bonds of 100 percent of the contract price from an A-rated surety company are required upon award. Additional requirements include obtaining a Unique Entity Identification number, submitting an SF 1413 form, and adhering to various FAR clauses regarding small business utilization, foreign purchase restrictions, and labor standards. Payment will be made via progress payments based on percentage completion using AIA Document G702 and G703 forms.
San Diego Job Corps Center

POSTED

40 minutes ago

DEADLINE

in 7 days
NAICS: 238220
New
MJCC EXHAUST FANS BLD. 1429
Solicitation # mjcc-exhaust-fans-bld-1429
The Muhlenberg Job Corps Center, operated by Insights Training Group LLC, is soliciting fixed-price quotes from qualified HVAC and mechanical contractors to restore the exhaust fan and louver systems in Building 1429, located in Kentucky. The project scope involves comprehensive inspections and repairs for multiple units, including replacing motors and selector switches for fans 2 and 4, relocating a thermostat for fan 3, installing missing components for fan 5, verifying the operation of fan 6, and replacing a louver actuator for fan 7. Additionally, the contractor must perform system-wide replacements of aged thermostats, relays, and louver actuators while ensuring all work complies with applicable building codes, manufacturer requirements, and OSHA and EPA regulations. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Award will be granted to a single responsible offeror based on technical acceptability and the lowest price. The period of performance is 45 days from the date of award. Contractors must be registered in the State of Kentucky, provide proof of insurance, and demonstrate the ability to secure performance and payment bonding. Compliance with the Davis-Bacon Act is mandatory, requiring the submission of weekly certified payroll with every invoice. Quotes must be submitted electronically to mjccpurchasing@insightsllc.net by October 30, 2026, at 5:00 PM.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

40 minutes ago

DEADLINE

in 8 days
NAICS: 238220
New
Furnace Replacement
Solicitation # 26-17
Management and Training Corporation is soliciting bids for a lump sum contract to remove and replace furnaces and thermostats in three staff houses at the Tongue Point Job Corps Center in Astoria, Oregon. The project covers Quarters F (3,786 sq/ft, propane), Quarters P (1,100 sq/ft, natural gas), and Quarters Q (2,280 sq/ft, propane). Required equipment must be Carrier Comfort Series or an equivalent good grade with at least a 96 percent efficiency rating, sized at approximately 80,000 btu. Technical requirements include a lifetime warranty on the heat exchanger and a minimum 10 year warranty on parts. The estimated price range for the project is between 0 and 25,000 dollars. Bids are due by October 21, 2026, and must include a detailed cost breakout on company letterhead and be submitted to Elizabeth Williamson. Award decisions will be based on overall best value. The contract is set aside for small businesses and other socioeconomic categories, requiring a Unique Entity ID and self certification. Compliance with the Davis Bacon Act and Federal Contractor Minimum Wage is mandatory, with weekly certified payroll reports required. For bids equal to or greater than 25,000 dollars, a 20 percent bid bond and performance and payment bonds from an A minus rated surety are required. Final payment is contingent upon a final inspection, submission of a Notice of Final Completion, release of liens, and delivery of operation and maintenance manuals.
Tongue Point Job Corps

POSTED

40 minutes ago

DEADLINE

in about 4 hours
NAICS: 238220
New
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project focuses on eliminating severe piping leaks and replacing failing infrastructure in Building CM (Men's Dormitory), Building CW (Women's Dormitory), and Building D (Recreation). A licensed fire sprinkler contractor is required to demolish the existing distribution piping network and compressors, install a new code-approved piping network and properly sized air compressor, and perform rigorous operational and leak testing in accordance with NFPA 25 standards. The work must be completed within 30 consecutive business days following a written Notice to Proceed. Bids are due by December 1, 2026, and must include a detailed cost breakout and proof of insurance. A physical site visit and signature on the attendance roster are mandatory prerequisites for bid submission. For bids totaling $25,000 or more, a bid bond guarantee of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety. Award decisions will be based on overall best value and bidder responsiveness. The contract is subject to various federal regulations, including the Davis-Bacon Act, requiring compliance with prevailing wage rates for building construction in Idaho. Contractors must adhere to FAR clauses regarding small business utilization, whistleblower rights, and security requirements. Additionally, first-tier subcontractors with awards exceeding $45,000 must disclose debarment status per FAR 52.209-6, and contracts valued at $40,000 or more are subject to FFATA reporting. Final payment is contingent upon a successful substantial completion inspection and the submission of weekly certified payroll reports.
Management & Training Corporation/Centennial Job Corps Center

POSTED

40 minutes ago

DEADLINE

in about 1 month
NAICS: 238220
New
Dorm Hot Water Tank Replacement – Glenmont Job Corps Center – S26-006
Solicitation # S26-006
Adams and Associates, Inc. is seeking qualified mechanical and plumbing contractors for solicitation S26-006 to replace domestic hot water storage tanks and associated equipment at the Glenmont Job Corps Center in Glenmont, New York. The scope of work involves the removal and disposal of four existing 505-gallon tanks and the installation of four new 500-gallon insulated storage tanks, four new heat exchangers, and one bronze Bell and Gossett circulator pump in the North Dormitory. Additional requirements include piping modifications using ProPress materials, electrical work, insulation, rigging, and the provision of a temporary hot water heater to ensure the facility remains operational during the estimated construction period of two and a half to three weeks. This is a subcontracting opportunity rather than a direct federal procurement, though it requires compliance with Davis-Bacon prevailing wage requirements and New York State statutory insurance and licensing standards. Proposals are due by November 9, 2026, at 4:00 PM ET, following a site walkthrough on October 29, 2026. Award selection is based on a weighted evaluation of price (60 points), quality (20 points), past performance (10 points), and schedule (10 points), with the lowest price not guaranteeing an award. Required submission documents include company qualifications, business references, New York State licenses, certificates of insurance, a completed vendor questionnaire with UEI and NAICS code, and a current W-9. Payment terms are set at Net 30 days upon completion and receipt of invoice.
Adams and Associates, Inc.

POSTED

40 minutes ago

DEADLINE

in 19 days
NAICS: 238220
New
MJCC HVAC BLD. 1403-04 B HALL
Solicitation # mjcc-hvac-bld-1403-04-b-hall
Insights Training Group LLC, on behalf of the Muhlenberg Job Corps Center in Kentucky, is soliciting fixed-price quotes for an HVAC project at Building 1403-04 B Hall. The scope of work requires the contractor to provide all labor, materials, equipment, and supervision to install two 4-ton twinned split systems featuring Trane condensing units with a minimum 17 SEER rating and 95% AFUE high-efficiency gas furnaces using R-454B refrigerant. Additional requirements include the installation of high-efficiency evaporator coils, 2-inch filter racks, new refrigerant line sets, and condensate drain piping. The project must be completed within 45 days of award, and the contractor is responsible for all testing, inspections, and the provision of operating and maintenance manuals. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. To be considered technically acceptable, offerors must be registered and licensed in the State of Kentucky, verified through the SAM portal, and provide a minimum 90-day bid guarantee along with proof of ability to secure performance and payment bonding. Award will be granted to the responsible offeror with a technically acceptable quote and the lowest price. Compliance with the Davis-Bacon Act is mandatory, requiring the submission of weekly certified payroll and a signed Statement of Compliance with every invoice. All work must adhere to local codes, manufacturer specifications, and OSHA and EPA regulations, with a strict requirement for maintaining Materials Safety Data Sheets for all products used on site. Quotes are due by October 30, 2026.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

40 minutes ago

DEADLINE

in 8 days
NAICS: 238220
New
Roswell JCC – Male Dormitory Bldg. Water Source Heat Pump Replacement (20 units)
Solicitation # roswell-jcc-male-dormitory-bldg-water-source-heat-pump-replacement-20-units
The Career Systems Development Corporation is soliciting proposals for the replacement of twenty failed ceiling-mounted water source heat pumps at the Roswell Job Corps Center Male Dormitory Building 558 in New Mexico. The scope of work involves the removal of damaged units and the installation of twenty Bosch 1-ton units or an equivalent model. Additionally, the contractor must install smoke dampers with fusible links in all vents leading into the plenum and ensure all installed plenum materials are plenum rated. All work must comply with NFPA 101, NFPA 70, and applicable plumbing, mechanical, and building codes. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified firms. The project is subject to the Davis Bacon Act Wage Determination NM20260014, requiring the submission and approval of weekly certified payroll reports prior to invoice payment. Proposals exceeding 100,000 dollars require payment and performance bonding for 100 percent of the contract value upon award. Submissions must include a technical approach for safe completion, a detailed cost breakdown for labor and materials, equipment cut sheets, warranty information, and a proposed payment schedule. Final deliverables include the turnover of operation manuals to the Facility Manager upon project completion.
Career Systems Development Corporation

POSTED

40 minutes ago

DEADLINE

in 16 days
NAICS: 238220
New
WOJC – Buried Domestic Hot Water (DHW) Pipe Repair
Solicitation # wojc-buried-domestic-hot-water-dhw-pipe-repair-0
Education & Training Resources is seeking quotes for a fee-for-service subcontract to repair buried domestic hot water piping at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work involves the location, removal, and repair of compromised piping up to 4 inches in diameter, including excavation and insulation, at two specific locations: behind Singletary Hall and on the east side of Harris Hall. All work must adhere to industry standards, OSHA regulations, and the National Fire Protection Association Life Safety Code. The project requires a one-year equipment and workmanship warranty, and final payment is contingent upon a signed punch list and the submission of all warranties. Interested bidders must submit their proposals by 4:00 PM on November 6, 2026. A mandatory site walkthrough is scheduled for October 27, 2026, to ensure contractors are familiar with site conditions. Required submission documents include a completed bid sheet with a detailed cost breakdown, a proposed service schedule, Massachusetts licensing, certificates of insurance, a W-9, and a Vendor Acknowledgement Form. The winning contractor must possess an active SAM.gov registration and a Unique Entity ID. Additionally, the project mandates compliance with the Davis-Bacon Act or Service Contract Act, requiring the submission of weekly certified payroll reports. Depending on the final contract value, payment and performance bonds may be required for projects exceeding 35,000 dollars.
Westover Job Corps Center

POSTED

40 minutes ago

DEADLINE

in 15 days

AI Contract Overview

Show more

The Department of Veterans Affairs, through its Network Contracting Office 6, is conducting market research to identify potential contractors for a Campus Energy Management System construction project at the W. G. Hefner VA Medical Center in Salisbury, North Carolina. This sources sought notice is not a solicitation but seeks responses to better understand the market for providing comprehensive construction services, including labor, materials, equipment, and installation required to upgrade and integrate network and user interfaces with new Siemens Desigo control systems. The work involves replacing existing control systems and terminals, modifying network cabling and components, and ensuring compatibility with BACnet and Siemens systems. The project is anticipated to cost between $2 million and $5 million, with a performance period of 365 days from the notice to proceed, and falls under NAICS code 333415 with a size standard of 1,250 employees. The government encourages responses from all business sizes but has a preference to set aside the acquisition for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) or Veteran-Owned Small Businesses (VOSB) registered in the SBA VetCert database, provided there is sufficient competition and the pricing is fair and reasonable. Respondents are required to provide detailed company information, capability statements, and compliance with subcontracting limitations, as well as submit answers to specific questions regarding project timing, magnitude, and any potential barriers to bidding. Responses must be submitted electronically by the stated deadline, and no solicitation or request for quotations currently exists. This notice serves primarily as a means for the VA to gauge interest, capability, and market conditions ahead of any future formal procurement actions.

General Info

VA seeks contractors for $2-5M campus energy system upgrade, preference to SDVOSB/VOSB firms.

Contract Value

$4,682,337

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

VA

Set-Aside

NONE

Award Issued Date

Documents

6

IFB 36C24626B0018 Install Campus Emergency Management System Salisbury VA

PDF, High priority: read this first66 pages · ifb
High

VA Project 659-22-100 Campus Energy Management System Drawings

PDF, High priority: read this first71 pages · drawings
High

VA Project 659-22-100 Campus Energy Management System Specifications

PDF, High priority: read this first426 pages · specifications
High

36C24626B0018 Campus Energy Management System Pre-Solicitation Notice

DOCX, Low priority4 pages · presolicitation
Low

Contractors Request for Progress Payment Invoice

PDF, Low priority1 page · invoice
Low

Sources Sought Notice for Campus Energy Management System - 36C24626B0018

DOCX, Low priority4 pages · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Type Changed

Sources Sought → Presolicitation

Type Changed

Presolicitation → Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)
Contacts1 person available
OfficeHAMPTON, VA, 23667, USA
Office AddressHAMPTON, VA, 23667, USA
Contacts
Mark C GriffinContract Specialist

Full Description

Show more
W.G. (Bill) Hefner Department of Veterans Affairs Medical Center 1601 Brenner Avenue Salisbury, North Carolina 28144
Subject: Statement of Work: Install Campus Energy Management System Location: Campus Project #: 659-22-100 Date: 12 December 2025 STATEMENT OF WORK Mechanical General: The project involves the upgrade and consolidation of the Energy Management Systems (DDC) providers serving Buildings 2 on the Salisbury VAMC Campus. The new system will follow Native BACnet protocol and be able to replace existing JCI and Schneider components with a single front-end user interface compatible with Siemens. This project is to convert systems from both pneumatic controls and obsolete DDC controls to the Siemens Desigo Native BACnet central system, where applicable, for Buildings 2. This project should be completed in 365 days and include a 1 year warranty on all items.
SCOPE OF WORK:
The Scope of work associated with the project includes the following:
Network & User Interface
Appropriate modifications to the existing network and cabling layout (Ethernet & MSTP) for the purpose of integration, including the installation of new Desigo panels.
Terminal Unit Controls
1) Modifications required to replace the Tridium/Niagara controls with BACnet, Siemens Desigo compatible controllers and sensors (where required). Include in the recommendation, devices that can remain (relays, switches, valves, damper motors, sensors, etc.)
To include the following: (i) New Siemens server to replace the existing Siemens server. (ii) Front-End Graphical User Interface modifications, including new floor plans for every level of Buildings 2. (iii) Main equipment panel and controller installations. (iv) Panel installations. (v) Panel modifications and replacement, and controller replacements, required on the main systems. (vi) Ethernet-level networking modifications. (vii) BACnet MSTP networking modifications. (viii) Pneumatic terminal-unit controller replacements. (ix) Removal of the compressed air system serving control components and devices.
to include all hardware, software, installation, wiring, cabling, programming of systems, graphics, and setup of alarms, schedules and trending; as well as networking requirements required to into a new Siemens server in accordance with the VA standards.
Applicable Codes and Standards:
DVA HVAC Design Manual, March 2024 ASHRAE Standard 13 Specifying Building Automation Systems ASHRAE Standard 135 BACnet Communication Protocol IEEE 802.3 Standard for Ethernet NFPA 70 National Electrical Code
EXISTING CONDITIONS
Network Level
1) The existing Building Automation System (BAS) consists of three (3) separate vender systems: Siemens Desigo, JCI Metasys, and Schneider SmartStruxure. All three (3) headend systems and HMIs are in Building 31 chiller plant offices.
2) The internet modem for the Siemens system-to-remain is in Building 5, Room G048A.
Building 2
1) The Siemens Desigo system is currently communicating with most of the areas in Building 2. This control system will remain. The known areas under control by Siemens:
(i) Air handling unit 2-AHU-2 (ii) Air handling unit 2-AHU-3 (ongoing work) (iii) Air handling unit 2-AHU-4 (iv) Air handling unit 2-AHU-4B (v) Air handling unit 2-AHU-11 (vi) Chilled water pumps (vii) O.R. chillers (viii) 1st Floor isolation rooms (ix) 3rd Floor isolation rooms (x) 3rd Floor isolation EFs (xi) 3rd Floor hot water system (xii) 3rd Floor temperature zones (xiii) 4th Floor isolation rooms (xiv) 4th Floor isolation EFs (xv) 4th Floor temperature zones (xvi) 5th Floor isolation rooms (xvii) 5th Floor isolation EFs (xviii) 5th Floor temperature zones
2) The JCI Metasys system is active but has had some equipment migrated over to the Siemens system. The remaining known equipment/areas under JCI control:
(i) Air handling unit 2-AHU-1 (AHU-5 in the field) (ii) Air handling unit 2-AHU-7 (iii) Air handling unit 2-AHU-15 (iv) Air handling unit 2-AHU-16 (presently being migrated to Siemens) (v) Ground Floor exhaust fans (vi) Ground Floor hot water system (vii) Ground Floor temperature zones (viii) Ground Floor differential space pressure monitors (ix) 4th Floor isolation rooms
The Schneider SmartStruxure system contains the majority of the systems that are to be integrated into the Siemens Desigo system. The known equipment/areas under Schneider control:
(i) Air handling unit 2-AHU-X (ii) Air handling unit 2-AHU-6 (iii) Air handling unit 2-AHU-9 (iv) Air handling unit 2-AHU-10 (v) Air handling unit 2-AHU-12 (vi) Air handling unit 2-AHU-14 (vii) Air handling unit 2-RTU-1 (viii) Air handling unit 2-RTU-Cardiology (ix) Air handling unit 2-RTU-Lab (x) 3rd Floor hot water system (xi) 3rd Floor temperature zones (xii) Penthouse hot water systems (Qty 3) (xiii) Steam zone valves (Qty 6)
Survey items remaining for Building 2 scope of work:
(i) Field locations of JCI and Schneider network components for the purpose of developing demolition drawings (ii) Trace out any remaining pneumatic components associated with building automation (iii) Fan coil controls (iv) Temperature zones of the Ground, 1st, and 2nd Floors
DESIGN APPROACH
Network Level
1) A new server will be provided to replace the existing Siemens server. The server is in Building 31 chiller plant offices. Network Cabling from Building 5 will be re-used to connect to the new server.
2) The building 5 network switch that connects to the Siemens server and to the building #2 fiber network switch will remain in its existing configuration.
Building 2
1) The existing fiber network switch, located in the Ground Floor Mechanical Equipment Room G009 will be expanded with a CAT6 to a new network switch, located in the same room.
The new switch shall serve Ground Floor equipment, differential space pressure monitors, and temperature zone controls currently being served by the JCI system. It is anticipated that the existing JCI cabinet enclosures serving air handling units 2-AHU-5 and 2-AHU-15 can be re-used.
Existing air handling unit 2-AHU-5 will require pneumatic device change-out for the modulating outside air, return air, and relief air control dampers, 2-way cooling coil control valve, and supply and return airflow measuring devices.
The Schneider-controlled steam zone valves, associated sensors, and controller will be replaced and integrated into the Siemens system. The cabinet enclosure will need to be replaced. This work is expected to occur during the summer months.
The points connected to the additional Schneider I/O modules (4 total) in Mechanical Equipment Room G009 that are located in two (2) of the older cabinet enclosures, have yet to be identified.
2) The existing network switch located on the 3rd Floor, Room 3177 will either be expanded or replaced as needed to integrate the Schneider-controlled equipment on this floor. Currently, this switch has one (1) available port.
New CAT6 cabling will be installed in the ceiling space of the occupied 3rd Floor in order to connect the new Siemens controllers serving existing air handling units 2-AHU-X and 2-AHU-6, temperature zones, and hot water heat exchanger and pump set.
3) The existing network switch located on the 4th Floor, Room 4167 will remain asis. Currently, this switch is being used to replace rooftop equipment controls to existing air handling units 2-AHU-2 and 2-AHU-3, along with the dilution exhaust fans and miscellaneous points.
4) The existing network switch located on the 5th Floor, Room 5003 currently serves the rooftop chillers, air handling units, and occupied areas of the 4th and 5th Floors. The 5th Floor switch is intended to connect to the new Penthouse switch and to integrate the remaining JCI and Schneider-controlled equipment that are on the 5th Floor level (4th Floor roof included).
New CAT6 cabling will be installed in the ceiling space of the occupied 5th Floor in order to connect the new Siemens controllers serving existing air handling unit 2-AHU-4-OR, temperature zones, and hot water heat exchanger and pump set.
5) A new 24-port network switch will be installed in the Penthouse and will carry the bulk of the equipment being integrated into the Siemens system. Each CAT6 cable to the switch will be dedicated to each equipment controller. The new 24-port switch will have a network drop down to the existing 5th Floor network switch.
(i) Existing air handling unit 2-AHU-7 is currently under DDC control. The new Siemens controller shall replace the existing JCI controller in the same cabinet enclosure. (ii) Existing air handling unit 2-AHU-8 will require pneumatic device changeout for the 2-position outside air control damper, face-and-bypass steam preheat coil, and 3-way modulating cooling coil control valve. A new control cabinet enclosure will be installed for this unit. This will require extending device signal wiring. (iii) Existing air handling units 2-AHU-9 and 2-AHU-10 will require pneumatic device change-out for the 2-position outside air control damper, face-and-bypass steam preheat coil, 3-way modulating cooling coil control valve, and humidifier control valve. Devices associated with the humidifier will be new. They include a new discharge humidistat, discharge high-limit switch, and space humidistat. The existing cabinet enclosure can be re-used for these units. (iv) Existing air handling units 2-AHU-12 and 2-AHU-14 are currently under DDC control. The new Siemens controllers shall replace the existing Schneider/ Andover controllers. The existing 2-AHU-14 cabinet enclosure can be re-used, but 2-AHU-12 will need to be separated from the shared cabinet enclosure with 2-AHU-9. This will require extending device signal wiring for 2-AHU-12. (v) Existing air handling unit 2-AHU-13 will require pneumatic device change-out for the 2-position outside air control damper, steam preheat coil, and 2-way modulating cooling coil control valve. A new control cabinet enclosure will be installed for this unit. This will require extending device signal wiring. (vi) Existing air handling unit 2-RTU-1 will require pneumatic device changeout for the 2-position outside air control damper, modulating steam preheat coil control valve, 2-way modulating cooling coil control valve, modulating steam reheat coil control valve, and humidifier control valve. Devices associated with the humidifier will be new. They include a new discharge humidistat, discharge high-limit switch, and return air ductmounted humidistat. A new control cabinet enclosure will be installed for this unit. This will require extending device signal wiring. (vii) Existing heating hot water systems, exhaust fans, and other miscellaneous points in the Penthouse are expected to be housed in three (3) new cabinet enclosures. This will require extending device signal wiring.
Programming for the sequences of operation and graphics mapping will be required for all equipment associated with work in Building 2. New programming will utilize existing, new, and change-over devices and therefore, will only meet ASHRAE 36 guidelines for high-performance sequences of operation where such devices already exist. For example, using AHU static pressure reset by poling VAV box damper positions.
Testing, Adjusting, and Balancing Contractor will be required to calibrate new airflow measuring devices and to calibrate the feedback from existing VAV boxes.
Electrical
GENERAL
The project involves the upgrade and consolidation of the Energy Management Systems (DDC) providers serving Buildings 2 on the Salisbury VAMC Campus. The new system will follow Native BACnet protocol and be able to replace existing JCI and Schneider components with a single front-end user interface compatible with Siemens. This project is to convert systems from both pneumatic controls and obsolete DDC controls to the Siemens Desigo Native BACnet central system, where applicable, for Buildings 2.
SCOPE OF WORK The following systems will be modified to suit the electrical demands of the project:
Normal Electrical Distribution at 208/120-volts Emergency Electrical Distribution at 208/120-volts Lighting systems and controls
B. The electrical design shall be in accordance with, but not limited to the following VA design standards:
VA Electrical Design Manual for New Hospitals, Replacement Hospitals, Ambulatory Care, Clinical Additions, Energy Centers, Outpatient Clinics, Animal Research Facilities, and Laboratory Buildings. NFPA 70 National Electrical Code National Fire Protection Association (NFPA) Standard 101 Life Safety Code
EXISTING CONDITIONS
Power
1) Emergency life safety and critical power branch panels are located on every floor of the building. The majority of the panels have spare circuit breakers or spaces to add a new circuit breaker as required.
DESIGN APPROACH
Power and Lighting
1) The intent of the design shall be to install new BAS panels adjacent to the existing outdated panels. Generally it was impossible to trace the power source of the existing BAS panel, therefore new 120-volt emergency branch circuit shall be routed to the new BAS network controller panel power supplies. This is required by VA standards. 2) Additionally, new network switches shall be installed in various locations throughout the three buildings. Local emergency 120-volt emergency branch circuits shall be provided for network switches as shown on drawings. 3) Where necessary, existing lighting and other ceiling mounted electrical devices shall be taken down and reinstalled in the same location during the course of the construction. 4) The circuits for all mechanical equipment, which have been scheduled for demolition, shall be removed back to the source.
Equipment Grounding and Wiring Devices
1) In general, 20-amp duplex receptacles will be located where required. All receptacles shall be hospital-grade, plug-tail type receptacles complying with NEC Art. 517.13(B). 2) All non-current carrying metallic parts of the electrical distribution system will be bonded to the grounding electrode system or building steel. 3) An insulated grounding conductor will be run with all power feeder and branch circuits to supplement the conduit ground. 4) All wiring shall be solid for wire #10 and smaller and stranded for wires larger than #10. 5) Nonflexible metallic conduit will be provided for all emergency circuits due to the need to provide redundant grounding and protection of the branch circuit. Metal-Clad cabling, Type MC, will be permitted for branch circuit wiring where concealed within partitions and above ceilings for lighting fixtures. In addition, liquid-tight flexible metal conduit will be used at motor and other vibration transmissive locations.
Contractor Trades: Mechanical Contractor Coordinate with the controls contractor to ensure seamless HVAC equipment interface and integration. Modify or relocate existing mechanical systems as needed to accommodate new control infrastructure. Provide support during system commissioning, functional performance testing, and final acceptance. Ensure all mechanical work complies with VA HVAC standards and ASHRAE guidelines. Qualifications: Licensed mechanical contractor with experience in healthcare environments. Familiarity with Siemens Desigo systems and BACnet protocol preferred. Controls Contractor (Siemens Certified) Install and program Siemens Desigo BACnet control systems, including hardware and software components. Replace existing pneumatic and outdated DDC controls with modern digital systems. Integrate HVAC equipment into the new Energy Management System (EMS). Conduct full commissioning, calibration, and validation of control systems. Provide end-user training and documentation for system operation and maintenance. Qualifications: Siemens-certified technician or firm with demonstrated experience in federal or VA projects. Must comply with VA cybersecurity and interoperability standards. Electrical Contractor Provide dedicated power supply to Siemens control cabinets and associated network switches. Remove and dispose of obsolete electrical components (e.g., Johnson Controls, Schneider Electric). Install new branch circuits, electrical panels, and conduit routing per NEC and VA specifications. Coordinate electrical shutdowns and temporary power solutions to maintain facility operations. Perform firestopping and patching of all penetrations created during electrical work. Qualifications: Licensed electrician with experience in hospital or healthcare facility electrical systems. Must be familiar with VA electrical safety protocols and infection control procedures. Low Voltage / Communications Contractor Install CAT6 or higher-rated network cabling for control panels, switches, and EMS components. Terminate and test all cable runs to ensure compliance with VA telecom standards. Coordinate with VA IT department for switch integration and IP address assignments. Label and document all cabling and connections for future maintenance. Qualifications: BICSI-certified technician or equivalent. Experience with VA telecom infrastructure and patch panel standards. General Contractor Provide overall coordination and scheduling of all subcontracted trades. Manage ceiling removal and replacement as indicated in demolition and construction plans. Perform wall patching, painting, and restoration following electrical and control installations. Develop phasing plans to minimize disruption to patient care and facility operations. Ensure infection control measures are in place during construction activities. Qualifications: Licensed general contractor with experience in VA or federal healthcare construction. Must comply with VA Interim Life Safety Measures (ILSM) and infection control protocols. Firestopping Contractor Seal all penetrations through rated walls and floors created during conduit and cable installations. Use UL-listed firestopping materials and methods. Ensure compliance with NFPA 101, VA standards, and local fire codes. Qualifications: Certified firestopping technician. Experience in healthcare facility fire barrier restoration. Commissioning Agent (CxA) Verify that all installed systems meet the design intent and operational requirements. Conduct functional performance testing and provide commissioning reports. Coordinate with VA stakeholders for final acceptance and turnover. Qualifications: Independent third-party CxA with experience in VA commissioning protocols. Must be familiar with ASHRAE Guideline 0 and VA Cx standards.

More opportunities from Department Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)

Same awarding agency

NAICS: 562111
New
Federal
S205--Solid Waste Disposal Services Salem VAMC
Solicitation # 36C24627Q0046
The Department of Veterans Affairs is soliciting quotes for solid waste and recyclable materials removal services at the Salem VA Medical Center in Salem, Virginia. This SDVOSB set-aside contract involves the lease, maintenance, and operation of various 20 and 30 cubic yard fire-retardant storage containers across multiple buildings. The period of performance consists of a base year starting December 10, 2026, with four one-year options to extend. The contractor is required to provide an onsite representative to oversee operations and conduct initial and quarterly site waste assessments. All services must comply with OSHA, EPA, and local laws, with specific requirements for monthly steam-cleaning of metal compactor containers and strict adherence to VA sensitive information and security protocols. Award will be based on the best value offer, evaluating technical and management approach, capability to perform, a detailed staffing plan, and past performance within the last three years. Performance will be monitored via a Quality Assurance Surveillance Plan using random inspections and monthly comparisons against acceptable quality levels ranging from 95% to 100%. Quoters must be verified Service-Disabled Veteran-Owned Small Businesses and comply with limitations on subcontracting, ensuring no more than 50% of the work is performed by non-SDVOSB or non-VOSB firms. Invoices must be submitted electronically, and all personnel accessing sensitive areas may be subject to Tier 3 or Tier 5 security investigations.
Solid Waste Collection

POSTED

about 5 hours ago

DEADLINE

in 8 days
View Details
NAICS: 238220
New
Federal
4120--RENTAL OF TWO CHILLERS FOR ONE YEAR
Solicitation # 36C24627Q0086
The Department of Veterans Affairs, Network Contracting Office 6, is soliciting a firm-fixed-price contract for the rental of two 400-ton low-temperature air-cooled chillers to provide uninterrupted cooling services at the Charles George VA Medical Center in Asheville, North Carolina. The period of performance is scheduled from December 11, 2026, to December 10, 2027. These temporary units are required to maintain appropriate temperatures in Building 15 and Building 47 while permanent repairs and replacements are executed. The contractor is responsible for the delivery, installation, and regular maintenance of the equipment, including the submission of monthly maintenance reports and the immediate resolution of any malfunctions. This procurement is a total set-aside for verified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238220. Award evaluation is based on technical capability, past performance within the last three years, and price. Technical evaluations focus on the contractor's ability to comply with HIPAA, VA criteria, NFPA, OSHA, and local building codes, as well as the quality of their contingency plans. Quotes must be submitted via email to the contracting officer by October 30, 2026, and must include a signed SF 1449, a pricing schedule, and a completed VAAR 852.219-76 certificate of compliance. Payment will be processed monthly in arrears through the VA Financial Services Center via electronic funds transfer.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 237110
New
Federal
Z2NZ-- 658-23-108 Correct Stormwater Drainage
Solicitation # 36C24626B0031
Project 658-23-108 is a sealed bidding construction project for the Department of Veterans Affairs to correct stormwater drainage at the Salem VA Medical Center in Salem, Virginia. The scope of work includes providing all labor, materials, equipment, and supervision to install outside storm sewer systems and underground water distribution for domestic and fire supply systems, including piping and structures. The estimated magnitude of construction is between $10,000,000 and $20,000,000, with a performance period of 450 calendar days from the issuance of the Notice to Proceed. This contract is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 237110. The prime contractor must be a certified SDVOSB and is required to perform at least 15% of the construction work. Key personnel requirements include a dedicated full-time Superintendent, a CQC System Manager, and an SSHO. Bidders must have completed three projects of similar complexity and value within the last three years and must not have serious EPA or OSHA asbestos violations in that same timeframe. The procurement follows FAR Part 14 Sealed Bidding procedures. Bidders must be registered in the System for Award Management (SAM) and provide a bid guarantee of at least 20% of the bid price, capped at $3,000,000. Technical requirements include compliance with the 2010 MEP Correction Code, ADA accessibility standards, and EPA quality standards. Final acceptance is contingent upon a formal inspection, and the contractor must submit a Quality Control Plan at least two business days prior to the coordination meeting.
Water and Sewer Line and Related Structures Construction

POSTED

1 day ago

DEADLINE

in 20 days
View Details
NAICS: 623220
New
Federal
Q402--Medical Respite Transitional Housing
Solicitation # 36C24627Q0019
The Department of Veterans Affairs Network Contracting Office 6 is soliciting quotes for a firm fixed price Indefinite Delivery Indefinite Quantity contract to provide off-site Medical Respite Transitional Housing for homeless Veterans within the Salisbury VA Health Care System region. The program serves Veterans who require recuperative care and medical respite but do not need hospital-level care, providing a safe environment for those for whom typical emergency housing is unsuitable. The facility must be located within 50 miles of the Salisbury VA Medical Center or 25 miles of a Community Based Outpatient Clinic or Health Care Center. The contract includes a base period from January 1, 2027, to December 31, 2027, with four subsequent option years, with a final delivery date not exceeding December 31, 2031. The facility is expected to serve between 3 and 10 Veterans per day. Required services include 24/7 accessible accommodations meeting ADA standards, three nutritionally adequate meals daily, case management, individualized care plans, and medication monitoring. The contractor must implement strict security and privacy protocols, including HIPAA compliance and the secure storage of personal health information. Performance is monitored via a Quality Assurance Surveillance Plan, with a specific focus on critical incident reporting within 24 hours and monthly safety plan reviews for high suicide risk Veterans. This is a total small business set-aside under NAICS 623220. Award will be based on best value, evaluating technical capability, a multidisciplinary facility inspection, past performance, and price.
Residential Mental Health and Substance Abuse Facilities

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 562111
New
Federal
J045--SOLID WASTE REMOVAL
Solicitation # 36C24626Q0898
The Department of Veterans Affairs Network Contracting Office 6 is soliciting quotes for comprehensive solid waste, garbage, and recycling collection and disposal services at the Richmond Central Virginia VA Health Care System. This is a firm-fixed-price IDIQ contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The period of performance consists of a base year ending September 30, 2027, with three subsequent one-year options, potentially extending through September 30, 2030. The scope includes the scheduled removal of waste from various containers, including 42 CY and 35 CY compactors, as well as the management of universal waste such as batteries and lamps. The contract specifically excludes hazardous chemical and radioactive waste, and regulated medical waste is handled under a separate agreement. The contractor is responsible for providing clean, serviceable containers and managing the collection of mixed recyclable metals and miscellaneous yard waste. While the VA maintains ownership and responsibility for the repair of the Sani-Pak compactor and baler, the contractor is responsible for hauling and emptying the receivers. Award will be based on a best-value determination, where technical approach and past performance combined may be weighted more heavily than price. Key requirements include compliance with SDVOSB subcontracting limitations, maintaining minimum general liability insurance of 500,000 dollars, and adhering to strict packaging and labeling standards for universal waste. Total estimated tonnage for the requirement is 1,800 tons.
Solid Waste Collection

POSTED

1 day ago

DEADLINE

in 2 days
View Details
NAICS: 621511
New
Federal
Q501--STAT CLINICAL LAB TESTING AND AUTOPSIES
Solicitation # 36C24627Q0076
The Department of Veterans Affairs, Network Contracting Office 6, is conducting market research through a Sources Sought Notice to identify qualified businesses capable of providing comprehensive referral laboratory testing, specimen transportation, and autopsy services. The primary service area includes the Hunter Holmes McGuire VA Medical Center and associated Central Virginia VA Health Care System locations. The scope of work encompasses clinical and anatomic pathology requirements, including analytical testing, the processing and maintenance of specimen integrity, STAT testing, and medical autopsy services involving gross and microscopic examinations. The contractor will also be responsible for providing secure specimen transportation, consultative services for test selection and interpretation, and electronic access to patient results. This opportunity is open to various small business concerns, including SDVOSBs, VOSBs, 8(a), HUBZone, WOSB, and EDWOSB entities, under NAICS code 621511 with a size standard of 45.5 million dollars. Providers must maintain strict compliance with HIPAA regulations and hold essential certifications, such as CLIA and CMS-deemed status through organizations like the College of American Pathologists or The Joint Commission. Interested parties must submit a capability statement not exceeding five pages to Gordon Burns by October 27, 2026, at 1:00 p.m. ET. This notice is for acquisition planning purposes only and does not constitute a formal solicitation or a guarantee of a future contract award.
Medical Laboratories

POSTED

2 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS