Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on September 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--541-26-3-250-0496 - UltraSAFE Automatic Formalin Dispensing System Brand Name Only Small Business set-aside

Awarded
36C25026Q1068Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333914
New
Federal
43--ROUGHING PUMP, IN REPAIR/MODIFICATION OF
Solicitation # N0010427QYA55
This fixed-price contract, issued by NAVSUP Weapon Systems Support, is a repair purchase order for the teardown, evaluation, repair, and modification of two Roughing Pumps (NSN 7HH 4320-01-327-8122). The scope of work requires all repairs to be performed according to the contractor's standard practices and original manufacturer specifications, with a strict prohibition on the use of metallic mercury to prevent contamination of submarine and surface ship systems. The contractor is responsible for all inspection and testing at the point of origin, and must maintain inspection records for 365 days following final delivery. Packaging must adhere to MIL-STD-2073 and MIL-STD-129, with shipments delivered to DLA Distribution Norfolk, Virginia. The government intends to make a single award based on the most advantageous offer, prioritizing past performance over price. Evaluation of past performance will utilize the DoD Supplier Performance Risk System (SPRS) to assess item, price, and supplier risk. Administrative requirements include mandatory electronic submission of payment requests and receiving reports via the Wide Area Workflow (WAWF) system and reporting through the Commercial Asset Visibility Repairables Portal (CAV RP). The contract incorporates several critical regulatory clauses, including Buy American and Balance of Payments programs, cybersecurity maturity model certification requirements, and a one-year warranty for supplies of a noncomplex nature.
Navsup Weapon Systems Support Mech

POSTED

1 day ago

DEADLINE

in 30 days
NAICS: 333914
New
Federal
COMPRESSOR,ROTARY
Solicitation # SPRMM126QMK00
Solicitation SPRMM1-26-Q-MK00, issued by DLA Mechanicsburg on behalf of NAVSUP Weapon System Support, is a request for the manufacture and delivery of Rotary Compressors (NSN 4310-01-502-8208). The requirement specifies a design represented by Cage Code 62228, reference number K898155-04-1. Award will be determined based on the Lowest Price Technically Acceptable (LPTA) criteria, with evaluations considering item, price, and supplier risk via the Supplier Performance Risk System (SPRS). Offerors who are not the original equipment manufacturer must identify the OEM's CAGE code and part number and provide proof of authorized distributorship. The contract mandates strict adherence to quality and technical standards, including physical identification per MIL-STD-130 and packaging according to MIL-STD-2073. Inspection and acceptance are conducted at the origin. A critical requirement for those utilizing additive manufacturing is the maintenance and electronic submission of a Master Component Traceability Ledger via WAWF and the NAVSUP HQ AM mailbox. Administrative requirements include mandatory electronic invoicing through PIEE-WAWF and compliance with cybersecurity maturity model certification (CMMC) levels. All contractual documents are considered issued upon electronic transmission, and any changes to production facilities require written approval from the Contracting Officer.
SPRMM1 DLA Mechanicsburg

POSTED

3 days ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

The Department of Veterans Affairs, through Network Contract Office 10, is soliciting quotes for the purchase of an UltraSAFE Automatic Formalin Dispensing System for the Surgical Department at the Louis Stokes Cleveland VA Medical Center. This procurement is a Brand Name Only Small Business set-aside under NAICS code 333914. The acquisition is intended to address safety concerns regarding formalin spills and fume exposure, ensuring the facility complies with VA guidelines and protects patients and staff. The required system, manufactured exclusively by Milestone Medical, must be a proprietary, zero-exposure unit featuring a fully ventilated enclosure with charcoal and HEPA H14 filters, eliminating the need for external HVAC modifications. Key technical requirements include weight-based automated dispensing to maintain precise specimen-to-fixative ratios, patented one-way valve lids to prevent fume escape, and integrated data logging capabilities including a barcode reader and thermal printer for traceability. This is a one-time purchase, and quotes must be submitted to Kevin Peeples by September 24, 2026, at 4:00 PM EST.

General Info

VA seeks quotes for a Milestone Medical formalin dispensing system by September 24, 2026.

Contract Value

$77,000

NAICS

333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing

Place of Performance

Cleveland VA Medical Center 10701 East Blvd, Cleveland, OH, 44106, USA

Set-Aside

SBA

Award Issued Date

Documents

1
DOCX, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA

Full Description

Show more
Combined Synopsis/Solicitation Notice
*= Required Field Combined Synopsis/Solicitation Notice
DESCRIPTION This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. This solicitation is a Brand Name Only Small Business set-aside. The associated North American Industrial Classification System (NAICS) code for this procurement is 333914. The FSC/PSC is 6515. The NCO 10 for Cleveland VA Medical Center is seeking to purchase the UltraSAFE Unit: Automatic Formalin Dispensing System for the Surgical Department. This solicitation closes on September 24, 2026 @ 16:00 PM. Quotes should be submitted to Kevin Peeples Sign up to see this detail Please reference 36C25026Q1068
1. Contracting Officer s Representative (COR) NA 2. CONTRACT TITLE: UltraSAFE Unit: Automatic Formalin Dispensing System 3. BACKGROUND The VA Northeast Ohio Healthcare System (VANEOHS) is requesting the purchase of Brand Name Only, UltraSafe formalin dispensing system to include all accessories included with purchase. This system will allow Cleveland VAMC to be compliant with VA guidelines and have the equipment to keep our veterans and OR staff safe in case of a Formalin spill. There have been issues with the current hood system and PPE being used and the new system will address all issues. The Safety Department performed a walk-thru in the OR and a safety concern was raised by the safety department because of a lack of an Ultrasafe Formalin Dispenser. Not having this UltraSafe dispense could cause harm to patients/OR staff if Formalin spills and is not handled properly Cleveland VAMC is the only surgical facility in the VISN that does not have one.
4. SCOPE Government market research and justification studies consistently indicate that the UltraSAFE system occupies a unique Brand Name Only operational niche. It regularly outcompetes alternative or manual methods due to a proprietary, fully enclosed ecosystem.
Proprietary Valve Technology: It utilizes custom buckets designed with a non-return quadricuspid safety valve, allowing automatic injection of formalin without letting toxic fumes escape.
Traceability Integration: Unlike generic chemical dispensers, it features built-in scales, barcode readers, and thermal printers to automate documentation, recording the exact tissue weight, time to fixation, and formalin volume.
Independent Infrastructure: Features built-in charcoal and HEPA filters, allowing it to function as a standalone unit without requiring expensive modifications to a facility's external HVAC or exhaust lines.
The Purchase of the UltraSAFE Unit will allow Cleveland VAMC OR department to be compliant with VA guidelines also have the equipment needed to keep our veterans and OR staff safe in case of a Formalin spill there have been issues with the hood system and PPE being used and this new system would address all those concerns.
5. Specific Tasks UltraSafe is the only system that could meet all needs. It is a zero-formalin exposure it will fill .5L containers and print off labels with employee info and sample information. All the other manufacturers researched could not meet these needs. The item MUST have the following: Fully ventilated enclosure Have items automated by weight Label print & LIMS Data Zero operator Fume escape
UltraSafe is a proprietary system manufactured and exclusively supplied by Milestone Medical. UltraSafe is the only system that could meet all needs of a zero-formalin exposure system that prints off labels with employee and sample info and the entire operation is also fume-free.
Core Safety Characteristics:
Enclosed & Vented Chamber: The entire dispensing process happens inside an auto-locking, fully enclosed chamber equipped with charcoal and HEPA H14 filters. This design removes the need to hook the workstation into external building ventilation lines
Patented One-Way Valve Lids: Specimens are placed into custom buckets that seal immediately. The system uses an automatic injection nozzle that penetrates a special quadricuspid valve in the lid to inject the fluid, ensuring fumes cannot escape and preventing any backflow or spillages
Weight-Based Automated Dispensing: The unit features a built-in scale. It detects the weight of the biospecimen and automatically dispenses the perfect volume of formalin to match preset laboratory ratios (e.g., a 1:3 specimen-to-fixative ratio)
Data Logging & Traceability: A built-in barcode reader logs bucket IDs and case numbers. An integrated thermal printer automatically outputs detailed labels recording the specimen weight, exact formalin volume, and the precise time to fixation to maintain a strict chain of custody
6. Performance Monitoring Biomedical Engineering staff will work with warehouse staff to ensure delivery and incoming inspection to determine fitness for use. 7. Security Requirements The requirements do not apply; The contractor will not have access to VA sensitive information. 8. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). There will be no government-Furnished equipment of information. 9. Other Pertinent Information or Special Considerations. The requested equipment shall be interoperable/usable with current workflows and technology deployed and used within the clinical atmosphere and existing BX Microscopes and associated accessories.
a. Identification of Possible Follow-on Work.
NA
b. Identification of Potential Conflicts of Interest (COI).
NA
c. Identification of Non-Disclosure Requirements.
NA
d. Packaging, Packing and Shipping Instructions.
NA
e. Inspection and Acceptance Criteria. Biomedical Engineering staff will work with warehouse staff to ensure delivery and incoming inspection to determine fitness for use.
10. Risk Control The Surgical Service will follow any safety recommendations given by the vendor and Biomed for the equipment. 11. Place of Performance. Delivery Location: Louis Stokes Cleveland VA Medical Center 10701 East Boulevard Cleveland, OH 44106
12. Period of Performance NA 13. Delivery Schedule. One time buy
SUBMISSION Responses to this solicitation shall be submitted via email to Sign up to see this detail. Telephone responses shall not be accepted. Responses must be received no later than September 24 2026, at 16:00 pm EST, (Eastern Standard Time).
CLAUSES


FAR Number Title Date 52.209-6 PROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT JAN 2025 52.212-4 CONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS NOV 2023 52.222-90
ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS APR 2026 52.232-33
PAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT
OCT 2018 52.252-2 CLAUSES INCORPORATED BY REFERENCE FEB 1998 52.232-40 PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS MAR 2023 52.233-1 DISPUTES MAY 2014 52.233-3 PROTEST AFTER AWARD AUG 1996 852.219-76
852.203-70 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION) COMMERCIAL ADVERTISING JAN 2023
MAY 2018 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS NOV 2018 852.237-70 CONTRACTOR RESPONSIBILITIES OCT 2019

PROVISIONS



52.212-1 INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS SEP 2023 52.212-2 EVALUATION--COMMERCIAL ITEMS NOV 2021



More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 335999
New
Federal
6130--Uninterruptible Power Supply (UPS) for East Indianapolis VA Clinic
Solicitation # 36C25027Q0037
Solicitation 36C25027Q0037 is a brand-name, firm-fixed-price request for quote issued by the Department of Veterans Affairs Network Contracting Office 10 for the procurement of four Medi-Products Silent Sentry Uninterruptible Power Supply (UPS) systems for the East Indianapolis VA Clinic. The requirement consists of three SSA2080V units and one SSA30180V unit, designed to provide critical electrical backup for pharmaceutical refrigerators with a target runtime of up to 88 hours. This procurement is set aside for small businesses under NAICS code 335999, and the award will be granted to the responsible quoter offering the lowest price. The government anticipates making the purchase order award in early December 2026. Technical specifications require that equipment be unused, not refurbished, and include the latest manufacturer software and hardware updates. The product manufacture date must not exceed 24 months prior to the award date, and included batteries must be manufactured within six months of the award date. Within three days of delivery, the contractor must provide electronic service manuals and warranty information to the VA HTM Department and the IOT&A contractor. Amendment 0001 clarified that a Security Accreditation Package and Section 508 documentation are not required, and that subcontracting plans are not applicable. Additionally, the amendment extended the response time to 60 days and specified that invoices will be processed after acceptance.
All Other Miscellaneous Electrical Equipment and Component Manufacturing

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 238290
New
Federal
J059-- FY27 NRM - VISN BASE Repair B35 Elevator - 538-26-203
Solicitation # 36C25027Q0112
The Department of Veterans Affairs, Network Contracting Office 10, is conducting market research via a Sources Sought notice to determine the acquisition strategy for elevator repairs at the Chillicothe VA Medical Center in Chillicothe, Ohio. The project involves the repair of the Building 35 P-2 elevator, specifically requiring the removal of the existing hydraulic plunger and the installation of a new jack assembly and PVC casing. The contractor will be responsible for site preparation, demolition, and providing all necessary labor, materials, and equipment. Key deliverables include the provision of maintenance and operating manuals in both hard copy and electronic formats. The work must be completed within 180 calendar days from the Notice to Proceed. Due to the medical environment, the contractor must implement strict infection control, dust prevention, and noise and vibration management, and must pre-coordinate any minor utility outages with the medical center. This procurement falls under NAICS code 238290 with a small business size standard of $22,000,000.00, and the government is evaluating the appropriateness of a set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Interested sources must submit written responses to Christopher Callihan by November 20, 2026; however, the government is not seeking pricing or formal offers at this time.
Other Building Equipment Contractors

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 561621
New
Federal
H312--Fire Alarm Maintenance Service Contract FY27 - NEW Base + Four - 583
Solicitation # 36C25027Q0009
Solicitation 36C25027Q0009 is a request for proposals from the Department of Veterans Affairs Network Contracting Office 10 for a fire alarm maintenance service contract at the Richard L. Roudebush VAMC in Indianapolis, Indiana, including the main hospital, campus out-buildings, and the Cold Springs Road remote site. This contract is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The scope of work requires the contractor to provide inspection, testing, maintenance, and minor repairs for both electrical and mechanical components of fire alarm and suppression systems. The contract structure consists of a base year and four option years, with award based on price alone. Technical requirements mandate compliance with NFPA 72-2025, NFPA 25-2026, and Joint Commission standards. Key tasks include quarterly flow tests for the electric fire pump, while monthly no-flow tests are performed in-house by VA personnel. Personnel qualifications include a preference for NICET 3 certification, though NICET Level II may be accepted for certain inspections. Offerors must provide a mandatory Certificate of Compliance regarding limitations on subcontracting, ensuring no more than 50 percent of the work is performed by non-SDVOSB firms. All work must be conducted in accordance with strict VA cybersecurity and personnel vetting protocols, particularly given the critical nature of operating within an occupied healthcare facility.
Security Systems Services (except Locksmiths)

POSTED

3 days ago

DEADLINE

in 1 day
View Details
NAICS: 562211
New
Federal
F108--Radioactive Waste Removal & Disposal Services RFQ
Solicitation # 36C25027Q0108
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed-price contract to provide radioactive waste removal and disposal services for the Ann Arbor VA Medical Center in Michigan. The scope of work involves the removal, handling, packaging, and final disposition of liquid and solid low-level radioactive waste, including byproduct materials, patient treatment waste, scintillation vials, and liquid mixed waste. The contractor is responsible for providing all necessary packaging and must comply with Nuclear Regulatory Commission, Department of Transportation, and Environmental Protection Agency regulations. The anticipated period of performance begins January 11, 2027, and runs through January 10, 2032, consisting of a one-year base period and four optional one-year extensions. This procurement is a HUBZone Small Business set-aside under NAICS code 562211. To be eligible, contractors must maintain an active Radioactive Materials License granted by the NRC or an Agreement State, and all transporters must possess a commercial driver's license with a hazardous materials endorsement. Quotes must be submitted electronically to the contracting officer and include a signed SF1449 with a Unique Entity Identifier and a statement regarding the acceptance of terms and conditions. Evaluation will be based on technical capability and price, with the government evaluating the total price of the base requirement plus all option years. All offerors must be registered in the System for Award Management at the time of the offer.
Hazardous Waste Treatment and Disposal

POSTED

3 days ago

DEADLINE

in 17 days
View Details
NAICS: 561720
New
Federal
S201--VANIHCS Window Cleaning - Engineering Service Amendment to provide answers to contractor questions
Solicitation # 36C25027Q0016
Solicitation 36C25027Q0016 is a request for quotation issued by the Department of Veterans Affairs for exterior window cleaning engineering services at the Fort Wayne and Marion VA Medical Center campuses in Indiana. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and falls under NAICS code 561720. The scope of work requires the contractor to provide all labor, equipment, and materials to perform exterior washing of windows, frames, sills, sashes, and door glass twice per year. The project includes a detailed inventory of approximately 2,014 windows at the Marion inner buildings, 241 windows at the Marion outer buildings, and 1,277 windows at the Fort Wayne campus. The contract structure consists of a base year starting December 1, 2026, with four subsequent option years, not to exceed a total duration of five years. Award will be granted to the lowest-priced, technically acceptable offeror, with evaluations based on total cost, past performance, and general standards of responsibility. Key requirements include OSHA and Fall Protection certification for all personnel, background investigations per VA security standards, and a mandatory quality control program. Offerors must be registered in the System for Award Management (SAM) and the VA financial system, and must certify compliance with subcontracting limitations, ensuring no more than 50 percent of the service value is paid to non-SDVOSB or non-VOSB firms.
Janitorial Services

POSTED

5 days ago

DEADLINE

in 5 days
View Details
NAICS: 484210
New
Federal
V301--539 - Fifth Floor Pharmacy Move Service Contract
Solicitation # 36C25027Q0106
The Cincinnati Veterans Administration Medical Center requires specialized relocation services to move its inpatient pharmacy from the fifth floor to the second floor, with the eighth floor serving as a backup depending on availability. This firm-fixed-price contract, with a projected period of performance from November 2026 to May 2027, involves the disassembly, packing, transport, and reassembly of medical equipment, workstations, and furniture. A critical component of the scope is the provision of controlled environment certification services for non-hazardous pharmacy IV hoods, including laminar flow bench certification, operational particle counts, air sampling, and smoke pattern digital recording. After a temporary period of two to four weeks, the contractor will be required to move all equipment back to its original location on the fifth floor. The contractor must provide all necessary labor, vehicles, and packing materials, including RAM-board for floor protection. Key requirements include the submission of a Certificate of Public Convenience and Necessity from the Ohio PUCO and liability insurance that covers the value of the relocated equipment and facility damages. Performance will be validated through a final walkthrough and functional inspection conducted by the COR and technical personnel within 72 business hours of the move. Security protocols strictly prohibit contractor access to the VA network or any patient and employee PII/PHI. The project requires a dedicated team including a site supervisor, movers, truck drivers, and room certification testers.
Used Household and Office Goods Moving

POSTED

5 days ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS