Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on September 8, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--AUDIOLOGY EQUIPMENT " BRAND NAME OR EQUAL TO AUDIO SCAN" IAW SALIENT FEATURES MARTINSBURG VA MEDICAL CENTER MUST PROVIDE DESTINATION PRICING - F.O.B - DESTINATION

Awarded
36C24522Q1031Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
DIBBS
VENTILATOR, VOLUME, PORT
Solicitation # SPE2DS-27-Q-0026
Solicitation SPE2DS-27-Q-0026 is a fixed-price request for quotations issued by DLA Troop Support Medical Supply Chain for the procurement of two portable EMV Plus volume ventilators (NSN 6515-01-586-5898). These units must include an internal battery charger, a 3-liter oxygen reservoir kit, and a military manual. Technical specifications include a weight of approximately 9.5 lbs, an operating voltage range of 100 to 240 VAC and 11 to 33 VDC, and an operating temperature range from -13 to +167 degrees Fahrenheit. This is a Foreign Military Sales requirement for Taiwan, with delivery required within 30 days after receipt of the order and a customer required delivery date of September 29, 2026. The contract mandates strict adherence to medical packaging and marking standards, specifically Medical Marking Standard No. 1, which supersedes MIL-STD-129. Items must be provided in sealed unit containers and commercial exterior shipping containers per MIL-STD-2073-1E. Item Unique Identification (IUID) is required in accordance with MIL-STD-130 and DFARS 252.211-7003. Inspection and acceptance are set at origin, and all invoicing must be processed electronically via Wide Area Workflow as a receiving report and invoice combo, including a Certificate of Conformance. This procurement is not a small business set-aside and incorporates various FAR and DFARS clauses regarding the Buy American Program, cybersecurity reporting, and sustainable products. Quotations are due by November 6, 2026.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

about 17 hours ago

DEADLINE

in 6 days
NAICS: 334510
New
Federal
Electro-Therapeutic Modalities for Pain Management (ETMPM) - Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program
Solicitation # 36C79126R0011
The Department of Veterans Affairs is soliciting proposals under Solicitation Number 36C79126R0011 to establish multiple single-award, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity (IDIQ) base contracts for the Electro-Therapeutic Modalities for Pain Management (ETMPM) and Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program. This national program provides FDA-cleared electro-therapeutic devices and accessories to VA Medical Centers and Community-Based Outpatient Clinics to support non-opioid pain management. The scope includes portable TENS devices, Interferential Current (IFC) devices, thermal and non-thermal Short-Wave Diathermy devices, and portable Neuromodulation systems for headache disorders, along with associated accessories such as electrodes and lead wires. The procurement utilizes a VA Tiered Set-Aside Evaluation Approach, prioritizing awards sequentially from Tier 1 (SDVOSB), Tier 2 (VOSB), Tier 3 (Other Small Businesses), to Tier 4 (Other-Than-Small Businesses). Evaluation methodologies vary by item: CLINs X001 through X004 are evaluated using the Lowest Price Technically Acceptable (LPTA) method, where price is the deciding factor, while CLIN X005 is evaluated via a Best-Value Tradeoff, weighting technical factors at 60%, price at 25%, and past performance at 15%. Responsive proposals must include a signed SF 1449, a Technical Capability Statement, FDA 510(k) clearance letters, and three past performance documents. Non-manufacturers must provide OEM-issued Authorized Distributor Letters. Mandatory certifications include the Buy American Certificate for small businesses (Tiers 1-3) and the Trade Agreements Certificate for large businesses (Tier 4), as well as the Limitations on Subcontracting certification. All offerors must submit required product samples to the Denver Logistics Service facility. Following several amendments, the final deadline for all proposal documentation and product samples is November 2, 2026, at 12:00 PM CDT.
Commodities & Services Acquisition Service (36C791)

POSTED

about 22 hours ago

DEADLINE

in 2 days

General Info

Contract Value

$65,080

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Martinsburg VA Medical Center 510 Butler Avenue Martinsburg WV, 25405, MD, 25405, USA

Set-Aside

NONE

Award Issued Date

Documents

7
DOCX, High priority: read this first9 pages · rfq
High
PDF, High priority: read this firstrfq
High
PDF, High priority: read this first3 pages · specifications
High
PDF, High priority: read this firstspecifications
High
PDF, High priority: read this first21 pages · specifications
High
PDF, High priority: read this first4 pages · specifications
High
PDF, High priority: read this first2 pages · specifications
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Mohsin AbbasContract Specialist

Full Description

Show more
COMBINED SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS General Information Document Type: Combined Solicitation/Synopsis Solicitation Number: 36C24522Q1031 Posted Date: Thursday, September 8, 2022 Response Date: Tuesday, September 13, 2022 Product or Service Code: 6515 Set Aside: N/A NAICS Code: 334510, Electromedical & Electrotherapeutic Apparatus Manufacturing Contracting Office Address The Department of Veterans Affairs Network Contracting Office 5 510 Butler Avenue Martinsburg, WV 25405 Description This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation document will not be issued. The Government reserves the right to make no award from this solicitation. This solicitation is a request for quotations (RFQ). The government anticipates awarding a firm-fixed price purchase order resulting from this solicitation. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2022-07. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510, Electromedical & Electrotherapeutic Apparatus Manufacturing, with a small business size standard of 1250 employees. Set-Aside: N/A. SDVOSB s Offerors must be verified in the Vendor Information Pages (VIP), https://www.vip.vetbiz.va.gov/, at the time of receipt of quotes and at the time of award. The Department of Veterans Affairs, Network Contracting Office 5, Martinsburg VA Medical Center is soliciting quotations from all to provide Audiology Equipment Brand Name or Equal to Audio Scan at the VISN 05 facility listed below. Respondents to this solicitation must fully demonstrate their capability by supplying detailed quote information along with any other documents necessary to support the requirements below. All interested companies shall provide quotation(s) for the following: (See Attachment 1). SALIENT FEATURES SALIENT FEATURES: TWO CHANNEL CLINICAL AUDIOMETER CHANNELS: Two Independent Channels PURE TONE CHANNELS 1 AND 2 FREQUENCY RANGE Air Conduction: 125 Hz - 20,000 Hz* Bone Conduction: 250 Hz - 8,000 Hz Sound Field: 125 Hz - 8,000 Hz Paired Inserts: 125 Hz - 8,000 Hz Frequency Accuracy: ±1% Total Harmonic Distortion: < 2% (earphones and paired insert phones) < 5% (bone vibrator) HEARING LEVEL RANGE Air Conduction: -10 dB HL - 120 dB HL Bone Conduction: Mastoid: -10 dB HL - 90 dB HL Forehead: -10 dB HL - 80 dB HL Sound Field: -10 dB HL - 90 dB HL (basic speakers) -10 dB HL - 96 dB HL (high performance speakers) -10 dB HL - 102 dB HL (high performance speakers and external booster amplifier) Paired Inserts: -10 dB HL - 120 dB HL Masking Intensity Range (Calibrated in effective masking): Narrow Band Noise: Maximum dB HL is 15 dB below tone White Noise: Maximum dB HL is 30 dB below tone SIGNAL FORMAT Steady: Tone continuously present Pulsed: Tone pulsed 200 msec ON, 200 msec OFF FM: Modulation Rate: 5 Hz Modulation Depth: +/- 5% Pulsed/FM: Pulsed and modulated SPEECH CHANNELS 1 AND 2 Microphone: For live voice testing and communications INT/EXT A & INT/EXT B: Can be utilized for internal wave files or recorded speech material from an external digital device INTENSITY RANGE Air Conduction: -10 dB HL - 100 dB HL Bone Conduction: Mastoid: -10 dB HL - 60 dB HL Forehead: -10 dB HL - 50 dB HL Sound Field: -10 dB HL - 90 dB HL Paired Inserts: -10 dB HL - 95 dB HL MASKING INTENSITY RANGE Speech Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 50 dB HL (mastoid) -10 dB HL - 40 dB HL (forehead) Sound Field: -10 dB HL - 85 dB HL White Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 60 dB HL (mastoid) -10 dB HL - 50 dB HL (forehead) Sound Field: -10 dB HL - 80 dB HL SPECIAL TESTS ABLB SISI High Frequency Audiometry TEN Test QuickSIN BKB-SIN Tone Decay AMTAS Pro SPECIAL TESTS (USER DEFINED) MLB Lombard test Pure Tone Stenger Speech Stenger SAL Doerfler - Stewart Test PC ENABLED/STAND-ALONE Transfer data to connected PC with an E-Record solution software Print complete report directly to a compatible USB printer COMMUNICATIONS AND MONITORING Talk Forward: Permits the tester to speak through the examiner microphone into the selected transducer Talk Back: Allows the examiner to listen to comments from the patient in the testing booth Monitor: The monitor headset or monitor speaker built into the instrument housing may be used by the examiner to listen to Channel 1, Channel 2, Aux intercom, and/or Talk Back signals Aux Intercom: The built-in Auxiliary Intercom and assistant headset allows the examiner to speak directly to an assistant and allows the assistant to hear what is being presented to the patient On-Board VRA Control: The built-in VRA controls facilitate fast and simple activation of VRA systems STANDARD ACCESSORIES Wireless Keyboard and Mouse Gooseneck Microphone COMPLIANCE Designed, tested, and manufactured to meet the following domestic (USA), Canadian, European and International Standards: ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2, ISO 389 UL 60601-1 American Standards for Medical Electrical Equipment IEC/EN 60601-1 International Standards for Medical Electrical Equipment CSA C22.2 # 601-1-M90 Medical Device Directive (MDD) to comply with93/42/EEC 501C-61 SALIENT FEATURES SALIENT FEATURES REAL-EAR HEARING AID VERIFICATION SYSTEM REAL-EAR (REM) Per IEC 61669/ANSI S3. 46. REM Speakers dual 5 x 9 cm w/ ducted ports Probe modules dual probe and ref. microphones Probe microphone tube silicone 1 mm diameter x 75 mm Analyzer frequency range 200 16000Hz Analyzer filter parameters tones, warble 1/12 octave speech, noise 1/3 octave Analyzer display range 200 12500 Hz Probe microphone noise floor (200 12500 Hz) <45 dB SPL Frequency accuracy 1% Measurement dynamic range 30 135 dB SPL (200 2500 Hz) 30 140 dB SPL (2500 12500 Hz) Speech-like stimuli calibrated speech (level and spectrum), ISTS, band-limited and s/sh for verifying frequency lowering, live speech Broadband noise stimuli tone burst, pseudo-pink noise Narrowband stimuli warble sawtooth modulated +/- 3% over 128 ms User supplied stimuli WAV file, auto level Stimulus level range 40 85 dB SPL in 5 dB steps Measurement accuracy at 1 kHz (CAL position) +/- 1 Db Measurement accuracy re 1 kHz 200 2000 Hz +/- 1.5 dB SPL 2000 8000 Hz +/- 2.5 dB SPL 8000 12500 Hz +/- 4 dB SPL Equalization modified pressure method concurrent and stored Distance of .5m in a quasi-free sound field, where the boundaries of the room exert a negligible effect. TEST BOX (HIT) Per IEC 60118/ANSI S3.22 Test box speakers 1 front, 2 side, 30 mm independent Working space 28w x 12.7d x 3.8h cm3 Isolation @1kHz >25dB Analyzer frequency range 200 16000 Hz Analyzer filter parameters tones 1/12 octave speech, noise 1/3 octave Analyzer display range 200 12500 Hz Coupler microphone noise floor (200 12500 Hz) <40 dB SPL Frequency accuracy 1% Measurement dynamic range 30 135 dB SPL (200 2500 Hz) 30 140 dB SPL (2500 12500 Hz) Speech-like stimuli calibrated speech (level and spectrum), ISTS, band-limited and s/sh for verifying frequency lowering, live speech Broadband noise stimuli tone burst, pseudo-pink noise Narrowband stimuli pure tone User supplied stimuli WAV file, auto level Test stimulus levels 40 90 dB in 5 dB steps Test stimulus distortion (tone) <2% at 90 dB SPL <0.5% at 70 dB SPL Measurement accuracy at 1 kHz (CAL position) +/- 1 dB Measurement accuracy re 1 kHz 200 2000 Hz +/- 1.5 dB SPL 2000 8000 Hz +/- 2.5 dB SPL 8000 12500 Hz +/- 4 dB SPL Equalization modified pressure method concurrent Harmonic distortion measurement 2nd and 3rd or 2nd plus 3rd Harmonic distortion range 200 4000 Hz Harmonic distortion accuracy +/- 1% Battery drains range (+/- .01 mA) 0 20 mA Battery drain accuracy +/- 5% Telecoil loop accuracy +/- 3 dB Telecoil stimulus 31.5 mA/m per ANSI S3.22 Place of Performance: VISN 05 Medical Center. Martinsburg VA Medical Center 510 Butler Avenue Martinsburg, WV 25405 Hours of Operation: The Martinsburg VAMC requires the contractor to deliver within 60 days from the contract award to the VA medical facility warehouse above during normal business hours from 8:00AM to 3:30PM. (EST), Monday through Friday. Government Responsibilities: No Government Furnished Property (GFP) will be provided. The Government will provide access to areas and an escort when required by participating Medical Center policy. The Government will provide applicable VA Polices, Handbooks, Guides, Regulations and Medical Center Memorandums The Government will unilaterally award Task Orders to fund the required services for each facility. The Contract Specialist for this contract will be: Mohsin Abbas +1 (555) 000-0000 X54945 contact@example.gov. The Government Point of Contact for this Requirements will be: VPOC: Robert Border Phone: +1 (555) 000-0000 Ext: 6847 Email: contact@example.gov. The VAPOC for this Task Orders will be: Medical Center Name Telephone Email Martinsburg VAMC Robert Border +1 (555) 000-0000 X6847 contact@example.gov Attachment 1: Price Quote Contract Line-Item Number (CLIN) Table Attachment 2: Salient Features Attachment 3: Gray Market Prevention Language Attachment 4: Solicitation Clauses & Solicitation Provisions E. Price Schedule: The contractor must provide a price quote for each CLIN delineated in Attachment 1 to be considered for award. Must provide the authorized distributor letter if you are not the manufacturer. See Attachment 1: Price Quote Contract Line-Item Number (CLIN) Table F. Evaluation of Quotes: The Government will select the quote that represents the best benefit to the Government at a price that can be determined reasonable. The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government. IAW Salient Features and Price. When combined with technical & Salient features, Salient features are more important than Price Specific quote requirements are detailed in attached FAR 52.212-1 Instructions to Offerors Commercial Items . Following receipt of quotes, the Government will perform an evaluation using a comparative evaluation of the services quoted in accordance with FAR 13.106-2(b)(3). The Government will compare quotes to one another to select the quote that best benefits the Government by fulfilling the requirement. Contractors may submit more than one quote; however, contractors are strongly encouraged to submit their best technical solutions and prices in response to this request for quote. Once the Government determines there is/are a contractor(s) that can provide a product that meet(s) the requirements of this request for quote, the Government reserves the right to communicate with only those contractors quoting the best-suited service to address any remaining issues. G. Clauses and Provisions: The clauses and provisions for this solicitation are found in Attachment 4: Solicitation Clauses and Provisions. The Clauses and Provisions provide additional information regarding the requirements for quote submission and evaluation. See Attachment 4: Solicitation Clauses and Provisions The full text of FAR and VAAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html and http://www.va.gov/oal/library/vaar/index.asp. This is an open-market combined synopsis/solicitation for supplies as defined herein. - The government intends to award firm fixed price contract as a result of this combined synopsis/solicitation that will include the terms and conditions set forth herein. Orders will then be placed against this contract. All quotes must include a statement regarding the terms and conditions herein as follows: "The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition." OR "The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:" Offeror shall list exception(s) and rationale for the exception(s). All quotations shall be sent via email to Mohsin Abbas, Contract Specialist, Mohsin.Abbas2 @va.gov . Submission shall be received no later than 3:00PM EST on September 13, 2022. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Only e-mailed quotes will be accepted. It is the responsibility of the vendor to ensure the Government s timely receipt of their quote. Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Contract Specialist, Mohsin Abbas, contact@example.gov.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541690
New
Federal
Respirator Fit Testing
Solicitation # 36C24527Q0051
The Department of Veterans Affairs, through the Network Contract Office 5, is seeking a contractor to provide industrial hygiene support for the Louis A Johnson Medical Center in Clarksburg, West Virginia. The primary objective is the delivery of quantitative respirator fit testing for medical center employees. The contractor is required to provide all necessary equipment, including at least two TSI PortaCount machines to ensure efficient throughput, as well as all consumables. Additionally, the contractor must provide Controlled Air Purifying Respirators (CAPRs) for personnel who cannot use N95 respirators due to medical or operational reasons and may be required to train VA employees on qualitative fit testing techniques. A critical operational requirement is the ability to respond within 24 to 48 hours during outbreak conditions, such as COVID-19, Influenza, or Tuberculosis. The contract is structured with a one-year base period and four subsequent option years. All services must strictly adhere to the OSHA Act of 1970, the OSHA Respiratory Protection Standard (29 CFR 1910.134), and other relevant environmental and safety standards. Award will be based on a comparative evaluation of responsible offerors, with a focus on the total price for the basic requirement and all options. The contractor must maintain strict confidentiality of medical records under Title 38 U.S.C. and comply with VA cybersecurity and data protection directives. Invoicing is to be handled electronically per VAAR regulations, and the government retains the right to inspect and reject nonconforming services.
Other Scientific and Technical Consulting Services

POSTED

about 22 hours ago

DEADLINE

in 5 days
View Details
NAICS: 541330
New
Federal
C1DA--VISN 1 - INDEFINITE DELIVERY INDEFINITE QUANTITY ARCHITECT CONTRACT (Legacy VISN 5)
Solicitation # 36C24526R0107
The Department of Veterans Affairs, Network Contracting Office 5, is seeking an Indefinite Delivery Indefinite Quantity Architect and Engineering contract to provide ongoing engineering services for medical facilities and community based clinics within Legacy VISN 5, covering Maryland, West Virginia, and Washington D.C. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 541330, with a small business size standard of 25.5 million dollars. The overall contract value is not to exceed 450 million dollars over a ten year period. Work will be executed through firm fixed price task orders competed among awardees, with individual task order values ranging from a minimum of 2,500 dollars to a maximum of 2 million dollars. The anticipated solicitation date has been revised to late December 2026 or early January 2027, with a current response deadline listed as January 8, 2027. Prospective offerors must be registered in the System for Award Management and verified in the VetBiz Registry to be eligible for award. Interested parties are explicitly instructed not to submit SF330s during this pre-solicitation phase, as the current notices are for informational purposes only. All inquiries regarding this requirement should be directed via email to the contracting officer, Liana J Holland.
Engineering Services

POSTED

2 days ago

DEADLINE

in 2 months
View Details
NAICS: 513210
New
Federal
7A21--CVI 42 Evolve Tier 1 License Subscription
Solicitation # 36C24527Q0045
The Department of Veterans Affairs, through the VA Maryland Health Care System, is soliciting a contract for CVI Evolve Tier 1 software licenses and support for the Cardiology department at the Washington DC VA Medical Center. The contractor is responsible for providing all necessary software licenses, parts, materials, labor, and training required to implement, maintain, and upgrade the system. The scope specifically includes two seats of the CVI 42 Evolve Tier 1 Subscription, covering advanced reporting and specialized modules such as 4D Flow, Aortic Valve, Cardiac MR, Circle Plaque, Core CT, Mitral Valve, Quantitative Perfusion, and Strain. The contract is structured with a base year running from January 1, 2027, to December 31, 2027, and four subsequent one-year option periods, extending the total potential duration to five years through December 31, 2031. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and technical factors. Key requirements for offerors include providing a manufacturer's letter of authorization, detailed OEM implementation and training plans, and justification of compatibility with existing cardiovascular equipment. Administrative requirements specify that payments will be made in arrears upon receipt of a properly prepared invoice containing the contract and purchase order numbers, as well as the equipment serial numbers and model names. The contractor must comply with Buy American certifications, OSHA safety regulations, and Controlled Unclassified Information (CUI) protocols. Performance will take place at the Washington DC VA Medical Center, with the government retaining the right to inspect and test all services and supplies prior to acceptance.
Software Publishers

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

3 days ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS