70-M0087-26-CP397 - UV Preventative Maintenance Service for Santa Fe Wastewater Facility

Awarded
70-M0087-26-CP397State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The City of Santa Fe Wastewater Division has established a sole source contract with Piedmont Technical Services to provide specialized preventative maintenance for the Trojan UV3000 Disinfection system at the Paseo Real Wastewater Treatment Plant. This system is critical for disinfecting the finish water stream before it discharges into the Santa Fe River and must operate 24 hours a day year-round. A sole source award was necessary because the original manufacturer, Trojan Technologies Inc., refused to service the equipment due to the previous use of third-party replacement parts. Piedmont Technical Services was identified as the only qualified vendor capable of maintaining the system under these conditions. The contract spans a four-year term with a total budget of 350,835.60 dollars. The scope of work includes four service visits per year at three-month intervals, consisting of component verification, electrical and communication checks, cleaning UV modules, and replacing defective lamps and ballasts. Additionally, the contractor will provide refresher operation and maintenance training for staff and deliver detailed reports of findings and corrective actions after each visit. While the contractor performs the technical labor, the City of Santa Fe remains responsible for the supply and disposal of all materials, including lubricants, cleaners, lamps, and circuit boards. Invoicing occurs at the time of each service.

General Info

Piedmont Technical Services provides UV system maintenance for Santa Fe for $350,835.60 over four years.

Documents

(2)

2027-218 UV Preventative Maintenance Service - Santa Fe Wastewater Facility

PDF•justification-and-authorization

Horizons of New Mexico Services for the City of Santa Fe

PDF•specifications

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseAwarded
Posted

Solicitation

Awarded

Contract was awarded

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyNew Mexico → Wastewater Division
Contacts2 people available
OfficeSanta Fe, NM, 87501, USA
Office AddressSanta Fe, NM, 87501, USA
Contacts
Leroy AlvaradoOperations superintendent
Kristy MieraProcurement Analyst

Full Description

Show more
The Paseo Real Wastewater Treatment Plant (WWTP) owns and operates a Trojan UV3000 Disinfection system. This system is used to disinfect the finish water stream prior to it discharging into the Santa Fe River. The system requires highly specialized periodic maintenance which the current WWTP staff cannot perform. This maintenance is critical to ensure that the system continues to stay in operation 24 hours a day year-round. A request for service was requested by the manufacturer Trojan Technologies Inc., they stated because the system was repaired numerous times with third party parts, they would not be able to service our equipment. The WWTP staff located Piedmont Services and was able to use them the complete major repairs.to keep the system operational we are requesting to continue using Piedmont to complete periodic maintenance.

Similar Contracts

Same NAICS industry code

NAICS: 811310
New
SLED
Spider Motor Inspection and Repair
Solicitation # 11A4430
The California Department of Transportation (Caltrans) is soliciting bids under solicitation number 11A4430 for the inspection, maintenance, and repair of specialized spider equipment in San Diego County. The scope of work covers SC100-Re Revelation motors, SC30 Spider portable suspended scaffold motors, ST-26A Mini Spider Baskets, and ST17 Air Spider platforms. The contractor is responsible for all labor, materials, tools, and logistics, including picking up equipment from the Coronado Bay Bridge Maintenance facility and returning it upon completion. Key performance requirements include conducting inspections every 90 days, or annually if the equipment is not in use, with a strict turnaround time of four working days from the receipt of equipment. All repairs must utilize new original equipment manufacturer parts or comparable alternatives that meet current lifting and safety specifications. The contract will be awarded to the lowest responsive and responsible bidder, with preferences available for certified Small Businesses and Micro Businesses. Bids must be submitted via mail or hand-delivery by October 13, 2026, as electronic submissions are not accepted. Administrative requirements include monthly itemized invoicing in triplicate and adherence to strict data security standards, including FIPS 140-2 approved encryption for state-owned data. The agreement includes standard clauses for force majeure, equipment indemnification, and prompt payment per Government Code. Bidders must also provide certifications regarding their status as scrutinized companies and disclose any use of generative AI in their deliverables.
California Department of Transportation

POSTED

about 9 hours ago

DEADLINE

in 14 days
View Details
NAICS: 811310
New
Federal
Kolene Molten Salt Bath PM ER
Solicitation # W911KF26QA058
Solicitation W911KF26QA058 is a request for quotes for a firm-fixed-price contract to provide on-site preventive maintenance and emergency repair services for one Government-owned Kolene Molten Salt Bath Cleaning System (Unit Serial Number 1040) located at the Anniston Army Depot in Alabama. This small business set-aside under NAICS 811310 consists of a one-year base period with four one-year options, for a total potential duration of five years. The contractor is responsible for providing all labor, equipment, special tools, and materials, performing quarterly preventive maintenance and corrective repairs in accordance with original equipment manufacturer procedures. Specific requirements include completing boiler and process heater tune-up forms per 40 CFR Part 63 Subpart DDDDD to optimize emissions and equipment performance. The Government will award the contract using the Lowest Price Technically Acceptable (LPTA) process, evaluating proposals based on the lowest price and a met/not met technical factor requiring full acknowledgment of the scope of work. Awardees must comply with various federal regulations, including the Service Contract Act for wage determinations in Calhoun Counties, Alabama, and security requirements such as AT Level I awareness training for all personnel. Deliveries are FOB Destination, and invoicing must be processed through the Wide Area WorkFlow (WAWF) system. The contract also mandates adherence to MIL-STD-130 and MIL-STD-129 for item marking and shipment labeling of high-value or specified components.
W6QK Acc Anad

POSTED

about 14 hours ago

DEADLINE

in 8 days
View Details
NAICS: 811310
New
Federal
JECC/Generator Preventative Maintenance
Solicitation # FA480026S0001
Solicitation FA480026S0001 is a Sources Sought Notice issued by the Department of the Air Force, Headquarters 633D Air Base Wing, for market research purposes to formulate an acquisition strategy. The government is seeking information from small businesses under NAICS 811310 for quarterly and annual preventative maintenance and inspection services for an emergency power generation system located at Building X-132, NAVSTA Norfolk, Virginia. The equipment includes a Caterpillar Model 3412 Engine/Generator, an ASCO 7000 Series Automatic Transfer Switch, and a Caterpillar 300kVA UPS. The scope of work involves three levels of inspection and maintenance, ranging from 99-point generator inspections to comprehensive load bank testing and component replacement, all performed using original equipment manufacturer parts. The anticipated period of performance includes a base year from January 1, 2027, to December 31, 2027, with four subsequent one-year option periods extending through December 31, 2031. Key requirements for interested respondents include documented extensive experience in the Hampton Roads, VA area, certification to service Caterpillar Power Generation equipment, and the ability for personnel to obtain Defense Biometric Identification System access for the Navy base. While no security clearance is required, the services are designated as operationally critical support under DFARS 252.204-7012. Interested parties must submit a capabilities package of no more than five pages to the designated points of contact by 4:00 p.m. Eastern Time on October 13, 2026.
FA4800 633 Cons Pkp

POSTED

about 14 hours ago

DEADLINE

in 14 days
View Details

More opportunities from New Mexico → Wastewater Division

Same awarding agency

NAICS: 237990
SLED
Primary Clarifier #1 Rehabilitation Project
Solicitation # FY27-Const. ITB-009
The Primary Clarifier #1 Rehabilitation Project, solicitation FY27-Const. ITB-009, is an invitation to bid issued by the City of Santa Fe Wastewater Division to restore a primary clarifier installed in 1998. Due to extensive corrosion and mechanical failure, the project requires the removal and replacement of critical mechanical equipment, including the cage, rake arms, spiral blades, skimmers, and scum box. The scope also encompasses the replacement of the electrical control panel and necessary concrete and grout repairs. To ensure operational safety and warranty adherence, all replacement parts must be sourced directly from the original equipment manufacturer, WesTech Engineering. The contract will be awarded to the responsible bidder submitting the lowest base bid, with evaluations based on technical acceptability, quality, and workmanship. Bidders must provide a bid security of 5 percent of the total item prices, and the successful contractor must post 100 percent performance and labor and material payment bonds for contracts exceeding 25,000 dollars. Compliance with the New Mexico Public Works Minimum Wage Act and City of Santa Fe minimum wage ordinances is mandatory, requiring contractors to pay prevailing wages and submit required affidavits and subcontractor lists. Additionally, bidders must hold a valid license from the Construction Industries Division and provide a valid Resident Certificate to qualify for resident preferences.
Other Heavy and Civil Engineering Construction

POSTED

about 1 month ago

DEADLINE

in about 18 hours
View Details
NAICS: 237990
SLED
Paseo Real Wastewater Reclamation Facility Chemical Feed, and Variable Frequency Drive (VFD) Replacements
Solicitation # FY27-Const. ITB-007
The City of Santa Fe is soliciting bids for the Paseo Real Wastewater Reclamation Facility Chemical Feed and Variable Frequency Drive (VFD) Replacements project, with an estimated total cost of 3,700,000 dollars. The scope of work involves providing all materials, construction, and coordination to improve chemical feed systems, VFD electrical controls, and SCADA monitoring. Key technical requirements include replacing Modicon PLCs with A-B CompactLogix units, installing new VFDs and cables, furnishing hydrostatic level transducers, and programming touchscreen interfaces. All work must adhere to specific EMC standards and directives, with detailed construction plans and technical specifications provided to guide the demolition and installation processes. The contract will be awarded to the most responsive and responsible bidder offering the lowest base bid price. Bidders must submit their proposals electronically via the OpenGov portal, including mandatory documentation such as an Agent's Affidavit, Non-Collusion Affidavit, and proof of licensure with the New Mexico Construction Industries Division. Selected contractors are required to provide a 5 percent bid security, as well as 100 percent performance and payment bonds. Compliance with New Mexico Public Works requirements is mandatory, including the payment of prevailing wages and adherence to the City of Santa Fe Living Wage Ordinance. Performance will be managed through regular progress meetings with three-week look-ahead schedules, and final acceptance will occur at the destination following inspection.
Other Heavy and Civil Engineering Construction

POSTED

about 2 months ago

DEADLINE

in 9 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS