The 621st Contingency Response Wing requires a robust, light, and lean heating solution to operate effectively in arctic and sub-arctic environments where ambient temperatures fall below -10°F, a condition that current Environmental Control Units cannot reliably support. The UTS HH75 Heater is identified as the critical asset to close this capability gap, offering a 75,000 BTU/hr heat output with the ability to run on multiple fuels including DF1, DF2, JP5, JP8, and Kerosene—allowing operational continuity down to -50°F when Kerosene is used. Unlike the existing ECU that draws significant generator power and struggles in extreme cold, the HH75 Heater operates on minimal electrical draw of just 3 amps while relying on its 11.6-gallon fuel tank, consuming only 0.53 gallons per hour and providing up to 22 hours of continuous heating per full tank. This efficiency drastically reduces logistical burden and fuel consumption, enabling sustained field operations without overburdening power systems. The procurement of 14 UTS HH75 Heaters is intended for global deployment across training, exercises, and contingency operations, with delivery and standard manufacturer warranty coverage provided by the vendor. Maintenance, accountability, and day-to-day operations post-warranty fall under the responsibility of the CRG AGE/Electrical Power Production Work Center. The equipment must meet strict specifications including dimensions of 44.0” L x 16.4” W x 25.0” H, 120VAC power requirement, and must include essential accessories such as an exhaust stack, two heater ducts, a remote thermostat, and a full operations and maintenance manual. The solicitation, issued by the Department of the Air Force under contract number F3A1AM01, is structured as a total small business set-aside with a response deadline of June 15, 2026, and a primary point of contact at Cape May, New Jersey.
General Info
Agency
NAICS
Place of Performance
CAPE MAY CH, NJ, 08641, USASet-Aside
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Submission Closed
Organization & Contact Information
Full Description
1. General:
The CRG requires rapid deployment capabilities across the globe with equipment suitable for sustainment of operations. Current assets do not meet arctic and sub-arctic requirements for reliant heating for personnel and equipment in the field. UTS is the sole provider for a heating solution feasible for a light and lean approach. Through procurement of 14 UTS HH75 Heaters, it will satisfy the gap we face for locations reaching below -10°F and reinforce our global prowess.
2. Objectives:
The 621 CRG needs a capability that enables its force elements to operate in any AOR, including arctic and sub-arctic conditions while remaining light, lean, and agile; the UTS HH75 Heater is essential to this capability since it outperforms the current heating capability of the Environmental Control Unit (ECU). The UTS 5-ton Environmental Control Unit (ECU) meets most theater requirements for operating limitations. The main limitation is ambient operating temperatures of -25 to 125°F. To meet arctic and sub-arctic conditions the need for the UTS HH75 Heater is paramount. The Heater is multi-fueled (DF1, DF2, JP5, JP8, Kerosene). Ambient operating temperature is based off the fuel utilized. Kerosene used as fuel for the Heater opens the door to temperatures as low as -50°F. In colder environments, the ECU will push at most, 12Kw (40,000 BTU/hr) of heat. The 12Kw also translates to load on the generator which increases fuel consumption dramatically. Dependent on set-up, the generator would utilize about 4 gal an hour due to the ECUs maxing out. The UTS HH75 Heater would pull only 3Amps for the electronic controls and mainly rely on its 11.6gal fuel tank. Under continuous use, it would pull .53 gal per hour. A full tank would sustain heating needs for 22 hours.
3. Scope of Work:
This equipment will be used for the 621st Contingency Response Wing 621 CRW operations, on base and various locations for deployments, training, and exercises. The vendor will provide and deliver the equipment with standard manufacturer warranty to meet global availability for contingency forces to include arctic and sub-arctic regions. The 621 CRW will be responsible for maintaining the accountability and maintenance of the equipment past the warranty period.
4. Personnel:
The vendor will provide delivery of this item. The maintenance, accountability, and operations of this equipment will be the responsibility of the CRG AGE/Electrical Power Production Work Center.
5. Equipment Requirements and peripheral shall meet or exceed the specs of:
Heat Output: 75,000 BTU/H
Dimensions: 44.0” L x 16.4” W x 25.0” H
Tank Capacity: 11.6 Gallons
Fuel Consumption under Continuous Use: 0.53 gallons per hour
Fuel Requirements: DF1, DF2, JP5, JP8, and Kerosene
Power Requirements: 120 VAC, 60 Hz, Single Phase
Power Usage: 3 Amps @120V
Accessories Included: Exhaust Stack, Heater Ducts (2), Remote Thermostat, O&M Manual
More opportunities from Department Of Defense → Department Of The Air Force
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS