Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on August 7, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Elevator Repair and Inspection

Closed
53000-25-5104094International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → Correctional Service of CanadaView Agency

NAICS

N/A

Place of Performance

*Drumheller, CAN

Set-Aside

NONE

Documents

(1)

2025-06-25-15-23-npp-english.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Correctional Service of Canada
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Correctional Service of Canada
View Agency Profile
Office AddressN/A
Contacts
Katherine BoothPoint of Contact

Full Description

Show more
The contractor must provide maintenance to the Elevating Devices. The contractor must provide a maintenance Log for each elevating device, in a manner that will identify the Contractor's adherence to the Maintenance Services, and the applicable Codes and Standards, as described in the Safety Codes. The Project Authority will use this Log as proof of service delivery should there be a discrepancy between services the contractor has rendered, and the services invoiced. The contractor must adhere to the maintenance requirements and intervals provided within the Elevating Devices Log as a minimum. Should the contractor deem that the maintenance requirements and intervals need to be increased for the elevating devices, the contractor must advise the Project Authority who must approve the increased services. The contractor must note the increased maintenance requirements and intervals in the Maintenance Logbook. The contractor must register all work performed on the equipment under this contract in maintenance logbook must include the equipment number, date, time of arrival, contracts employees s name, nature of the work performed, any identified problem(s) and actions taken to rectify them and time of departure. The Contractor must provide the Logbook at the start of the contract, which must be kept in the elevator machine room. The Project Authority will provide any site-specific examination and test frequencies for this contract which is provided in the tasks on statement of work. The contractor must provide an equipment specific Maintenance Control Program (MCP) as per the requirements of the regulatory Authority Having Jurisdiction and ASME A17.1/CSA B 44 Safety Code for Elevators (requirement 8.6.1.2.1). The contractor must adopt and comply with any portion of the MCP that is deemed more stringent than the Particular Requirements described in this statement of work. The contractor must maintain records of all maintenance activities, adjustments, verifications, tests, repairs and modifications for the duration of the contract, and provide them to the project authority upon request. When the contractor cannot return malfunctioning elevating equipment to service within the same day, the Contractor must provide, by the end of the following working day, a written report to the project authority describing the nature of the problem and the expected date of the service resumption. When the contractor determines it is necessary to take all or part of the elevator system(s) out of service for inspections, tests maintenance services and repairs, the contractor must make arrangements with the project authority a minimum of seventy-two (72) hours in advance). The contractor must provide details of the devices to be taken out of service electronically to the Project Authority outlining the scope of the work to be performed, anticipated time frame and the equipment involved. The Contractor must use proven information collection and delivery techniques, methodologies and systems as necessary to efficiently meet CSC requirements for regulatory reporting and documentation as well as invoice verification. The contractor must ensure that computer systems and information are protected with due regard to security and ensure disaster recovery and backup plans and procedures are in place to protect that information. The contractor must provide copies of all maintenance related work, tickets and visitation records with the invoices to allow the Project Authority to verify that the contractor meets inspection and maintenance frequencies stated in the contract.

More opportunities from Government of Canada → Correctional Service of Canada

Same awarding agency

NAICS: 621111
International
Primary Care Physician Services at Nova Institution for Women
Solicitation # 21250-25-4984610B
The Correctional Service of Canada is seeking a Primary Care Physician to provide integrated, trauma-informed, and culturally appropriate medical services at the Nova Institution for Women in Truro, Nova Scotia. The successful contractor will collaborate with an interdisciplinary healthcare team to deliver patient-centered care and participate in the coordination of essential health services. This procurement is open exclusively to Canadian suppliers and is not subject to any trade agreements or Indigenous set-asides. The contract is awarded to the compliant bid with the highest technical score based on a rated criteria system totaling 90 points, with a specific tie-breaking hierarchy prioritizing criteria R3, R2, R4, and R8. The contract has a fixed duration of 36 months from the date of award, with an estimated total value ranging from 194,472 to 201,972 dollars. Payment is based on a fixed hourly rate of 438.00 dollars for both clinical work and quality improvement services. Due to the secure nature of the environment, the contractor must possess a valid Designated Organization Screening and all personnel must hold Reliability Status clearance. Bidders must certify compliance with the Ineligibility and Suspension Policy and the Federal Contractors Program. All deliverables, including health service data and reporting on public health indicators, must adhere to the Contract Security Manual and applicable federal and provincial privacy laws.
Offices of Physicians (except Mental Health Specialists)

POSTED

8 days ago

DEADLINE

in 16 days
View Details