Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on September 11, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J035--Sources Sought for Semi-Annual Elevator Inspection Services

Closed
36C25621Q0024Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541350
New
SLED
Escalator and Elevator Inspection Services for Tampa Convention Center
Solicitation # 27-P-00029
Solicitation 27-P-00029 is a Request for Quotes issued by the City of Tampa's Convention and Tourism agency for escalator and elevator inspection services at the Tampa Convention Center. The selected contractor must provide all labor, tools, and technical expertise to perform annual routine physical, mechanical, and operational safety inspections, including Category 1 no-load safety testing for elevators and mandatory operational tests for stair lifts and escalators. All work must comply with ASME A17.1, the National Electrical Code, and local building codes. Key deliverables include detailed inspection reports submitted within five business days and the filing of all necessary documentation with governing authorities to secure operational certificates by the July 31 annual expiration date. The contract is awarded to the lowest responsive and responsible bidder, with the City reserving the right to award by division, line item, or aggregate total. Qualified bidders must possess a valid Florida business license, a state or local Conveyance/Elevator Contractor License, and Certified Elevator Inspector (QEI) credentials. Additionally, contractors must demonstrate at least five years of commercial inspection experience and specific technical proficiency with KONE equipment, such as KCM831, EcoSpace, and MonoSpace systems. Submissions must be made electronically via OpenGov and include itemized flat-rate pricing, hourly rates for consulting or after-hours work, and three active commercial references. Awardees are required to provide proof of insurance and adhere to strict non-discrimination and civil rights compliance standards.
Convention & Tourism

POSTED

about 11 hours ago

DEADLINE

in 13 days
NAICS: 541350
New
Federal
H399--36C242-27-AP-0524| 528-27-1-6893-0009 Elevator Inspections, VA Medical Center (VAMC) & Bath VA Medical Center (VAMC)
Solicitation # 36C24227Q0041
The Department of Veterans Affairs is soliciting quotes for a Qualification of Elevator Inspectors (QEI)-Certified Inspector to serve as a third-party witness for annual and semi-annual safety inspections and testing at the Canandaigua and Bath VA Medical Centers in New York. This service-disabled veteran-owned small business set-aside under NAICS 541350 consists of a 12-month base period starting November 1, 2026, with four additional 12-month option years. The certified inspector is responsible for independent witnessing and reporting using VA Form 10-6167, while a separate maintenance contractor provides the labor and equipment to perform the physical tests. All work must comply with the most current ASME A17.1 and ANSI/ASME 17.2 codes. The scope of work includes semi-annual inspections, annual hydraulic pressure tests, and annual traction no-load tests during the base and final option years, with five-year traction full-load tests scheduled for Bath VAMC in option year one and Canandaigua VAMC in option year two. Services are typically performed in April and October. Award will be based on an evaluation of technical capability, past performance, and total price. Offerors must submit a technical capability statement of no more than 10 pages and adhere to New York State licensing and Service Contract Act wage determinations.
242-NETWORK Contract Office 02 (36C242)

POSTED

about 13 hours ago

DEADLINE

in 4 days
NAICS: 541350
New
Federal
NTX Elevator Inspection
Solicitation # 36C25727Q0031-0001
The Department of Veterans Affairs Network Contracting Office 17 is soliciting elevator and dumbwaiter inspection and testing services for three facilities located in Dallas, Garland, and Bonham, Texas. This requirement is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 541350. The scope of work includes annual Category 1 inspections for all conveyances and five-year Category 5 full-load testing for 23 conveyances in Garland and Sam Rayburn, and 47 conveyances in Dallas, including three dumbwaiters. All services must be performed in accordance with A17.1 and A17.2 elevator codes by TDLR-registered and QEI-certified inspectors. The contract will be awarded based on technical capabilities, past performance, and price. Deliverables include inspection reports and regulatory filings submitted to the Texas Department of Licensing and Regulation and the Contracting Officer's Representative. Invoices are to be submitted in arrears upon the completion and acceptance of services. Proposals must be submitted as a single combined PDF by November 9, 2026, at 3:00pm CST, with a 25-page limit for the technical proposal, excluding technical exhibits such as licenses and certifications. Key administrative requirements include compliance with FAR 52.222-42 and 52.222-43 regarding labor standards and the VAAR 852.219-75 certification.
257-NETWORK Contract Office 17 (36C257)

POSTED

about 13 hours ago

DEADLINE

in 11 days
NAICS: 541350
New
SLED
Campus Consulting – Inspector Of Record (IOR) Services
Solicitation # RFP2026-06AM
California State University, Chico is soliciting proposals under RFP2026-06AM for a non-exclusive Task Order Service Agreement to provide on-site Inspector of Record or Construction Inspector services for various campus projects. The selected service provider will be responsible for quality control and ensuring code compliance in accordance with the California Building Code. Qualified inspectors must hold certifications from ICBO/ICC, OSHPD, or DSA, or be a licensed architect or registered engineer in California. The contract features an initial term of two years with the option to renew for two additional two-year terms. Proposals are due by November 12, 2026, and must include a standard fee schedule, detailed experience and staffing information, project history regarding construction costs, and sample inspection documentation. Evaluation will emphasize experience with higher education institutions, specifically within the California State University system. Awarded providers must register with the Department of Industrial Relations and maintain comprehensive insurance coverage, including a 4 million dollar general aggregate and specific workers compensation limits. Payments will be processed monthly in arrears upon submission of invoices in the CSU format and written approval from the project administrator.
California State University, Chico

POSTED

about 16 hours ago

DEADLINE

in 14 days
NAICS: 541350
New
SLED
Districtwide Construction Inspection Services
Solicitation # 2027-07
The Solana Beach School District is soliciting qualifications under RFQ 2027-07 to establish a master agreement for districtwide construction inspection services. The scope of work encompasses both general construction-related consultant services and specialized inspection and materials testing. The District intends to create pools of prequalified firms, short-listing up to five of the most qualified firms per specialty to be assigned work on an as-needed basis via written task orders. The initial term of the agreement is one year, with the possibility of four one-year extensions for a total maximum duration of five years. Selection is based on qualifications rather than the lowest price, utilizing a 100-point scoring scale that emphasizes the depth of the firm's experience and the qualifications of proposed professionals. Minimum requirements include at least ten years of experience with California public K-12 projects, current DIR registration, and specific DSA certifications for project inspectors or laboratory of record status for materials testing. Awarded firms must comply with California prevailing wage laws, non-discrimination policies, and the Drug-Free Workplace Act. Invoicing occurs monthly and requires detailed documentation of time spent and work accomplished. Responses are due by November 10, 2026, and must include four hard copies and one electronic PDF copy on a USB drive for each specialty applied for.
Solana Beach School District

POSTED

about 17 hours ago

DEADLINE

in 12 days
NAICS: 541350
New
SLED
Residential Energy Audit
Solicitation # NSD-RFQu-26-006
The City of Phoenix Neighborhood Services Department is soliciting offers for residential energy audit consulting services under solicitation NSD-RFQu-26-006. The resulting agreement will have a five-year term beginning December 1, 2026, or upon final recording by the City Clerk. The selected contractor will perform various technical assessments, including Manual J, Manual D, Manual S, Appliance, and CO2 audits. Deliverables include detailed electronic audit reports submitted via a secure portal, featuring property photographs and documentation of pre-existing and post-construction conditions. Performance timelines are strict, with standard audits required within two weeks of request and emergency audits scheduled within 24 hours and performed within three business days. Award decisions will be based on the most advantageous offer, with a heavy emphasis on the Statement of Qualification, which requires at least one year of relevant experience and detailed staffing and quality assurance narratives. Contractors must maintain valid professional licenses, adhere to City of Phoenix confidentiality and data protection standards, and ensure all personnel pass Police Department background checks. Compliance requirements include adhering to the Clean Air Act, Federal Water Pollution Control Act, and various nondiscrimination mandates such as Title VI of the Civil Rights Act. Additionally, contractors working outdoors must maintain a written heat safety plan in both English and Spanish. Invoicing is handled electronically in PDF format, with payments issued upon receipt of signed delivery or service tickets.
Neighborhood Services

POSTED

1 day ago

DEADLINE

in 8 days
NAICS: 541350
New
Federal
H259-- ELECTRICAL 5-YEAR ARC FLASH STUDY (VA-27-00002938)
Solicitation # 36C25227Q0050
The Department of Veterans Affairs is seeking a firm fixed price contract modification for a comprehensive Arc Flash Hazard Analysis at the Iron Mountain VAMC. The project requires a Registered Professional Electrical Engineer with at least five years of experience to oversee the study, which must comply with NFPA 70E, NFPA 70, and IEEE 1584 standards. The scope encompasses all significant electrical distribution locations from the utility supply down to 208V systems, including switchgear, motor control centers, and panelboards. The contractor will perform data gathering and field verification, a three-phase bolted fault short-circuit study, a protective device coordination study, and the calculation of incident energy and flash protection boundaries. Key deliverables include the installation of machine-printed arc flash warning labels, the adjustment of protective devices, and a final comprehensive report featuring time-current curves, fault current calculations, and updated electrical one-line diagrams in AutoCAD and PDF formats. The contractor must also conduct an exit briefing for facility staff to discuss hazard areas and NEC violations. All work must be completed within 180 days of the notice to proceed, with onsite activities performed during normal business hours. This procurement is intended as a sole source award to SDV Services Inc. under 41 U.S.C. 1901 simplified acquisition procedures to ensure consistency with ongoing electrical testing at the facility.
252-NETWORK Contract Office 12 (36C252)

POSTED

1 day ago

DEADLINE

in 4 days
NAICS: 541350
New
Federal
Aviation Operations Center (AOC)- Building Engineer Report (BER)
Solicitation # 15DDHQ27R00000001
Solicitation 15DDHQ27R00000001 is a request for proposals from the Department of Justice, Drug Enforcement Administration, to obtain a Building Engineer Report (BER) for the Aviation Operations Center (AOC) located at Alliance Airport in Fort Worth, Texas. This is a 100% small business set-aside procurement conducted under FAR Part 12 for commercial services, with the government intending to issue a single firm fixed price purchase order. The scope of work requires a comprehensive inspection of the building's interior, exterior, and grounds, covering structural elements, HVAC, plumbing, electrical, life safety, and force protection. Key deliverables include a summarized BER based on a Building Condition Assessment with cost estimates and photographs, a detailed scheduled operations and maintenance plan, and a list of potential energy conservation improvements. Proposals must be submitted electronically to Jose Marin by November 30, 2026, and must be divided into a technical volume and a business volume. The technical volume is limited to 20 pages and will be evaluated based on technical capability, key personnel qualifications, and past performance. These non-price factors are significantly more important than price, although price will be evaluated for reasonableness. Award will be based on the best value to the government. Contractors must comply with strict security requirements, including the submission of Facility Access Request forms, execution of non-disclosure agreements, and completion of mandatory cybersecurity and privacy training. Performance is structured across several tasks, with the final BER due two weeks after the review meeting.
Office Acquisition Management

POSTED

1 day ago

DEADLINE

in about 1 month

General Info

NAICS

541350 - Building Inspection Services

Place of Performance

Veterans Health Care System of the Ozarks (VHSO) 1100 North College Avenue, Fayetteville, MS, 72703

Set-Aside

NONE

Documents

1

36C25621Q0024.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
Contacts1 person available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA

Full Description

Show more
The purpose for this source sought notice is to locate interested companies that can furnish the REQUIREMENTS listed in the SOW that is attached. Offeror's capability to meet this requirement including any current contracts with more than 2 years of Period of Performance (Civilian or Government) to include meeting the below listed accreditations or similar standards, facility description, capabilities, and certifications. Responses must show clear and convincing evidence that your company and its employees have the capabilities, training, and qualifications to provide this service to be considered as a source. The following information is requested in a response to this RFI: 1. General Company information- Offeror's company name, DUNS, full address, point of contact, title, phone number, and email address. Name: Address: Contact Person: Phone number: Email address: DUNS number: Cage Code Number: Company website if available: 2. Business Type Please put a check mark or circle around the type of business you are below: a) Large b) 8(a) c) HubZone d) Small Business e) Small Disadvantaged Business f) Woman Owned Small Business g) Service-Disabled Veteran Owned Small Business h) Veteran Owned Small Business ***Note - All Veteran Owned Businesses must be registered in VetBiz at http://www.vip.vetbiz.gov/general_user/register/default.asp to be considered a Veteran Owned Business. Socioeconomic status (whether Service Disable Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, 8(a), Woman Owned, Small Disadvantaged, etc.). If stating SDVOSB or VOSB status, your company must be verified with the seal/icon or show pending verification in VetBiz Registry (https://www.vip.vetbiz.gov//) to be considered as a SDVOSB or VOSB source. 3. How long has your company provided these services? See attached Past Performance. 4. Provide information for any current or past VA contracts for these products and services. 5. Is your company registered in the System for Award Management at WWW.SAM.GOV? The NAICS code for the procurement is 541350 and the small business size standard is $8 Million dollars. Any future RFP will be conducted in accordance with FAR Parts 12 and 15. The Government may elect to award a Firm Fixed Price contract resulting from the solicitation. Responses to this market survey should be e mailed to contact@example.gov. No telephone responses will be accepted. Please provide a detailed response to the below Performance Work Statement stating how you can meet all aspects stated. It is requested that responses be received no later than 2:00 pm Central, September 25th, 2020. *NOTE* SDVOSB Contractors to provide documentation to fulfill capabilities of the following clause: FAR 52.219-27. No solicitation document is available currently; this notice is to acquire information only. Vendors interested in providing an offer will have to respond to a separate solicitation announcement. Statement of Work (SOW) Elevator Semi Annual Inspection Veterans Health Care System of the Ozarks (VHSO) Fayetteville, Arkansas The Contractor must furnish all Labor, Supervision and management in accordance with the SOW and drawing(s) required for the Semi-Annual inspection of nineteen (19) elevators. General Any provision or partial provision of the Contract drawing(s), documents or requirements that is not consistent with this SOW and Drawing(s), is null and void only to the extent of the inconsistency. All other provisions or partial provisions of the Contract drawing(s), documents, or requirements must remain in full force and effect. Information Technology (IT) security requirements Certification and Accreditation (authorization) (C&A) of the Contractor system: The C & A requirements do not apply, and a Security Accreditation Package is not required. Safety must be the Contractor s highest priority. Contractor s work must be conducted in a manner and at times which would present the least amount of disruption to the VHSO facility. Scope of Work: The Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies and related services in accordance with (IAW) the Contract including, but not limited to, the SOW, drawing(s), and applicable Federal, State, and Local laws, codes, regulations, and ordinances as follows: A minor and a major inspection will be completed by a qualified licensed elevator inspector of sixteen (16) Hydraulic Elevators, two (2) Traction Elevators, and one (1) Cart Lift. Minor Inspection: must include all phases of elevator operation, functioning of all safeties, operation controls, lighting, exhaust systems, oil levels (as applicable), cables, stops, hoist ways, shafts and elevator pits and mechanical rooms. Major Inspection: must consist of all above items plus act as a witness for the annual safety testing of all units. Qualified service technician(s) must be trained and certified on the systems and equipment and furnish documentation to the COR no later than ten (10) calendar days after date of award of contract. Note: The contractor will provide inspection services only and will not perform any maintenance Minimize Elevator systems and equipment downtime. Regulations: The contractor must maintain elevators in accordance with all requirements of the American Standard Safety Code ANSI A17.1 latest edition or revisions and all existing Federal, State, and local laws, codes, rules and regulations set forth by all applicable authorities having jurisdiction where the work is being performed. Five-Year Load Test Must be on-site and overview outside contractor. Test to be performed by an outside contractor IAW another VA contract. Test to be conducted on two (2) Traction elevators and one (1) cart lift. VHSO must approve dates test will be conducted. Test is to be done in base period of contract. Scheduled Equipment: Location/Description Load Test Cart Model/Serial Capacity (Ibs.) Control Bldg. 1 Main Passenger 2 Yes Dover FT1-AOC078366020- 000022 3500 Cetek Flex-H Bldg. 1 Main Passenger 1 Yes Dover/Kone 3500CAP 3500 Cetek Flex-H Bldg. 1 Cart Lift Yes D A Matot Miprone-SL 500 Bldg. 1 & 2 Elev #1 No Thyssen Krupp Type 32 3500 TAC 22 Bldg. 1 & 2 Elev #2 No Thyssen Krupp Type 32 3500 TAC 22 Bldg. 2 Service Elev. 1 No Montgomery/ Kone FH1-00234324812- 000146 3500 Cetek Flex-H Bldg. 2 Service Elev. 2 No Montgomery/ Kone FH1-00234324812- 000147 3500 Cetek Flex-H Bldg. 2 Freight/Kitchen No Montgomery/ Kone FH1-00234324812 2500 Cetek Flex-H Bldg. 3 Passenger No Dover AP12040 3500 Cetek Flex-H Bldg. 4 Passenger No Thyssen Krupp FH1-00234324812- 000133 3500 Cetek Flex-H Bldg. 5 Wheel Chair Lift No Thyssen Krupp PCDE60 750 Unknown Primary Care Staff No Thyssen Krupp Tac 20 3000 TAC 20 Building 18 elev. 1 No Thyssen Krupp Tac 20 4000 TAC 22 Building 18 elev. 2 No Thyssen Krupp Tac 20 4000 TAC 22 Primary Care Passenger No Dover Kone MIPROM HS 4500 Cetek Flex-H Bldg. 21 Elev. 1 No Thyssen Krupp Type 32 3500 TAC 22 Bldg. 21 Elev. 2 No Thyssen Krupp Type 32 3500 TAC 22 Bldg. 21 Elev. 3 No Thyssen Krupp Type 32 3500 TAC 22 Bldg. 44 No Thyssen Krupp TAC 22 4500 TAC 22 Drawings: Contractor must verify dimensions, locations, measurements, and quantities. Contractor to notify Contracting Officer Representative (COR) of verification and differing site conditions. Drawing List: Drawing Number Drawing Name Date Revision Number AA001 Title Sheet & Table of Contents 07/10/19 - MS100 Site Plan 07/10/19 - MS101 Bldg 1&2 Elev & Primary Care Patient Elev Maint Pt 07/10/19 - MS102 Bldg 1 Maint Cart Lift Maint Pt 07/10/19 - MS103 Bldg 2 SVC Elev Maint Pt 07/10/19 - MS104 Bldg 2 Freight/Kitchen Lift Maint Pt 07/10/19 - MS105 Bldg 18 Elev Maint Pt 07/10/19 - MS106 Bldg 3 Elev Maint Pt 07/10/19 - MS107 Bldg 4 Elev Maint Pt 07/10/19 - MS108 Bldg 5 Elev Maint Pt 07/10/19 - MS109 Bldg 21 Elev Maint Pt 07/10/19 - MS110 Bldg 44 Elev Maint Pt 07/10/19 - MS111 Primary Care Staff Elev Maint Pt 07/10/19 - MS112 Bldg 1 Main Passenger Elev Maint Pt 07/10/19 - Contractor Access and Activities Contractor must comply with the VHSO security management program. Contractor must not enter the work site without VHSO issued identity Badge. Contractor can be subject to inspection of personal effects when entering or leaving the project site and VHSO property. Contractor superintendent must escort Contractor employees to Engineering (Building 7-A) to obtain badge(s). The Contractor must maintain a log of Employee Names, Badge ID Numbers, Start Date(s), Departure Date(s), ID Lost Date(s), and ID Return Date(s). Updated Badge log must be given to the COR weekly or as directed by COR. Contractor s superintendent must return all badges on day of departure of employee from contract to COR. Contractor s superintendent must return all remaining badges at contract closeout to COR. Lost Badges must be reported immediately to the COR and documented on badge log. Contractor is responsible for a $100.00 fee for each lost or unreturned badge to VHSO. Property Access Regular Business Hours: PM must be scheduled during normal business hours, 0730 to 1600 hours, Monday through Friday (excluding the following Federal holidays New Year s Day, Martin Luther King Day, Presidents Day, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day). COR must be informed in the following situations: To schedule any work. After arriving on site but before any work is started. To provide an approximate timeframe for the work. As soon as it is known that the work will take longer than expected. At completion of work prior to leaving the facility. To report any incomplete aspects of the work or issues that could not be corrected during the visit. To furnish a written plan for corrective action for any work that cannot be completely within 24 hours. Plan must be furnished to and approved by the COR. Safety: Safety must be the Contractor s highest priority. The Contractor must be in accordance with Federal, State, Local OSHA regulations, latest edition of NEC, latest edition of NFPA 70E, and 01 35 26 Safety Requirements specification. The Contractor must furnish and have in place Personal Protective Equipment (PPE) including, but not limited to, safety signage, cones, and barricades, to protect the safety of VHSO patients, employees, visitors, volunteers, tenants and others. Contractor must not be permitted to work without proper PPE and can be directed to leave job site. Contractor must furnish required safety items and wear required PPE. Work must be conducted in a manner and at times which would present the least amount of disruption to the VA healthcare facility. Contractor must not leave or unattended out-of-service any utility, fire protection, or security system without written permission of the COR. If a utility, fire protection, or security system is not functioning at the end of a work period without written permission of the COR, then the Contractor must restore the system(s) to working order prior to leaving the jobsite or must furnish an around-the-clock watch until the system is functioning properly. If the Contractor fails to do so, the Contractor must reimburse the Government for any costs incurred by the VHSO to furnish around-the-clock watch and/or repair the system(s). Vehicles and Construction equipment: Contractors keys to unattended vehicles and equipment must be removed and vehicles locked. Unloading and Parking: No materials or equipment are permitted through the front entry. Use loading dock entrance only for loading and unloading, do not leave vehicle(s) unattended. Contractor parking on VHSO property is limited to availability of designated Contractor parking. Contractor must have prior written approval of on-site Contractor parking from COR. Elevators: Contractor must use COR designated elevators and must protect elevator cabs and controls during periods of use. Contractor must not exceed elevator weight limits. Designated elevator(s) and usage times are not to interfere with VHSO activities. Radios and Mobile Devices: Contractor must use mobile devices at low volume or outside. Contractor must not carry on conversations in hallways or near any patient areas. AM/FM radios and other media producing devices must not be used in the VHSO Buildings. Noise: Contractor must coordinate and schedule noise making activities with the COR. For any noise making work activities, the Contractor must furnish a written request to the COR for COR approval a minimum of seven (7) business days prior to noise making activities. The COR will schedule and provide written authorization to proceed three (3) business days in advance of the proposed activity. Disposal: The Contractor must submit a written request(s) for disposal of any government owned materials, equipment, or property in advance to the COR for COR written approval. Contractor must remove and properly dispose construction debris, materials, equipment, and substances from VHSO property daily into the Contractor supplied containers. Construction debris created from the contract must not be disposed of at the job site, in VHSO dumpsters, or on VHSO property. Disposal of construction debris, materials, equipment, and substances from the contract must be in accordance with applicable Federal, State, Local and environmental laws, rules or regulations. The Contractor must ensure and furnish appropriate documentation to the CO that all hazardous waste handlers, haulers, and disposal facilities are properly licensed. The Contractor must furnish shipping manifest and documentation of proper disposal of any construction debris, materials, equipment, and substances from the contract work prior to final payment. Contractor must return the work site to the condition in which it was found at the Contractor s expense. Warranty: Contractor must guarantee workmanship for a period of one (1) year after COR written acceptance of work. Contractor must furnish a minimum 1-year parts and labor warranty on materials, equipment, parts and components, furnished and any manufacturer s warranty greater than one (1) year. Photography: Contractor must not photograph any patients, personnel, visitors, and others on VHSO property. Contractor must be escorted by VHSO personnel to take jobsite related photos and be coordinated by COR. Other requirements: Anything remaining in place that is damaged or defaced by the Contractor must be restored by the Contractor to the existing condition, at no additional expense to the Government. The Contractor must furnish adequate protection to VHSO property and personnel prior to work activities. Contractor moved items must be put back by the Contractor to original locations and conditions as work is completed, at no additional expense to the Government. No unauthorized work to be initiated without the prior written approval of the CO. Work required for the project must be in accordance with the best practices and in accordance with the intent of the SOW, drawings, and specifications. VHSO utilities and work areas may not be immediately available and the Contractor must be flexible in the inspections schedule at no additional cost to VHSO. All OEM recommended safety aspects of the equipment being serviced must be adhered to.

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 238290
New
Federal
N099--JLM Roll Up Door Replacement
Solicitation # 36C25627Q0092
Solicitation 36C25627Q0092 is a combined synopsis and request for quote issued by the Department of Veterans Affairs for the replacement of a motorized roll-up door at the John L. McClellan Veterans Hospital. This is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238290. The project requires the contractor to provide all labor, tools, and equipment, including a scissor lift and forklift, to remove and dispose of the existing door and install one grey 7 by 9 foot motorized rolling steel rapid slat door with insulated slats and an obstruction safety device. The award will be a firm-fixed-price contract with a performance period of 30 days from the Notice to Proceed and includes a one-year warranty. The government will utilize the Lowest Price Technically Acceptable (LPTA) evaluation process, focusing on technical capability, price reasonableness, and the completion of the VA Notice of Limitations on Subcontracting. Interested offerors must submit a three-volume quote package consisting of technical capabilities, a completed price schedule, and the required VAAR certification. Quotes must be emailed to Joseph Warren by 3:00 PM CST on November 18, 2026. A site visit is scheduled for November 6, 2026, at 10:00 AM, and all inquiries must be submitted by November 10, 2026. Performance will take place at the Central Arkansas Veterans Healthcare System in North Little Rock, Arkansas, and contractors must comply with all OSHA, ANSI, CAN, and UL standards.
Other Building Equipment Contractors

POSTED

about 13 hours ago

DEADLINE

in 20 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS