Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on July 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J043--Kaeser Compressor PM and Repairs

Closed
36C24126Q0689Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
SLED
ICE 8A - Ft Benning Improvements
Solicitation # 70CMSW25R00000011
This firm-fixed-price task order, issued under a MACC multiple-award IDIQ contract by the Department of Homeland Security Immigration and Customs Enforcement, provides design-build services for life, safety, and operational improvements at Fort Benning, Georgia. The project has an estimated magnitude between 4.0 million and 4.5 million dollars and a period of performance not to exceed 365 days from the date of award. The scope of work includes the installation of aluminum awnings at the shipping and receiving dock and Fiske Range, turf replacement at Fiske Range, the demolition and site restoration of Building 2294, gutter and drainage improvements at Building 234, and the replacement and maintenance of commercial HVAC systems across Buildings 2949, 234, 1836, and 19. Additionally, the contractor will perform general facility improvements for Building 301 and the DAGr Team facility. Award will be based solely on the lowest total evaluated price, though the government will also evaluate the offeror's technical approach, design resources, and the validity of their methodology. Proposals must be submitted in two volumes: a technical and safety volume and a pricing volume using the provided CSI division template. The contract is subject to the Davis-Bacon Act, requiring prevailing wage rates and specific paid sick leave provisions. Key administrative requirements include the submission of payment requests via the Invoice Processing Platform accompanied by certified payroll, and the provision of performance and payment bonds. Final inspection and technical assistance will be managed by the Contracting Officer's Representative.
Bristol Alliance of Companies

POSTED

about 10 hours ago

DEADLINE

in 6 days
NAICS: 238220
New
SLED
PIDC Project 3 - Dorm RTU Replacement and SCADA
Solicitation # 872287
This firm-fixed-price task order, issued under an 8(a) MACC IDIQ, involves the replacement and upgrade of Rooftop HVAC Units (RTUs) for the Alpha, Bravo, Charlie, and Delta dorms, as well as a SCADA system upgrade at the Port Isabel Detention Center in Los Fresnos, Texas. The project objective is to replace corroded and obsolete equipment with high-quality, coastal weather-resistant, and durable systems that exceed commercial standards. The scope includes removing existing RTUs, replacing necessary piping, electrical, and ducting, and installing new SCADA software and two chemical feed pumps in compliance with Texas Commission of Environmental Quality standards. The estimated magnitude of the project is between 1.2 million and 1.5 million dollars, with a period of performance of 365 days from the date of award. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates a sound technical approach, appropriate design resources, and a comprehensive quality control and safety program. Key requirements include the submission of a Quality Control Plan, a safety plan, and the designation of a Project Manager with at least five years of relevant federal contracting experience. The contractor must also provide a one-year warranty for installation and craftsmanship and ensure all personnel pass required background checks for site access. Compliance with the Davis-Bacon Act and associated executive orders regarding wages and sick leave is mandatory. All payment requests must be submitted electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 10 hours ago

DEADLINE

in 13 days
NAICS: 238220
New
RFQ7593 Smoke Detector Installation
Solicitation # RFQ7593
Management & Training Corporation (MTC) is soliciting bids for a fee-for-service subcontracting opportunity to provide smoke detector installation and fire system services at the Sierra Nevada Job Corps Center in Reno, Nevada. The scope of work requires the replacement of 43 smoke detectors across specific dormitory rooms, including 12 detectors in rooms 11, 15, and 18, 12 detectors in room 19, and 19 detectors in rooms 20 and 21. The contractor must ensure all installed detectors communicate with the fire panel and that all work adheres to NFPA standards and local Authority Having Jurisdiction requirements. Bids must be submitted via email to Tom Williams by 3:00 PM PST on September 18, 2026. To be considered, applicants must provide a completed bid sheet, proof of insurance, and a supplier packet containing a W-9, self-certification form, and acceptance of terms and conditions. This opportunity is open to various small business set-asides, including SDB, WOSB, HUBZone, and Veteran-Owned businesses, under NAICS code 238220. Award decisions will be based on the best value as determined by MTC. The contract mandates compliance with Service Contract Labor Standards and Wage Determination No. 2015-5595 Revision 28 for labor rates in Washoe and Storey counties. Additionally, subcontractors must provide a 12-digit Unique Entity ID and certify their debarment status under FAR 52.209-6 if the subcontract exceeds 30,000 dollars. Strict adherence to government and Department of Labor guidance regarding the protection of sensitive and proprietary information is required.
Sierra Nevada Job Corps Center

POSTED

about 10 hours ago

DEADLINE

in 7 days
NAICS: 238220
New
2026-Clearfield-Bldg E8 Welding HVAC
Solicitation # 2026- Clearfield- Welding Bldg. E8 HVAC Replacement
Management & Training Corporation (MTC) is seeking fixed-price lump sum bids for a subcontracting opportunity to replace the 20hp motor connected to the rooftop HVAC system at the Clearfield Job Corps Center in Clearfield, Utah. The scope of work includes the complete removal and replacement of the existing motor, electrical hookup, system testing, commissioning, and the provision of onsite training and maintenance manuals for facility personnel. Bidders must conduct a physical site visit and sign the attendance roster to be eligible for award. The project requires the contractor to handle all permits, fees, and the removal of all construction debris and packaging from the site. Bids are due by September 19, 2026, at 3:00 PM MST and must be submitted via email to the designated points of contact. Submissions must include a signed MTC Bid for Lump Sum Contract form, a detailed cost breakout on company letterhead, and a bid bond guarantee from a surety company with at least an A- rating. This opportunity is set aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB. Award decisions will be based on overall best value. The contract is subject to federal regulations, including the Davis-Bacon Act for prevailing wages in Davis County, Utah, and the Contract Work Hours and Safety Standards Act. Compliance with OSHA requirements and federal, state, and local codes is mandatory. Selected contractors must provide a 12-digit Unique Entity ID (UEI) and a 9-digit Tax ID via the MTC Supplier Self-Certification form. Payment will be processed through pay applications using AIA G702 and G703 forms based on a submitted Schedule of Values. Performance and payment bonds must be submitted within five business days of receiving an Intent to Award letter.
Management & Training Corporation

POSTED

about 10 hours ago

DEADLINE

in 8 days
NAICS: 238220
New
CBP7664 Wellness HVAC Compressor Replacement
Solicitation # CBP7664
Management & Training Corporation is seeking bids for a subcontracting opportunity to replace a failed HVAC/refrigeration compressor at the Wellness facility of the Sierra Nevada Job Corps Center in Reno, Nevada. The project is structured in five phases: preparation and environmental safety, demolition and removal, installation of an OEM-specified compressor and related components, system testing and commissioning, and final closeout. The contractor must ensure full restoration of cooling capacity and operational efficiency while adhering to EPA Section 608 regulations for refrigerant recovery. The work must be completed within 30 consecutive business days following a written Notice to Proceed. Bids will be evaluated based on overall best value, considering price, quality, and delivery schedules. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent of the base bid is required, along with performance and payment bonds from an A-rated surety company. Submission requirements include a signed bid sheet, a detailed bid breakout, and verification of a physical site visit. Contractors must comply with Davis-Bacon Act wage determinations for Washoe County and provide self-certification of their business size and socioeconomic category per FAR 52.219-8. Final payment is contingent upon the submission of a Notice of Final Completion, certified payroll reports, and two sets of operation and maintenance manuals.
Sierra Nevada Job Corps Center

POSTED

about 10 hours ago

DEADLINE

in 12 days
NAICS: 238220
New
This is a subcontracting opportunity to replace a chiller in McKinney, TX.
Solicitation # subcontracting-opportunity-replace-chiller-mckinney-tx
Serrato Corporation is seeking bids for a subcontracting opportunity to replace a failing 246-ton air-cooled chiller at the North Texas Job Corps Center, specifically in Building 214/215 located in McKinney, Texas. The scope of work includes the demolition and disposal of the existing unit and the installation and startup of a like-kind, similar model replacement. Additionally, the project requires the installation of a JACE 9000 central integration point for building automation controls to manage the chiller, pumps, boiler, and four multi-zone air handling units. The contractor must also perform cleaning and inspection of the air handling units, replace belts, install four 3-way control valves, and replace three of the four air handler VFDs. Bids must be submitted by September 18, 2026, and quotes must remain valid for 90 days. Required submission documentation includes manufacturer equipment specifications, Form 1413 for Davis-Bacon Act certified payroll compliance for work exceeding 2,000 dollars, and a Certificate of Liability Insurance naming Serrato Corporation as the holder. Insurance minimums include 1 million dollars for Commercial General Liability and Comprehensive Automobile Liability, and 500,000 dollars for Employers Liability. This opportunity is set aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB. Primary points of contact for the project are Stacy Smith and Roy Henderson.
Serrato Corporation DBA North Texas Job Corps

POSTED

about 10 hours ago

DEADLINE

in 7 days
NAICS: 238220
New
Main Building 1 Wing 5 – Six Rooftop HVAC Unit Replacement – Glenmont Job Corps Center
Solicitation # S26-010
The Glenmont Job Corps Center is soliciting proposals from qualified, New York State licensed contractors for the replacement and installation of HVAC equipment within Main Building No. 1, Wing 5 (Education Building) in Glenmont, New York. The project involves replacing two 7.5-ton split-system units for the auditorium, one 6-ton rooftop unit for the library and computer lab, and one 12.5-ton rooftop unit for the north and east wing classrooms. Additionally, the scope includes installing four 2-ton ductless mini-split heat pump systems, removing a window air-conditioning unit, and abandoning two 5-ton rooftop units in place. Comprehensive associated work encompasses demolition, roof curbs and penetrations, ductwork, refrigerant and condensate piping, electrical work, controls, structural roof evaluations, and fire alarm and duct smoke detector installations, concluding with testing, balancing, and commissioning. This solicitation is set aside for various small business categories, including SDB, WOSB, HUBZone, and Veteran-Owned Small Businesses. The project must be completed within 210 calendar days following the written Notice to Proceed, and the facility will remain operational throughout the construction period. Key deadlines include a pre-proposal site walkthrough on September 10, 2026, with vendor questions due by September 14, 2026. Final proposals must be submitted by September 21, 2026, at 4:00 PM ET. All work must comply with applicable New York State codes, safety regulations, and environmental requirements.
Adams and Associates, Inc.

POSTED

about 10 hours ago

DEADLINE

in 10 days
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) ABL Dormitory
Solicitation # 26-141
Adams & Associates, Inc., operating for the U.S. Department of Labor, is soliciting a single lump sum contract to replace HVAC systems at the ABL Dormitory within the Atterbury Job Corps Center in Indiana. The project involves replacing existing R-22 Bryant gas-fired furnaces and condensing units with new 12.5 SEER packaged units utilizing non-R22 refrigerants such as R-410A or R-454B. The scope includes the installation of compatible coils and the reuse of existing electrical disconnects, ductwork, and thermostat wiring. All recovered refrigerant must be labeled and left on-site. Eligible bidders must be registered in SAM.gov with a valid Unique Entity ID and hold a valid Indiana Contractor's License. A mandatory site visit is scheduled for September 23, 2026, with final proposals due by October 5, 2026. Award decisions will be based on best value, evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). The contractor must provide a sequenced construction schedule within 10 days of the Notice to Proceed and guarantee all workmanship for one year. Payment terms are Net 30, contingent upon the submission of certified payroll records, a completed SF 1413, and the release of liens. Compliance with EPA, OSHA, and Davis-Bacon Act wage determinations is required.
Adams & Associates, Inc.

POSTED

about 10 hours ago

DEADLINE

in 23 days

AI Contract Overview

Show more

The Department of Veterans Affairs, through its Networking Contracting Office 01, is pursuing a sole source procurement under FAR 6.302-1 to award a service contract to Kaeser Compressors, Inc. for preventative maintenance and emergency repairs on a dedicated inventory of Kaeser rotary screw air compressors and condensate treatment systems located in Building 1 at the West Haven VA Medical Center in Connecticut. The contract has a one-year base period with four one-year option periods, potentially extending performance to five years, and requires all work to be performed on-site during regular business hours with emergency responses available 24/7. Only factory-certified technicians from Kaeser Compressors, Inc. who are located within 200 miles of the site are eligible, due to the proprietary nature of the equipment’s onboard diagnostics, control software, and system-specific components, which can only be properly serviced using OEM tools, training, and parts. Use of reverse-engineered or refurbished parts is strictly prohibited unless explicitly authorized in writing by the Contracting Officer, and all maintenance must comply with manufacturer guidelines and VA directives including VHA HEFP HVAC Manual, ANSI/ASHRAE/ASHE standards, and VA Policy 138-075 for Lock Out Tag Out procedures. Contractors must maintain adequate stock of OEM parts or secure replacements within 24 hours, adhere to strict VA security protocols including site sign-in, badge usage, and restricted movement, and comply with prohibitions on tobacco use and photography on campus. All service activities must be coordinated with the Contracting Officer’s Representative and documented with detailed written reports submitted within five business days of each visit, including equipment identifiers, services rendered, parts used, and labor hours. Maintenance and repair reports, along with waste manifests where applicable, must be delivered in both hard copy and electronic format within three business days. Billing is based on actual labor hours performed with a minimum charge of six hours and $500 in parts for unscheduled repairs; unused labor is credited back. The U.S. Government retains unlimited rights to all data, reports, and electronic records generated under the contract, which must be preserved according to NARA and Privacy Act standards, with no unauthorized retention or dissemination allowed. Subcontracting is forbidden without prior written approval, and the Government reserves the right to suspend operations or remove personnel during national emergencies or security incidents. The contract does not require a Security Accreditation Package as the systems are not networked, and the NAICS code

General Info

Sole source contract to Kaeser Compressors for on-site OEM maintenance of air compressors at West Haven VA Medical Center with 24/7 emergency support.

Agency

Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)View Agency

NAICS

238220 - Plumbing, Heating, and Air-Conditioning ContractorsView NAICS

Place of Performance

ME

Set-Aside

NONE

Documents

(1)

Solicitation 36C24126Q0689 - Kaeser Compressor PM and Repairs

DOCXrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

special-notice

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Organization / Agency
Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
View Agency Profile
Office AddressTOGUS, ME, 04330, USA
Contacts
Rosangela PereiraContract Specialist

Full Description

Show more
The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in West Haven, CT intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Kaeser Compressors, Inc. for the following requirement:
Kaeser Compressor Preventative Maintenance and Repairs
Statement of Work
BACKGROUND VA Connecticut Healthcare System requires Preventative Maintenance, Scheduled, and Unscheduled Repair Services for an inventory of Kaeser air compressor equipment serving inpatient care areas located in Building 1 at the West Haven VA Medical Center.
JUSTIFICATION Veterans Health Administration (VHA) seeks to continue to improve the operational capabilities of campus chillers by establishing services that result in fewer operational problems, improved communications, increased efficiency within the facility and to improve the quality of services to veterans.
LOCATION OF SERVICES VA Medical Center West Haven 950 Campbell Avenue West Haven, CT 06516
PERIOD OF PERFORMANCE One (1) base year with four (4) one-year option periods
QUALIFICATIONS To be considered eligible for consideration, potential bidders shall have a field service representative located within 200 miles of the West Haven Campuses of the VA Connecticut Healthcare System and have been trained by the Original Equipment Manufacturer (OEM) on the specific model of equipment that he/she is being asked to provide services for.
Bidders must provide upon request, documentation of factory certified service/maintenance training on the specific equipment under the terms of this contract. The Contracting Officer and/or Contracting Officer s Representative (COR) specifically reserve the right to reject any of the Contractor s personnel and refuse them permission to work on the equipment outlined herein, based upon credentials provided.
The contractor shall maintain sufficient stock of parts needed for repair and maintenance of the equipment or be able to secure parts within twenty-four (24) hours. All parts used shall be new OEM parts only. Reverse engineered and/or refurbished parts shall not be utilized under the terms of this contract without explicit permission, in writing, from the Contracting Officer.
Subcontracting of any ensuing award of this solicitation shall not be allowed without written permission of the Contracting Officer. Service response on calls from unauthorized personnel could result in non-payment.
Bidders shall perform a pre-bid walkthrough at 8:30 a.m. on May 14, 2026 at VA Medical Center West Haven located at 950 Campbell Avenue, West Haven, CT 06516. Meet at Building 15 and obtain a temporary day badge and complete a sign-in sheet.
SCOPE OF WORK The contractor shall furnish all labor, materials, equipment, tools, supervision, and all incidentals to complete the work for the services described in this document including preventative maintenance, inspection, calibration, and unscheduled repairs.
Scheduled maintenance shall be completed Monday Friday and during regular business hours of 8:00 a.m. and 4:30 p.m. Acknowledgement and response of an Emergency service call shall be within 2 hours.
No work shall be performed on Government Holidays unless an emergency status has been indicated by the VA Contracting Officer.
A&A requirements do not apply, and a Security Accreditation Package is not required; the controller is not installed on the VA Network. Inventory Manufacturer/ Equipment Model Year Material Number Serial Number Building/ Room Kaeser Rotary Screw Oil-Lubricated Air Compressor with Integrated Dryer SK 15 T 125 psi SC2 TriVolt US 2024 101981.01 1753 Building 1, 10th Floor North Kaeser Rotary Screw Oil-Lubricated Air Compressor with Integrated Dryer SK 15 T 125 psi SC2 TriVolt US 2024 101981.01 1754 Building 1, 10th Floor North Filter with Float Drain Filter F22KE 2025 102115.11411 1843 Building 1, 10th Floor North Filter with Float Drain Filter F22KE 2025 102115.11411 1837 Building 1, 10th Floor North Kaeser Condensate Treatment System KCF 25 Condensate Treatment System 2025 ANKCF25 18460 Building 1, 10th Floor North Kaeser Condensate Treatment System KCF 25 Condensate Treatment System 2025 ANKCF25 18461 Building 1, 10th Floor North Drain Trap AMD 6550


Description of Services: Maintenance, Inspections, and Testing to maintain compliance with: VHA Directives ANSI/ASHRAE/ASHE Standard VHA HEFP HVAC Design Manual Revised November 01, 2022. Scheduled Maintenance Requirements: The manufacturer maintenance procedures take precedence over other recommended maintenance procedures. Service provider shall schedule and coordinate all work with the VA COR, Utilities Supervisor, and Chief, Maintenance & Operations. All LOTO request and procedures shall be in compliance with the VA Connecticut Healthcare System Medical Center Policy 138-075. Coordinate all placement and removal of Lock Out Tag Out devices for any energy source with the VA COR/ Maintenance & Operations. Rotary Screw Compressors: Frequency: (Quarterly) Check unit for proper operation excessive noise or vibration. Check and resolve warning/alarm messages. Check shutdown and safety functions. Check monitoring, switching, and control components. Update controller software. Re-grease drive and fan motor bearings. Replace bearings per manufacturer guidelines. Replace air filters and inlet filter mats. Replace oil, oil filter, oil separator cartridge, and scavenger line. Inspect electrical components, indicators, and displays. Maintain compressor drive components. Clean and test cooler. Check and maintain control valves. Inspect mechanical components. Check and resolve network communication errors. Maintain air treatment components. Replace air treatment filter elements. Clean and maintain condensate drain and dirt trap. Replace condensate treatment components. Perform any additional maintenance tasks as recommended in the manufacturer s operation and maintenance manuals. Perform operational test and return to service. Remove debris from worksite. Complete maintenance checklist and report deficiencies to VA Contracting Officer, COR, and Chief Engineer.
Spare Parts and Expendables Inventory Refrigerant Compressor Oil Hoses of different sizes Filters Sealant
Unscheduled/Emergency Repairs & Service Calls Requirements: Unscheduled Repairs shall be performed at the direction of the VA Contracting Officer. The vendor and the VA Contracting Officer will agree on the Scope of Work, labor hours, and parts cost prior to the commencement of work. Emergency service and repairs are available on a 24 hour per day basis and will be invoiced at the prevailing straight time or overtime contract customer rate. Vendor shall submit the following associated with unscheduled repairs. Labor Hours: Minimum 6 Hours Parts Cost: Minimum Total $500.00
SUBMITTALS/DELIVERABLES The contractor shall submit two (2) hard copies and electronic copy of all maintenance, test, inspection, repair and installation data/reports to the COR within three (3) business days. The contractor shall submit any waste manifest documents as applicable.
SPECIAL INSTRUCTIONS Service Provider Check-in: All employees of the service provider shall comply with VA Security Management Program and obtain permission of the VA Police and restricted from unauthorized access. Upon arrival, the Service Provider shall sign-in at Building 15 and receive a temporary identification badge prior to performing services at VA Connecticut Healthcare System. The Service Provider shall wear visible identification always displaying the name and company ID while on site. All site visits shall be coordinated with the VA COR.
Documentation: At the conclusion of each repair and scheduled maintenance visit, the Service Provider shall provide a written service report indicating the date of service, the model, serial number, and location of equipment serviced, the name of the representative, and the services performed, and parts replaced and labor hours. The reports shall be delivered within five business days.
Per VA Directive 1805, smoking vaping, and smokeless tobacco are prohibited on the grounds of VA facilities, including in vehicles. This Directive applies to all Service providers and their employees.
No photography of VA premises is allowed without written permission of the contracting officer. Patients and staff are not to be photographed at any time.
VA reserves the right to close down or shut down the facilities and order Service provider employees off the premises in the event of a national emergency. The Service provider may return to the site only with the written approval of the VA Contracting Officer.
Parking for Service provider and its employees shall be in designated areas only. Service provider to coordinate with COR.
The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall hold and save the government, its officers, and agents, free and harmless from liability of any nature occasioned by the Service provider s performance. Working space and space available for storing materials shall be as determined by the COR. Workers are subject to the rules of the Medical Center applicable to their conduct. Execute work in such a manner as to reduce impacts with work being done by others.
Billing: Billing: Provide COR with a report or statement of work completed and include statements with request for payment. Statement should include service completed and the date each service item was completed. Labor charges shall be billed hourly, and any unused labor totals will be credited back to the VA Medical Center on the next billing cycle, upon receipt of the service report.
TERMS AND CONDITIONS User Responsibility: The Service Provider shall not be held responsible under the terms of this contract for repairs to equipment necessitated by user abuse and/or misuse of equipment. NARA Records Management Requirements
The following standard items relate to records generated in executing this contract:
Citations to pertinent laws, codes and regulations such as 44 U.S.C. Chapter 21, 29, 31, and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228.
Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest.
Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records.
Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act.
The Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract.
The Government Agency owns the rights to all data/records produced as part of this contract.
The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. The Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data.
The Contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.].
No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage, or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules.
The Contractor is required to obtain the Contracting Officer s approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material and/or records generated under or relating to this contract. The Contractor (and any sub-contractor) is required to abide by Government and Agency guidance for protecting sensitive and proprietary information.
The NAICS code for this requirement is 238220.
Kaeser Compressors, Inc. holds sole claim on their proprietary Kaeser compressor system. The installed equipment incorporates proprietary on-board computer controls, diagnostic software, and control logic that is unique to Kaiser compressors. These proprietary systems are essential for proper operation, troubleshooting, software updates, calibration, and repair.
Only technicians with access to Kaeser proprietary diagnostic software programming tools, technical documentation, and original equipment manufacturer (OEM) supported replacement components can ensure equipment is serviced in accordance with the manufacturer specifications.
This notice of intent is not a solicitation nor is it a request for proposal. However, all responsible sources may submit a capability statement demonstrating the ability to provide the requested services, in writing by Wednesday, July 29, 2026 at 12PM EST. Responses should be sent to Rosangela Pereira at Rosangela.Pereira@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS