Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 20, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J044--Minneapolis VAMC Boiler, Deaerator and Condensate Tank Inspections Sources Sought

Closed
36C26325Q0485Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541350
New
SLED
Escalator and Elevator Inspection Services for Tampa Convention Center
Solicitation # 27-P-00029
Solicitation 27-P-00029 is a Request for Quotes issued by the City of Tampa's Convention and Tourism agency for escalator and elevator inspection services at the Tampa Convention Center. The selected contractor must provide all labor, tools, and technical expertise to perform annual routine physical, mechanical, and operational safety inspections, including Category 1 no-load safety testing for elevators and mandatory operational tests for stair lifts and escalators. All work must comply with ASME A17.1, the National Electrical Code, and local building codes. Key deliverables include detailed inspection reports submitted within five business days and the filing of all necessary documentation with governing authorities to secure operational certificates by the July 31 annual expiration date. The contract is awarded to the lowest responsive and responsible bidder, with the City reserving the right to award by division, line item, or aggregate total. Qualified bidders must possess a valid Florida business license, a state or local Conveyance/Elevator Contractor License, and Certified Elevator Inspector (QEI) credentials. Additionally, contractors must demonstrate at least five years of commercial inspection experience and specific technical proficiency with KONE equipment, such as KCM831, EcoSpace, and MonoSpace systems. Submissions must be made electronically via OpenGov and include itemized flat-rate pricing, hourly rates for consulting or after-hours work, and three active commercial references. Awardees are required to provide proof of insurance and adhere to strict non-discrimination and civil rights compliance standards.
Convention & Tourism

POSTED

about 9 hours ago

DEADLINE

in 13 days
NAICS: 541350
New
Federal
H399--36C242-27-AP-0524| 528-27-1-6893-0009 Elevator Inspections, VA Medical Center (VAMC) & Bath VA Medical Center (VAMC)
Solicitation # 36C24227Q0041
The Department of Veterans Affairs is soliciting quotes for a Qualification of Elevator Inspectors (QEI)-Certified Inspector to serve as a third-party witness for annual and semi-annual safety inspections and testing at the Canandaigua and Bath VA Medical Centers in New York. This service-disabled veteran-owned small business set-aside under NAICS 541350 consists of a 12-month base period starting November 1, 2026, with four additional 12-month option years. The certified inspector is responsible for independent witnessing and reporting using VA Form 10-6167, while a separate maintenance contractor provides the labor and equipment to perform the physical tests. All work must comply with the most current ASME A17.1 and ANSI/ASME 17.2 codes. The scope of work includes semi-annual inspections, annual hydraulic pressure tests, and annual traction no-load tests during the base and final option years, with five-year traction full-load tests scheduled for Bath VAMC in option year one and Canandaigua VAMC in option year two. Services are typically performed in April and October. Award will be based on an evaluation of technical capability, past performance, and total price. Offerors must submit a technical capability statement of no more than 10 pages and adhere to New York State licensing and Service Contract Act wage determinations.
242-NETWORK Contract Office 02 (36C242)

POSTED

about 11 hours ago

DEADLINE

in 4 days
NAICS: 541350
New
Federal
NTX Elevator Inspection
Solicitation # 36C25727Q0031-0001
The Department of Veterans Affairs Network Contracting Office 17 is soliciting elevator and dumbwaiter inspection and testing services for three facilities located in Dallas, Garland, and Bonham, Texas. This requirement is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 541350. The scope of work includes annual Category 1 inspections for all conveyances and five-year Category 5 full-load testing for 23 conveyances in Garland and Sam Rayburn, and 47 conveyances in Dallas, including three dumbwaiters. All services must be performed in accordance with A17.1 and A17.2 elevator codes by TDLR-registered and QEI-certified inspectors. The contract will be awarded based on technical capabilities, past performance, and price. Deliverables include inspection reports and regulatory filings submitted to the Texas Department of Licensing and Regulation and the Contracting Officer's Representative. Invoices are to be submitted in arrears upon the completion and acceptance of services. Proposals must be submitted as a single combined PDF by November 9, 2026, at 3:00pm CST, with a 25-page limit for the technical proposal, excluding technical exhibits such as licenses and certifications. Key administrative requirements include compliance with FAR 52.222-42 and 52.222-43 regarding labor standards and the VAAR 852.219-75 certification.
257-NETWORK Contract Office 17 (36C257)

POSTED

about 11 hours ago

DEADLINE

in 11 days
NAICS: 541350
New
SLED
Campus Consulting – Inspector Of Record (IOR) Services
Solicitation # RFP2026-06AM
California State University, Chico is soliciting proposals under RFP2026-06AM for a non-exclusive Task Order Service Agreement to provide on-site Inspector of Record or Construction Inspector services for various campus projects. The selected service provider will be responsible for quality control and ensuring code compliance in accordance with the California Building Code. Qualified inspectors must hold certifications from ICBO/ICC, OSHPD, or DSA, or be a licensed architect or registered engineer in California. The contract features an initial term of two years with the option to renew for two additional two-year terms. Proposals are due by November 12, 2026, and must include a standard fee schedule, detailed experience and staffing information, project history regarding construction costs, and sample inspection documentation. Evaluation will emphasize experience with higher education institutions, specifically within the California State University system. Awarded providers must register with the Department of Industrial Relations and maintain comprehensive insurance coverage, including a 4 million dollar general aggregate and specific workers compensation limits. Payments will be processed monthly in arrears upon submission of invoices in the CSU format and written approval from the project administrator.
California State University, Chico

POSTED

about 14 hours ago

DEADLINE

in 14 days
NAICS: 541350
New
SLED
Districtwide Construction Inspection Services
Solicitation # 2027-07
The Solana Beach School District is soliciting qualifications under RFQ 2027-07 to establish a master agreement for districtwide construction inspection services. The scope of work encompasses both general construction-related consultant services and specialized inspection and materials testing. The District intends to create pools of prequalified firms, short-listing up to five of the most qualified firms per specialty to be assigned work on an as-needed basis via written task orders. The initial term of the agreement is one year, with the possibility of four one-year extensions for a total maximum duration of five years. Selection is based on qualifications rather than the lowest price, utilizing a 100-point scoring scale that emphasizes the depth of the firm's experience and the qualifications of proposed professionals. Minimum requirements include at least ten years of experience with California public K-12 projects, current DIR registration, and specific DSA certifications for project inspectors or laboratory of record status for materials testing. Awarded firms must comply with California prevailing wage laws, non-discrimination policies, and the Drug-Free Workplace Act. Invoicing occurs monthly and requires detailed documentation of time spent and work accomplished. Responses are due by November 10, 2026, and must include four hard copies and one electronic PDF copy on a USB drive for each specialty applied for.
Solana Beach School District

POSTED

about 15 hours ago

DEADLINE

in 12 days
NAICS: 541350
New
SLED
Residential Energy Audit
Solicitation # NSD-RFQu-26-006
The City of Phoenix Neighborhood Services Department is soliciting offers for residential energy audit consulting services under solicitation NSD-RFQu-26-006. The resulting agreement will have a five-year term beginning December 1, 2026, or upon final recording by the City Clerk. The selected contractor will perform various technical assessments, including Manual J, Manual D, Manual S, Appliance, and CO2 audits. Deliverables include detailed electronic audit reports submitted via a secure portal, featuring property photographs and documentation of pre-existing and post-construction conditions. Performance timelines are strict, with standard audits required within two weeks of request and emergency audits scheduled within 24 hours and performed within three business days. Award decisions will be based on the most advantageous offer, with a heavy emphasis on the Statement of Qualification, which requires at least one year of relevant experience and detailed staffing and quality assurance narratives. Contractors must maintain valid professional licenses, adhere to City of Phoenix confidentiality and data protection standards, and ensure all personnel pass Police Department background checks. Compliance requirements include adhering to the Clean Air Act, Federal Water Pollution Control Act, and various nondiscrimination mandates such as Title VI of the Civil Rights Act. Additionally, contractors working outdoors must maintain a written heat safety plan in both English and Spanish. Invoicing is handled electronically in PDF format, with payments issued upon receipt of signed delivery or service tickets.
Neighborhood Services

POSTED

1 day ago

DEADLINE

in 8 days
NAICS: 541350
New
Federal
H259-- ELECTRICAL 5-YEAR ARC FLASH STUDY (VA-27-00002938)
Solicitation # 36C25227Q0050
The Department of Veterans Affairs is seeking a firm fixed price contract modification for a comprehensive Arc Flash Hazard Analysis at the Iron Mountain VAMC. The project requires a Registered Professional Electrical Engineer with at least five years of experience to oversee the study, which must comply with NFPA 70E, NFPA 70, and IEEE 1584 standards. The scope encompasses all significant electrical distribution locations from the utility supply down to 208V systems, including switchgear, motor control centers, and panelboards. The contractor will perform data gathering and field verification, a three-phase bolted fault short-circuit study, a protective device coordination study, and the calculation of incident energy and flash protection boundaries. Key deliverables include the installation of machine-printed arc flash warning labels, the adjustment of protective devices, and a final comprehensive report featuring time-current curves, fault current calculations, and updated electrical one-line diagrams in AutoCAD and PDF formats. The contractor must also conduct an exit briefing for facility staff to discuss hazard areas and NEC violations. All work must be completed within 180 days of the notice to proceed, with onsite activities performed during normal business hours. This procurement is intended as a sole source award to SDV Services Inc. under 41 U.S.C. 1901 simplified acquisition procedures to ensure consistency with ongoing electrical testing at the facility.
252-NETWORK Contract Office 12 (36C252)

POSTED

1 day ago

DEADLINE

in 4 days
NAICS: 541350
New
Federal
Aviation Operations Center (AOC)- Building Engineer Report (BER)
Solicitation # 15DDHQ27R00000001
Solicitation 15DDHQ27R00000001 is a request for proposals from the Department of Justice, Drug Enforcement Administration, to obtain a Building Engineer Report (BER) for the Aviation Operations Center (AOC) located at Alliance Airport in Fort Worth, Texas. This is a 100% small business set-aside procurement conducted under FAR Part 12 for commercial services, with the government intending to issue a single firm fixed price purchase order. The scope of work requires a comprehensive inspection of the building's interior, exterior, and grounds, covering structural elements, HVAC, plumbing, electrical, life safety, and force protection. Key deliverables include a summarized BER based on a Building Condition Assessment with cost estimates and photographs, a detailed scheduled operations and maintenance plan, and a list of potential energy conservation improvements. Proposals must be submitted electronically to Jose Marin by November 30, 2026, and must be divided into a technical volume and a business volume. The technical volume is limited to 20 pages and will be evaluated based on technical capability, key personnel qualifications, and past performance. These non-price factors are significantly more important than price, although price will be evaluated for reasonableness. Award will be based on the best value to the government. Contractors must comply with strict security requirements, including the submission of Facility Access Request forms, execution of non-disclosure agreements, and completion of mandatory cybersecurity and privacy training. Performance is structured across several tasks, with the final BER due two weeks after the review meeting.
Office Acquisition Management

POSTED

1 day ago

DEADLINE

in about 1 month

General Info

NAICS

541350 - Building Inspection Services

Place of Performance

Minneapolis VAMC 1 Veterans Drive, Minneapolis, MN, 55417, USA

Set-Aside

NONE

Documents

1

Minneapolis VAMC Boiler, Deaerator and Condensate Tank Inspections Sources Sought

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts1 person available
OfficeSaint Paul, MN, 55101, USA
Office AddressSaint Paul, MN, 55101, USA
Contacts
Jeffrey BrownContracting Officer

Full Description

Show more
The Minneapolis VAMC requires engineering evaluation of boiler, deaerator and condensate tank reliability/life expectancy inspection services in accordance with the draft Statement of Work (SOW) below. This is a sources sought/proof of capability solicitation looking for vendors to perform the services per the SOW for market research purposes. No awards of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your contact and organization information with a description of proof of capability to: contact@example.gov on or before February 28th, 2025. Only emailed responses will be considered. Additionally, please provide answers as appropriate to the following questions in the table below with your response to this sources sought. Failure to respond to the following questions may affect the acquisition strategy. 1. Identify your organization's socio-economic category. 2. State whether any of the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.). 3. State if subcontracting is contemplated for this requirement and what percentage of the work will be subcontracted and for what tasks. - *If applicable, VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses or Service Disabled Veteran Owned Small-Businesses.* *If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses.* STATEMENT OF WORK Minneapolis Veteran Affairs Health Care System Engineering Evaluation of Boiler, Deaerator and Condensate Tank Reliability/Life Expectancy Inspection 1. Introduction: The Minneapolis Veteran Affairs Health Care System (MVAHCS) centers provides critical health care which requires reliable steam supply for sterilization, domestic hot water, kitchens, and building heating/air conditioning. Boilers and associated equipment serving VA medical centers must be reliable, safe and efficient. The age of boilers and associated equipment is often a major indicator of reliability. The VHA Directive 1810 (1), BOILER AND BOILER PLANT OPERATIONS, assigns useful life expectancy , in years, to the boilers and plant equipment. The Directive requires that retention of certain equipment beyond the useful life expectancy must be based on an engineering evaluation of the reliability, efficiency and cost effectiveness of continued operation. 2. Summary of Requirements: The consultant shall supply all labor, material, and equipment to inspect and test the boilers and ancillary equipment at the MVAHCS. The work shall be documented in a full report of findings and recommendations. This report shall include, but not be limited to, an itemized list of parts and equipment that need to be repaired or replaced and services that are required along with estimated costs for these supplies and services. The report must be stamped by a licensed professional engineer. The following is a general list of equipment that must be addressed. Item Manufacturer Model # Serial # Location Boiler #1 Cleaver Brooks DL-68-RH WG3285 Building 69 Boiler #2 Cleaver Brooks DL-68-RH WG3286 Building 69 Boiler #3 Cleaver Brooks DL-68-RH WG3284 Building 69 Boiler #4 Cleaver Brooks DL-52-RH WG3287 Building 69 Condensate Tank Midwest Tank Co. Unknown 16261 Building 69 Deaerator tank Chicago Heater Co. Unknown 5754 Building 69 3. Qualification Requirements for Consultant and Inspection Personnel: A professional engineering firm (Professional License (PE)) that specializes in life expectancy evaluations must be part of the team and provide an analysis and recommendations under their seal based on the evaluation of the boiler and associated equipment by means of visual inspection and non-destructive testing conducted by experienced boiler inspectors and non-destructive testing experts on the team. The inspections shall be supervised on-site by a Qualified Professional Inspector , defined as anyone or combination of the following. Proof of qualifications shall be provided with the bid and as part of the final report. A boiler inspector who has a valid commission from the National Board of Boiler and Pressure Vessel Inspectors. A boiler inspector who has qualified by passing a written examination under the laws, rules and regulations of a jurisdiction of a state. A boiler inspector who is regularly employed as a boiler inspector by a jurisdiction that has adopted and administers one or more sections of the ASME Boiler and Pressure Vessel Code as a legal requirement, and has a representative serving as a member of the ASME (American Society of Mechanical Engineers) Conference Committee. A boiler inspector who is regularly employed by an insurance company that has been licensed or registered by the appropriate authority of a state of the United States to write boiler and pressure vessel insurance. C. Non-destructive testing personnel shall be certified to American Society for Non-destructive Testing (ASNT) Level II, who are experienced in evaluating boilers and associated equipment. Inspector: The Qualified Professional Inspector shall demonstrate familiarity with and ready access to the current versions of the following codes and manuals: ASME Boiler and Pressure Vessel Code ASME B31.1, Power Piping Code ANSI/NB-23, National Board Inspection Code NACE International Standard RP0590, Recommended Practice for Prevention, Detection and Correction of Deaerator Cracking VHA Boiler Plant Safety Device Testing Manual, current edition. The NDT technicians shall demonstrate familiarity with and ready access to the current version of NACE International Standard RP0590, Recommended Practice for Prevention, Detection and Correction of Deaerator Cracking MVAHCS Responsibilities for Preparation of Boiler Inspection Since steam production cannot cease, the consultant and the VA COR will have to work closely to develop an inspection schedule that will ensure the facility can always meet steam demand with sufficient backup. The boiler will be prepared by MVAHCS for the inspection prior to the scheduled arrival of the inspector. This includes cooling the unit to near ambient temperature and having all manways and access doors open, the unit cleaned of loose materials, lock-out, tag-out in place, connecting piping isolated, proper illumination provided, compliance with confined space access requirements including having safety personnel present in the boiler plant. MVAHCS will comply with any other requirements of the inspector that are considered reasonable by MVAHCS and have been presented in writing at least two weeks prior to the scheduled inspection. Remove all manway and handhole covers, access panels. Remove all drum internals. Clean all fireside and waterside surfaces. Remove insulation from water tube boilers steam and mud drum ends and from locations where pipes are connected to the boiler. Arrange for ladders, lifts and other devices necessary to allow access to the boiler. Furnish copies of the original National Board (NB) Manufacturer s Data Report inspection form that was prepared for the boiler when it was new and NB Report of Repair forms if boiler pressure vessel repairs have been performed. 6. Inspection Requirements for Boilers Consultant shall develop a detailed list of information required at least two weeks prior to the inspection to allow the VA to compile the information. Consultant shall develop a detailed schedule of the inspection in consultation with the VA COR to ensure availability of equipment as needed during the execution of the project. Visually inspect the following items and document the locations with a sketch or pictures. Any adverse findings must be documented with pictures and notes in detail. All data shall be included in the final report as supporting documentation. Review the boiler/s history including operating conditions, date of last inspection, current inspection certificate, ASME stamping, National Board registration number, materials of construction, extent of post weld heat treatment, history of repairs and modifications. All welded and threaded pipe connections to the boiler shell or drum for signs of leakage or defects in the welded areas. Defects must be documented as to location with a sketch or picture and be non-destructively tested. Boiler support structure for proper alignment, evidence of sagging, shifting or misalignment. Boiler casings for signs of warping, misalignment and overheating. All furnace tubes and all accessible convection tubes for alignment, evidence of corrosion, erosion, bulges, sagging, defective or deteriorated welds. Exposed surfaces of steam and mud drum in furnace, particularly ligament areas between tubes, for evidence of corrosion, cracking, scale buildup, other defects. Refractory for cracking, shifting, sagging, bulging or general deterioration. Internal areas of steam drum and mud drum (inside boiler shell in fire tube boilers). Welded outlet connections. Surface of drums for pitting or surface discontinuities. Ligament areas between tube holes for cracking. Each tube end and internal surface of representative number of tubes for pitting, erosion, corrosion and excessive scale buildup. Utilize fiber optic inspection equipment to inspect interior of tubes. Clean and inspect shell or tube sheet between tube holes for cracking. 7. MVAHCS Responsibilities for Preparation of Condensate Tanks Inspection Since steam production cannot cease, the consultant and the Energy Center Supervisor will have to work closely to develop an inspection schedule that will ensure the facility can always meet feed water demand with sufficient backup. 8. Inspection Requirements for Condensate Tanks NATIONAL BOARD INSPECTION CODE, Part RB, Inservice Inspection of Pressure-Retaining Items. Review the condensate history including operating conditions, date of last inspection, current inspection certificate, ASME stamping, National Board registration number, materials of construction, extent of post weld heat treatment, history of repairs and modifications. Assess the external parts of the condensate and accessories and piping for safety, accessibility, cleanliness. proper operation, and compliance with codes. Inspect for evidence of leakage. Inspect condensate tank safety valve installation and verify that the valves have proper set pressure and capacity and are properly installed Inspect support structures for proper integrity and allowance for thermal expansion. Internal inspections: Visually inspect all visible pressure vessel and tanks surfaces for corrosion, material thinning, deposits, and weld cracking. Certified American Society for Non-Destructive Testing (ASNT) Level II technicians shall perform non-destructive tests (NDT) using the wet fluorescent magnetic particle (WFMT), ultrasonic testing (UT), and any other necessary non-destructive tests. Completely examine all accessible welds utilizing the WFMT test method. Properly prepare the surfaces before testing. Determine pressure vessel material thickness by UT. Thickness measurement locations shall be selected by dividing the storage tank heads into quadrants and taking measurements at each quadrant on two imaginary rings in each head (eight measurements total) . Measurement locations on the shell shall be on each of the quadrants, on four to six locations along the length of the shell (16 to 24 measurements total). The technician may recommend fewer or more tests to the owner, providing justification. Typically, the pressure vessel section containing the deaerator trays and sprays is not accessible for non-destructive testing. The experience is that this section, which is mainly exposed to steam, is less vulnerable to weld failures and material thinning than the storage section which contains condensate and make-up water. 9. Testing: The following Nondestructive testing shall be completed and document as to the location or findings with a sketch or pictures. Any adverse findings must be documented with pictures and notes in detail. All data shall be included in the final report as supporting documentation. Ultrasonic thickness testing of representative samples of all components. Obtain sufficient material thickness measurements to accurately reflect the condition of the entire boiler and condensate tank. Ultrasonic thickness testing of all areas visually noted to have corroded or eroded. Magnetic particle testing of all areas where indications of defects have been found visually. Metallurgical analysis of representative samples of boiler metal if there are indications or a record of overheating. 10. Calculations: The consultant shall calculate and report the maximum allowable working pressure rating and remaining life expectancy based on the thickness measurements, data obtained, observations and testing for the boiler and condensate tanks. ASME Code formulas must be used and references provided in the final report. Calculate and report the depletion rate of material thickness. Remaining life calculation shall be based on original material thickness, current material thickness, evaluation of other factors in the condition of the boiler. Report Requirements: Provide complete written report fully with in 14 calendar days after completion of boiler inspected Report shall contain all inspections and tests performed, findings, and recommendations. The condition of all items inspected shall be stated whether acceptable or deficient. All deficiencies shall be fully described along with recommendations for methods of correction. Provide oral report of condition of the boiler to VAMC engineering management at the conclusion of the inspection and prior to leaving the site. Provide a draft report Microsoft (MS) Word format withing 7 days of the completion of inspection for review and comment by the COR. Once approved by VA, provide MS Word format and 6 copies of final report to COR. Provide complete narrative of the history of the equipment in the plant and current conditions of the same as well as an analysis of the visual inspections and test results, photographic views of deteriorated areas and photographs to show areas identified as not acceptable for continued service or requiring repair. Provide calculations for remaining life based on calculated present maximum allowable working pressure vs. original maximum allowable working pressure when the boiler was new. Show locations and extent of all non-destructive testing by sketches. (Spec Writer Note: this applies to boiler, deaerator and only condensate tanks that are feed from deaerator). Describe all deteriorated areas; provide expert judgment on need for repairs and repair methods. Provide expert judgment on cost effectiveness of retaining the boiler in service. Provide expert analysis of the condition of boilers/ancillary equipment and recommended extension to useful life in years. Provide photographs and/or drawings and show where each the measurements or negative observation was taken. All safety-related deficiencies shall be immediately reported to the COTR during the inspection visit. Provide recommendations on need for re-inspections after correction of deficiencies. Cost of re-inspections shall be extra cost negotiated with VA Contracting Officer. Security: Contractor s personnel will utilize a temporary vendor s security badge throughout the duration of the inspection. Contractors are required to check in with the Energy Center Supervisor or Boiler Operator upon arrival at facility to obtain instructions, work orders and project location information.

More opportunities from Department Of Veterans Affairs → Network Contract Office 23 (36C263)

Same awarding agency

NAICS: 811310
New
Federal
J039--JLG Boom Lift Hydraulic Leak Repairs - STC (VA-27-00010304)
Solicitation # 36C26327Q0084
The Department of Veterans Affairs, Network Contracting Office 23, is issuing a sources sought notice for market research to identify qualified contractors for hydraulic repairs on a JLG Boom Lift, Model 600S, at the St. Cloud VA Health Care System in Minnesota. Under NAICS code 811310, the required services include replacing all hydraulic hoses through the cat track, replacing the hydraulic line from the pump to the block, replacing hydraulic oils, and updating the basket display decal and operator and ANSI manuals. The selected contractor must be located within a 100-mile radius and will be responsible for the pickup and delivery of the equipment to and from the St. Cloud VA campus. All repairs must be completed within three weeks of the contract award and must meet industry and manufacturer operational standards. This notice is not a formal solicitation and does not obligate the government to award a contract. Interested parties must submit their company information, including DUNS and SAM Unique Entity ID, a capability statement, and their socio-economic size classification to Contract Specialist Evan Beachy by 4:00 PM Central Time on November 04, 2026. Additionally, respondents should specify if the procurement can be handled through GSA, FSS, SEWP, or other existing contract vehicles. Responses are intended solely for planning purposes to help the government make informed acquisition decisions.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 811210
New
Federal
J065--Karl Storz Support Services IDIQ VISN
Solicitation # 36C26327Q0022
The Department of Veterans Affairs Network Contracting Office 23 is soliciting a brand-name only, five-year Indefinite Delivery, Indefinite Quantity (IDIQ) contract for OEM-certified support and service of Karl Storz OR1 Video Integration Systems across the VISN 23 Healthcare System. This requirement, managed under simplified acquisition procedures, covers multiple locations including Minneapolis, St. Cloud, Fargo, Central Iowa, Iowa City, Black Hills, and Sioux Falls. The scope of work includes preventive and corrective maintenance, replacement parts, software and firmware updates, cybersecurity compliance, and technical training for clinical and biomedical staff. The contract has a guaranteed minimum value of 300,000 dollars and a maximum lifetime cost limitation of 5,600,000 dollars. Award will be based on a comparative evaluation of price and technical factors, including vendor qualifications, cybersecurity capabilities, and service level agreement response times. The contractor must adhere to strict OEM standards, NIST calibration requirements, and VA security policies, including the submission of cybersecurity artifacts and a signed Business Associate Agreement for HIPAA compliance. Performance will be monitored via a Quality Assurance Surveillance Plan targeting 98.9 percent operational uptime and 99 percent response time rates. Offers are due by November 11, 2026, and must include a signed SF 1449, completed pricing schedules, and proof of OEM certification for technicians.
Electronic and Precision Equipment Repair and Maintenance

POSTED

2 days ago

DEADLINE

in 13 days
View Details
NAICS: 238330
New
Federal
Replace Operating Room 5 Flooring
Solicitation # 36C26327Q0019
Solicitation 36C26327Q0019 is a Service-Disabled Veteran-Owned Small Business set-aside for the Department of Veterans Affairs, Network Contracting Office 23. The project involves providing all labor, materials, tools, and supervision to remove and replace the flooring and subflooring in Operating Room 5 (Room 4211, Building 1W) at the Des Moines VA Medical Center in Iowa. The work must be completed within 120 calendar days following the Notice to Proceed. Award will be granted to the responsible, eligible quoter who submits the lowest-priced acceptable quotation that meets all solicitation requirements, provided the price is determined to be fair and reasonable. Key technical requirements include conducting asbestos survey testing, adhering to the Architectural Design Manual, and utilizing certified installers through INSTALL or a comparable four-year apprenticeship program. The contractor must provide a floor tile mockup of 100 square feet to establish quality standards and comply with strict packaging and marking regulations for asbestos waste and HEPA filters. Administrative requirements include the submission of an Accident Prevention Plan and Site-specific Safety Plan for COR approval, as well as the provision of payment bonds or irrevocable letters of credit for contracts exceeding 35,000 dollars. The contract is subject to the Davis-Bacon Act and Buy American requirements, with specific limitations on subcontracting to ensure a minimum of 15 percent of the work is performed by the prime SDVOSB contractor.
Flooring Contractors

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 238220
New
Federal
J045--Glycol Loop Flushing - NWI
Solicitation # 36C26327Q0060
Solicitation 36C26327Q0060 is a firm fixed price request for quotation issued by the Department of Veterans Affairs Network Contracting Office 23 for the flushing, cleaning, and recharging of two closed-loop glycol heating systems, specifically the Surgery and Microbiology loops, at the Omaha VA Medical Center. The project requires the contractor to provide all labor, materials, equipment, and disposal handling to restore the systems to a stable operating condition using propylene glycol-based heat transfer fluid. The anticipated period of performance runs from November 1, 2026, to October 31, 2027, with the initial service required within 30 calendar days of award and a second identical service performed approximately 12 months later. Work must be conducted during normal business hours when temperatures exceed 40 degrees Fahrenheit and must comply with NFPA-99, ASHRAE 170, CMS, JCAHO, and VA HVAC Design Manual standards. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with strict limitations prohibiting the contractor from paying more than 50 percent of the government-paid amount to non-certified SDVOSB or VOSB firms. Award will be based on a comparative evaluation of price, technical quality, past performance, and veterans involvement. Key deliverables include pre-flush fluid sampling reports, system volume calculations, refractometer readings, and disposal manifests. Following Amendment 0001, the response deadline has been extended to November 10, 2026. Proposals must be submitted electronically to the contracting officer and include separate volumes for administrative documents, technical and past performance narratives, a subcontracting statement, and a labor standards statement confirming compliance with Service Contract Labor Standards.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 12 days
View Details
NAICS: 236220
Federal
PN: 438-21-403, Renovate First Floor Kitchen (SF)
Solicitation # 36C26326B0020
Solicitation 36C26326B0020 is a Firm-Fixed-Price contract issued by the Department of Veterans Affairs, Network Contracting Office 23, for project 438-21-403 to renovate the first floor kitchen at the Sioux Falls VA Medical Center in South Dakota. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220, with an estimated construction magnitude between 10 million and 20 million dollars. The scope of work includes comprehensive demolition, site work, and architectural, structural, mechanical, and electrical improvements, as well as the installation of owner-furnished equipment. The performance period is 550 calendar days from the Notice to Proceed, and work must be phased to ensure the existing second-floor kitchen remains operational for inpatient meals. The award will be granted to the responsible bidder offering the most advantageous price. Bidders must provide a bid guarantee of at least 20 percent of the bid price, capped at 3 million dollars, and submit performance and payment bonds for 100 percent of the contract amount within ten days of award. Technical requirements include strict adherence to OSHA and VA regulations, VHA Pre-Construction Risk Assessment (PCRA) and Infection Control Risk Assessment (ICRA) protocols, and ADA standards. Additionally, the contractor is responsible for managing hazardous material abatement, specifically for asbestos in Building 5, and must comply with Davis-Bacon Act wage determinations and Buy American requirements.
Commercial and Institutional Building Construction

POSTED

8 days ago

DEADLINE

in 6 days
View Details
NAICS: 621330
Federal
VA Police Psychological Evaluations
Solicitation # 36C26327Q0038
Solicitation 36C26327Q0038 is a request for quotes issued by the Department of Veterans Affairs Network Contracting Office 23 for professional psychological evaluation services at the Minneapolis VA Health Care System. The contract is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 621330. The scope of work requires the contractor to provide pre-employment, periodic annual, and directed Fitness-for-Duty evaluations for VA Police Officer applicants and incumbent officers in accordance with VHA Directive 0730(1). The anticipated award is a single Firm Fixed Price contract with a base period from March 1, 2027, to February 29, 2028, and four subsequent option years. The government will award the contract based on the Lowest Price Technically Acceptable (LPTA) method, evaluating technical acceptability and past performance from the last three years. Offerors must be registered in the System for Award Management (SAM) and the SBA certification database. Key requirements include strict adherence to HIPAA and HITECH Act regulations for protected health information, the submission of invoices through the Tungsten Network, and the provision of active professional licenses for all evaluators. Quotes are due by 12:00pm Central time on November 6, 2026, and must include a technical proposal, past performance references, and a completed pricing schedule.
Offices of Mental Health Practitioners (except Physicians)

POSTED

8 days ago

DEADLINE

in 8 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS