Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on January 22, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J045--TAB DEFICIENCY REPORT AND REPAIRS DC VAMC SITE VISIT 1/27/26 @9AM DC VAMC. SDVOSB SET-ASIDE

Closed
36C24526Q0175Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561210
New
Federal
Z1DA--B170 Window Recaulking Services
Solicitation # 36C25627Q0022
Solicitation 36C25627Q0022 is a total Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside for window recaulking services at the Eugene J. Towbin Veterans Healthcare Center in North Little Rock, Arkansas. The project aims to prevent water infiltration into rooms G101A, G101B, and GF100 by repairing gaps between the wall and TPO membrane in Courtyards 1B and 1C of Building 170. The scope of work includes inspecting the TPO for damage, installing termination bars with compatible fasteners, applying specialized polyether or polyurethane sealants to create a continuous seal along the entire curtainwall interface, and replacing missing or damaged face caps. The contractor is responsible for providing all labor, materials, and equipment, including the movement of approximately 70 pavers and adherence to strict quiet hours and facility access protocols. The contract has a period of performance of 30 days following the issuance of the Notice to Proceed, with an anticipated award date around November 1, 2026. Evaluation is based on a best-value determination considering four factors: Approach and Quality Management, Professional Qualifications and Specialized Experience, Past Performance, and Price. Factors I, II, and III are equal in importance and collectively equal to the weight of the price. Proposals must be submitted as a single PDF under 10MB in Arial 11 font to the designated contracting specialist by October 29, 2026. Compliance with Davis-Bacon Wage Determination AR20260032 and VA Master Spec 07 54 23 is required, and a 10-year manufacturer warranty on sealants must be provided. Performance and payment bonds are not required.
256-NETWORK Contract Office 16 (36C256)

POSTED

about 11 hours ago

DEADLINE

in 8 days
NAICS: 561210
New
Federal
Facility MGT Contracting Division (PQFA) Recurring Service 2026 Industry Day
Solicitation # PQFAIndustryDay
The General Services Administration, through the PBS Facility Management West Branch A, has issued a sources sought notice for the Facility Management Contracting Division (PQFA) Recurring Service 2026 Industry Day. This initiative is designed to identify qualified small businesses for upcoming recurring service contracts across Colorado, South Dakota, Alaska, Washington, Wyoming, Utah, Montana, and Idaho. The scope of work encompasses several key service categories, including custodial services, landscaping, waste management and recycling, and facilities engineering. The engineering component specifically covers high voltage electrical systems, mechanical, plumbing, HVAC, energy management, fire protection, life safety, architectural systems, and snow removal. Contractors will be responsible for the efficient operation and both scheduled and unscheduled maintenance of these systems, with a requirement for quality control and record keeping utilizing a national computerized maintenance management system. The Industry Day event consists of a GSA presentation on November 17, 2026, followed by one-on-one capability sessions on January 13, 2027. Interested firms must register by November 9, 2026, by submitting a capability statement of no more than five pages. Required submission details include company information, Unique Entity ID, socioeconomic status, affiliate or teaming partner information, and summaries of one to three similar past projects. While this notice is for informational and planning purposes and does not constitute a formal solicitation or commitment by the government, it serves as the primary mechanism for industry engagement regarding these upcoming facility management opportunities in the Pacific Northwest and Rocky Mountain territories.
Pbs Facility Management West - Branch A

POSTED

about 11 hours ago

DEADLINE

in 19 days
NAICS: 561210
New
Federal
Indefinite Delivery/Indefinite Quantity (IDIQ) Custodial, Pest Control, and Grounds Maintenance Service Contract at U.S. Marine Corps Air Station (MCAS) Iwakuni, Japan
Solicitation # N4008426R1026
Solicitation N4008426R1026 is an Indefinite Delivery/Indefinite Quantity (IDIQ) contract issued by NAVFACSYSCOM Far East for custodial, pest control, and grounds maintenance services at U.S. Marine Corps Air Station (MCAS) Iwakuni, Japan. The tentative period of performance spans from April 22, 2027, to October 21, 2035, consisting of a base year and seven option periods. The contract utilizes a Lowest Price Technically Acceptable (LPTA) source selection process, evaluating proposals based on price and three non-cost factors: safety, experience, and past performance. Offerors must provide a five-year safety record and a detailed Safety Management System to be deemed acceptable. Contractors must adhere to strict installation security protocols, including vetted access control and a Memorandum of Understanding regarding photography and drone usage, as certain images of the flight line and critical infrastructure are classified as Controlled Unclassified Information. Technical requirements include maintaining a Cybersecurity Maturity Model Certification (CMMC) Level I self-assessment at the time of award. Payments will be processed via electronic funds transfer through the Wide Area WorkFlow (WAWF) system. Proposals must be submitted electronically via the Procurement Integrated Enterprise Environment (PIEE) portal, with a final response deadline of November 3, 2026.
Navfacsyscom Far East

POSTED

about 11 hours ago

DEADLINE

in 12 days
NAICS: 561210
New
Federal
EAGLE Fort Riley KS W519TC-26-R-A054
Solicitation # W519TC26RA054
Solicitation W519TC-26-R-A054 is a competitive request for proposal for logistics support services at Fort Riley, Kansas, including maintenance, supply, and transportation. This acquisition is a 100 percent small business set-aside restricted to Enhanced Army Global Logistics Enterprise (EAGLE) Basic Ordering Agreement holders under NAICS code 561210. The resulting contract will be a Cost Plus Fixed Fee task order featuring a 60 day transition period, a 12 month base period, and four one year option periods, with an additional six month option, totaling five years and six months of performance. The scope of work encompasses comprehensive logistics functions, including materiel maintenance for the 1st Infantry Division and 79th Ordnance Battalion, supply operations for the Installation Supply Division, and transportation services including fleet management and cargo movements. Performance is measured against specific Performance Requirements Summaries and a Quality Assurance Surveillance Plan. Award will be based on a best value source selection process where the government seeks the lowest total evaluated price from a responsible offeror determined to be technically acceptable with substantial confidence in past performance. Key administrative requirements include the submission of proposals via electronic upload by October 28, 2026, and the use of Wide Area Workflow for invoicing. Contractors must adhere to strict security protocols, including Secret security clearances for required personnel and compliance with various military packaging and marking standards. Pricing must be submitted using a specific cost price matrix covering transition, project management, and functional division labor, alongside government-estimated other direct costs.
W6QK Acc-Ri

POSTED

about 11 hours ago

DEADLINE

in 7 days
NAICS: 561210
New
SLED
ON CALL FACILITY MAINTNANCE SERVICES
Solicitation # 2027-06
Española Public Schools is soliciting proposals under RFP 2027-06 for a non-exclusive, on-call agreement to provide facility maintenance services across various district-owned and operated facilities in New Mexico. The selected contractor will provide skilled and general maintenance personnel, including carpenters, painters, HVAC technicians, and licensed electricians and plumbers, as well as all necessary supervision, tools, and equipment on an as-needed basis. Key services include general and preventative building maintenance, drywall repairs, door and hardware work, and minor plumbing and electrical tasks. The district expects access to approximately 10 to 15 maintenance personnel, though no minimum number of hours or expenditures is guaranteed. Proposals are due by November 3, 2026, at 11:00 AM MST and must be submitted electronically via the designated procurement platform. Evaluation is based on a 100-point scale, with 25 points allocated to the cost proposal and 20 points to company experience and past performance. Award will be granted to the responsible offeror deemed most advantageous to the district. Requirements for submission include a detailed technical proposal, a cost proposal with labor rate schedules, and various certifications, including conflict of interest, debarment, and campaign contribution disclosures. The contractor must comply with New Mexico public works prevailing wage obligations, building codes, and district safety and background-check policies.
Espanola Public Schools

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 561210
New
Federal
H379 Mann-Grandstaff VA Medical Center Kitchen Equipment Regular Maintenance and Repairs
Solicitation # 36C26027Q0088
Solicitation 36C26027Q0088 is a combined synopsis and request for quotation for a hybrid Firm-Fixed-Price and Time-and-Material contract to provide comprehensive preventive maintenance, corrective repairs, emergency services, testing, calibration, and technical support for kitchen and dietary equipment at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The requirement includes a base period with two option years, covering all labor, materials, and tools necessary to ensure the continuous operation of food service equipment. Performance must adhere to OEM specifications, VA Directives, VHA policies, and standards from NFPA, OSHA, and the FDA. The contract establishes strict response timelines, requiring emergency or high-priority repairs to be addressed within 24 hours or by 8:00 am the next business day, while standard repairs must be completed within 72 hours. Award will be based on a comparative evaluation of technical capability, past performance, and price, with the government reserving the right to accept an offer other than the lowest price if it provides additional benefits. Offerors must submit a four-part proposal consisting of an executed SF1449, pricing, technical capabilities, and past performance documentation to the contracting officer by the specified deadline. Invoicing is to be handled electronically via the Tungsten Network.
260-NETWORK Contract Office 20 (36C260)

POSTED

1 day ago

DEADLINE

in 15 days

General Info

Contract Value

$95,500

NAICS

561210 - Facilities Support Services

Place of Performance

WASHINGTON DC VAMC 688, WASHINGTON, DC, 20422, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

4

36C24526Q0175 RFQ Investigation of Tabs DC VAMC SDVOSB Set-Aside

DOCX, High priority: read this first3 pages · rfq
High

RFQ 36C24526Q0175 Investigation of Tabs DC VAMC SDVOSB Set-Aside

PDF, High priority: read this first68 pages · rfq
High

Wage Determination No. 2015-4281 for Service Contract Act FY26

PDF, High priority: read this firstwage-determination
High

DC VAMC Campus Map

PDF, Low priority1 page · other
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
JOHN RITTERCONTRACTING OFFICER

Full Description

Show more
SOURCE SOUGHT
THIS IS A SOURCES SOUGHT ANNOUNCEMENT IS FOR INFORMATION & PLANNING PURPOSES ONLY; IT IS NEITHER A SOLICITATION ANNOUNCEMENT NOR A REQUEST FOR PROPOSALS OR QUOTES AND DOES NOT OBLIGATE THE GOVERNMENT TO AWARD A CONTRACT. A CONTRACT MAY NOT BE AWARDED AS A RESULT OF THIS SOURCES SOUGHT ANNOUNCEMENT. REQUESTS FOR A SOLICITATION WILL NOT RECEIVE A RESPONSE. RESPONSES TO THIS SOURCES SOUGHT MUST BE IN WRITING. THE PURPOSE OF THIS SOURCES SOUGHT ANNOUNCEMENT IS FOR MARKET RESEARCH TO MAKE APPROPRIATE ACQUISITION DECISIONS AND TO GAIN KNOWLEDGE OF POTENTIAL QUALIFIED SERVICE DISABLED VETERAN OWNED SMALL BUSINESSES, VETERAN OWNED SMALL BUSINESSES, 8(A), HUBZONE AND OTHER SMALL BUSINESSES INTERESTED AND CAPABLE OF PERFORMING THE WORK. DOCUMENTATION OF TECHNICAL EXPERTISE MUST BE PRESENTED IN SUFFICIENT DETAIL FOR THE GOVERNMENT TO DETERMINE THAT YOUR COMPANY POSSESSES THE NECESSARY FUNCTIONAL AREA EXPERTISE AND EXPERIENCE TO COMPETE FOR THIS ACQUISITION. RESPONSES TO THIS NOTICE SHALL INCLUDE THE FOLLOWING: (A) COMPANY NAME (B) ADDRESS (C) POINT OF CONTACT (D) PHONE, FAX, AND EMAIL (E) DUNS NUMBER (F) CAGE CODE (G)TAX ID NUMBER (H) TYPE OF SMALL BUSINESS, E.G. SERVICES DISABLED VETERAN OWNED SMALL BUSINESS, VETERAN-OWNED SMALL BUSINESS, 8(A), HUBZONE, WOMEN OWNED SMALL BUSINESS, SMALL DISADVANTAGED BUSINESS, OR SMALL BUSINESS HUBZONE BUSINESS AND (I) MUST PROVIDE A CAPABILITY STATEMENT THAT ADDRESSES THE ORGANIZATIONS QUALIFICATIONS AND ABILITY TO PERFORM AS A CONTRACTOR FOR THE WORK DESCRIBED BELOW.
Inspection, Safety Device Testing and Calibration Boiler Plant Burners, Controls, Instruments, Data Management and Inspections Perry Point VAMC Perry Point, MD 21902
NACIS: 811310 PSC: J044
1. Introduction:
Most Department of Veterans Affairs Medical Centers (VAMC) have a central boiler plant to provide steam for heating and air conditioning, domestic hot water, kitchens and sterilization. Some medical centers have laundries that utilize steam.
Boiler plant safety, reliability, efficiency and equipment longevity are paramount concerns of VAMC management. Malfunctioning burners or controls can cause catastrophic events resulting in injuries and death and massive property damage. Inaccurate or inadequate data management and monitoring systems can fail to warn of unsafe or inefficient performance. Regular inspections, testing and calibration by expert technicians are an essential part of a program to address these concerns.
This Statement of Work describes the requirements for the inspection, testing and calibration of the boiler plant burners, controls and instruments by qualified technicians.
A separate Statement of Work document covers the inspections of the boilers and boiler plant equipment by Qualified Professional Inspectors.
2. Technician Qualifications:
Technicians shall have completed at least a one-year trade school and have five years successful experience in this field. The experience shall be largely with institutional and industrial boiler plants similar in design to the VAMC plant. The VAMC facility manager/engineer may define and accept equivalent qualifications.
Technicians shall demonstrate familiarity with and ready access to the current versions of the following references:
NFPA 85, Boiler and Combustion Systems Hazards Code.
VHA Boiler Plant Safety Device Testing Manual, 3rd Edition.
Technicians shall be equipped with portable electronic flue gas analyzers and other test instruments necessary for the required tests and calibrations, all calibrated within one month of the site visits. At facilities with programmable digital controls, the technicians must be capable of programming the controls and have the appropriate hardware and software for this.
3. Inspection, Testing and Calibration Requirements:
Technicians shall provide all tools and labor necessary to perform inspection, tuning, testing, calibrating, and adjustments of burners and boiler and boiler plant controls as specified below. This shall be done every six months in accordance with a schedule provided by VAMC. VAMC may extend the schedule for burners in limited service.
Instrumentation, monitoring and data management systems as listed below shall be calibrated every six months.
Provide at least two weeks notice to the Contracting Officer s Representative (COR) prior to performing the work. Work cannot be scheduled during heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Work must be conducted when the COR or his/her designate is available on site to monitor the work.
VAMC will have the boilers that are to be serviced prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale; fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation (pressure/temperature correction factors provided, if applicable); boiler steam flow, stack temperature and flue gas oxygen instruments operating.
VAMC will comply with any other requirements of the test personnel that are considered reasonable by VAMC and have been presented in writing at least two weeks prior to the scheduled testing.
The inspections, testing and calibrations shall comply with:
The recommendations and requirements of VHA Boiler Plant Safety Devices Testing Manual, 5th Edition. The written recommendations of the equipment manufacturers.
The requirements and recommendations of NFPA 85 Boiler and Combustion Systems Hazards Code including applicable appendices.
Burner performance requirements in this document.
A summary of the work is as follows:
Review boiler plant log sheets and alarm and trouble reports.
Review records that show combustion performance (flue gas oxygen and carbon monoxide).
Perform overall visual inspection of systems. Verify that systems comply with referenced codes and VAMC requirements stated in this contract.
Test and record the operation and set points of all burner/boiler safety interlock devices. Refer to list below. Verify that the set points and operating points are within approximately 20% of normal operating parameters. Make adjustments as necessary and record the new settings. The operation of a device must result in burner shutdown and/or proper alarm operation.
Operate burner(s) on each fuel from low fire to high fire and back to low fire in at least six increments and record combustion performance (flue gas oxygen, carbon monoxide, NOx where applicable), fuel train pressures, atomizing train pressures, burner pressures, stack temperatures, boiler steam output.
Compare the combustion performance data with VAMC requirements (see below) and previous readings. If necessary, make adjustments to the fuel flow and combustion air controllers, control valves and dampers to obtain the required performance. Record the new performance data.
Verify accuracy of instrumentation listed below. Verify that all devices are properly selected for the application in terms of type, size, set point range, performance, code approval. Calibrate all instruments that are not within manufacturer s specifications for accuracy.
Immediately inform COR of any recommended repairs or modifications.
All of interlocks and safety devices to be inspected and tested on each boiler/burner/equipment, are contained in the VHA Boiler Plant Safety Devices Testing Manual, 5th Edition, along with testing procedures.
Required burner performance (natural gas and fuel oil):
Turndown (ratio of maximum and minimum firing rates): 10/1 8/1 5/1 4/1 (Refer to original burner specification).
Achieve, but do not exceed, boiler maximum steam flow output rating. Measure fuel input at minimum and maximum firing rates.
Maximum carbon monoxide: 200 parts per million (ppm)
Maximum NOx: _____ (Refer to original burner specification).
Flue gas oxygen: 2.5 4.2% (Up to 5.2% at loads below 40% of maximum steam output; no upper limit at minimum firing rate; oxygen can be one percentage point higher on oil firing on single-point positioning systems).
Flue gas oxygen (low excess air burners): 1.0 2.0% (Up to 2.5% at loads below 40% of maximum steam output; no upper limit at minimum firing rate; oxygen can be one percentage point higher on oil firing on single point positioning systems).
No visible smoke, except on heavy oil fuel maximum opacity is 20%. Comply with local emissions regulations.
*Copies of the applicable emissions regulations must be available in the boiler plant office.
Flames shall be stable with no pulsations, shall be retained near burner, no blowoff or flashbacks, no constant flame impingement on refractory or waterwalls.
List of instrumentation and controls to be inspected and calibrated:
Steam flow transmitters (all).
Steam flow recorders/computer readout.
Flue gas oxygen sampling, analyzing and recorder/computer readout.
Boiler and economizer stack temperature transmitters and recorder/computer readout.
Master steam pressure and combustion controllers.
Boiler outlet draft controllers.
Boiler water level controllers.
Feedwater deaerator and condensate storage tank water level controllers including overflow.
All pressure and temperature sensors and transmitters.
All signal processing and readout devices.
4. Report Requirements:
Provide complete written report of the inspection fully describing all tests performed, all findings, and recommendations. The report shall have two sections the first section will be in a table form that with four columns: The first column labeled FUNCTION did the device pass or fail. The second column labeled Device list the device number and description in accordance with the VHA Boiler Plant Safety Devices Testing Manual,5thd Edition. The third labeled Deficiencies-Recommendations The fourth column labeled corrective actions list any corrective actions taken during the inspection. The next section shall be in paragraph/bulleted form and list each device individual in accordance to the VHA Boiler Plant Safety Devices Testing Manual, 5th Edition. Plus the section must reference the correct Master Specification and Standard Detail for that device. See sample below.
5.1. Condensate Storage Tank High Water Alarm Purpose: High water level may be an indication of condensate transfer pump failure that could lead to low water condition in the feedwater deaerator and in the boilers. There may be a failure of make-up water controls. Recommended set point: 4 inches below overflow level and 2/3 of tank height. Potential hazards due to failure of high water alarm: Feedwater deaerator running dry and, consequently, boiler feed pumps running dry will cause overheating and damage to pumps and potential for plant shut down. Failure of make-up water controls (in open position) could lead to significant cost from waste of water and condensate from the tank overflow if this occurs over a long time period.
Recommended type of device: Conductivity probe type switch. Float type switches have high failure rate in this application where they are exposed to flash steam that causes seals to harden and prevent float movement. VA Master Specification section: 23 50 11 (old 15625). www.va.gov/facmgt/standard/ VA Standard Detail: SD232111-05.pdf www.va.gov/facmgt/standard/ Failure rate of float types: 48% (BEI study of VA boiler plants). Make and Model: Mercoid Float Did it function properly: No Category & Action Time Limit: Upon Failure or Within 5 Years Comments: Float type switches are not allowed for high water alarms. The VA recommended switch type is a conductivity probe type switch. Install the VA recommended switch and set to alarm at 2/3 of the tank height. There are valves that can isolate this alarm. These valves must be made lockable only in the operating position.
Furnish report within one week of each facility inspection in Microsoft Word format by email to the COTR and to the VA Headquarters office designated. Provide hard copies of data sheets and flue gas analyzer strip printouts to the COTR within one week of visit.
All safety-related deficiencies shall be immediately reported to the COTR, Boiler Plant Supervisor and/or Chief Engineer during the inspection visit.
Addendum


More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541310
New
Federal
C1DA--Renovate Specialty Clinics on 2nd
Solicitation # 36C24526R0101
Solicitation 36C24526R0101 is a request for Architect/Engineer services to provide a turnkey design package for the renovation of approximately 16,530 square feet of specialty clinic space on the second floor of the Beckley VAMC in West Virginia. The project focuses on creating an updated central check-in and waiting area, improving wayfinding and traffic flow to support a one-stop care approach, and upgrading systems in a facility originally constructed in the 1950s to meet current building codes and VA guidelines. Key deliverables include construction drawings across all disciplines, schematic designs, life-cycle cost analysis, preconstruction risk assessments, and detailed phasing and infection control plans to manage work within an occupied facility. While the A/E service value is not specified, the resulting construction budget is not to exceed 19,912,000 dollars. This procurement is a 100 percent Service-Disabled Veteran-Owned Small Business set-aside conducted under the Brooks Act. Selection is based on qualifications, with a shortlist of three to five firms chosen for interviews. The primary evaluation factors are professional qualifications, specialized experience in healthcare renovation, and past performance, followed by capacity to accomplish the work, organization and quality control, and geographic knowledge of the locality. Interested firms must be registered in SAM and certified in the SBA Veteran Small Business Certification database. The submission deadline for SF 330 qualifications packages has been extended to November 13, 2026, at 2:00 PM EST, with submissions required in PDF format and limited to 5MB per email attachment.
Architectural Services

POSTED

about 11 hours ago

DEADLINE

in 23 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS