Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on April 20, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J061--Sources Sought for Emergency Generator Service

Closed
36C24121Q0358Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 8 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 13 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

VA Maine HCS 1 VA Center, Augusta, ME, 04330-6796, USA

Set-Aside

NONE

Documents

1

36C24121Q0358.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Kenya MitchellContracting Specialist

Full Description

Show more
Page 7 of 7 Department of Veterans Affairs Veterans Health Administration (VHA) Sources Sought Notice Obtain a qualified vendor to provide Emergency Generator Service at the Maine HCS This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of your company s offered services and capabilities. The Government will not pay any costs for responses submitted in response to this Source Sought Notice. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the service requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought, please ensure that you indicate your DUNS number on your response. The Veterans Health Administration (VHA) is seeking to obtain a qualified vendor to provide Emergency Generator Service Contract at the Maine HCS listed below. The standard of services shall be of quality; meeting or exceeding those outlined in the general performance work statement as described below. Refer to the Statement of Work section below for the requested service description. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. STATEMENT OF WORK Inspection, Preventative Maintenance, and Repair of Emergency Generators INTRODUCTION The work includes but is not limited to: provide all equipment, fluids, tools, labor, and to perform regular and periodic examination as stated below, semi-annual and annual preventative, 24 hour emergency call back diagnosis and repair of the emergency generator systems at the VA Medical Center in Augusta, ME located at 1 VA Center. The proposed term of the service is one year from the date of the award. There will be four additional renewal option years to be re-evaluated and awarded annually. DEFINITIONS/ACRONYMS Engineer (ing) - Supervisor or designee. CO - Contracting Officer COR - Contracting Officer's Representative. WHEN Hours- Weekends, Holidays, Evenings, and Nights. Anytime outside of Normal Business Hours (Monday-Friday 7:00am-4:30pm) ESR - Engineering Service Report. A documentation of the services rendered for each incidence of work performance under the terms and conditions of the contract. Authorization Signature - COR signature; indicates work status is accepted as stated in ESR. VAMC - Department of Veterans Affairs Medical Center. PM- Preventive Maintenance EQUIPMENT TABLE Make: Model: S/N: Location: Magnum Power XQ570 XQ570HME500131 Bangor Magnum Power MMG330 1409605 Bldg 244 Generac MDG250 3002791927 Bldg 202-200 Generac MDG150 3002791925 Bldg 202-200 Generac MDG100 3002876808 Bldg 202-200 Ingersoll Rand G40 4FVCBAA78440089 Bldg 229 Caterpillar C9 C9E01997 Bldg 244 (*) Caterpillar 3459 CCB00984 Bldg 200-195 (*) Caterpillar 3412 81z08706 Bldg 200-195 (*) Caterpillar XQ570 XQ570LME500127 Lewiston Caterpillar MMG330 3002791927 Bldg 249 Caterpillar C13 T3200659 Bldg 210 (*) Caterpillar C27 2A300654 Bldg 244 (*) Caterpillar 3406 4ZR01263 Bldg 238 (*) (*) - Critical Joint Commission Generators that include 2 replacement batteries/unit in Second Yr Check Mobile Generators are subject to change location SCOPE This project includes the following tasks: 4.1 Task 1 Scheduled preventative maintenance: Provide regularly scheduled annual and semi-annual preventative maintenance services for all the emergency generator systems at the Medical Center noted in the equipment table. Service includes the following at the minimum or Manufacture requirements whichever is greater. SEMI-ANNUAL CHECK (ENGINE NOT RUNNING) Conduct visual check around the generator. Check the battery s liquids specific gravity, do battery load test, top up\fill if necessary. Clean battery terminals and lugs. Check all V and fan belts to make sure there are no hair line cracks on the belts, replace if cracked or worn. Check and adjust tension on all V and fan belts. Check coolant level and top up\fill if necessary. Check specific gravity of coolant. Replenish as necessary to maintain manufacturers recommended level and specific gravity of coolant additive. Check operation and components of water jacket heating system. Test fuel day tanks for water. Record water levels in tanks. Drain condensate from exhaust condensate trap. Clean air filter element. Inspect all fuel, oil, and water piping for secure mounting. Inspect exhaust piping and muffler insulation. Inspect crankcase breather tube. Check all control panel indication LED s. SEMI-ANNUAL CHECK (ENGINE RUNNING) Turn off the generator circuit breaker and run the generator unloaded for 15 minutes. Check the generator for unusual conditions, such as: excessive vibration, excessive black or white smoke. The following indicators on the control panel also need to be checked and verified while the generator is running: fuel level, oil pressure, water temperature, rpm, voltage, and frequency. With the engine running and the generator circuit breaker open: Jumper water temperature switch Jumper oil pressure switch Jumper coolant low-level switch Press emergency stop push button. Each time the switch is jumped or the emergency stop button is pressed the engine should stop and the corresponding failure lamp should illuminate. Reset the shut-down mechanisms after each test. Read and record verify all engine and alternator indicators. Check exhaust for excessive black or white smoke. (See manufacture s manual) Check turbocharger for vibrations, check for any abnormal noise during operation. Check generator bearing for noise and overheating. Check exhaust manifold, muffler, and piping for leaks and secure mountings. Check fuel day tank for overheating. Check exhaust backpressure at the Diesel particle filter (Dpf.), if above 24 Inches H20 / 6 kPa, Dpf filters to be removed and cleaned. Or in accordance with the manufacturer s recommendations. SEMI-ANNUAL CHECK (ENGINE STOPPED AFTER RUNNING) Inspect engine water, fuel, and oil systems for leaks while engine is hot. Fill out maintenance checklist and report deficiencies. Confirm that circuit breaker is in closed position, and generator is set in automatic. SEMI-ANNUAL CHECK (ENGINE NOT RUNNING) Change fuel and air filters every 250hrs or once a year whichever is sooner Change coolant filters every 250hrs or once a year whichever is sooner Inspect battery charging Alternator and V belt. Inspect engine and generator wiring harness for wear and damages. Inspect supports and spring isolators for soundness and stability. Inspect unit thoroughly for loose fasteners. Clean radiator air passages and exhaust air ducts. Clean intake louvers and ducts. Inspect unit for corrosion. Remove any corrosion, prime and paint. Inspect fan drive idler pivot arm assembly and shock absorber. Inspect Belt driven fan hub. Take fuel oil samples, analyze and report composition and cleanliness.ANNUAL CHECK (ENGINE RUNNING) Perform complete semi-annual Engine running schedule (Section 2). ANNUAL CHECK (ENGINE STOPPED AFTER RUNNING). Perform complete semi-annual Engine stopped after running schedule. (Section 3). Change crankcase oil and filters every 250 hours or once a year, whichever is sooner. Fill out maintenance checklist and report deficiencies. Confirm that circuit breaker is in closed position, and generator is set in automatic. OUT YEAR CHECKS Second Year Checks: Inspect Turbocharger: Inspection to include bearings, seals, exhausts, and air impellers. Change all gasket and seals. Inspect Rotating rectifier: Inspect and clean rotating rectifier per manufacturer s recommendations. If replacement is warranted, provide a written recommendation to the COR for action to include all material and labor. Replace batteries: Replace batteries with minimum Caterpillar Deep Cell batteries per manufacturer s recommendations. Provide two (2) batteries for each generator. Replace cooling system temperature regulators with seals. Task 2 Repairs and Emergency Call Back Service: Contractor shall have technician on site within two (2) hour, during normal business hours and three (3) hours, during WHEN hours of request by telephone or otherwise from contacting officer, Chief Engineer and/or designees for emergency services. Response will be in the event of a shut down or emergency trouble developed between regularly scheduled maintenance services. Overtime emergency call back service shall be limited to minor adjustments and repairs required to protect and provide immediate safety of the equipment and persons in and about the generators. The contractor shall be responsible to make all repairs and adjustments necessary. Repairs are defined as unscheduled work required to (1) prevent a breakdown or malfunction of an item of equipment; (2) put a system or a subsystem back in service after a breakdown or malfunction. The emergency generator systems of the medical center must remain operational 24/7. Alternative measures for providing equivalent emergency power during repairs are the responsibility of the VA. Repairs shall be completed within 24 hours after the need for repair has been identified by the contractor or by the Government. All repairs shall be in accordance with the equipment manufacturer s requirements and\or applicable laws, regulations, codes, etc. An extension may be granted at the discretion of the COR on a case by case basis. Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible. The Contractor shall furnish all supplies, materials, and equipment to perform regularly scheduled service, emergent service, and repairs. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. The Contractor shall have and maintain on hand locally a supply of spare parts enough for normal maintenance and expedient emergency repairs of the generators. Parts greater than $500 to be VA funded but installation provided free of charge by contractor. Space is not available for storage of equipment or materials. If needed the Contractor should make arrangements for storage as part of this contract. PERFORMANCE REQUIREMENTS The Contractor, under this Scope of Work (SOW), will be responsible for all supervision, labor, tools, lubricants, cleaning products, and manufacturer replacement parts and equipment required to carry out all services as outlined in this SOW. The medical center is considered a critical facility; therefore, all emergency generator equipment shall be kept in first class condition and proper working order 24/7. The Contractor will be required to evaluate the existing equipment and provide the COR with a proposed maintenance schedule in advance of service. Contractor must submit to the COR for review, work sheet/checklist that will be used for performing and documenting maintenance service. All personnel working in the vicinity shall wear and /or use safety protection equipment and exercise the appropriate cautions while all work is performed. Any questions or injuries shall be brought to the attention of the COR, and Safety Manager or Safety Officer. Material data sheets (MDS)shall be provided by the contactor for all HAZMAT materials. Copies will be provided to the COR for approval. No materials will be allowed to be brought on site until they have been submitted and approved by the COR in advance. Preventive maintenance for Standby generator sets to be performed by a technician or mechanic, who is manufacturer certified to work on Caterpillar and other Diesel manufactured emergency generators as listed above. All off site calibration of generator components to be performed by an authorized Caterpillar repair location, a calibration certificate for each calibrated component must be issued. Perform all annual preventive maintenance procedures prior to beginning out-year cycles. COR must immediately be made aware of any condition discovered that could result in equipment failure. Testing and inspection summary report shall be submitted to the COR within three days of completing all work. If any discrepancies are found with the generator system that are not covered under this scope of work, then the contractor must provide the following: Detailed report noting the discrepancy found. Bill of Materials (BOM) to include component name, quantity, part #, and assumption of price for any repair material required and material lead time. All work shall be completed during normal business hours in conjunction with the medical center regularly scheduled monthly generator testing, unless called back for emergency service outside of normal business hours. Emergency call back services shall be assumed to be completed during WHEN hours. All travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract. Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc. The services shall be completed in accordance with the latest National Electrical Code (NEC), and National Fire Protection Association (NFPA) standard, VA Standards and policies, and local and city codes. In the event there is conflict between any of the standards/codes, the more stringent standard/code shall apply. Clarification for conflicts must be requested in advance of the service rendered. Contractor shall comply in accordance with all OSHA Safety Guidelines. Upon arrival at the medical center, the Contractor shall check in with the maintenance scheduler, COR or designee. Contractor shall sign in and out in engineering during normal business hours. During WHEN hours the Contractor shall sign in and out at the Boiler Plant. While on property the contractor shall always display an appropriate contractor badge . DELIVERABLES Submittal of proposed maintenance schedule of activities for review and approval by the COR. Submittal of proposed equipment and materials to be used on site for review and approval by the COR. Submittal of Contractor safety plan and lock\out tag\out plan. Submittal of material Data Sheets (MDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center. Chemicals must be approved before they can be located on property. Submittal of all maintenance reports. Must be submitted within 3 days of service completion date. Reports should include at a minimum: Name and contact information for contractor. Name of employee performing the work. Date of work performed, and hours spent. Description of the work performed including PMI s and equipment worked on. Detailed report noting any deficiencies found. Signature of employee that performed work as well as the COR. Bill of Materials (BOM) to include component name, quantity, part #, and assumption of price for any repair material required and material lead time.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 532490
New
Federal
W038--Rental & Support Services for Wheeled Loaders w/3yard bucket
Solicitation # 36C24126Q0815
The Department of Veterans Affairs VA Maine Healthcare System Togus is soliciting quotes for the rental and support of two wheeled loaders equipped with 3-yard buckets and Fusion couplers. The equipment will be used for snow removal from parking lots at the Togus VAMC campus, with an anticipated start date of November 9, 2026. The rental is on a month-to-month basis for an undetermined duration, estimated between one and six months. Each loader must meet or exceed specifications comparable to CAT 926 or CAT 930 models, featuring 160 to 170 hp Tier 4 Final engines, ROPS/FOPS certified cabs with climate control, and four liquid-filled tires for added weight. The selected contractor must provide comprehensive 24/7 service and support, including all preventive maintenance and repairs. Repairs must be initiated within 24 hours of notification, or a replacement loader must be provided at no additional cost. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 532490. Award will be made to the technically acceptable vendor offering the lowest evaluated price, based on an evaluation of technical capability, past performance, and total price. Quotes must include a monthly rental rate and itemized delivery and pickup charges, with a submission deadline of November 2, 2026.
Other Commercial and Industrial Machinery and Equipment Rental and Leasing

POSTED

about 17 hours ago

DEADLINE

in 5 days
View Details
NAICS: 238990
New
Federal
Amendment 0001- Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting quotes for a firm-fixed-price contract to perform a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Brockton, Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The benchmark product is the Ameristar Impasse Trident system, and any proposed equal must meet all salient characteristics, including the use of corrosion-resistant, tamper-resistant hardware and a uniform transition in profile, color, and finish to the existing fence. The scope is strictly limited to the damaged sections and does not authorize any redesign or expansion of the perimeter. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award will be made to the responsible offeror determined to be most advantageous based on price, past performance, and technical capabilities. Proposals must be submitted in three separate PDF volumes covering technical approach, past performance, and pricing. Following Amendment 0001, a site visit is scheduled for November 10, 2026, and the closing date for the receipt of offers has been extended to November 13, 2026, at 1:00 PM EST.
All Other Specialty Trade Contractors

POSTED

about 17 hours ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS