J065--Code Blue Button Nurse Call (Rauland-Borg Responder 5) Patient Station Installation
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Department of Veterans Affairs Network Contracting Office 19 intends to award a sole source procurement to Beacon Communications for the installation and programming of Rauland-Borg Responder 5 Enhanced Single Patient Stations at the Rocky Mountain Regional VA Medical Center. This one-time service involves furnishing nine patient stations and nine call cords, along with the removal of obsolete devices, specifically supporting the Emergency Department Fast Track area and the PMRS/SCI-D multipurpose room K3-327. To ensure patient safety and system interoperability, all new equipment must be fully compatible with the existing Responder 5 platform to maintain seamless integration with corridor lights, nurse call consoles, and staff routing. This requirement falls under NAICS code 811210. Interested parties must demonstrate their capability to meet these needs by submitting relevant documentation to the contracting officer by 12:00 PM EST on September 1, 2026.
General Info
Agency
NAICS
Place of Performance
COSet-Aside
Documents
(3)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
This is a contract action for a one-time service to furnish, install, and program Rauland-Borg Responder 5 Enhanced Single Patient Stations and call cords and remove obsolete nurse call devices at the Rocky Mountain Regional VA Medical Center. The work supports the Emergency Department Fast Track area and the PMRS/SCI-D multipurpose room K3-327. The required equipment consists of nine (9) Rauland-Borg Enhanced Single Patient Stations, nine (9) call cords, related compatible components/materials, installation, programming, and verification with the existing Responder 5 nurse call system.
The facility has an installed Rauland-Borg Responder 5 nurse call system. The replacement patient stations, call cords, and related components must be compatible with the existing Responder 5 platform and must integrate without degradation to patient call placement, corridor light annunciation, nurse call console/PC display, cancellation, supervision, and routing to assigned staff devices. Use of non-compatible components or non-authorized installation/programming could require redesign or replacement of existing nurse call infrastructure and could create patient safety, interoperability, warranty, and support risks.
The associated North America Classification Systems (NAICS) Code is 811210 and the Business Size Standard is $34.0 Million. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. Interested parties may identify their interest and capability to respond to this requirement no later than 12:00 PM Eastern Standard Time, Tuesday, September 1, 2026. Information received in response to this notice must clearly demonstrate the capability of meeting the Government s need as stated above. Include any relevant information (specifications, cut sheets, brochures, capability statement, etc.) confirming the ability to supply the products and/or any services outlined in this notice. Responses to this notice are to be sent to christopher.hollingsworth2@va.gov. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government. The Government is not responsible for any potential costs incurred from interested parties desiring to respond to this notice.