Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on March 25, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Oracle Hardware Maintenance Support

Closed
1300972076Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

811212 - Computer and Office Machine Repair and Maintenance

Place of Performance

Patuxent River, MD, 20670, USA

Set-Aside

NONE

Documents

1

A5+-+SOW_Oracle_HW_FY22.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Air Warfare Center Air Division
Contacts2 people available
OfficePATUXENT RIVER, MD, 20670-1545, USA
Office AddressPATUXENT RIVER, MD, 20670-1545, USA

Full Description

Show more
THIS REQUIREMENT IS ADVERTISED AS SOLE SOURCE. THE NOTICE IS PUBLISHED FOR INFORMATION PURPOSES ONLY AND IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. This acquisition is being pursued on a sole source basis under the statutory authority of Title 10, U.S.C. Section 2304(c)(1), as implemented by Federal Acquisition Regulation (FAR) 6.302-1, "Only one responsible source and no other supplies or services will satisfy agency requirements." A determination by the Government not to compete this effort is solely within the discretion of the Government. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in the Federal Acquisition Regulation (FAR), Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This announcement is a request for quote (RFQ). This requirement is being synopsized as an unrestricted acquisition under the North American Industry Classification System (NAICS) code 811212, Size Standard $30 Million, PSC code 7K20. The Naval Air Warfare Center Aircraft Division (NAWCAD), located at the Naval Air Station Patuxent River, MD intends to establish a FFP contract on a sole source basis to The Jasper Group, 131 NE 7th Ave. Delray Beach, FL. 33483. Jasper is an authorized reseller of the Oracle RTPS Modular Library System for ORACLE hardware and technical support services Contractors shall provide the following: Please see attached Statement of Work. CLIN Qty Service Level Item Description Serial No. / Host Name CSI No. 1 1 B58179- (PREM-SPRT-SYS) StorageTek LTO tape drive: 1 IBM LTO6 8 Gb FC with Oracle Key Manager compatibility for StorageTek SL3000 and StorageTek SL4000 0464970+1332D70 021 19243780 2 1 B58179- (PREM-SPRT-SYS) LTO6, IBM, FC, SL3000 0464970+1332D70 021 19243780 3 1 B58179- (PREM-SPRT-SYS) StorageTek LTO tape drive: 1 IBM LTO6 8 Gb FC with Oracle Key Manager compatibility for StorageTek SL3000 and StorageTek SL4000 0464970+1332D70 050 19243780 4 1 B58179- (PREM-SPRT-SYS) LTO6, IBM, FC, SL3000 0464970+1332D70 050 19243780 5 1 B58179- (PREM-SPRT-SYS) StorageTek LTO tape drive: 1 IBM LTO6 8 Gb FC with Oracle Key Manager compatibility for StorageTek SL3000 and StorageTek SL4000 0464970+1332D70 053 19243780 6 1 B58179- (PREM-SPRT-SYS) LTO6, IBM, FC, SL3000 0464970+1332D70 053 19243780 7 1 B58179- (PREM-SPRT-SYS) StorageTek LTO tape drive: 1 IBM LTO6 8 Gb FC with Oracle Key Manager compatibility for StorageTek SL3000 and StorageTek SL4000 0464970+1333D70 019 19243780 8 1 B58179- (PREM-SPRT-SYS) LTO6, IBM, FC, SL3000 0464970+1333D70 019 19243780 9 1 B58179- (PREM-SPRT-SYS) Brocade 300 Switch with eight 8 Gb activated ports and E_port license 0742025- 1205ALJ013 18394798 10 1 B58179- (PREM-SPRT-SYS) BROCADE 300 24-PORT FC 8G SFP 0742025- 1205ALJ013 18394798 11 1 B58179- (PREM-SPRT-SYS) Brocade 300 Switch with eight 8 Gb activated ports and E_port license 0742025- 1207ALJ005 18394798 12 1 B58179- (PREM-SPRT-SYS) BROCADE 300 24-PORT FC 8G SFP 0742025- 1207ALJ005 18394798 13 1 B58179- (PREM-SPRT-SYS) Brocade 300 Switch with eight 8 Gb activated ports and E_port license 0742025- 1207ALJ006 18394798 14 1 B58179- (PREM-SPRT-SYS) BROCADE 300 24-PORT FC 8G SFP 0742025- 1207ALJ006 18394798 15 1 B58179- (PREM-SPRT-SYS) Brocade 300 Switch with eight 8 Gb activated ports and E_port license 0742025- 1207ALJ00A 18394798 16 1 B58179- (PREM-SPRT-SYS) BROCADE 300 24-PORT FC 8G SFP 0742025- 1207ALJ00A 18394798 17 1 B58179- (PREM-SPRT-SYS) Brocade 300 Switch with eight 8 Gb activated ports and E_port license 0742025- 1207ALJ00G 18394798 18 1 B58179- (PREM-SPRT-SYS) BROCADE 300 24-PORT FC 8G SFP 0742025- 1207ALJ00G 18394798 19 1 B58179- (PREM-SPRT-SYS) StorageTek SL3000 modular library system: base module with 4 cartridge expansion modules, 1 drive array with 8-drive slots, 700 activated cartridge slots, 2269-2869 physical slots. HW activation permit required 1006SG0801 17036143 20 1 B58179- (PREM-SPRT-SYS) SL3000,BASE W/FOUR CEMS, 700 SLOT 1006SG0801 17036143 21 2 B58179- (PREM-SPRT-SYS) Sun ZFS Storage 7420 ATO BOM product family top level part number 1207FMJ05A 18394798 22 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1207FMJ05A 18394798 23 1 B58179- (PREM-SPRT-SYS) StorageTek 8 Gb Fibre Channel PCIe HBA dual port QLogic (for factory Installation) 1207FMJ05A 18394798 24 2 B58179- (PREM-SPRT-SYS) Sun 10Gbps Dual Rate SFP+ SR 1207FMJ05A 18394798 25 1 B58179- (PREM-SPRT-SYS) Sun Dual 10GbE SFP+ PCIe Low Profile Adapter 1207FMJ05A 18394798 26 16 B58179- (PREM-SPRT-SYS) Sun Fire X4470 server: 8 GB memory 1207FMJ05A 18394798 27 1 B58179- (PREM-SPRT-SYS) Sun ZFS Storage 7420: controller for cluster configuration with 2 Intel(R) Xeon(R) E7530 6-core 1.86 GHz processors and 2 SAS-2 HBAs (for factory installation) 1207FMJ05A 18394798 28 2 B58180- (DATA-RETENTION) Sun ZFS Storage 7420 ATO BOM product family top level part number 1207FMJ05A 18394798 29 1 B58180- (DATA-RETENTION) StorageTek 8 Gb Fibre Channel PCIe HBA dual port QLogic (for factory Installation) 1207FMJ05A 18394798 30 2 B58180- (DATA-RETENTION) Sun 10Gbps Dual Rate SFP+ SR 1207FMJ05A 18394798 31 1 B58180- (DATA-RETENTION) Sun Dual 10GbE SFP+ PCIe Low Profile Adapter 1207FMJ05A 18394798 32 16 B58180- (DATA-RETENTION) Sun Fire X4470 server: 8 GB memory 1207FMJ05A 18394798 33 1 B58180- (DATA-RETENTION) Sun ZFS Storage 7420: controller for cluster configuration with 2 Intel(R) Xeon(R) E7530 6-core 1.86 GHz processors and 2 SAS-2 HBAs (for factory installation) 1207FMJ05A 18394798 34 2 B58179- (PREM-SPRT-SYS) Sun ZFS Storage 7420 ATO BOM product family top level part number 1207FMJ05C 18394798 35 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1207FMJ05C 18394798 36 1 B58179- (PREM-SPRT-SYS) StorageTek 8 Gb Fibre Channel PCIe HBA dual port QLogic (for factory Installation) 1207FMJ05C 18394798 37 2 B58179- (PREM-SPRT-SYS) Sun 10Gbps Dual Rate SFP+ SR 1207FMJ05C 18394798 38 1 B58179- (PREM-SPRT-SYS) Sun Dual 10GbE SFP+ PCIe Low Profile Adapter 1207FMJ05C 18394798 39 16 B58179- (PREM-SPRT-SYS) Sun Fire X4470 server: 8 GB memory 1207FMJ05C 18394798 40 1 B58179- (PREM-SPRT-SYS) Sun ZFS Storage 7420: controller for cluster configuration with 2 Intel(R) Xeon(R) E7530 6-core 1.86 GHz processors and 2 SAS-2 HBAs (for factory installation) 1207FMJ05C 18394798 41 2 B58180- (DATA-RETENTION) Sun ZFS Storage 7420 ATO BOM product family top level part number 1207FMJ05C 18394798 42 1 B58180- (DATA-RETENTION) StorageTek 8 Gb Fibre Channel PCIe HBA dual port QLogic (for factory Installation) 1207FMJ05C 18394798 43 2 B58180- (DATA-RETENTION) Sun 10Gbps Dual Rate SFP+ SR 1207FMJ05C 18394798 44 1 B58180- (DATA-RETENTION) Sun Dual 10GbE SFP+ PCIe Low Profile Adapter 1207FMJ05C 18394798 45 16 B58180- (DATA-RETENTION) Sun Fire X4470 server: 8 GB memory 1207FMJ05C 18394798 46 1 B58180- (DATA-RETENTION) Sun ZFS Storage 7420: controller for cluster configuration with 2 Intel(R) Xeon(R) E7530 6-core 1.86 GHz processors and 2 SAS-2 HBAs (for factory installation) 1207FMJ05C 18394798 47 2 B58179- (PREM-SPRT-SYS) Sun Disk Shelf 1208FMD043 18394798 48 2 B58179- (PREM-SPRT-SYS) 1 SLC SAS-2 SSD 3.5-inch write flash accelerator with stingray bracket (for factory installation) 1208FMD043 18394798 49 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD043 18394798 50 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD043 18394798 51 20 B58179- (PREM-SPRT-SYS) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD043 18394798 52 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD043 18394798 53 2 B58180- (DATA-RETENTION) Sun Disk Shelf 1208FMD043 18394798 54 2 B58180- (DATA-RETENTION) 1 SLC SAS-2 SSD 3.5-inch write flash accelerator with stingray bracket (for factory installation) 1208FMD043 18394798 55 2 B58180- (DATA-RETENTION) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD043 18394798 56 1 B58180- (DATA-RETENTION) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD043 18394798 57 20 B58180- (DATA-RETENTION) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD043 18394798 58 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD043 18394798 59 2 B58179- (PREM-SPRT-SYS) Sun Disk Shelf 1208FMD044 18394798 60 2 B58179- (PREM-SPRT-SYS) 1 SLC SAS-2 SSD 3.5-inch write flash accelerator with stingray bracket (for factory installation) 1208FMD044 18394798 61 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD044 18394798 62 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD044 18394798 63 20 B58179- (PREM-SPRT-SYS) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD044 18394798 64 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD044 18394798 65 2 B58180- (DATA-RETENTION) Sun Disk Shelf 1208FMD044 18394798 66 2 B58180- (DATA-RETENTION) 1 SLC SAS-2 SSD 3.5-inch write flash accelerator with stingray bracket (for factory installation) 1208FMD044 18394798 67 2 B58180- (DATA-RETENTION) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD044 18394798 68 1 B58180- (DATA-RETENTION) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD044 18394798 69 20 B58180- (DATA-RETENTION) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD044 18394798 70 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD044 18394798 71 2 B58179- (PREM-SPRT-SYS) Sun Disk Shelf 1208FMD045 18394798 72 2 B58179- (PREM-SPRT-SYS) 1 SLC SAS-2 SSD 3.5-inch write flash accelerator with stingray bracket (for factory installation) 1208FMD045 18394798 73 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD045 18394798 74 20 B58179- (PREM-SPRT-SYS) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD045 18394798 75 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD045 18394798 76 2 B58180- (DATA-RETENTION) Sun Disk Shelf 1208FMD045 18394798 77 2 B58180- (DATA-RETENTION) 1 SLC SAS-2 SSD 3.5-inch write flash accelerator with stingray bracket (for factory installation) 1208FMD045 18394798 78 1 B58180- (DATA-RETENTION) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD045 18394798 79 20 B58180- (DATA-RETENTION) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD045 18394798 80 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD045 18394798 81 2 B58179- (PREM-SPRT-SYS) Sun Disk Shelf 1208FMD04D 18394798 82 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD04D 18394798 83 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD04D 18394798 84 20 B58179- (PREM-SPRT-SYS) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD04D 18394798 85 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD04D 18394798 86 2 B58180- (DATA-RETENTION) Sun Disk Shelf 1208FMD04D 18394798 87 2 B58180- (DATA-RETENTION) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD04D 18394798 88 1 B58180- (DATA-RETENTION) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD04D 18394798 89 20 B58180- (DATA-RETENTION) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD04D 18394798 90 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD04D 18394798 91 2 B58179- (PREM-SPRT-SYS) Sun Disk Shelf 1208FMD04E 18394798 92 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD04E 18394798 93 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD04E 18394798 94 20 B58179- (PREM-SPRT-SYS) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD04E 18394798 95 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD04E 18394798 96 2 B58180- (DATA-RETENTION) Sun Disk Shelf 1208FMD04E 18394798 97 2 B58180- (DATA-RETENTION) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD04E 18394798 98 1 B58180- (DATA-RETENTION) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD04E 18394798 99 20 B58180- (DATA-RETENTION) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD04E 18394798 100 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD04E 18394798 101 2 B58179- (PREM-SPRT-SYS) Sun Disk Shelf 1208FMD04F 18394798 102 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD04F 18394798 103 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD04F 18394798 104 20 B58179- (PREM-SPRT-SYS) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD04F 18394798 105 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD04F 18394798 106 2 B58180- (DATA-RETENTION) Sun Disk Shelf 1208FMD04F 18394798 107 2 B58180- (DATA-RETENTION) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 1208FMD04F 18394798 108 1 B58180- (DATA-RETENTION) Sun disk shelf: base chassis with 2 SAS-2 I/O modules, 2 AC PSUs and 2 cooling fans (for factory installation) 1208FMD04F 18394798 109 20 B58180- (DATA-RETENTION) Sun disk shelf: one 3 TB 7200 rpm 3.5-inch SAS-2 HDD with stingray bracket (for factory installation) 1208FMD04F 18394798 110 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit for 19-inch depth racks (for factory installation) 1208FMD04F 18394798 111 1 B58179- (PREM-SPRT-SYS) SL500 30slotw/2IBMLTO4FC4G KEY 559000203261 17036143 112 1 B58179- (PREM-SPRT-SYS) STK,, ,3127908950,N SL500,30 S 559000203261 17036143 113 1 B58179- (PREM-SPRT-SYS) LTO4 HP FC 4Gb SL3000 Dr 574000216033 19135278 114 1 B58179- (PREM-SPRT-SYS) 3127905403, LTO4, FC, HP, SL3000 574000216033 19135278 115 1 B58179- (PREM-SPRT-SYS) LTO4 HP FC 4Gb SL3000 Dr 574000222570 17036143 116 1 B58179- (PREM-SPRT-SYS) 3127905403, LTO4, FC, HP, SL3000 574000222570 17036143 117 1 B58179- (PREM-SPRT-SYS) LTO4 HP FC 4Gb SL3000 Dr 574000224059 17036143 118 1 B58179- (PREM-SPRT-SYS) 3127905403, LTO4, FC, HP, SL3000 574000224059 17036143 119 1 B58179- (PREM-SPRT-SYS) LTO4 HP FC 4Gb SL3000 Dr 574000224060 17036143 120 1 B58179- (PREM-SPRT-SYS) 3127905403, LTO4, FC, HP, SL3000 574000224060 17036143 121 4 B58179- (PREM-SPRT-SYS) FC cable: riser, 50 meters, duplex, LC-LC, 50/125 19243780 122 1 B58179- (PREM-SPRT-SYS) StorageTek SL3000 modular library system: activation permit for dual FC port, for after original system installation 19243780 123 1 B58179- (PREM-SPRT-SYS) StorageTek SL3000 modular library system: dual FC control card 19243780 124 1 B58179- (PREM-SPRT-SYS) StorageTek SL3000 Partitioning - Integrated Software Option - per Tape Library Metric, for after original system installation 19243780 125 10 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit 17675046 126 1 B58179- (PREM-SPRT-SYS) Sun disk shelf: universal rail kit 17675046 127 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 18394798 128 8 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit 17675046 129 2 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit 17675046 130 1 B58180- (DATA-RETENTION) Sun disk shelf: universal rail kit 17675046 131 18 B58179- (PREM-SPRT-SYS) 2M LC to LC FC Optical Cable 18394798 132 1 B58179- (PREM-SPRT-SYS) Brocade 300 Switch with eight 8 Gb activated ports and E_port license 18394798 133 1 B58179- (PREM-SPRT-SYS) Brocade rack rail kit, supports 16.90 inches switches 18394798 134 5 B58179- (PREM-SPRT-SYS) Brocade rack rail kit, supports 16.90 inches switches 18394798 135 8 B58179- (PREM-SPRT-SYS) Dual rate transceiver: SFP+ SR. Support 1 Gb/sec and 10 Gb/sec dual rate 18394798 136 6 B58179- (PREM-SPRT-SYS) Jumper Cable Kit: 1 x 2m C13 18394798 137 2 B58179- (PREM-SPRT-SYS) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 18394798 138 18 B58180- (DATA-RETENTION) 2M LC to LC FC Optical Cable 18394798 139 8 B58180- (DATA-RETENTION) Dual rate transceiver: SFP+ SR. Support 1 Gb/sec and 10 Gb/sec dual rate 18394798 140 2 B58180- (DATA-RETENTION) Power cord: Sun Rack 2 jumper, 2 meters, C14RA plug, C13 connector, 13 A (for factory installation) 18394798 141 1 B58179- (PREM-SPRT-SYS) DualBot. HW activation key required 17036143 142 1 B58179- (PREM-SPRT-SYS) SL3000 100 Cart Slot Upg KEY 17036143 143 1 B58179- (PREM-SPRT-SYS) SL3000 200 Cart Slot Upg KEY 17036143 144 2 B58179- (PREM-SPRT-SYS) SL3000 200 Watt DC Pwr Supply 17036143 145 2 B58179- (PREM-SPRT-SYS) SL3000 AC PDU 240VAC 30 Amp 17036143 146 3 B58179- (PREM-SPRT-SYS) SL3000 DC Power Supply 17036143 147 1 B58179- (PREM-SPRT-SYS) SL500 LTO CEM KEY 17036143 Required Delivery Date: All items shall be received within twelve (12) Months after contract award. Acceptance and Delivery will be to: Atlantic Test Range Attn: Kevin Write 23013 Cedar Point Road, Building 2118 Patuxent River, MD 20670 Shipping Charges: These items will be delivered F.O.B. Destination, and shipping shall be included in the price. Contracting Office Address: 21983 Bundy Road, Building 441 Patuxent River, MD 20670 Technical acceptability will be determined solely on the content and merit of the information submitted in response to this synopsis/solicitation. Therefore, it is incumbent on the offeror to provide sufficient technical literature, documentation, etc. in order for the Government to make an adequate technical assessment of the proposal. A firm fixed price contract is anticipated. The provision at 52.212-1, Instructions to Offerors-Commercial Items, (DEVIATION 2018-O0018) is incorporated by reference and applies to this acquisition. The provision at 52.212-2 Evaluation - Commercial Items (Oct 2014) applies to this acquisition. The Government will award in accordance with FAR Part 12 on a lowest priced, technically acceptable basis. The offeror shall provide backup information verifying the price offered, e.g., a copy of current catalog, invoices for the same equipment, etc. Each offeror shall include a completed copy of the provision at FAR 52.212-3 Offeror Representations and Certifications - Commercial Items (Mar 2020) with its quote. FAR 52.247-34 F.O.B. Destination (Nov 1991) is incorporated by reference and applies to this acquisition. FAR 52.212-4 Contract Terms and Conditions - Commercial Items (Oct 2018) is incorporated by reference and applies to this acquisition. The clause at 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items (DEVIATION 2018-O0021) is incorporated by reference. Quotes are due to Ashley Kendig Contract Specialist contact@example.gov and Joe Merritt, Contracting Officer at contact@example.gov by 12:00 PM Eastern Local Time, Monday, April 4th, 2022. Please provide the following information with your quote: CAGE Code: DUNS#: Payment Terms of NET 30. Pricing - are these items on a commercial published, on-line, or internal Price list. If available on a price list provide a copy. All price listings will be kept confidential. If not available on a price list please provide information on how pricing is determined (example: item cost+ %, labor rate and materials, etc.) Estimated Delivery Date or Period of Performance: Invoicing and payment will be made thru Wide Area Workflow (WAWF), TERMS: NET 30. As of October 1, 2007, it became mandatory to be registered in order to process any government procurement. If you are not registered, please take a moment to do so at https://wawf.eb.mil/.

More opportunities from Department Of Defense → Naval Air Warfare Center Air Division

Same awarding agency

NAICS: 334220
New
Federal
Next Generation Tactical Radio (NGTR)
Solicitation # N00421-27-RFPREQ-TPM209-0199
The Naval Air Systems Command (NAVAIR) is conducting market research to identify potential sources for the Next Generation Tactical Radio (NGTR), a modular Software Defined Radio (SDR) intended for U.S. Navy and Marine Corps aircraft. The NGTR is designed as a form, fit, and function backwards-compatible replacement for the ARC-210 Generation 5 and 6 radios. Key technical requirements include support for voice and data waveforms in the VHF and UHF bands with operational capabilities up to 6 GHz, including specific support for SINCGARS, MUOS, and SATURN. The system must feature a small form factor weighing less than 12.2 pounds, a conduction-cooled unit, and a modular Open architecture utilizing OpenVPX and VNX+ standards to facilitate rapid upgrades and obsolescence management. Security is a critical component of the NGTR, requiring a modular High Assurance Device (HAD) to meet NSA cryptographic and Security Evaluation Requirements Document (SERD) standards, as well as compliance with Zero Trust architecture and Risk Management Framework (RMF) controls. The system must also adhere to NSTISSAM TEMPEST 1-92 and CNSSAM standards. Prospective contractors must demonstrate expertise in agile development, Model-Based Systems Engineering (MBSE), and the ability to obtain Top Secret security clearances. The anticipated acquisition timeline includes an Industry Day in the first quarter of FY27, a final RFP release in the fourth quarter of FY27, and a contract award in the second quarter of FY28, with target fleet delivery scheduled for mid-2034.
Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing

POSTED

about 20 hours ago

DEADLINE

in 25 days
View Details
NAICS: 541330
New
Federal
Presolicitation Notice – Sole-Source Requirement for SNC Precision Approach Radar (PAR) AN/SPN-35E Landing System Upgrade Program (LSUP) Basic Ordering Agreement (BOA) Task Order (TO).
Solicitation # N00421-26-RFPREQ-TW00000-1864
The Naval Air Warfare Center Aircraft Division Webster Outlying Field Air Traffic Control and Landing Systems Division is seeking a sole-source contractor to execute the Precision Approach Radar PAR AN/SPN-35E Landing System Upgrade Program LSUP. This effort involves comprehensive project management, systems, hardware, and software engineering, as well as integration, testing, and the development of Engineering Development Modules. The scope further includes qualification testing, analysis, and logistics support to facilitate the fabrication, modification, repair, replacement, and upgrade of critical components. The intended source for this requirement is Sierra Nevada Corporation, identified as the Original Equipment Manufacturer with the necessary technical data and expertise to perform the work. The contract is structured as a Cost Plus Fixed Fee arrangement with completion CLINs and is anticipated to run from May 2027 through May 2032. All work is expected to be performed entirely at the contractor site. Under the authority of Title 10 U.S.C. Section 3204 and FAR 6.103-1, the acquisition is designated as other than full and open competition. Interested parties must submit capability statements by November 12, 2026, detailing their technical experience, access to intellectual property, and ability to meet the performance schedule.
Engineering Services

POSTED

2 days ago

DEADLINE

in 14 days
View Details
NAICS: 488190
New
Federal
T-6/T-34 Aircraft Maintenance and Contractor Logistics Support (CLS): Request for Proposal (RFP)
Solicitation # N0042126R1011
Solicitation N0042126R1011 is a Request for Proposal issued by the Naval Air Warfare Center Air Division for T-6 and T-34 aircraft maintenance and contractor logistics support. The scope of work includes organizational, intermediate, and on-site depot-level maintenance for T-6 aircraft at NAS Corpus Christi, NAS Pensacola, and NAS Whiting Field, as well as O, I, and D-level support for T-34 aircraft at MCAS Miramar, NAF El Centro, NAS Lemoore, and NAS Oceana. Key deliverables encompass general aircraft maintenance, preservation and depreservation services, detachment mobilization and demobilization, and the provision of functional check flight and aircraft recovery pilots. The contract utilizes an indefinite quantity structure with a mix of firm fixed price and cost-reimbursable CLINs. The government will select a single awardee based on best value using a tradeoff process, with technical capability as the most important factor, followed by past performance, and then price. Technical evaluations are rated from Blue (Outstanding) to Red (Unacceptable), while small business participation is rated on a pass/fail basis. Proposals must be submitted electronically via the PIEE Solicitation Module and must adhere to strict formatting requirements, including the use of specific templates for manning, pricing, and corporate experience. Performance periods are scheduled across multiple years, beginning September 1, 2027. Compliance with various FAR and DFARS clauses is required, including strict adherence to cybersecurity reporting and military marking standards for shipments.
Other Support Activities for Air Transportation

POSTED

2 days ago

DEADLINE

in 8 days
View Details
NAICS: 333998
New
Federal
Air-Gas Desiccant Driers for AN/SPN-50
Solicitation # N0042127Q1005
Solicitation N0042127Q1005 is a firm fixed-price procurement issued by the Naval Air Warfare Center Air Division for the purchase of Air-Gas Desiccant Driers for the AN/SPN-50, specifically manufacturer part number 0024998501 and national stock number 4440-01-227-2693. This is a brand name procurement for Kijero, LLC, and no substitutions are accepted. The requirement is a total small business set-aside, and the award will be granted to the lowest evaluated price that meets all technical and acceptability standards. All quotes must be submitted via email to Gabrielle King by 4:00 PM Eastern Time on November 2, 2026. To be considered, offerors must be registered in the System for Award Management and provide signed documentation verifying they are an authorized distributor or reseller of the original equipment manufacturer. Submissions must be Trade Agreements Act compliant, include the country of origin, and provide sufficient technical data such as specifications or data sheets. Delivery is required by July 2, 2027, to the facility in Saint Inigoes, Maryland, with the requirement that delivery drivers be U.S. citizens. The contract mandates strict adherence to MIL-STD-130 and MIL-STD-129 for unique item identification and packaging, and invoicing must be processed through Wide Area WorkFlow.
All Other Miscellaneous General Purpose Machinery Manufacturing

POSTED

3 days ago

DEADLINE

in 5 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS