Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 1, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Z2DA--B-1 LC rm SG109A Split Replacements

Closed
36C24126Q0542Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561210
New
Federal
Logistic Support for Daegu, Gwangju, Suwon, Cheongju, and Sacheon
Solicitation # W91QVN27RA991
The United States Air Force is conducting market research via a Sources Sought Notice for logistic support services across multiple air bases in the Republic of Korea, including Osan, Kunsan, Daegu, Gwangju, Suwon, Cheongju, and Sacheon. The scope of work involves the maintenance and preservation of War Reserve Materiel, Peacetime Operating Stock, and Pre-positioned War Reserve Stock. Key functional requirements include Traffic Management Office services for worldwide cargo movement, fuels and POL management, supply operations, vehicle maintenance, and the processing of non-serviceable assets. The anticipated period of performance is five years, comprising a 30-day phase-in period, a one-year base period, and four one-year option periods. Eligible vendors must be legally authorized to conduct business in the Republic of Korea. The prime contractor is required to have at least two years of experience in providing comparable logistics and maintenance support. Key personnel must meet specific English proficiency standards via TOEFL iBT scores and obtain necessary security clearances from the ROK Air Force or the U.S. Government. Award evaluation will be based on the Lowest Price Technically Acceptable basis, considering technical capability, past performance, price, and delivery periods. Contractors must adhere to strict military standards for packaging, marking, and hazardous materials handling, and are responsible for maintaining a Wood Packaging Material program.
0411 Aq Hq Contract Augmented

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 561210
New
Federal
RANGE MAINTENANCE AND REPAIR SUPPORT
Solicitation # N4008527R0004
Solicitation N4008527R0004 is a pre-solicitation for Range Maintenance and Repair Support at Marine Corps Base Camp Lejeune and Marine Corps Air Station-New River, including various training facilities and live fire ranges within a 40-mile radius. The contractor will provide all labor, materials, and equipment for general repairs to maintain 115 live fire ranges and 566 training facilities. Scope of work includes carpentry, welding, masonry, electrical, painting, and heavy equipment operations to repair infrastructure such as metal gates, fencing, ammo breakdown tables, and berms. The contract is a 100 percent Small Business Set-Aside under NAICS 561210 with a size standard of 47 million dollars. Joint ventures and teaming arrangements are strictly prohibited. The anticipated contract is a combination Firm-Fixed Price and Non-recurring type consisting of a one-year base period with four twelve-month option periods, for a total potential term of 60 months, with a possible six-month extension under FAR 52.217-8. The total contract estimate is 958,575.00 dollars. Award will be based on the Lowest Price Technically Acceptable (LPTA) procedure, evaluating corporate experience, technical capability, price, and past performance. The solicitation is expected by November 11, 2026, and requires offerors to be registered in the System for Award Management. Performance must adhere to the most recent Service Contract Act Wage Determination.
Navfacsyscom Mid-Atlantic

POSTED

1 day ago

DEADLINE

in 12 days
NAICS: 561210
New
Federal
Operation and Maintenance of Arkansas Lakes Project
Solicitation # W912EE26RA015
Solicitation W912EE26RA015 is a 100% total small business set-aside procurement issued by the U.S. Army Corps of Engineers, Vicksburg District, under NAICS code 561210. The contract is a Firm Fixed Price Indefinite Delivery Indefinite Quantity (IDIQ) vehicle intended for the operation, maintenance, and repair of government-owned facilities and equipment at Lake Ouachita, Lake Greeson, and DeGray Lake in Southwest Arkansas. The scope of work is comprehensive, covering janitorial and custodial services, mowing and landscaping, dumpster and waste disposal, heavy equipment repair, erosion control, and emergency debris removal following natural disasters. The contract structure consists of a base ordering period, four option years, and a final six-month option, with a minimum guarantee of 1,500 dollars and a task order maximum of 9 million dollars. The government will award the contract based on a best-value tradeoff process, prioritizing technical approach, staffing, and management approach as the most important factor, followed by past performance, with price being the least significant factor. Proposals must be submitted in three separate volumes and adhere to strict formatting and page limits. Key requirements include the designation of a Project Superintendent as key personnel, compliance with the EM 385-1-1 Safety Manual, and adherence to Cybersecurity Maturity Model Certification (CMMC) standards. Following several amendments to refine the scope of work and bid schedules, the final response deadline has been extended to November 2, 2026.
W07V Endist Vicksburg

POSTED

1 day ago

DEADLINE

in 4 days
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
245-NETWORK Contract Office 5 (36C245)

POSTED

1 day ago

DEADLINE

in 12 days
NAICS: 561210
New
Federal
Indefinite Delivery/Indefinite Quantity (IDIQ) Custodial, Pest Control, and Grounds Maintenance Service Contract at U.S. Marine Corps Air Station (MCAS) Iwakuni, Japan
Solicitation # N4008426R1026
This Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity (IDIQ) contract, solicitation N4008426R1026, is for custodial, pest control, and grounds maintenance services at U.S. Marine Corps Air Station (MCAS) Iwakuni, Japan. The scope of work includes cleaning for station-funded and CYP facilities, scheduled and as-needed pest management following the MCAS Iwakuni Integrated Pest Management Plan, and the maintenance of improved and prestige grounds, including post-typhoon debris removal. Performance is governed by MCICOM COLS standards for custodial and grounds services. The tentative period of performance extends from April 22, 2027, to October 21, 2035, structured with a base year and multiple option periods. The government will utilize the Lowest Price Technically Acceptable (LPTA) source selection process, evaluating proposals based on total price and three non-cost factors: safety, experience, and past performance. Offerors must provide a five-year safety record and a detailed Safety Management System narrative. Technical requirements include CMMC Level 1 certification, adherence to strict installation access and photography regulations, and the provision of GHS-compliant labeling and safety data sheets in both English and Japanese. Proposals must be submitted electronically via the PIEE Solicitation Module, with invoicing processed through the Wide Area WorkFlow (WAWF) system.
Navfacsyscom Far East

POSTED

1 day ago

DEADLINE

in 5 days
NAICS: 561210
New
Federal
Vehicle Maintenance for Daegu, Gimhae, Gwangju, Suwon, and Cheongju
Solicitation # W91QVN27RA993
Solicitation W91QVN27RA993 is a sources sought notice from the United States Air Force for vehicle maintenance services across multiple locations in South Korea, including Osan, Gunsan, Gwangju, Suwon, Daegu, Gimhae, Cheongju, and Sacheon Air Bases. The contractor is required to provide all management, labor, tools, and equipment to maintain and preserve War Reserve Materiel, Peacetime Operating Stock, Pre-positioned War Reserve Stock, and in-use assets. Key responsibilities include performing scheduled and unscheduled maintenance, vehicle reconstitution within 30 days of a mission support request, and maintaining an overall mission capable rate of at least 80%. The scope also encompasses fleet management, hazardous waste control, and adherence to T.O. 36-series and T.O. 00-25-234 standards. The anticipated period of performance is five years, consisting of a one-year base period with four one-year option periods, starting with a 30-day phase-in period. Award will be based on the Lowest Price Technically Acceptable (LPTA) method, evaluating technical capability, past performance within the last three years, and a delivery schedule not exceeding 30 days after receipt of the order. The prime contractor must have at least two years of experience in logistics support and maintenance for the specified equipment. Eligible Korean contractors must provide specific legal documentation, such as a Certified Copy of Register and Business Registration Certificate, and propose pricing in Korean Won. Compliance with Republic of Korea environmental laws and the establishment of a comprehensive Quality Control Plan are mandatory.
0411 Aq Hq Contract Augmented

POSTED

1 day ago

DEADLINE

in 13 days

AI Contract Overview

Show more

This Sources Sought notice, issued by the Department of Veterans Affairs Network Contracting Office 1, is a market research initiative aimed at identifying qualified vendors capable of replacing two failed Sanyo split-type air conditioning systems at the West Haven VA Medical Center in Connecticut. The requirement specifically calls for the removal and replacement of indoor and outdoor units associated with RM SG109A within Load Center 7 of Building B-1, with the new units matching the original 31,400 BTU cooling capacity, 230/208V single-phase 60 Hz power, and a minimum 15.9 SEER rating. Vendors must demonstrate the ability to complete the work within 30 calendar days of award, including installing equal or similar-sized replacements, inspecting and reusing existing piping if qualified, modifying roof supports only if certified by a Tremco specialist, and ensuring full system functionality. All responses must be submitted by June 8, 2026, at 10 a.m. EST via email to [email hidden], adhere to an eight-page limit in Word or PDF format, and include a completed Sources Sought Worksheet that captures company details, unique entity identifier, CAGE code, and socio-economic status affirmations including SDVOSB, VOSB, HUBZone, or small business certifications. Participation requires prior registration in the System for Award Management (SAM) and the VA's VISTA system to be eligible for future contract awards. The performance location is strictly limited to the West Haven campus, and vendors must have a field service representative within 100 miles. Eligibility further requires a minimum of three years of direct HVAC installation and repair experience with VA facilities, current OSHA 10 and OSHA 30 certifications, and submission of technical training and certification documentation prior to work commencement. Contractors must coordinate all activities with the VA Contracting Officer Representative, obtain necessary permits for lockout/tagout and hot work, comply with VA security protocols including badge issuance and no-photography rules, and adhere to federal records management standards under FAR, 44 U.S.C., the Privacy Act, and Freedom of Information Act. All deliverables including warranties, installation manuals, testing reports, waste manifests, and photographic documentation will be the exclusive property of the U.S. Government with unlimited rights of use and disclosure. A mandatory pre-bid walkthrough is scheduled for June 5, 2026, and subcontracting requires

General Info

VA seeks qualified vendors for B-1 LC RM SG109A AC replacement at West Haven Medical Center.

NAICS

561210 - Facilities Support Services

Place of Performance

VAMC West Haven, West Haven, ME, 06516

Set-Aside

SDVOSBC

Documents

1

Sources Sought Notice 36C24126Q0542 for B-1 LC rm SG109A Split Replacements

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Sheena CarlyleContract Specialist

Full Description

Show more
This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. The purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 561210, Z2DA) with a size standard $47 Million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing B-1 LC RM SG109A Split Replacements at the West Haven VAMC per the requirements below. Refer to the Performance Work Statement below for the requested requirement description. The standard shall be of quality; meeting or exceeding those outlined in the Performance Work Statement. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. Submission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 10 am EST, June 8, 2026. All responses under this Sources Sought Notice must be emailed to contact@example.gov. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Interested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format. SAM: Interested parties shall be register in the System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling +1 (555) 000-0000. Interested parties not registered in SAM will be ineligible to receive a government contract, should a solicitation be issued resulting from this Sources Sought. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract, should a solicitation be issued resulting from this Sources Sought.
Attachment 1 Sources Sought Worksheet QUALIFICATION INFORMATION: Company / Institute Name: _______________________________________________________ Address: ______________________________________________________________________ Phone Number: ________________________________________________________________ Point of Contact: _______________________________________________________________ E-mail Address: ________________________________________________________________ Unique Entity Identifier (UEI) #: ___________________________________________________ CAGE Code: __________________________________________________________________ Other available contract vehicles (GSA/FSS/NASA SEWP/ETC): ________________________ _____________________________________________________________________________ _____________________________________________________________________________ SOCIO-ECONOMIC STATUS: VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. CAPABILITY STATEMENT: Provide a brief capability and interest in providing the service as listed in Attachment 2 PERFORMANCE WORK STATEMENT with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the PWS. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________



Attachment 2


STATEMENT OF WORK B-1, LC 7 RM SG109A SPLIT SYSTEMS REPLACEMENT
VA CONNECTICUT HEALTHCARE SYSTEM (VACHS) VA MEDICAL CENTER WEST HAVEN 950 CAMPBELL AVENUE WEST HAVEN, CT 06516



BACKGROUND VA Connecticut Healthcare System has experienced failure of the two Sanyo split cooling systems that support rm SG109a.
JUSTIFICATION The failure of the existing cooling system that supports electrical equipment within SG109a, part of B-1 s electrical system, and the facility s Load Center 7, has led to the facility to utilize temporary measures for cooling the specific area that are unsustainable and can be unreliable to reduce the temperature for the room. Due to age of existing units being discontinued by manufacturer, replacement of exterior and interior portions of the split shall take place.
PLACE OF PERFORMANCE The place of performance for this contract is VA Connecticut Healthcare System, West Haven VA Medical Center located at 950 Campbell Avenue, West Haven
PERIOD OF PERFORMANCE The Contract Time Period of Performance will be 30 days upon contract award and Notice to Proceed (NTP).
QUALIFICATIONS To be considered eligible for consideration, potential bidders shall have a field service representative located within 100 miles of the West Haven Campus of the VA Connecticut Healthcare System. Service Provider acting as a Prime with subcontracted labor shall meet this requirement.
Bidders shall provide upon request, documentation of certification/training on the specific equipment under the terms of this contract.
Bidders shall be qualified to perform work on Heating, Ventilation and Air Conditioning systems and have completed prior HVAC work and/or inspection projects for VA Connecticut Healthcare System.
Service Provider shall have a minimum of three (3) years of related scope and work experience with commercial and HVAC component installation and repairs as well as all aspects of inspections, cleaning, calibration, and testing in compliance with and clear understanding of relevant codes and regulations.
Service Provider and/or assigned project staff members shall have industry standard certifications and qualifications to include but not limited to current OSHA 30 and OSHA 10 certification and equivalent qualifications associated with requirements herein.
Service Provider shall submit documentation of technical training and certifications for personnel performing all work under the terms of this contract for review and acceptance prior to the start of work on site.
Bidders shall be evaluated on past performance, technical capability, and financial capability to perform the requirements of this work.
Bidders shall perform a mandatory pre-bid walkthrough at 9:30 a.m. on June 5, 2026, at VA Medical Center West Haven located at 950 Campbell Avenue, West Haven, CT 06516. Meet at Building 15 and obtain a temporary badge and complete a sign-in sheet.
SCOPE OF WORK The Service Provider shall furnish all labor, materials, equipment, tools, supervision, and all incidentals to complete work for the services described in this document.
The Service Provider shall submit a project schedule, work procedures, inspection procedures, testing procedures, all safety documentation, HVAC certifications, etc. for review and approval by VA Contracting Officer Representative and Safety Office before the start of work on site.
The Service Provider shall replace the existing SANYO KHS3672R Split Type Air Conditioner Indoor Unit models located within SG109A on the south wall and east wall. Replace the matching SANYO C3672R Split Type Air Conditioning Outdoor Unit models located on the roof. The interior and exterior units should be paired. The Service Provider shall replace the existing SANYO units, which were rated at 31400 BTU cooling capacity with 230/208V, single phased, 60 Hz and 15.9 SEER with equal or similar sized units, including zone quantity (1). Refer to Photos in Attachment A.
Description of Services: The project will include but not be limited to the following:
Service Provider shall schedule and coordinate all work with VA COR, Utilities Supervisor, Electrical and HVAC Supervisors.
All LOTO request and procedures shall be in compliance with the VA Connecticut Healthcare System Medical Center Policy 138-075, provided upon award.
Coordinate all placement and removal of Lock Out Tag Out devices for any energy sources with the VA COR/Maintenance & Operations.
Coordinate Hot Work permit requests with VA Connecticut Healthcare System Safety Service.
Protect all equipment in place during replacement activities.
It is expected that existing piping (electrical and HVAC unit fluids) to and from existing equipment shall be inspected and determined to be of quality for reuse. If inspection deems piping unfit, the Service Provider shall replace it as needed at no extra cost. Minor modifications to support new equipment are expected.
It is not believed that the units are connected to an existing facility BMS. If the units are found to be connected to an existing BMS system, the Service Provider shall determine the feasibility with the COR/POC and HVAC Shop in connecting control within the existing system. If determined feasible, the Service Provider shall provide no more than 10 hours of service to the cause of connecting, testing, and coordinating functional control with the existing BMS.
Service Provider shall dispose of existing equipment and materials properly as guided by the law.
The Service Provider shall remove and reapply insulation as required. The Service Provider shall inspect the system and provide new insulation at locations identified as lacking or missing.
The Service Provider is expected to utilize existing roof supports. If the existing supports must be modified which affects the support and/or roofing, the Service Provider shall be responsible to provide the supports as necessary and to modify the roof as directed by the VA. Please know that the existing roof structure at the units is a Tremco product and shall only be modified/installed by a Tremco certified roofer.
The Service Provider shall complete fully functioning split type units within 30 calendar days of award or negotiated time based upon availability of resources.
Service Provider shall perform an inspection report of all work, repairs, corrections, and testing with photographs and other documentation necessary to confirm information within the report.
SUBMITTALS/DELIVERABLES Service Provider shall furnish product cut-sheet information to the COR/HVAC shop for approval of use. The Service Provider shall provide installation and maintenance manuals for each installed device.
Service provider shall furnish all submittal item documentations (with final dispositions) and final documentation report with all tests, photos, corrections made within 14 business days after work is completed.
Service provider shall furnish all material certifications for any replacement parts used.
Service provider shall furnish a waste manifest as required.
Minimum warranty of one year on all parts, labor, workmanship, and equipment shall be furnished.
SPECIAL INSTRUCTIONS Service Provider Check-in: All employees of the service provider shall comply with VA Security Management Program and obtain permission of the VA Police and restricted from unauthorized access. Upon arrival, the Service Provider shall sign-in at Building 15 in West Haven and receive a temporary identification badge prior to performing services at VA Connecticut Healthcare System. The Service Provider shall wear visible identification always displaying the name and company ID while on site. All site visits shall be coordinated with the VA COR or assigned POC.
Per Directive 1805, smoking, vaping, and smokeless tobacco are prohibited on the grounds of VA facilities, including in vehicles. This Directive applies to all Service providers and their employees.
No photography of VA premises is allowed without written permission of the contracting officer. Patients and staff are not to be photographed at any time.
Parking for Service provider and employees shall be in designated areas only. Service provider shall coordinate with VA COR.
The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall hold and save the government, its officers, and agents, free and harmless from liability of any nature occasioned by the Service provider s performance. Working space and space available for storing materials shall be as determined by the COR. Workers are subject to the rules of the Medical Center applicable to their conduct. Execute work in such a manner as to reduce impacts with work being done by others.
Billing: Provide COR with a report or statement of work completed and include statements with request for payment. Statement should include service completed and the date each service item was completed. Labor charges shall be billed hurly, and any unused labor totals will be credited back to the VA Medical Center on the next billing cycle, upon receipt of the service report.
Safety Codes / Certification / Licensing: Environmental abatement work, if necessary, is to be performed by Service Provider under supervision and monitoring for the VA by a Certified Industrial Hygienist. If suspected ACM, reach out immediate to the VA Contracting Officer and Contracting Officer Representative.
The Service Provider shall comply with all codes as described above, as well as codes customarily applied in VA construction jobs such as NFPA fire code, OSHA, VA Design Guides, etc. Labs used by the Service Provider shall be licensed as required by any applicable governing agencies, and their certifications and licenses shall be included in the reports.
Travel: Service Provider and/or subcontractors will travel from their place of business to the West Haven Medical Center of the VA Connecticut Healthcare System.
Attachment A
NARA Records Management Requirements
The following standard items relate to records generated in executing this contract:
Citations to pertinent laws, codes and regulations such as 44 U.S.C. Chapter 21, 29, 31, and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228.
Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest.
Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records.
Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act.
The Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract.
The Government Agency owns the rights to all data/records produced as part of this contract.
The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. The Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data.
The Contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.].
No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage, or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules.
The Contractor is required to obtain the Contracting Officer s approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material and/or records generated under or relating to this contract. The Contractor (and any sub-contractor) is required to abide by Government and Agency guidance for protecting sensitive and proprietary information.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 238990
New
Federal
Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting a contract for a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The objective is to return the damaged sections to their original alignment, configuration, appearance, structural stability, and security function. The benchmark product is the Ameristar Impasse Trident system, and while genuine components are preferred, equal alternatives may be proposed if they meet all salient characteristics, including the use of corrosion-resistant tamper-resistant hardware and the maintenance of a continuous security boundary. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238990. The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award decisions will be based on the most advantageous offer, considering price, technical capability, and past performance, with a requirement for three relevant references. Proposals must be submitted in three separate PDF volumes (Technical, Past Performance, and Price) to the contract specialist by November 5, 2026. Final acceptance is contingent upon a satisfactory installation inspection, which may include a review by VA Police to ensure operational security.
All Other Specialty Trade Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS