Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

23533433 - RM23-1252 - SECURITY IMPROVEMENTS FOR ICD-705 COMPLIANCE, PM365

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac SouthwestView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Southwest
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Southwest
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
PW WIB FORM 1. WORK LOCATION BASE: NBVC Point Mugu, CA. BUILDING NO.: Building 365 2. LOCATION POC NAME: 3. PROJECT TITLE: SECURITY IMPROVEMENTS FOR ICD-705 COMPLIANCE, PM365 4. IMPACT: The secure annexes of Building 365 are not ICD-705 compliant to support DSSC-5 fielding. The Intelligence Community (IC) Technical Specifications set forth the physical and technical security specifications and best practices for meeting standards of Intelligence Community Standard (ICS) 705-01 (Physical and Technical Standards for Sensitive Compartmented Information Facilities). Building 365 annexes must be brought up to the technical standards required to comply with the Intelligence Community Directive ICD-705 (Sensitive Compartmented Information Facilities) and IEEE 299 testing. 5. DETAILED DESCRIPTION OF WORK: This work includes but is not limited to having a qualified security specialist conduct a comprehensive inspection of all secure areas within Building 365 and determine exactly what building modifications are necessary in order to bring this facility into full compliance with the Intelligence Community Directive ICD-705 (Sensitive Compartmented Information Facilities) and IEEE 299 (standard method for measuring the effectiveness of electromagnetic shielding enclosures). The facility annexes should meet 80dB of RF attenuation in accordance with IEEE 299 Testing and all ICD 705 Technical Specification requirements for the following building components and any other requirements not listed: (a) Perimeter wall construction. (b) Radio Frequency (RF) protection for perimeter walls. (c) Vault construction. (d) Reinforced concrete construction. (e) ... NOTE: description has been truncated, please see Project Note for full description.

More opportunities from Department Of The Navy → Navfac Southwest

Same awarding agency