Autonomous Ion Mass Spectrometer Sentry (AIMSS)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Autonomous Ion Mass Spectrometer Sentry (AIMSS) is a flight-qualified instrument designed to measure plasma density and temperature to improve the prediction of geomagnetic storms. By utilizing electrostatic energy filters and a magnetic field section, the technology can distinguish between ion species with similar masses, specifically nitrogen and oxygen ions, which is critical for validating space weather models. The system offers high mass resolution, simultaneous measurement of multiple species, and commandable ion throughput to prevent detector saturation. Currently at TRL 6 with a planned demonstration on the International Space Station, this technology is applicable to space domain awareness, space weather forecasting, and spacecraft health monitoring for lunar and Mars missions. The intellectual property is protected by several patents and provisional applications. Managed by the Department of Energy through Triad, the opportunity focuses on licensing agreements for commercial innovation rather than external development services.
General Info
Agency
NAICS
Place of Performance
Los Alamos, NM, 87545, USASet-Aside
Timeline
Response Deadline
Organization & Contact Information
Full Description
Satellite measurements of plasma density and temperature help predict the intensity of geomagnetic storms, which can impact satellites, communications, and power systems. Accurate forecasting requires knowledge of plasma composition. However, typical orbital mass spectrometers have difficulty distinguishing between nitrogen (N+) and oxygen (O+) ions due to their similar masses. This limitation makes it difficult to validate modern space weather models, which depend on accurate knowledge of ion composition in near-Earth space. N+ and O+ ions behave differently in space due to differences in their origin, transport, and loss mechanisms. Improving our ability to distinguish between these ions is critical for understanding and predicting space weather.
Advantages
- High mass resolution enables distinction between ion species that are typically unresolved in space-based measurements (e.g., N+ vs O+)
- Simultaneous measurement of multiple ion species for improved data collection efficiency
- Commandable ion throughput allows for high dynamic range without detector saturation
- Flight-qualified design with near-term on-orbit demonstration on the ISS
Technology Description
The AIMSS instrument uses electric and magnetic fields to sort ions first by energy and then by mass. As ions move through the instrument, different species are separated and spread out across the detector as a spectrum, similar to how a prism separates white light into different colors.
First, incoming ions pass through two electrostatic energy filters (ESAs) located at the front of the sensor. These filters allow only ions within a selected energy range to continue through the instrument. By adjusting the voltage applied to each filter, AIMSS can control how many ions reach the detector and adapt to changing plasma density.
Next, the ions enter a magnetic field section that separates them by mass. Lighter ions are deflected more than heavier ions, causing different ion species to land at different positions on the detector.
The detector records where ions land, allowing the instrument to measure multiple ion species at once and determine their mass and energy.
This design achieves clear separation of closely spaced ion species such as N+ and O+, improving the accuracy of plasma composition measurements.
Market Applications
AIMSS supports both scientific and operational markets:
- Space Domain Awareness: Monitoring plasma density and composition to attribute spacecraft anomalies and charging events.
- Space Weather Monitoring and Forecasting : Ion composition measurements of ionospheric plasma to inform space weather models and improve forecasting.
- Space Station Operations for Lunar and Mars Missions : Monitoring spacecraft health, contamination, and charging during extravehicular activities (EVAs) and docking operations.
- Department of Defense / Space Force : Compliance with requirements for onboard space environment sensors.
IP Information
This technology is protected under the following intellectual property:
- U.S. Patent No. 12,476,101 – Ultra-Compact Ion Mass Spectrometer for Space and Laboratory Plasma Measurements (S167645)
- Patent Pending – Dual Electrostatic Plasma Analyzer for Tunable Energy Resolution and Geometric Factor (S-194425)
- Reconfigurable High Voltage Power Supply – U.S. Provisional Application No. 63/515,283
- Electronics Package for Two-Dimensional Imaging Spectrometry (application/patent status to be confirmed)
TRL 6
LA-UR-26-23247
LANL Tech Partnerships: Unlock the Innovative Potential
Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products.
LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov.
Note: This is not a call for external services for the development of this technology.
https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology
m.lanl.gov/tech-search