Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

DALE-06 - NRW 1015, Replace OS&Y Valve And Descale Boiler #2

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac WashingtonView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Washington
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Washington
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
The Project will provide materials and labor to accomplish the following scope of work: Replace a leaking 6” OS&Y steam gate valve for boiler #2 and descale boiler to obtain a (1) year certification. ♦ Receive and deliver (1) 6” OS&Y steam gate valve, (1) 6” gate valve chain operator, (2) Flexitallic gaskets, and 165 gallons of RydLyme descaling agent. ♦ Mobilize onsite to Dalecarlia ♦ Shut down (LOTO) and drain boiler #2. ♦ Remove existing insulation on failed gate valve and set up rigging to remove failed valve. ♦ Remove and dispose of failed valve. ♦ Clean and prepare flanged surfaces on both the piping, and the new valve and rig into place. ♦ Install (2) Flexitallic gaskets on either side of the new valve and tighten to spec using a “cross tightening” pattern. ♦ Introduce descaling agent to boiler and circulate to remove scale. ♦ Fill and start boiler, ensuring proper operation. ♦ Check new steam valve for leaks. ♦ Insulate new steam valve to match existing insulation. ♦ Clean and remove all debris from work area. ♦ De-mobilize The Project does not include the following, which are specifically excluded: ♦ Boiler Certification ♦ Time lost due to access issues. ♦ Balancing; both water and air.♦ Any items not specifically set out in the above scope of work. ♦ Over time, off hours, weekends or Holiday work.