E-WRNMMC-9,9A,19, Replace Steam Generators
Active
FederalContract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of The Navy → Navfac WashingtonView Agency
NAICS
N/A
Place of Performance
USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Organization & Contact Information
Show more
AgencyDepartment Of The Navy → Navfac Washington
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Full Description
Show more
We have identified the need to replace the steam generators with more efficient and reliable systems. Current systems are in need of critical repairs and beyond their useful life cycle. Steam Generators to be replaced: B9 East Penthouse B9 West Penthouse B9A Rm B100 B19 Rm B335; Status Note (as of 13-SEP-24): Please fill out schedule and notes. PDP due 28-Oct; Status Note (as of 13-SEP-24): Please fill out schedule and notes. PDP due 11-Nov; Status Note (as of 29-OCT-24): 29-OCT-2024 Executability by EOY: Design-AE DBB Contract Design: N/A DASN: N/A Status: contacted client 10/29 (not yet scheduled) for walk through, believe an electric water heater is needed History: N/A NEPA: CE to be obtained before construction OPI: N/A; Status Note (as of 30-OCT-24): 30-OCT-2024 Executability by EOY: Design-AE DBB Contract Design: N/A DASN: N/A Did walk through 29OCT24, client needs especially 1 small steam-driven steam generator (10% capacity) now, small electric boiler/water heater, and two control valves, each with a controller. OR's can continue operations during steam generator replacement. History: N/A NEPA: CE to be obtained before construction OPI: N/A; Status Note (as of 30-OCT-24): 30-OCT-2024 Executability by EOY: Design-AE DBB Contract Design: N/A DASN: N/A Did walk through 29OCT24, client needs especially 1 small steam-driven steam generator (10% capacity) now, small electric boiler/water heater, and two control valves, each with a controllers. OR's can continue operations during steam generator replacement. History: N/A NEPA: CE to be obtained before construction OPI: N/A; Status Note (as of 22-NOV-24): 22-NOV-2024 Executability by EOY: Design-AE DBB Contract Design: N/A DASN: N/A Client needs 3 replacement steam generators: Building 9 East & West Penthouses and Building 9. ... NOTE: description has been truncated, please see Project Note for full description.
More opportunities from Department Of The Navy → Navfac Washington