Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on March 4, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fire Damper Inspection

Closed
50400-26-5218839/ACanada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

Government of Canada → Correctional Service of Canada

NAICS

541350 - Building Inspection ServicesView NAICS

Place of Performance

Saskatoon, CAN

Set-Aside

NONE

Documents

(5)

RFP 50400-26-5218839/A Inspection des registres d'incendie

PDF30 pagesrfp

Fire Damper Inspection Services Solicitation for Regional Psychiatric Centre Saskatoon

PDF2 pagesrfp

RFP 50400-26-5218839/A Fire Damper Inspection

PDF31 pagesrfp

NPP French - Fire Damper Inspection Services at Saskatoon Psychiatric Centre

PDF3 pagesrfp

Solicitation Amendment 001 for Fire Damper Inspection 50400-26-5218839/A

PDFamendment

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Correctional Service of Canada
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Correctional Service of Canada
Office AddressN/A
Contacts
Katherine BoothContracting Authority

Full Description

Show more
The Contractor must provide 4-year inspection services in the month of June each year to test the mechanical operation of the Combination fire/smoke dampers. The Contractor must complete inspection of one quarter of the buildings each year to meet the requirement of the 4-year inspections over a 4-year period. The Regional Psychiatric Centre has approximately 600 fire dampers within the institution. The electrical components of the combination fire/smoke dampers are not part of this SOW as they are tested as part of a separate contract. The Contractor must locate existing fire separations and determine whether the required fire and smoke dampers and combinations systems are in place. CSC will provide list of known existing fire dampers to the Contractor.