Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on June 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

AMENDMENT 1 - Q&A Generator Preventative Maintenance Services for Federal Emergency Management Agency, Naval Weapon Station Earle, 201 Route 34, Building C-54, Colts Neck NJ 07722.

Closed
70FBR226Q00000012Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Federal Emergency Management Agency is seeking qualified small businesses to provide preventative maintenance services for an emergency generator located at Naval Weapons Station Earle in Colts Neck, New Jersey. The base period of performance runs from August 19, 2026, to August 18, 2027, with four sequential one-year option periods extending through August 18, 2031, allowing for a potential total contract duration of five years. This procurement is a total small business set-aside under NAICS code 811310, and all offers must be submitted via email to Kendall Feaster and Gennara Mack no later than June 23, 2026, at 5:00 p.m. EST. The scope of work includes quarterly and annual preventative maintenance, routine and emergency service availability, repairs as needed, and monitoring of the existing GEN TRACKER generator monitoring system, with the contractor required to assess and propose upgrades but not replace the current system. Services must be performed on-site at the military installation, where access is restricted to U.S. citizens who can present two forms of photo identification, and all personnel must comply with strict base security protocols, including potential lockdowns and on-site searches. The contract is a fixed-price purchase order governed by FAR Part 13.5, and award will be made using a best-value approach where non-price factors, including technical approach and past performance, are slightly more important than price. Offerors must demonstrate their ability to meet detailed technical requirements outlined in the Performance Work Statement, which includes comprehensive inspections of control circuits, fuel systems, and hardware; documentation of all work using FEMA’s Generator Maintenance Profile Sheet; and timely submission of invoices within six days of service completion. Invoicing and payment procedures are strictly defined, with payments processed within 30 days of proper submission, and accelerated payment terms apply to small business subcontractors. The contractor is responsible for all personnel, equipment, and materials without government-furnished property, and must propose qualified key personnel including project managers and generator mechanics. Compliance with clauses on combating human trafficking, telecommunication equipment restrictions, and accelerated payments to small business subcontractors is mandatory, and all offers must include two recent and relevant past performance examples and pricing data per FAR 15.408, Table 15-2.

General Info

Generator Preventative Maintenance for FEMA at Naval Weapon Station Earle, NJ; small business set-aside.

Agency

Department Of Homeland Security → Region 2: Emergency Preparedness AnView Agency

Contract Value

$4,757.1

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and MaintenanceView NAICS

Place of Performance

NJ, 07722, USA

Set-Aside

SBA

Awardee

BAMAJACK, LLCView Profile

Award Issued Date

Documents

(7)

FEMA Region II Generator Preventive Maintenance PWS NWSE

PDFpws

GENPIC3.jpg

JPG

GENPIC2.jpg

JPG

Technical Evaluation Factors for Generator Services

DOCXevaluation-factors

Solicitation 70FBR226Q00000012 for Generator Preventative Maintenance Services

PDFrfq

GEN+PIC.jpg

JPG

Wage Determination for New Jersey Monmouth and Ocean Counties

PDFwage-determination

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Region 2: Emergency Preparedness An
Contacts2 people available
OfficeNEW YORK, NY, 10278, USA
Organization / Agency
Department Of Homeland Security → Region 2: Emergency Preparedness An
View Agency Profile
Office AddressNEW YORK, NY, 10278, USA

Full Description

Show more

The Purpose of this Solicitation is to procure Generator Preventative Maintenance Services for Federal Emergency Management Agency, Naval Weapon Station Earle, 201 Route 34, Building C-54, Colts Neck NJ 07722.


Base: 08/19/2026 - 08/18/2027


Option 1: 08/19/2027 - 08/18/2028


Option 2: 08/19/2028 - 08/18/2029


Option 3: 08/19/2029 - 08/18/2030


Option 4: 08/19/2030 - 08/18/2031


Response regarding this RFQ shall be directed via email to kendall.feaster@fema.dhs.gov and a copy to gennara.mack@fema.dhs.gov. All responses must be received no later than Tuesday, June 23, 2026, at 5:00pm EST. 



Q&A:


1. Q: Generator Monitoring System (CLIN 0005): The PWS states the current monitoring system is to be assessed, with a proposal for replacement or upgrade provided as part of the contractor's assessment prior to PM beginning. Can the Government confirm whether it intends for the contractor to furnish and install a new monitoring system, or to maintain/service the existing system? If a system is currently installed, can the Government identify the make/vendor so offerors can scope accurately?


A: Intent is to maintain/service current system and or upgrade current system if upgrades are available or needed, not replace with any new system. Current system is GEN TRACKER generator monitoring system.



2. Q: Monitoring system pricing: Should the cost of any replacement/upgrade monitoring system (including hardware and any multi-year monitoring/communication service) be priced as a separate CLIN/line item, or included within the maintenance CLINs?


A:  CLIN line item CLIN0005 is for generator monitoring system.



3. Q: As an alternative to a site visit, would it be possible to obtain photographs of the unit data plate, engine serial number tag, generator nameplate, and a few exterior photos of the generator package? 


A: Pictures attached


 Model# GS00350N6SRAS0983


S/N 353394-1-1-1112


Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS