Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 30, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H--One-Time 3 Boilers Inspection

Awarded
36C24719Q0527Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541350
New
Federal
H399--36C242-27-AP-0524| 528-27-1-6893-0009 Elevator Inspections, Base (4) Canandaigua VA Medical Center (VAMC) & Bath VA Medical Center (VAMC)
Solicitation # 36C24227Q0041
The Department of Veterans Affairs is soliciting quotes for a Qualification of Elevator Inspectors (QEI)-Certified Inspector to serve as a third-party witness for annual and semi-annual safety inspections and testing at the Canandaigua and Bath VA Medical Centers in New York. This service-disabled veteran-owned small business set-aside under NAICS 541350 consists of a 12-month base period starting November 1, 2026, with four additional 12-month option years. The certified inspector is responsible for independent witnessing and reporting using VA Form 10-6167, while a separate maintenance contractor provides the labor and equipment to perform the physical tests. All work must comply with the most current ASME A17.1 and ANSI/ASME 17.2 codes. The scope of work includes semi-annual inspections, annual hydraulic pressure tests, and annual traction no-load tests during the base and final option years, with five-year traction full-load tests scheduled for Bath VAMC in option year one and Canandaigua VAMC in option year two. Services are typically performed in April and October. Award will be based on an evaluation of technical capability, past performance, and total price. Offerors must submit a technical capability statement of no more than 10 pages and adhere to New York State licensing and Service Contract Act wage determinations.
242-NETWORK Contract Office 02 (36C242)

POSTED

about 18 hours ago

DEADLINE

in about 12 hours
NAICS: 541350
New
Federal
H259-- ELECTRICAL 5-YEAR ARC FLASH STUDY (VA-27-00002938)
Solicitation # 36C25227Q0050
The Department of Veterans Affairs is seeking a firm fixed price contract modification for a comprehensive Arc Flash Hazard Analysis at the Iron Mountain VAMC. The project requires a Registered Professional Electrical Engineer with at least five years of experience to oversee the study, which must comply with NFPA 70E, NFPA 70, and IEEE 1584 standards. The scope encompasses all significant electrical distribution locations from the utility supply down to 208V systems, including switchgear, motor control centers, and panelboards. The contractor will perform data gathering and field verification, a three-phase bolted fault short-circuit study, a protective device coordination study, and the calculation of incident energy and flash protection boundaries. Key deliverables include the installation of machine-printed arc flash warning labels, the adjustment of protective devices, and a final comprehensive report featuring time-current curves, fault current calculations, and updated electrical one-line diagrams in AutoCAD and PDF formats. The contractor must also conduct an exit briefing for facility staff to discuss hazard areas and NEC violations. All work must be completed within 180 days of the notice to proceed, with onsite activities performed during normal business hours. This procurement is intended as a sole source award to SDV Services Inc. under 41 U.S.C. 1901 simplified acquisition procedures to ensure consistency with ongoing electrical testing at the facility.
252-NETWORK Contract Office 12 (36C252)

POSTED

about 18 hours ago

DEADLINE

in 4 days
NAICS: 541350
New
Federal
Aviation Operations Center (AOC)- Building Engineer Report (BER)
Solicitation # 15DDHQ27R00000001
Solicitation 15DDHQ27R00000001 is a request for proposals from the Department of Justice, Drug Enforcement Administration, to obtain a Building Engineer Report (BER) for the Aviation Operations Center (AOC) located at Alliance Airport in Fort Worth, Texas. This is a 100% small business set-aside procurement conducted under FAR Part 12 for commercial services, with the government intending to issue a single firm fixed price purchase order. The scope of work requires a comprehensive inspection of the building's interior, exterior, and grounds, covering structural elements, HVAC, plumbing, electrical, life safety, and force protection. Key deliverables include a summarized BER based on a Building Condition Assessment with cost estimates and photographs, a detailed scheduled operations and maintenance plan, and a list of potential energy conservation improvements. Proposals must be submitted electronically to Jose Marin by November 30, 2026, and must be divided into a technical volume and a business volume. The technical volume is limited to 20 pages and will be evaluated based on technical capability, key personnel qualifications, and past performance. These non-price factors are significantly more important than price, although price will be evaluated for reasonableness. Award will be based on the best value to the government. Contractors must comply with strict security requirements, including the submission of Facility Access Request forms, execution of non-disclosure agreements, and completion of mandatory cybersecurity and privacy training. Performance is structured across several tasks, with the final BER due two weeks after the review meeting.
Office Acquisition Management

POSTED

about 18 hours ago

DEADLINE

in about 1 month
NAICS: 541350
New
SLED
HSR26-26 Re-Bid #2 Fresno Building Inspection
Solicitation # HSR26-26
The California High-Speed Rail Authority is soliciting informal bids under solicitation HSR26-26 Re-Bid #2 for a comprehensive on-site building inspection and repair recommendation project for its Fresno Office located at 11111 H Street, Fresno, CA 93721. The selected contractor will be responsible for evaluating all major building systems, including plumbing, sewer, drainage, electrical, HVAC, roofing, security, the building envelope, and life-safety and structural components. Key deliverables include a comprehensive written inspection report with supporting photographs, an executive summary of critical risks, a prioritized list of corrective actions, and rough order-of-magnitude cost estimates for all recommended repairs. The project requires personnel knowledgeable in federal, state, and local building codes, as well as current safety and accessibility standards. The response deadline is November 6, 2026, and the solicitation is categorized under NAICS code 541350. Bidders must provide a valid Class A or Class B license from the California Contractors State License Board and submit several required documents, including a cost sheet, payee data record, and bidder certifications. Evaluation is based on cost reasonableness and past performance, with a 3% to 5% incentive applied for Disabled Veteran Business Enterprise participation. The contract includes strict compliance requirements regarding the Authority's Conflict of Interest Code, the Americans with Disabilities Act, and a ten-year confidentiality survival period. Invoicing is permitted monthly in arrears, and the final report is due five business days after the Authority provides feedback on the initial draft.
California High-Speed Rail Authority

POSTED

about 18 hours ago

DEADLINE

in 9 days
NAICS: 541350
New
SLED
Operation and Management of the Building Department
Solicitation # AD-26-01
The City of Pembroke Pines is soliciting proposals under RFP AD-26-01 for the operation and management of its Building Department. The project utilizes a City-Provided Leadership Model, where the City retains the Chief Building Official and Building Department Operations Manager, while the contractor provides all other necessary administrative, clerical, and technical staff, including Assistant Building Officials, Trade Chiefs, Plan Reviewers, and Inspectors. The selected firm will be responsible for issuing permits, performing inspections, and executing statutory duties in accordance with the Florida Building Code and Broward County Amendments. The contract is for an initial five-year term with one five-year renewal option. Proposals are due by 2:00 pm on November 10, 2026, and must be submitted electronically via the City's e-Procurement Portal. Pricing is based on a proposed percentage of gross revenue derived from building permit fees, with specific daily rates established for key roles such as Assistant Building Officials at 1,500 dollars and Trade Chiefs at 1,000 dollars. Award decisions will be based on the most responsive and advantageous proposal, with preference points available for local Pembroke Pines vendors, Broward County vendors, and Veteran-Owned Small Businesses. Contractors must ensure all personnel have at least three years of relevant experience and hold required state and county certifications. Strict vehicle marking standards are required, including uniform colors and specific City of Pembroke Pines identification. The contractor must also implement a comprehensive Quality Assurance program to track performance metrics such as turnaround times and error rates. Required submittals include a Letter of Intent and a sworn Affidavit of Accuracy.
City Manager's Office

POSTED

2 days ago

DEADLINE

in 13 days
NAICS: 541350
New
SLED
OER Solar Quality Assurance Study and Report
Solicitation # RFP27007093
The State of Rhode Island Office of Energy Resources is soliciting a consultant under RFP27007093 to conduct a Quality Assurance Study and Report for the Renewable Energy Growth Program installations from the 2026-2028 program years. The selected consultant will perform on-site assessments by licensed electricians to ensure systems are safe, high quality, and compliant with NEC and state specifications. Key deliverables include a sampling memo for OER approval, standardized inspection reports for installers and homeowners, a customer feedback survey, and a final report presented in person to the DG Board. The initial contract term is three years starting approximately January 1, 2027, with the possibility of two additional 12-month renewals. Award decisions are based on a weighted scoring system of 106 points, requiring a minimum technical score of 55 points to proceed to cost evaluation. Bidders must provide a detailed cost proposal broken down by specific tasks, ranging from small-scale PV inspections to larger wind and hydropower projects. Mandatory requirements include a Supplemental Bidder Attestation regarding conflicts of interest, an ISBE participation plan for MBE, WBE, or Disability Business Enterprises, and professional certifications such as NABCEP. The consultant must also maintain significant insurance coverage, including 2 million dollars in professional liability and 1 million dollars in commercial general liability and automobile liability.
State of Rhode Island

POSTED

3 days ago

DEADLINE

in 21 days
NAICS: 541350
New
International
PARK VIEW HEALTH AND WELLBEING CENTRE BUILDING SUPERVISOR SERVICES
Solicitation # CAV-FTS-64586
The Cardiff and Vale University Health Board is seeking a qualified consultant for the provision of Building Supervisor Services for the Park View Health and Wellbeing Centre in Ely, Cardiff. Under solicitation CAV-FTS-64586, the appointed supervisor will act as the Health Board's independent representative on-site, providing quality assurance, compliance monitoring, and reporting throughout the construction, commissioning, and handover phases. Key responsibilities include monitoring workmanship and materials against contract documents, inspecting high-risk and concealed work, and maintaining a detailed quality observation and non-conformance log. The contract is estimated at 140,000 GBP excluding VAT and is scheduled as a 90-week appointment, with an assumed 12-month defects period. The successful tenderer will be appointed under an NEC PSC contract and must adhere to strict reporting timelines, including issuing site visit reports within one working day and escalating urgent safety concerns within two hours. Evaluation for the award is based on a Most Economically Advantageous Tender approach, weighted 60 percent for commercial cost and 40 percent for technical quality. Mandatory insurance requirements include 5 million GBP for Professional Indemnity and Public Liability, and 10 million GBP for Employers Liability. The submission deadline for this open procedure is November 16, 2026, with a particular suitability noted for small and medium-sized enterprises.
Cardiff and Vale University Health Board

POSTED

3 days ago

DEADLINE

in 18 days
NAICS: 541350
New
SLED
Third Party Elevator Inspections
Solicitation # 2026-23
The City of Newark, New Jersey, through the Division of Central Purchasing, is soliciting proposals under solicitation number 2026-23 for a Private On-Site Inspection Agency to provide third-party elevator subcode enforcement services. The selected contractor must be authorized by the New Jersey Department of Community Affairs and operate in accordance with N.J.A.C. 5:23-4.14 and the NJBIC. The scope of work requires the agency to provide on-call inspectors under the guidance of the City Construction Code Official, with a minimum staffing requirement of one Elevator Sub-Code Official and at least two full-time elevator inspectors assigned to Newark. The agency must maintain an office staffed at least 40 hours per week and conduct monthly performance review meetings with City representatives to monitor service quality and workload. The contract is for an initial term of three years, with the possibility of two additional one-year renewal terms, totaling a maximum of five years. Proposals must be submitted electronically via the OpenGov e-Procurement Portal by November 24, 2026, at 2:00 pm. Submissions must be divided into a separate technical proposal and cost proposal, accompanied by various certifications, including W-9, Federal Debarment, and disclosures regarding Iran and Russia-Belarus activities. Award decisions will be based on the most advantageous offering that best meets the City's needs, with a focus on responsiveness and the standards of responsibility. Failure to provide required information or submitting inadequate pricing may result in a proposal being deemed non-responsive.
Division of Central Purchasing

POSTED

3 days ago

DEADLINE

in 27 days
NAICS: 541350
New
International
Depot Fire Break & Void Detection Surveys
Solicitation # ocds-h6vhtk-079033
Thameslink Southern Great Northern Limited (TSGN) is seeking a contractor to address fire safety non-compliances across several depots. The project focuses on reviewing existing fire prevention measures within ceiling voids, including fire stopping and fire breaks. The primary deliverable is a comprehensive scope of works for roof void fire protection, which must include fire breaks, fire stopping for existing walls, and a detailed review of void protection aligned with the current fire alarm system. The contract is divided into three geographical lots: Lot 1 covers Bedford, Peterborough, Letchworth, and Welwyn; Lot 2 covers Selhurst, Battersea, Hornsey, Streatham Hill, and Cricklewood; and Lot 3 covers Brighton, Bognor Regis, Hove, Littlehampton, and Horsham. The total estimated value of the project is 540,000 GBP including VAT, with individual lot estimates ranging from 168,000 GBP to 204,000 GBP. The estimated period of performance is one year, from April 26, 2027, to April 25, 2028. Award decisions will be based on a competitive flexible procedure, with evaluation weighted at 60 percent for technical quality and 40 percent for the commercial pricing proposal across all lots. The opportunity is open to small and medium-sized enterprises (SME), and all submissions must be made in English via the electronic portal.
Thameslink Southern Great Northern Limited (TSGN)

POSTED

3 days ago

DEADLINE

N/A

AI Contract Overview

Show more

This sources sought notice is a market research effort by the Department of Veterans Affairs to identify qualified sources for a firm fixed price contract to perform a one-time inspection, damage assessment, and remaining life assessment of three 600 HP English water tube boilers at the William Jennings Bryan Dorn VA Medical Center in Columbia, South Carolina. The estimated period of performance is thirty days from the date of award. The government is specifically seeking information regarding vendor capabilities and socio-economic size classifications under NAICS 541350, with a preference for Service-Disabled Veteran-Owned Small Businesses. The scope of work requires comprehensive internal and external inspections conducted in accordance with National Board and ASME codes. Qualified contractors must provide technicians certified as Level II in Non-Destructive Testing and a Boiler Inspector commissioned by the National Board of Boiler and Pressure Vessel Inspectors. Deliverables include a detailed written report of findings, metallurgical testing results, and corrective action recommendations submitted within seven calendar days of each inspection. This notice is for planning purposes only and does not constitute a formal solicitation.

General Info

Contract Value

$52,869

NAICS

541350 - Building Inspection Services

Place of Performance

William Jenning Bryan Dorn VA Medical Center;6439 Garners Ferry Road;Columbia, SC 29209 USA, GA

Set-Aside

SDVOSBC

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Sources Sought

Notice updated

Response deadline changed from May 16, 2019 to May 31, 2019. The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)
ContactsNo contacts available
OfficeAUGUSTA, GA, 30904, USA
Office AddressAUGUSTA, GA, 30904, USA
ContactsNo contact information available

Full Description

Show more
SOURCES SOUGHT NOTICE: Firm Fixed Price Contract (FFP) DESCRIPTION: This is a sources sought to determine the availability of potential sources having the skills and capabilities necessary to provide One -time Inspection assessment of (3) three Boilers, located at William Jennings Bryan Dorn VA Medical Center, 6439 Garners Ferry Road, Columbia, SC. The estimated period of performance is thirty (30) days from the date of award. Please be aware all Federal, State and local labor laws will be applicable to this procurement including, federal minimum wage as provided in Section 6(a)(1) of the Fair Labor Standards Act and the McNamara-O Hara Service Contract Act. If you have specific questions regarding labor laws, you should contact your local Federal Department of Labor representative. All interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a sources sought synopsis. Questions should be submitted by email to contact@example.gov Provide only the requested information below. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman-owned small business, FSS/GSA contract schedule holders or large business) relative to NAICS 541350 Building Inspection Services (size standard $7.5 M). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to the sources sought synopsis, a solicitation announcement may be published on the FBO website. Responses to the sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to the sources sought announcement. REQUESTED INFORMATION: (1) STATEMENT OF CABABILITY: Submit a brief description, two (2) pages or less, that demonstrates how your company can provide the requested services at time of award. Include your company s experience in performing these services to the VA, other Government (Federal or State) agency, or for a private facility. (2) BUSINESS SIZE AND SOCIO-ECONOMIC STATUS: (a) Indicate whether your business is large or small as defined by the NAICS (b) If small, indicate if your firm qualifies as a small, emerging business, or small disadvantaged business (c) If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act (d) Indicate if your firm is a certified Hub-zone firm (e) Indicate if your firm is a woman-owned or operated business (f) Indicate if your firm is a certified Service-Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) (g) Include the DUNS number of your firm. (h) State whether your firm is registered with the System for Award Management (SAM) at https://www.sam.gov/portal/public/SAM/ and/or the VetBiz Registry at http://vip.vetbiz.gov/. If not, please (i) NOTE that any future solicitation could only be awarded to a company that is registered in SAM and to receive award based on VOSB or SDVOSB status you must be registered in VetBiz Registry. Responses must be emailed to contact@example.gov no later than 12:00NOON EST, Thursday, May 16, 2019. Your response should include both the STATEMENT OF CABABILITY and BUSINESS SIZE AND SOCIO- ECONOMIC STATUS information as explained above. Please place "Attention: Installation of Pressure monitors in the subject line of your email. This notice is to assist the VA in determining sources only. A SOLICITATION IS NOT CURRENTLY AVAILABLE. If a solicitation is issued it will be announced later, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. DRAFT STATEMENT OF WORK INSPECTION OF BOILERS VISN7 - 544 - Columbia VA Health Care System 1. GENERAL: This requirement is for a firm fixed priced service type contract to provide one-time boiler inspection, damage assessment, and remaining life assessment for three (3) boilers (English 600 HP water tube boilers) located at the Dorn VA Medical Center (VAMC) in Columbia, SC. 2. BACKGROUND: The Dorn VAMC is a 216-bed facility, encompassing acute medical, surgical, psychiatric, and long-term care. The hospital is located in Columbia, South Carolina and provides primary, secondary, and some tertiary care. Annually, the Medical Center serves approximately 56,116 patients. Satellite outpatient clinics are located in Anderson, Greenville, Florence, Orangeburg, Rock Hill, Sumter, and Spartanburg, South Carolina. 3. PERIOD OF PERFORMANCE: This procurement is for a one-time inspection of three English water tube boilers. Services are to be performed during normal business hours; Monday through Friday, 8:00 a.m. 5:00 p.m. Excluding weekends and holidays. No overtime is allowed at this time. 4. PLACE OF PERFORMANCE: WJB Dorn VA Medical Center 6439 Garners Ferry Road Columbia, SC 29209 5. PERFORMANCE REQUIREMENTS: A Contracting Officer Representative (COR) shall be assigned to this procurement and written notification will be provided to the Contractor after award. Scheduling of work performance shall be arranged through the designated COR/ACOR assigned prior to any work performance. At least a three-day notice shall be provided to the COR prior to any inspection. DRAFT Inspections shall be scheduled for periods when the VA Medical Center determines that the Boilers that are to be inspected internally will not be required for steam supply. To maintain steam service only one boiler at a time will be scheduled for internal inspections per inspection visit. The COR shall be available on-site to monitor all inspections. All safety-related deficiencies shall be immediately reported to the COR during the inspection visit. The Contractor shall provide all labor, tools, and equipment necessary to perform the following deliverable requirements: One-Time Boiler Inspection Damage Assessment Remaining Life Assessment (both internal and external) for three (3) English boilers (600 HP water tube). The Contractor shall provide confined space procedures prior to performing or gaining access to the internal boilers for the inspection work. The boilers scheduled for internal inspection shall be prepared for the inspection by the VA Medical Center personnel prior to the scheduled arrival of the inspector. This includes: Cooling the boilers to near ambient temperature. Having all manways, handholes and furnace access doors open. The boilers cleaned of loose materials waterside and fireside. Electrical lock-out, tag-out in place. Connecting piping isolated. Proper illumination provided. Compliance with confined space access requirements including having safety personnel present in the boiler plant. The boiler inspections shall comply with the guidelines in the current issue of the: NATIONAL BOARD INSPECTION CODE, Part RB In-service Inspection of Pressure-Retaining Items ASME Boiler and Pressure Vessel Code, Section VI or VII as applicable. VHA Boiler Plant Safety Device Testing Manual. VA Medical Center requirements as listed in this document. DRAFT The Contractor s inspector must completely enter the internal spaces of the boiler and visually inspect all internal surfaces. The Contractor shall ensure the review the boiler history includes: Operating conditions Date of last inspection Current inspection certificate ASME stamping on boiler National board registration number History of repairs and modifications Review boiler logs Water test reports Reports on rests performed on the burner controls and interlocks The inspector shall obtain the manufactures design specifications for the boiler and factor these into the evaluation. The Contractor shall assess the external parts of the boilers and boiler accessories, the piping and valves for safety, accessibility, proper maintenance and operation, cleanliness, and compliance with codes. The Contractor shall inspect for evidence of leakage of combustion gases or fluids, externally and internally, including all gaskets. The Contractor shall inspect foundations for signs of stress such as cracking or movement and any possible issues that may cause damage to the boilers. The Contractor shall inspect boilers externally and internally for defects to include: Bulges Blisters Cracks Wasted or eroded material Warping General corrosion Grooving and pitting Damaged insulation. DRAFT The Contractor shall inspect all accessible internal surfaces for waterside and fireside deposits, including scaling, sediment, debris, carbon deposits. The Contractor shall complete the following tasks: Examine all stays and stayed plates. Inspect gas side baffles. Inspect internal drum surfaces and steam separating Internals. Inspect soot blowers and verify proper alignment. Inspect tubes, tube ends and tube alignment. Check for sagging tubes. Test a representative sample of tubes for wall thickness for determination of wear. Any tubes believed to have flame impingement will be tested in addition to the representative sample of tubes. Areas exhibiting overheating or visual indication of metal fatigue will be tested for metallurgical impact of these events. A representative sample of welds shall be tested for integrity and cracking. Verify that all nozzles of internal piping such as feedwater admission and bottom blow off collection are clear with no obstructions. Inspect seating surfaces of manways and handholes. Check that boiler structure is plumb and level with no excessive deformations. Check for missing items such as bolts and nuts. Examine all valve and pipe connections to the pressure vessel. Inspect refractory including burner throat, expansion joint, bull ring, furnace seals, furnace walls and floor. Verify proper alignment of burner assembly. Inspect furnace for evidence of flame impingement. Test operation of water level gage glass. Inspect valves on boiler feedwater, blowdown, drain and steam systems. Inspect piping connected to the boilers for evidence of leakage, provision for expansion, provision of adequate support, proper alignment, evidence of detrimental conditions. DRAFT Inspect piping to the water column, low water cutoffs and alarms, gage glass. Verify that interior of piping is clear of obstructions. Qualification Requirements: The Contractor shall provide technicians certified as being qualified Level II in the Non-Destructive Testing (NDT) methods to be utilized. The certification shall be in accordance with the requirements of the American Society for Non-Destructive Testing (ASNT). The Contractor shall provide a Boiler Inspector who has a valid commission from the National Board of Boiler and Pressure Vessel Inspectors (NB). The Contractor shall provide a Boiler Inspector who is qualified under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code as a legal requirement, and has a representative serving as a member of the ASME Conference Committee. The Contractor shall provide a Boiler Inspector who is qualified in engineering evaluation, damage assessment, and specification of boiler repairs. The Contractor shall provide ready access to level II Wet Magnetic Particle Testing (Wet Mag) and/or Ultrasonic Testing (UT). The Contractor shall provide a boiler inspector who is licensed or registered by the appropriate authority of a State of the United States to write Boiler or pressure vessel insurance. Report Requirements: The Contractor shall provide a written report fully describing all inspections and tests performed to include all findings and recommendations. The condition of all items inspected shall be stated whether acceptable or deficient. A report of all metallurgical testing, analysis, and specification of repair or disposition of the boilers. A report of their opinion of root cause and corrective action to be taken. All deficiencies shall be fully described along with recommendations for methods of correction. Utilize National Board Forms NB-6 and NB-7, or other similar forms acceptable to owner. Provide sketches and photographs as necessary and as requested by owner to show areas identified as not acceptable for continued service or requiring repair. Include test data and calculations. Show locations and extent of all non-destructive testing by sketches. DRAFT The Contractor shall furnish the report within one week (7 calendar days) of each facility inspection in Microsoft Word format by email to the COR and to the VA Headquarters Office designated. The Contractor shall provide recommendations on need for re-inspections after correction of deficiencies. A line item shall be included in the initial proposal for re-inspection of all boilers after the completion of recommended repairs. Contractor shall ensure all tools and equipment are always secured. Tools and equipment must be removed from open areas or stored in secured location during breaks, lunch, and/or at the end of each work day. All debris must be removed from the facility upon completion of service each day. Contractor shall ensure proper signage and/or blockage of service area is provided and clearly visible to ensure patient/employee safety is adhered to. Smoking is not permitted within the facilities at any time. All smoking will be conducted in designated smoking areas only. 6. INVOICES: Payment will be made upon receipt of a properly prepared detailed invoice, prepared by the Contractor and submitted through Tungsten Network (formerly known as OB10) http://www.tungsten-network.com/us/en/. A properly prepared invoice shall contain: Invoice Number and Date Contractor s Name and Address Accurate Purchase Order Number Supply or Service provided Period Supply or Service Provided Total Amount Due Please begin submitting your electronic invoices through the Tungsten Network for payment processing, free of charge. If you have questions about the e-invoicing program or Tungsten Network, contact information is as follows: - - - Tungsten e-Invoice Setup Information: +1 (555) 000-0000 Tungsten e-Invoice email: contact@example.gov FSC e-Invoice Contact Information: +1 (555) 000-0000 FSC e-invoice email: contact@example.gov DRAFT 7. TERMINATION FOR CONVENIENCE: In accordance with FAR 52.212-4 (l) The Government reserves the right to terminate this contract, or any part hereof, for its sole convenience. 8. RECORDS MANAGEMENT LANGUAGE FOR CONTRACTS: The following standard items relate to records generated in executing the contract and should be included in a typical Electronic Information Systems (EIS) procurement contract: Citations to pertinent laws, codes and regulations such as 44 U.S.C chapters 21, 29, 31 and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228. Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records. Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act. Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract. The Government Agency owns the rights to all data/records produced as part of this contract. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data. Contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.]. No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules.

More opportunities from Department Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)

Same awarding agency

NAICS: 236220
New
Federal
Y1DA--FY27 NRM | 619-24-103 | Replace Flooring & Repair Walls in Building 1 (VA-27-00012190)
Solicitation # 36C24727R0009
This Firm Fixed Price Construction contract, identified as project 619-24-103, involves the renovation of designated interior areas of Building 1 at the Central Alabama Veterans Health Care System, West Campus in Montgomery, Alabama. The scope of work includes replacing flooring, repairing and painting walls, installing wall-protection systems and handrails, refinishing doors and frames, and replacing water fountains with bottle-filling stations. The project is estimated to have a magnitude between 1,000,000 and 5,000,000 dollars with a target completion period of 365 calendar days from the award or notice to proceed. Because the work occurs in an operational medical facility, the contractor must implement phased execution, infection-control containment, and interim life-safety measures to protect patients and staff. This acquisition is a 100 percent set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) under NAICS code 236220. Eligible firms must be registered in the SAM database and certified in the SBA database. Per VAAR Clause 852.219-75, special trade contractors are limited to paying no more than 75 percent of the government contract amount to firms that are not certified SDVOSBs or VOSBs. The government will utilize a Trade-Off Source Selection process to determine the best value. This notice is a presolicitation; formal proposals should not be submitted until the official RFP is posted, which is expected on or about November 16, 2026.
Commercial and Institutional Building Construction

POSTED

about 18 hours ago

DEADLINE

in 14 days
View Details
NAICS: 524298
New
Federal
Medicaid Application Assistance Services - Charleston SC
Solicitation # 36C24727Q0048
The Department of Veterans Affairs, Ralph H. Johnson VA Medical Center, is soliciting quotes for Medicaid Application Assistance Services to help patients secure Medicaid benefits. This 8(a) Small Business set-aside contract involves providing all necessary personnel, equipment, and supervision to manage eligibility and enrollment services, with an estimated volume of four patients per month. The scope of work includes proactively coordinating with Medicaid offices, medical center staff, and caregivers to ensure timely application processing and discharge planning. Performance will be monitored via a Quality Assurance Surveillance Plan focusing on application turnaround time, patient satisfaction, and invoicing accuracy. The contract structure consists of a base period from November 17, 2026, to November 16, 2027, with the possibility of four one-year option periods. Services will be performed at the primary medical hospital in downtown Charleston, South Carolina, and seven community outpatient clinics across Trident, Goose Creek, Myrtle Beach, Beaufort, Hinesville, Savannah, and Conway. Award will be based on a comparative evaluation of technical capability, past performance, socioeconomic status, and price. Contractors must maintain significant insurance coverage, including 50 million dollars in general liability, and adhere to strict security prohibitions regarding specific foreign telecommunications equipment. Offers are due by November 3, 2026, at 2:00 PM EST.
All Other Insurance Related Activities

POSTED

2 days ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS