J047--FY26 NRM -Medical Gas Deficiency 610A4-26-507 (VA-26-00058207)

Closed
36C25026B0046Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
CBP#9772 HVAC Air Handling Unit (AHU) and Ductwork Cleaning Services
Solicitation # CBP#9772
Management and Training Corporation (MTC) is seeking bids for solicitation CBP#9772 to provide comprehensive HVAC Air Handling Unit (AHU) and ductwork cleaning services at the Edison Job Corps Center in Edison, New Jersey. This fixed-price, single lump sum subcontracting opportunity focuses on restoring airflow and heat-transfer efficiency for the Kilmer and Edison dormitories. The scope of work includes the inspection and cleaning of twelve AHUs and twenty-eight heating and cooling coils, as well as the cleaning of supply, return, and outside-air ductwork and associated air distribution components. The contractor is also responsible for installing permanent access panels, restoring affected building finishes, and providing operation and maintenance manuals and warranties upon completion. The estimated contract value ranges from 100,000 to 250,000 USD, with a performance period of 90 consecutive business days following a written Notice to Proceed. Bids must be submitted via email to Wendy Lawrence by 3:00 PM EST on November 17, 2026. To be considered, bidders must have completed a mandatory physical site visit and must submit their proposal using the MTC Bid for Lump Sum Contract form, accompanied by a detailed cost breakout on company letterhead. For bids equal to or greater than 25,000 USD, a bid bond guarantee of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A- rating. This opportunity is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Award decisions will be based on overall best value, and the contractor must comply with Davis-Bacon prevailing wage determinations for Middlesex County and various FAR clauses regarding security, privacy, and the Buy American Act.
Edison Job Corps

POSTED

about 3 hours ago

DEADLINE

in 5 days
NAICS: 238220
New
CBP7787 ED1 RM 123 HVAC Compressor Replacement
Solicitation # CBP7787 ED1 RM 123
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum subcontract to replace a failed HVAC/refrigeration compressor at the Sierra Nevada Job Corps Center in Reno, Nevada. The project, identified as CBP7787 ED1 RM 123, has an estimated value between 0 and 25,000 dollars. The scope of work is divided into four phases: preparation and environmental safety, demolition and removal, installation of an OEM-specified compressor with new filter-driers and heaters, and system testing and commissioning. Contractors must adhere to EPA Section 608 regulations for refrigerant recovery and ensure the system is pressure tested to at least 150 PSI and evacuated below 500 microns. Bids will be awarded based on overall best value, and a physical site visit is mandatory prior to submission. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent of the base bid is required, along with performance and payment bonds totaling 100 percent of the contract price. Required documentation includes a detailed bid breakout, a UEI number, and an SF1413 Statement and Acknowledgment form. Contractors must maintain general liability insurance of at least 1 million dollars and worker's compensation with employer's liability of 500,000 dollars. Compliance with Washoe County wage determinations and various FAR clauses, including Buy American and Combating Trafficking in Persons, is required. Final payment is subject to a 10 percent retainage until substantial completion, final inspection, and the delivery of all closeout documents and warranties.
Sierra Nevada Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 6 days
NAICS: 238220
New
MJCC Multiple HVAC Replacement System
Solicitation # mjcc-multiple-hvac-replacement-system
Education & Training Resources (ETR) is seeking quotes for a subcontracting opportunity to provide turnkey replacement of multiple HVAC systems at the Montgomery Job Corps Center in Montgomery, Alabama. The scope of work includes the removal of existing equipment and the installation of new systems across several buildings, specifically targeting units in Buildings A, B, E, F, and G, with capacities ranging from 3.5 to 10 tons. Technical requirements specify the use of R-454B refrigerant, Energy Star certification with minimum EER ratings of 16 for certain units, and compliance with the National Electrical Code and NFPA 101 Life Safety Code. Contractors must provide a 5-10 year warranty on parts and a 2 year warranty on workmanship, and they are required to employ a testing and balancing service to verify airflow. Interested bidders must be registered in SAM.gov with a Unique Entity ID and provide Alabama business licenses, certificates of insurance, a W-9, and an FFATA form. Submissions must include a completed bid sheet with a detailed cost breakdown, a proposed performance schedule, and an Anti-Lobbying Certification. The project is subject to the Davis-Bacon Act for prevailing wages and requires bonding based on the total project value, with 100% payment and performance bonds required for projects exceeding 150,000 dollars. Bids are due by November 27, 2026, at 12:00 PM CST. ETR serves as the sole judge for award selection, and the lowest bid does not guarantee selection.
Montgomery Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 15 days
NAICS: 238220
New
Joliet Job Corps-Request for Quote HVAC Replacement Female Dormitory
Solicitation # joliet-job-corps-request-quote-hvac-replacement-female-dormitory
Management and Training Corporation is seeking bids for a fixed-price, single lump sum subcontract to replace the HVAC system at the Joliet Job Corps Center female dormitory in Illinois. The project scope includes the removal and disposal of existing equipment and the installation of ten new Carrier furnace and air conditioning systems. Additionally, the contractor must install and integrate a Pelican Building Automation System across eleven units, including the ten new systems and one existing unit. The estimated value of the contract ranges from $250,000 to $500,000. Bids must be submitted to Frances McGraw by November 23, 2026, and must include a detailed cost breakout, a signed MTC Bid for Lump Sum Contract form, and a completed Supplier Self-Certification packet. A physical site visit and signature on the attendance roster are mandatory prerequisites for bidding. For bids of $25,000 or more, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A- rating. The contract is subject to the Davis-Bacon Act, requiring compliance with specific Illinois prevailing wage rates and the submission of weekly certified payroll reports for payment. Contractors must maintain general liability insurance of at least $1,000,000 per occurrence and worker's compensation with employer's liability limits of $500,000. Award decisions will be based on overall best value. Performance dates will be established during a mandatory pre-construction meeting following the issuance of a Notice to Proceed.
Joliet Job Corps

POSTED

about 3 hours ago

DEADLINE

in 11 days
NAICS: 238220
New
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project focuses on eliminating severe piping leaks and replacing failing infrastructure in Building CM (Men's Dormitory), Building CW (Women's Dormitory), and Building D (Recreation). The scope of work includes the demolition and disposal of existing distribution piping and air compressors, the installation of a new code-approved piping network and properly sized compressor, and rigorous operational and leak testing in accordance with NFPA 25 (2023 Edition) and OEM specifications. The awarded contractor must complete all work within 30 consecutive business days following a written Notice to Proceed. Bids are due by December 1, 2026, and must include a detailed cost breakout and proof of insurance. A physical site visit is mandatory prior to bid submission. For bids totaling $25,000 or more, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety. Evaluation is based on overall best value and bidder responsiveness. This is an SBA set-aside for HUBZone, Woman-owned, and Service-Disabled Veteran-owned small businesses. Compliance requirements include adhering to Davis-Bacon prevailing wage rates, submitting weekly certified payroll reports, and completing SF 1413 and W-9 forms. First-tier subcontractors with awards exceeding $45,000 must also disclose debarment status per FAR 52.209-6.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 20 days
NAICS: 238220
New
Inland Empire Job Corps-Request for Quote HVAC Replacement Cafeteria & OA CTS
Solicitation # inland-empire-job-corps-request-quote-hvac-replacement-cafeteria-oa-cts
Management & Training Corporation (MTC) is seeking bids for a fixed-price, single lump sum subcontract to replace packaged HVAC units with gas heating at the Inland Empire Job Corps Center in San Bernardino, California. The project focuses on the Cafeteria and OA/CTS areas and includes the removal of existing units, refrigerant recovery per EPA regulations, installation of high-efficiency units, and the modification of gas piping, ductwork, and electrical disconnects. The estimated contract value ranges from $25,000 to $100,000, with a performance period of 60 consecutive business days following the Notice to Proceed. Bids are due by November 23, 2026, and will be awarded based on overall best value. Mandatory requirements for consideration include a physical site visit, a bid bond of 20 percent for bids of $25,000 or more, and a detailed cost breakout on company letterhead. Awarded contractors must provide performance and payment bonds from a surety with at least an A- rating. The project is subject to Construction Wage Rate Requirements, necessitating compliance with California prevailing wages and the submission of worker classifications. Compliance requirements include adherence to OSHA safety standards, the provision of personal protective equipment, and the submission of a Certificate of Insurance. Bidders must provide a Unique Entity ID and complete supplier self-certification forms, with specific SBA certification letters required for HUBZone, Woman-owned, and Service-Disabled Veteran-owned small businesses. Payment will be processed via AIA documents G702 and G703, with a 10 percent retainage withheld until substantial completion and acceptance of the work.
Inland Empire Job Corps

POSTED

about 3 hours ago

DEADLINE

in 12 days
NAICS: 238220
New
CBP7792 Cafeteria Hot Water Heater Replacement
Solicitation # CBP7792
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum subcontract to replace a commercial natural gas-fired water heater at the Sierra Nevada Job Corps Center in Reno, Nevada. The project involves the safe isolation, removal, and legal disposal of a failing unit and the installation of a new commercial-grade 125-gallon natural gas-fired water heater. The estimated price range for this effort is between $25,000 and $100,000. Award will be based on overall best value, with evaluation factors including price, quality, delivery schedule, and relevant experience. Bidders must submit a signed bid form and a detailed cost breakout on company letterhead, including itemized labor, materials, and equipment specifications. For bids equal to or exceeding $25,000, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety. Compliance requirements include adhering to federal standards, Buy American regulations, and prevailing wage rates as specified in Wage Determination NV20250040. Additionally, first-tier subcontractors with awards over $45,000 must disclose debarment status per FAR 52.209-6. The contractor is responsible for all testing, commissioning, and obtaining necessary inspections to ensure reliable hot water service. Final acceptance requires a facility walkthrough and the submission of two sets of operation and maintenance manuals and warranty documentation. Payment will be processed via pay applications using AIA G702 and G703 forms, with a payment term of ten days after receipt for operations-supporting contracts. Bids are due by November 25, 2026, and the project is set aside for small businesses.
Sierra Nevada Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 14 days

AI Contract Overview

Show more

The contract requires comprehensive corrections and upgrades to medical gas systems on the third floor of the VA Northern Indiana Health Care System in Fort Wayne, Indiana, to meet full compliance with NFPA 99, 2018 Edition. All oxygen, medical air, medical vacuum, waste anesthetic gas disposal, nitrogen, and nitrous oxide systems, along with associated valves, alarms, and infrastructure, must be brought to full operational and code-compliant status. Work must occur in sequential phasing with each room fully commissioned before the next begins, and shutdowns require a detailed 14-day advance plan. All installation personnel must be credentialed ASSE 6010 medical gas installers, and brazers must meet ASME BPVC Section IX or AWS B2.2 standards. Dedicated WAGD inlets must be installed in any room where nitrous oxide or halogenated anesthetics are administered, including imaging and CT rooms, treating those spaces as anesthetizing locations with compliant zone valve assemblies and alarm coverage as specified. The project mandates a full Infection Control Risk Assessment (ICRA) before work commences, requiring barriers, negative air pressure, HEPA filtration, dust containment, traffic controls, and strict cleaning protocols, with ongoing compliance monitored by Infection Prevention and Control and the Contracting Officer’s Representative. The scope includes installing new area alarm panels and retrofitting existing ones to monitor all medical gas lines across designated rooms, with full integration, supervised loops, EOL termination, and BMS/nurse-call relay capabilities, all to be certified by an ASSE 6030 Medical Gas Verifier. Zone Valve Boxes (ZVBs) must be relocated or newly installed with intervening walls between valves and controlled outlets, restricted to the same story and never located within the rooms they serve. Nitrogen systems require new zone valves, DISS outlets, and verification in operating rooms lacking coverage. WAGD systems must be engineered with non-contact, oil-free pumps, variable-speed modulation, oxygen-compatible materials, and a minimum five-foot separation from medical vacuum lines, including four passive EVAC inlets and full system validation of vacuum levels, inlet flow, and alarm integrity. Hard ceiling work in surgery ward rooms demands selective demolition, temporary fire-rated closures, ICRA-compliant containment, and full restoration matching existing finishes and fire ratings. Commissioning must follow Specification 22 08 00 and 01 91 00, supervised by a Commissioning Agent,

General Info

Correct medical gas systems on 3rd floor to NFPA 99 standards with full testing, alarms, and infection control.

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

VA Northern Indiana Health Care System (VANIHCS) Fort Wayne Campus, Fort Wayne, IN, 46805, USA

Set-Aside

SDVOSBC

Documents

1
DOCX, High priority: read this firstrfp
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA

Full Description

Show more
SCOPE
A recent medical gas evaluation identified deficiencies on the 3rd Floor. The Contractor shall correct all cited items and ensure all O (OXYGEN), MA (COMPRESS MEDICAL AIR), VAC (MEDICAL VACUUM), WAGD (Waste Anesthetic Gas Disposal), N (Nitrogen), N O (Nitrous Oxide), valves, alarms, and infrastructure are fully code compliant and fully operational.
Code Compliance Requirements All work shall be performed in accordance with NFPA 99, 2018 Edition. Any location where N O or halogenated anesthetic agents may be administered - including CT, X-ray, and imaging rooms using roll in anesthesia machines - shall be equipped with dedicated WAGD inlets. Rooms receiving WAGD shall be treated as anesthetizing locations. Contractor shall provide: A dedicated zone valve assembly per NFPA 99 Section 5.1.4.6.2. Area alarm coverage meeting NFPA 99 requirements.
INFECTION CONTROL RISK ASSESSMENT (ICRA) Contractor shall coordinate with Infection Prevention and Control and complete an ICRA before work begins. ICRA measures may include barriers, negative air, HEPA filtration, dust containment, restricted work hours, cleaning protocols, and traffic controls. Contractor must implement and maintain all ICRA requirements for the project duration and promptly correct any deficiencies identified by Infection Control, Safety, or the COR.
Phasing and Shutdown Requirements Submit a phasing and shutdown plan at least 14 working days prior to any interruption. No room may begin until the previous room is fully commissioned. Each Room Must Follow These Phases: Pre Construction Coordination ICRA Containment Setup Selective Ceiling Demolition & Rough In Gas Shutdowns & Tie Ins. Follow NFPA 99 procedures for tie ins, including depressurization, blow down, leak testing, and post connection re verification. Installation personnel must be credentialed: ASSE 6010 medical gas installers. Brazers qualified per ASME BPVC Section IX / AWS B2.2. Device Installation Ceiling Restoration (hard ceiling rooms only, as applicable in others) NFPA 99 Room Level Testing & Commissioning (CxA witnessed). Room level commissioning includes flow, pressure, cross connection testing, ZVB verification, alarm testing, labeling, and source system checks. Room Closeout & Transition to Next Room Maintain continuous facility operations. Comply with infection control, egress, and safety standards in active care areas.
Area Alarm Deficiency: Surgery Ward (Surgery Rooms and Recovery Room) lack any aliquant area alarm. Correction: Provide and install new panels and update existing area alarm to support at the minimum: O , MA, VAC, WAGD, N , and N O. Include all transducers, wiring, labeling, and verification. Provide and install one (1) new Master Area Alarm Panel in Room #3204. New area alarm panel shall support: O , MA, VAC, WAGD, N , and N O. Retrofit the existing hallway area alarm panel and sensors for monitoring rooms #3210 and #3218. Area alarm panel for shall support: O , MA, VAC, and WAGD. Provide one (1) new area alarm panel in the hallway for monitoring rooms #3235 and #3225. New area alarm panel shall support: O , MA, VAC, WAGD, N , and N O. Additional Requirements: All panels shall be fully integrated, tested, and commissioned in accordance with NFPA 99 5.1.11. Dedicated conduit for low-voltage cabling. Supervised loops with proper EOL termination. Panel mounting, programming, and labeling. Relay outputs for BMS / nurse-call integration if required. Sensor commissioning on every monitored line. Full simulated alarm test at each source and each panel. Perform full functional testing, including setpoints, audible/visual alarms, test mode, and signal accuracy checks. Final verification shall be completed by a qualified ASSE 6030 Medical Gas Verifier. Provide a one year warranty on parts, labor, and workmanship.
Zone Valve Box (ZVB) Deficiency: Operation Room (PRE OP) and Endoscope lack required intervening walls between ZVBs and the outlets/inlets they serve. Surgery Ward lacks ZVBs. Correction: Revise architectural layout to include intervening walls. Provide all necessary piping, enclosures, labeling, and materials. Room #3304 (PRE OP) - Relocate existing ZVB (O , MA, VAC) to NFPA compliant hallway locations. Rooms #3315 (Endo) - Relocate existing ZVB (O , MA, VAC) to NFPA compliant hallway locations. Room 3210 Provide one (1) new ZVB (WAGD, O , VAC, MA). Room 3218 Provide one (1) new ZVB (WAGD, O , VAC, MA). Room 3235 Provide one (1) new ZVB (WAGD, N O, N ) and one (1) ZVB (O , MA, VAC). Room 3225 Provide one (1) new ZVB (WAGD, N O, N ) and one (1) ZVB (O , MA, VAC). Requirements per NFPA 99: All installations shall meet NFPA 99 requirements for isolation capability, accessibility, and labeling. Zone valves must be located such that a wall intervenes between valves and outlets they control. Zone valves shall serve only outlets on the same story and not be located inside rooms they control.
Nitrogen (N ) Zone Valves Deficiency: No N zone valves currently serve Operating Rooms #3232 and #3235. Correction: Verify whether any N outlets were previously removed or isolated. Install new N zone valves, DISS standard outlets, and associated labeling/enclosures as required. Perform functional isolation tests, leak checks, and pressure indication verification.
Waste Anesthetic Gas Disposal (WAGD) Systems Deficiency: No WAGD inlets exist in Surgery Ward. Correction: Provide and install WAGD-VAC and WAGD inlet assemblies (headwall or boom). Route piping, label, and test each installation. One WAGD valve per room is required. Provide a complete WAGD system serving rooms #3235, #3225, #3218, and #3210 including: WAGD-VAC: Determine vacuum levels based on anesthetic agents used. Designed for safe operation in environments with elevated oxygen concentrations. Uses a non contact, oil free pumping mechanism that prevents lubrication from entering the airflow stream. All internal components - including those exposed to the airflow path - shall be cleaned and prepared using oxygen compatible processes and materials. Pumps and system modules shall be factory assembled, piped, wired, and tested prior to delivery. Variable speed technology shall modulate pump speed to match real time vacuum demand to improve efficiency, reduce wear, and minimize heat and noise generation. System shall allow single point connection for electrical power, vacuum intake, and exhaust discharge. Exhaust manifold shall include a dedicated drip leg with shutoff valve. Four passive EVAC type WAGD console inlets. Maintain minimum 5 ft separation between medical vacuum and WAGD per NFPA 99 (2005 Edition.) WAGD sensors, service valves, riser valves, and source valves. Size piping, valves, regulators, and branch lines per NFPA 99 pressure loss and performance criteria. Piping, penetrations, supports, and identification Final equipment location shall be coordinated and approved by Owner and Engineer of Record: Validate static and dynamic vacuum levels. Verify WAGD inlet flow capacity. Test alarm conditions and valve isolation. Confirm complete separation between WAGD and medical vacuum systems.
Hard Ceiling The Contractor shall fully account for work above hard lid, non accessible ceilings in the following surgery ward rooms: Hard ceiling work shall be included in the bid and include: Selective demolition only where access is required. Temporary fire rated closures and daily sealing. ICRA compliant barriers, negative air, and HEPA filtration. Full ceiling restoration matching existing finish. Restoration of all fire rated assemblies. Coordination with COR, Infection Control, and Surgery.
Commissioning Requirements Commissioning shall comply with Specification 22 08 00 and 01 91 00. Work includes: Pre functional checklists. Functional performance testing witnessed by the COMMISSIONING AGENT (CXA). Systems manuals, test results, and training deliverables. Refer to Whole Building Commissioning Process Manual (May 1, 2013; minor revisions 11/01/2013).
Post Construction Testing & Verification Contractor shall perform complete NFPA 99 testing including: Alarm system testing audio/visual, setpoints, transducer accuracy. Zone valve testing leak checks, pressure indication, labeling. Outlet/inlet testing static and dynamic pressure, flow drop, cross connection checks. Source system verification dew point, CO monitoring, manifold changeover, relief valve venting, pigtail documentation.
Documentation Deliverables Contractor shall provide: Final test reports and checklists. As built AutoCAD drawings. Updated utility and piping maps. Valve tag lists and labeling photos. Lockout/tagout point identification (Specification 22 05 11).

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 335999
New
Federal
6130--Uninterruptible Power Supply (UPS) for East Indianapolis VA Clinic
Solicitation # 36C25027Q0037
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for four brand-name Medi-Products Silent Sentry Uninterruptible Power Supply (UPS) systems for the new East Indianapolis VA Clinic. The requirement consists of three SSA2080V units and one SSA30180V unit, designed to provide critical electrical backup for one full-size and three half-size pharmaceutical refrigerators. These systems must support a runtime of up to 88 hours to protect temperature-sensitive medical supplies in an unstaffed remote clinic. Technical specifications require a minimum output of 2000 to 3000 Watts with surge capacities of 4,000 to 6,000 Watts, and physical dimensions not exceeding 91 inches in height, 55 inches in width, and 10 inches in depth. This is a firm-fixed-price solicitation set aside for small businesses under NAICS code 335999. Award will be granted to the responsible small business offering the lowest price. Delivery is expected between March 22, 2027, and April 2, 2027, at the East Indianapolis VA Clinic, with shipping terms set as FOB Destination. Offerors must be registered in SAM.gov and comply with the Buy American Act. Special requirements include mandatory VA information security training for employees and strict adherence to data handling and sanitization protocols. Quotes must be submitted by November 23, 2026, and include the offeror's Unique Entity Identifier and a statement of agreement with all solicitation terms.
All Other Miscellaneous Electrical Equipment and Component Manufacturing

POSTED

2 days ago

DEADLINE

in 11 days
View Details
NAICS: 561720
New
Federal
S201--VANIHCS Window Cleaning - Engineering Service Amendment to provide answers to contractor questions
Solicitation # 36C25027Q0016
Solicitation 36C25027Q0016 is a request for quotation issued by the Department of Veterans Affairs for exterior window cleaning engineering services at the Fort Wayne and Marion VA Medical Center campuses in Indiana. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and falls under NAICS code 561720. The scope of work requires the contractor to provide all labor, equipment, and materials to perform exterior washing of windows, frames, sills, sashes, and door glass twice per year. The project includes a detailed inventory of approximately 2,014 windows at the Marion inner buildings, 241 windows at the Marion outer buildings, and 1,277 windows at the Fort Wayne campus. The contract structure consists of a base year starting December 1, 2026, with four subsequent option years, not to exceed a total duration of five years. Award will be granted to the lowest-priced, technically acceptable offeror, with evaluations based on total cost, past performance, and general standards of responsibility. Key requirements include OSHA and Fall Protection certification for all personnel, background investigations per VA security standards, and a mandatory quality control program. Offerors must be registered in the System for Award Management (SAM) and the VA financial system, and must certify compliance with subcontracting limitations, ensuring no more than 50 percent of the service value is paid to non-SDVOSB or non-VOSB firms.
Janitorial Services

POSTED

2 days ago

DEADLINE

in 7 days
View Details
NAICS: 541620
New
Federal
H941--Chemical Hoods & HEPA PM
Solicitation # 36C25027Q0065
The Department of Veterans Affairs Network Contracting Office 10 is soliciting quotes for recurring inspection, testing, certification, environmental monitoring, and preventive maintenance of chemical hoods and HEPA filtration systems at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. This combined requirement covers pharmacy engineering controls, laboratory containment, research equipment, and general engineering HEPA systems. The scope includes semiannual and annual certifications, filter replacements, and specialized services such as BSC decontamination and ASHRAE 110 tracer-gas testing. The contract is a Service-Disabled Veteran-Owned Small Business set-aside, requiring that no more than 50 percent of the contract value be paid to firms not listed as SDVOSBs or VOSBs. The performance period consists of a base year from November 15, 2026, to November 14, 2027, with subsequent option periods extending through May 14, 2032. Work is generally performed Monday through Friday between 0700 and 1800, though after-hours work may be required to avoid disrupting patient care. Award is based on a combination of technical rating and price, and attendance at a mandatory site visit is required for offer eligibility. Successful contractors must adhere to strict quality standards, providing raw measurement data and unambiguous pass/fail certifications via an Acceptance and Reporting Checklist. All offers must be submitted by November 12, 2026, at 8:00 AM EST.
Environmental Consulting Services

POSTED

2 days ago

DEADLINE

in about 3 hours
View Details
NAICS: 484210
New
Federal
V301--539 - Fifth Floor Pharmacy Move Service Contract
Solicitation # 36C25027Q0106
The Cincinnati Veterans Administration Medical Center requires specialized relocation services to move its inpatient pharmacy from the fifth floor to the second floor, with the eighth floor serving as a backup depending on availability. This firm-fixed-price contract, with a projected period of performance from November 2026 to May 2027, involves the disassembly, packing, transport, and reassembly of medical equipment, workstations, and furniture. A critical component of the scope is the provision of controlled environment certification services for non-hazardous pharmacy IV hoods, including laminar flow bench certification, operational particle counts, air sampling, and smoke pattern digital recording. After a temporary period of two to four weeks, the contractor will be required to move all equipment back to its original location on the fifth floor. The contractor must provide all necessary labor, vehicles, and packing materials, including RAM-board for floor protection. Key requirements include the submission of a Certificate of Public Convenience and Necessity from the Ohio PUCO and liability insurance that covers the value of the relocated equipment and facility damages. Performance will be validated through a final walkthrough and functional inspection conducted by the COR and technical personnel within 72 business hours of the move. Security protocols strictly prohibit contractor access to the VA network or any patient and employee PII/PHI. The project requires a dedicated team including a site supervisor, movers, truck drivers, and room certification testers.
Used Household and Office Goods Moving

POSTED

2 days ago

DEADLINE

in 12 days
View Details
NAICS: 811210
New
Federal
Surgical and Instrumentation Maintenance and Repair
Solicitation # 36C25027Q0105
The Department of Veterans Affairs is conducting market research to identify qualified businesses capable of providing surgical and clinical instrumentation maintenance and repair services for the VA Northeast Ohio Healthcare System. The scope of work includes on-site and off-site preventive maintenance, sharpening, repair, renewal, and authorized replacement for surgical instrumentation, case carts, and sterilization containers. These services will support the Louis Stokes Cleveland VA Medical Center and the Outpatient Surgery Center. The contractor is expected to provide weekly on-site services during normal operating hours, performing approximately 80 percent of the workload in a mobile laboratory and 20 percent at an off-site facility. Specialized maintenance is required for ophthalmic, cardiac, vascular, ENT micro-instruments, laparoscopic instruments, scopes, laryngoscopy devices, large retractor systems, and power surgical instruments. The anticipated period of performance is 12 months from the date of award. Key operational requirements include providing a tray maintenance list 48 hours in advance, delivering same-day quality assurance documentation, and using original equipment manufacturer parts for repairs. The contractor must adhere to standards set by the FDA, CMS, CDC, AAMI, AORN, APIC, and HSPA, as well as VA security and infection-control protocols. This effort is categorized under NAICS 811210, and the government is specifically interested in determining if two or more verified Service-Disabled Veteran-Owned Small Business (SDVOSB) or Veteran-Owned Small Business (VOSB) concerns can meet the requirements at fair and reasonable prices.
Electronic and Precision Equipment Repair and Maintenance

POSTED

3 days ago

DEADLINE

in 1 day
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS