Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on April 12, 2010. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Medical Industrial Dishwasher

Closed
10TC0383Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers

Place of Performance

59 MLRS/SGSKM Attn: MEMO 220 Berquist Dr., Suite 1 Lackland AFB, TX 78236, Lackland AFB, TX, 78236, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Deadline changed

Response deadline changed from Feb 12, 2010 to Apr 15, 2010.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts2 people available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
Diana TaylorContract Specialist
Cathy E GarciaContracting Officer

Full Description

Show more
Offer must be "Brand Name or Equal" Miele Professional G7836 Industrial Dishwasher, 62783651 To Include: E 493 Mobile Unit, Product number: 69549301 - Qty. 1 E 494 Insert, Product number: 69549401 - Qty. 8 Neodisher FA, Product number: US489533 - Qty. 1 Neodisher Z, Product number:US483033 - Qty. 1 Reactivation Salt, Product number: B1644 - Qty. 1 Control Unit has: Programmable wash options (12 standard programs with utility programs), RS 232 for connection to printer or PC and 13 languages on LCD screen Temperatures: Wash - adjustable up to 95 degrees Celsius Final rinse - adjustable up to 95 degrees Celsius Cleaning Mechanism: Rotary - dual spray arms on the top and bottom of chamber with a third arm on upper basket Drying: HEPA filtered forced-air drying system with adjustable time and temperature settings with cool-down step. Temp adjustable from 60 - 115 degrees Celsius in 1 degree Celsius increments, time adjustable from 1 - 249 minutes in one-minute increments Water Softener: Built-in softener with easily programmed water hardness control Steam Condenser: Included, no external venting required. Detergent and Neutralizer Dispensing: Detergent - 1 Bellows-type liquid dispenser is standard, detergent is dispensed directly from a 5L container located in the pull-out drawer Neutralizer: 1 Bellow-type liquid dispenser is standard, neutralizer is dispensed directly from a 5L container located in the pull out drawer. Main Circulation Pump: Circulation - 158 gal/min (600 I/min) Cabinet and Chamber Construction: Exterior - Brush finish type 304 stainless steel top, front, sides and bottom Interior - Type 304 stainless steel chamber sides, back and top. Type 316 stainless steel chamber floor and door. Plumbing Connections: Tap (3 Connections): a. Hot water for wash cycles. One 1/2" ID pressure hose, 5'7" long with 3/4" hose thread unions. Input pressures: 21.75 -145 PSI (recommended 25-60 PSI). Minimum flow rate of 2.5 gal.min, max incoming water temperature: 70 degrees Celsius. b., c. Cold water for wash cycles and steam condenser. Two " ID pressure hoses, 5'7" long with " hose thread unions. Input pressures: 21.75 -145 PSI (recommended 25-60 PSI). Minimum flow rate of 2.5 gal.min, max incoming water temperature: 70 degrees Celsius. DI (1 connection): d. DI water for rinse cycles. One " ID pressure hose, 5'7" long with " hose thread unions. Input pressure: 25-145 PSI. If DI system is less than 25 PSI, a pump kit is recommended. Max incoming water temperature: 70 degrees Celsius Drain Connections: Connection - Two 7/8" ID flexible drain hoses, 4'11" long. Max drain height 3'. Max drain length = 13'. Flow Rate - 2.5 gal/min for chamber fill, 1 gal/min for steam condenser fill. Electrical Requirements: Three Phase 208V, 60 Hz, 3 x 20 Amps, 6.6kW total load. Unit to be equipped with a 5'11", 12/4 AWG unterminated power cord Noise level: <70dBa Dimensions: Exterior - 48.26" H x 35.43"W x 27.56D Interior (Chamber) - 19.69" H x 21.1"W Set Aside - 100% Small Business

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS